Violations at 255 Adelphi Street
Brooklyn, NY 11205 · BBL 3-02091-0003 · Back to the property
HPD housing violations
No HPD violations on record
DOB building violations
8 DOB violations, newest first.
- Construction other optional
Hazardous
May 31, 2001
Dob violation - dismissed - Construction other optional
Hazardous
May 31, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed
ECB violations
The newest 50 of 111 ECB violations. The city keeps the complete history.
- Class - 2
Failure to maintain building in code-compliant manner: use of prohibited door and/or hardware per bc 1008.1.8; 27-371(j). at the time of inspection, the following doors had turn knob hardware:-325, 324, 322, 32
Feb 6, 2026 · Penalty $1,250
Active - Class - 2
Failure to maintain building in code-compliant manner. at the time of inspection, the following room doors were not self-closing, 322, 320, 319, 317, 316, 315, 310, 307, 308, 306, 301, 201, 202. 204, 203, 206,
Feb 6, 2026 · Penalty $1,250
Active - Class - 2
Failure to maintain building in code-compliant manner. illumination for exits, exit discharges and public corridors per bc 1006.1; 27-381. at the time of inspection, emergency lights in auditorium were not work
Feb 6, 2026 · Penalty $1,250
Active - Class - 2
Re-issued 35691881m. failure to maintain building in code-compliant manner. at the time of inspection, electrical meter room has water stains and spalling on wall and ceiling. oil tank room had water stain mark
Feb 6, 2026 · Penalty $3,125
Active - Class - 2
28-301.1. re-issued 3569188y. failure to provide ventilation to gas meter room per p115.6(1968 code), fgc appendix e(e4)(2014 code). at the time of inspection, the gas meter in cellar has ne means of ventilatio
Feb 6, 2026 · Penalty $3,125
Active - Class - 2
28-301.1. reissue: 35672435z-cellar level boiler room. the levers for air has been boarded up. air vents for gas meter. remedy: comply with code.
Mar 19, 2025 · Penalty $3,125
Active - Class - 2
Reissue #35672432n-failure to maintain building in code-compliant manner: cellar electrical room has spalling on walls. remedy: comply with code.
Mar 19, 2025 · Penalty $3,125
Active - Class - 2
Reissue: 35671809j-failure to maintain building in code-compliant manner: rm #130 on 1st floor door not closing properly. remedy: comply with code.
Feb 8, 2024 · Penalty $1,562
Resolve - Class - 2
Reissue: 35671810r-exit door not self closing: noted on 3rd floor stairs a, b 2nd fl. #a exit 7,2,3 exit door, not closing properly. remedy:comply with code.
Feb 8, 2024 · Penalty $1,562
Resolve - Class - 1
Reissue: 35671813m-failure to maintain building in code-compliant manner: (cellar level electrical room, ceiling walls have spalling and boiler room ceiling. remedy: comply with code.
Feb 8, 2024 · Penalty $3,125
Active - Class - 2
28-301.1. reissue: 3565093y-cellar level boiler room. the level next to gas meter have been removed and boarded up. remedy: comply with code.
Feb 6, 2024 · Penalty $3,125
Active - Class - 2
Failure to maintain building in code compliant manner.noted at cellar level electrical meter room ceiling and oil boiler room walls both have spalling masonry in various areas throughout.remedy:repair and/or re
Feb 2, 2023 · Penalty $625
Active - Class - 2
Failure to maintain building in code compliant manner.noted at the outside of exit 2,the masonry steps are missing mortar in various areas. also the left side wall has cracks at the top.at the outside of exit 4
Feb 2, 2023 · Penalty $625
Resolve - Class - 2
Failure to maintain building in code compliant manner.illumination forexits,exit discharges and public corridors per bc1006.1;27-381.noted at auditorium and right rear exit sign,cafeteria and by exit#6,gym and
Feb 2, 2023 · Penalty $625
Resolve - Class - 2
Exit door not self-closing.noted on 3rd floor stair a and b,2nd floor stair a,smoke by exit#2,3,7,and 8,exterior doors at exit#2 and 3,auditorium entrance by exit#6 and gym right entrance and rear by exit#4,the
Feb 2, 2023 · Penalty $625
Resolve - Class - 2
Failure to maintain building in code compliant manner.noted the changing room(130)on 1st floor level door is not working properly.remedy:repair and/or replace.
Feb 2, 2023 · Penalty $625
Resolve - Class - 2
Reissue#35650693y.noted at cellar level boiler room,the levers next toi the gas meter have been removed and boarded up with plywood.remedy:comply with notice of violation.28-301.1
Feb 2, 2023 · Penalty $3,125
Active - Class - 2
28-301.1 failure to provide ventilation to gas meter room per p.115.6 (1968 code) fg+c appendix e(e4)(2014 code)noted observed at cellar boiler room/gas meter room louvers from mechanical vents adjacent to gas
Mar 30, 2022 · Penalty $1,250
Active - Class - 2
Failure to maintain building in code compliant manner noted observed at exit #2 exterior stairs right side missing handrail/guardrail creating fall hazard of aprox 4ft onto garden area for faculty,staff,student
Mar 30, 2022 · Penalty $625
Resolve - Class - 2
Failure to maintain building in code compliant manner noted observed exterior stairs at exit #2 missing mortar between joints side stones shifted aprox 1 inch outward at front & sides stone cracked on top.remed
Mar 30, 2022 · Penalty $625
Resolve - Class - 2
Failure to maintain building in code compliant manner noted observed fire proof self closing doors (fpsc) 3rd floor stair "a" & "b" 2nd floor stair "a" 1st floor stair "c" exit 3 aluminum door at exp #10 fpsc d
Mar 30, 2022 · Penalty $625
Resolve - Class - 2
Reissued35557761k failure to maintain bldg in codecompliant manner:noted:observed@stair"a" bulkhead,spalling plaster on walls due to water penetration.repair &or replace.
Mar 30, 2022 · Penalty $1,562
Resolve - Class - 2
Reissued35557763y failure to maintain bldg in codecompliant manner:illumination for exits,exit discharges&public corridors per bc1006.1;27-381.noted:observed existing emergency lights@gym (4lights) by cafeteria
Mar 30, 2022 · Penalty $1,562
Resolve - Class - 2
Reissue35495520z failure to maintain bldg in codecompliant manner.illumination for exits,exit discharges&public corridors per bc1006.1;27-381 noted:some emergency lights in cafeteria&auditorium werent working w
Apr 22, 2021 · Penalty $1,562
Resolve - Class - 2
Reissue35495521k failure to maintain bldg wall(s) or appurtenances.noted:@cellar level on adelphist side,in electricalrm,wall is porous allowing water to go into electricalrm.maintain exterior bldg wall.
Apr 22, 2021 · Penalty $3,125
Resolve - Class - 2
Reissue35495522m failure to maintain bldg in codecompliant manner.noted:@bulkheada theres a leak in the wall.repair &/or replace.
Apr 22, 2021 · Penalty $1,562
Resolve - Class - 2
Reissue35495523y failue to maintain bldg in codecompliant manner.noted:observed 1of the main entrance doors isnt closing properly.repair/replace door.
Apr 22, 2021 · Penalty $1,562
Resolve - Class - 2
Reissue35498540j exit door not selfclosing noted:observed thruout bldgmost doors werent opening&closing properly.repair/replace doors.
Apr 22, 2021 · Penalty $1,562
Resolve - Class - 3
Failure to maintain building in code-compliant. at time of inspection i observed at rear of school yard a temporary wood structure set up asa canopy. due to heavy snowfall,burlap fastened to wood structure has
Feb 6, 2021 · Penalty $500
Resolve - Class - 2
Exit door not self closing note at time of inspection observed trhoughout the entir ebuilding and all floors there are multiple classroom doors that are not self closing which is a hazardous condition if in the
Sep 1, 2020 · Penalty $625
Resolve - Class - 2
Failure to maintain bldg in code compliant manner. noted: at main entrance,one of threee interior door don't close properly due to defective hardware. remed: repair/replace door.
May 15, 2020 · Penalty $625
Resolve - Class - 2
Failure to maintain bldg in code compliant manner. noted: roof leak atbulkhead'a',classroom 317,318,306,304,310,at 3rd fl. remedy: make necessary repairs.
May 15, 2020 · Penalty $625
Resolve - Class - 2
Failure to maintain bldg walls or appurtenances. noted: at cellar,foundation wall at adelphi street side have become porous allowing the water into electrical room,oil tank room & in to the cellar. remedy: main
May 15, 2020 · Penalty $1,250
Resolve - Class - 2
Failure to maintain bldg in code compliant manner illimination. noted:emergency exit lighting observed inoperative when tested at following locations: at auditorium all are inoperative,at cafeteria,1 lighting
May 15, 2020 · Penalty $625
Resolve - Class - 2
Exit door not self closing. note at exit c 1st floor door leading to exits on right hand side missing closure. remedy: repair or replace door
Apr 26, 2019
Resolve - Class - 2
Failure to maintain building in code compliant manner illumination forexits,exit discharges and public corridors per bc 1006.1;27-381. note at gym emergency lights over rear door exit not working. remedy:repair
Apr 26, 2019
Resolve - Class - 2
Failure to maintain building in code compliant manner use of prohibited door and or hardware per bc 1008.8;27-371(j). note the following door have illegal kick stops:main entry door at top of stairs,309,304,214
Apr 26, 2019
Resolve - Class - 2
28-301.1 failure to provide natural or mechanical ventilation to occupied spaces per mc 401.2. note at basement level storage of gas equipment(ie a snowblower) stored inside building. remedy:comply w/ violation
Apr 26, 2019
Resolve - Class - 2
28-301.1 unlawful display of artwork in corridors greater than 20% perfdny 2008 code fc 803.2. note artwork displayed on corridor walls on every floor throughout entire school greater than 20%. remedy:comply w/
Apr 26, 2019
Resolve - Class - 2
Reissued 35330840m failure to provide ventilation to gas meter room per 115.6(1968 code) fgc appendix e(e4)(2014 code). note at basement level boiler room boiler and gas meter have no separation as the gas mete
Apr 26, 2019
Resolve - Class - 2
Failure to maintain building in code compliant manner.noted:at 2nd & 3rd flr public hallways and staircase/exit 7 obstructed by various equipment,bikes,desk chairs,cabinets.rem:remove obstructions.
May 1, 2018
Resolve - Class - 2
Failure to maintain building in code compliant manner.lack of emergency lighting for exits,exit discharges and public corridors per bc100601;27-542 noted:at auditorium,gym and exit 4 emergency lights is disrepa
May 1, 2018
Resolve - Class - 3
Failure to maintain building in code compliant manner.noted:at gym ceiling tiles missing none at various locations.rem:repair and or replace
May 1, 2018
Resolve - Class - 2
Failure to maintain building in code compliant manner.noted:at staircase c roof level water penetration staining walls peeling and in disrepair also waer penetration at basement oil tnk room wate puddling stain
May 1, 2018
Resolve - Class - 2
Failure to maintain building in code compliant manner.noted:at staircases/exits b,3,4,5 and auditorium doors are in disrepair cracked.rem repair and or replace
May 1, 2018
Resolve - Class - 2
Failure to maintain building in code compliant manner.use of prohibited door and or hardware per bc1008.1.8;27-371(j).noted:at staircase b &c installed latch bolt locks on exit/entry doors.rem:provide legal har
May 1, 2018
Resolve - Class - 2
Bc28-301.1/reissue ecb#35267335m issued 05/23/17 failure to provide ventilation to gas meter room per 115.6(1968 code)fgc appendix e(e4)2014code noted:at time of inspection the gas meters have no seperate room
May 1, 2018
Resolve - Class - 2
Exit door(s) not self closing. at time of inspection, in cafeteria on 1st floor exit #5 and #6, auditorium next to stage exit on the right side, stair b 1st floor #2 and #3 doors (stuck due to paints/heat) exte
May 23, 2017
Resolve - Class - 2
28-301.1 unlawful placement of furnishings, decorations or others objects as exits that obstruct access to egress from or visibility thereof per fdny 2008 code; fc 1027.4. at time of inspection, outside
May 23, 2017
Resolve - Class - 2
28-301.1 unalwful display of artwork in corridors greater than 20% per fdny 2008 code; fc 803.3.2 at time of inspection; there are art dis plays beyond 20% outside of room 301, 307,309, 311 papers on tiles
May 23, 2017
Resolve