roofy

340 Myrtle Avenue

Brooklyn, NY 11205BBL 3-02073-0021Map

Owner of record: 340 Myrtle Development LLC

340 Myrtle Avenue is an elevator apartment building built in 2024 in Brooklyn, 11205. It has 63 residential units across 8 floors. The owner of record is 340 Myrtle Development LLC. HPD has recorded 5 housing violations here, most recently on January 9, 2026.

HPD violations
5
DOB violations
5
ECB violations
25
HPD complaints
4

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Jan 9, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 5

  • B

    Repair, replace or provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations defective in the entire apartment located at apt 2h, 2nd story, 4th apartment from west at north

    Jan 9, 2026 · Apt 2H

    Closed — Violation dismissed
  • A

    Properly repair or replace the broken or defective mechanical ventilation system at ceiling in the 1st bathroom from east located at apt 2h, 2nd story, 4th apartment from west at north

    Jul 28, 2025 · Apt 2H

    Closed — Violation dismissed
  • A

    Properly repair or replace the broken or defective mechanical ventilation system at ceiling in the 2nd bathroom from east located at apt 2h, 2nd story, 4th apartment from west at north

    Jul 28, 2025 · Apt 2H

    Closed — Violation dismissed
  • A

    § 329, m/d law and dept. rules and regs. provide a completed certificate of inspection visits in a proper frame at or near mailboxes, bottom edge of frame between 48-62 inches above floor missing at public hall, 1st story

    Jul 28, 2025

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Jun 16, 2025

    Closed — Violation dismissed

DOB building violations · 5

  • Construction other optional

    Partial collapse of approx 1 ft x 10 ft tall section of masonry wall a t structural steel column into public sidealk, remaining brick wall along carlton ave./remdy; owner to hire nyspe to submit report to bk [email protected]

    May 18, 2023

    Dob violation - dismissed
  • Immediate emergency anythingoptional

    Erect 172 linear feet of construction fence on myrtle avenue with 8ft return at exp#1/2 erect 80 linear of construction fence on carlton ave nue with 12ft return at exp#3/4 immediately

    May 16, 2023

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued-failure to file 2022 external low pressure inspection

    Apr 25, 2023

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jun 29, 2016

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2012 inspection report

    May 15, 2014

    Dob violation - dismissed

ECB violations · 25

  • Class - 1

    Gc worked against stop work order under reference complaint# 3978777 issued 10/01/2024. observed 8 story new building completed while under the commissioner order to stop work.

    Jun 2, 2025 · Penalty $12,500

    Resolve
  • Class - 2

    At the time of inspection of a proposed 8-story residential building it was observed inadequate housekeeping on several floors with trash bags filled of materials/ debris blocking the egress path creating a pot

    Jan 9, 2025

    Resolve
  • Class - 1

    At the time of inspection of a proposed 8-story new building at superstructure phase it was observed inadequate guardrails at the roof level missing toe boards. institute and maintain all safety measures requir

    Jan 9, 2025 · Penalty $5,000

    Resolve
  • Class - 2

    At the time of inspection of an active jobsite of an 8-story low rise building at superstructure phase it was observed inadequate storage of material, equipment and debris on the side walk shed platform deck. m

    Jan 9, 2025 · Penalty $2,400

    Resolve
  • Class - 2

    Observed 4-6 workers working on supported scaffold at exposures #1 and #2 above 1st floor while pswo for no work on supported scaffold at exposures #1 and #2 is in effect. no certificate of corrections filed fo

    Dec 26, 2024 · Penalty $625

    Resolve
  • Class - 1

    Observed 4-6 workers working on supported scaffold at exposures #1 and #2 above 1st floor while pswo (issued on 10-30-2024 under complaint #: 3982446) for no work on supported scaffold at exposures #1 and #2 is

    Dec 26, 2024 · Penalty $5,000

    Resolve
  • Class - 1

    Observed supported scaffold at exposures #1 & #2 fully planked, contrary to the approved plans which clearly states "1 level max fully planked" during operations. this conditions presents dislodgement hazards f

    Oct 30, 2024 · Penalty $625

    Resolve
  • Class - 2

    Upon research of the dot, it was observed that the contractor failed to renew dot permits at exposure #1 for storage of equipment & materials in roadway, on carlton ave between myrtle ave & willoughby ave. this

    Oct 30, 2024 · Penalty $625

    Resolve
  • Class - 1

    3308.6.1.4.1 supported scaffold alternative. at time of my inspection observed: proposed 8 stories new building, at 8 fl. decking level 85 feet height approx. missing/inadequate horizontal netting or alternativ

    Oct 1, 2024 · Penalty $2,500

    Resolve
  • Class - 1

    At time of my inspection observed: proposed 8 stories new building, at 8 fl. decking level 85 feet height approx. missing no standpipe in place and state of readiness, creating a potential fire hazardous condit

    Oct 1, 2024

    Resolve
Show 15 more ↓
  • Class - 1

    3303.12: elevators and hoists during construction or demolition. at time of my inspection observed: proposed 8 stories new building, at 8 fl. decking level 85 feet height approx. missing no hoist in place and s

    Oct 1, 2024

    Resolve
  • Class - 2

    Miscellaneous violations.3307.2.1 obstruction of sidewalks.at time of my inspection observed:proposed 8 stories new building,at 8 fl.deckinglevel 85 feet height approx.crane installed at exposure#1 upon request

    Oct 1, 2024 · Penalty $2,500

    Resolve
  • Class - 2

    Observed active site and permit for new 8 story mix use building noted : sws not fully extended @ exposure 1 for roof protection at exposure 4 contrary to bc3307.1stop all work on exposure 1&4 10 feet away fro

    Sep 25, 2024

    Resolve
  • Class - 2

    Active site and permit for 8 story new building. observed: windows on court yard exposure 3 has been not protected contrary to building code stop immediately all work on exposure 3 court yard 10 feet away from

    Sep 25, 2024

    Resolve
  • Class - 1

    Site currently on swo for no use of work zone storage area no street operations#expo1,2. during inspection i observed a delivery taking place at expo#1 forklift moving insulation in storage area. expo#2 has a b

    Sep 12, 2024

    Resolve
  • Class - 1

    Atoi i observed an active construction site with approx. 65 workers on site, a proposed 9-story nb currently at the 2nd floor level. upon review of department records(bis & dob now) observed no permit for nb wa

    Aug 24, 2024 · Penalty $2,500

    Resolve
  • Class - 1

    Work at storage zone-bc 3307.4.7. observed inadequate storage zone, heavy equipment in place at exp. # 1 and exp. # 2. storage zone not enclosed with solid 4 ft plywood and wire mesh on the top as required by c

    Aug 24, 2024 · Penalty $5,000

    Resolve
  • Class - 1

    Failure to provide watchperson-bc-3303.3.atoi at the proposed 9-story nb no construction activities, i observed that there was not a security guard-watchperson as required by code. proposed footprint building i

    Aug 24, 2024 · Penalty $2,500

    Resolve
  • Class - 1

    Atoi i observed an active construction site with approx.65 workers on site, proposed 9-story nb work in progress. upon request for a variance permit for after-hours work none was provided and a review of depart

    Aug 24, 2024 · Penalty $1,250

    Resolve
  • Class - 2

    At the time of inspection active demolition site, i observed demolition in progress with poor housekeeping there are debris blocking egress with 2x4 wood cleats nailed to the ground around the perimeters, creat

    Nov 14, 2023

    Resolve
  • Class - 1

    At the time of inspection active demolition site, i observed demolition in progress with yodocks in place with,no guardrail system around perimeters to protect workers from any fall hazard which can result in

    Nov 14, 2023 · Penalty $5,000

    Resolve
  • Class - 2

    At the time of inspection active demolition site, i observed demolition in progress with no weatherproofing for adjoining property exterior wall at exposure#2 which can create leaks and impair wall during rain

    Nov 14, 2023

    Resolve
  • Class - 2

    Observed job site with active permit # b00923142-i1-fn temp. construction fence 8ft. with all view ports installed on fence at carlton avenue opaque/ block out and not able to see through for its purpose., comp

    Oct 6, 2023 · Penalty $1,000

    Resolve
  • Class - 1

    Failure to maintain building in a code compliant manner. noted at timeof inspection it was observed that several bricks had dislodged from bldg at the corner at exposure 1(myrtle ave) and exposure 4(carlton ave

    May 15, 2023 · Penalty $6,250

    Resolve
  • Non-hazardous

    Work without a permit. work noted: interior renovation commenced throughout. hung ceiling, sheetrock partition on wood studs & raised plywood floor or platform constructed at south section. remedy: stop

    Aug 16, 2000 · Penalty $2,500

    Resolve

Complaints

  • Water leak

    Slow leak

    May 5, 2026 · Apt 2H

    Close
  • Heat/hot water

    Apartment only

    Jan 6, 2026 · Apt 2H

    Close
  • Heat/hot water

    Apartment only

    Dec 19, 2025 · Apt 2H

    Close
  • General

    Ventilation system

    Jun 23, 2025 · Apt 2H

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D7)
Year built
2024
Floors
8
Residential units
63
Building area
61,916 ft²
Lot area
8,828 ft²
Zoning
R7A
Community board
302
Council district
35
Block / lot
2073 / 21
Assessed value
$7,699,050
Landmark / historic district
No

HPD registration #391538, last renewed Jun 2, 2025.

Questions about 340 Myrtle Avenue

Who owns 340 Myrtle Avenue?

The owner of record in NYC Department of City Planning PLUTO data is 340 Myrtle Development LLC.

Does 340 Myrtle Avenue have violations?

Yes. NYC HPD has recorded 5 housing violations at this property.

Is 340 Myrtle Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 340 Myrtle Avenue built?

City records list 2024 as the year it was built.

How many apartments are in 340 Myrtle Avenue?

It has 63 residential units and 64 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.