9 North Elliott Place
Brooklyn, NY 11205BBL 3-02027-0022Map
Owner of record: Nkrt Brooklyn NY LLC
9 North Elliott Place is a walk-up apartment building built in 1899 in Brooklyn, 11205. It has 3 residential units across 2 floors. The owner of record is Nkrt Brooklyn NY LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 14
- ECB violations
- 33
- HPD complaints
- 1
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 14
- Construction other optional
Failure to comply w/commissioner's order contained in dob #061826ce30201pt, issued 6/18/26;comply with all requirements of the aforementioned commissioner's order. immediately retain pe,cs & gc to stablize & protect the site & adj proerties from collapse hazard
Jun 25, 2026
Dob violation - dismissed - Construction other optional
Emerg. wrk: wood joist bldg w/ urm (brick) walls, compromised during a alt. work, danger of collapse.exp 1-4 walls unbraced, joists shifted, exp 2 wall visibly bulged. danger to public & adj props.remedy:retain pe/cs/gc to stabilize. submit s&s docs by 9am 6/22/26.start work 6/23/26. daily pe inspects. file w.in 48hr
Jun 18, 2026
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 28, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 28, 2016
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 28, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 28, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 28, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 28, 2016
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 28, 2016
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 28, 2016
Dob violation - active
Show 4 more ↓
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 31, 2014
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 17, 2014
Dob violation - active - Immediate emergency anythingoptional
Imegncy-immediate emergency anythingoptional
Oct 1, 2014
Dob violation - dismissed - Construction other optional
Failure to maintain building. front brick facade wall is detached from buidling with cracks around windows and crack at corner of exposure #1 & exposure #2. rear part of exposure #2 wall is cracking & bulging owner to immediately have licensed pe to evaluate entire buildingm, & obtain permit for repair. start repair work no later than 10/13/14
Sep 26, 2014
Dob violation - active
ECB violations · 33
- Class - 2
At the time of my inspection of a 4 story, i observed 2 workers on jobsite and at exposure #1 sidewalk shed in place that was not extended 5 feet as per code. failure to provide and maintain sidewalk shed as pe
Jul 9, 2026 · Penalty $2,430
Active - Class - 2
At the time of my inspection of a 4 story building, i observed 2 workers on jobsite and at exposure #4 rear yard, no overhead protection was provided to prevent demolition debris from falling onto adjacent prop
Jul 9, 2026 · Penalty $5,030
Active - Class - 2
At time of inspection observed finish floors removed exposing floor joists at 1st and 2nd floor framing ,several joists remove near expo.3 creating floor opening at 1st floor and makeshift wood reshore of exist
Jun 18, 2026 · Penalty $6,250
Active - Class - 1
At time of inspection observed soil with grade beams in place and exposed rebar for foundation work, reviewed job b01259917 ,gc failed to provide notification to department prior to commencement of work ., noti
Jun 18, 2026 · Penalty $12,500
Active - Class - 1
Work does not conform to the approved construction documents/approved amendments. as noted at the time of inspection, foundation work for a 4-story alteration building was in progress i observed at cellar level
Jun 16, 2026 · Penalty $12,500
Active - Class - 2
Atoi observed finish floors removed exposing floor joist at 1st and 2nd floor framing, several joist remove near exp3 creating floor opening at 1st floor and makeshift wood reshore of existing joist, not reflec
Jun 11, 2026
Resolve - Class - 1
Atoi observed exposed soil with grade beams in place and exposed rebar for foundation work,reviewed job b01259917,gc failed to provide notification to department prior to commencement of work., notify the depar
Jun 11, 2026
Resolve - Class - 2
Observed closed site with an installed sidewalk shed to protect the public from proposed 4-story building. upon inspection, a sidewalk shed parapet information panel was not displayed onto the sidewalk shed. re
Apr 27, 2026 · Penalty $6,250
Active - Class - 2
Observe shed with active permit on bis; permit not posted at site, contrary to bc 3301.9.1 - posting of permits. site inactive.
Mar 16, 2026 · Penalty $1,500
Active - Class - 2
At the time of inspection on a non active job site , i observed at exposure 1 & 4 that sidewalk shed was extended 5 feet or as per needed to adjacent property as per sidewalk shed plans # b01259917.z3 eq,001 -0
Mar 14, 2026 · Penalty $6,250
Active
Show 23 more ↓
- Class - 1
Removed or defaced a written posted vacate order.noted at time of inspection vacate order sticker was observed to have been removed.vacate order#445/16 issued on 09/28/2016.supplemental vacate order sticker#op-
Oct 9, 2025 · Penalty $12,500
Active - Class - 1
Failure to maintain building in a code compliant manner.note at the time of inspection observed damaged facade,missing/loose pieces of stucco exposing brick and spalling/missing brick allowing water to penetrat
Oct 9, 2025 · Penalty $6,250
Active - Class - 2
Failure to comply with the commissioner's order to file a certificate of correction with the department of buildings for ecb violation #35690632r issued on 05/27/2025. remedy: file a certificate of correction.
Aug 1, 2025 · Penalty $1,250
Active - Class - 1
Removed or defaced a written posted vacate order. noted: at time of inspection vacate order sticker was observed to have been removed. vacate order sticker was observed to have been removed. vacate order #445/1
Aug 1, 2025 · Penalty $12,500
Resolve - Class - 1
Failure to maintain building in a code-compliant manner. noted: at time of inspection observed observed damaged facade,: missing/loose pieces of stucco exposing brick and spalling/missing brick at exposure 2. p
Aug 1, 2025 · Penalty $6,250
Active - Class - 2
Failure to comply with the commissioner's order to file a certificate of correction with the department of buildings for ecb violation #35690631p issued on 05/27/2025. remedy: file a certificate of correction.
Aug 1, 2025 · Penalty $1,250
Active - Class - 1
Failure to maintain building in a code-compliant manner. noted: at time of inspection observed damaged facade missing/loose pieces of stuccoexposing the brick and spalling/missing brick at exposure #2. previous
May 27, 2025 · Penalty $2,500
Active - Class - 1
Removed or defaced a written posted vacate order. noted: at time of inspection, vacate order sticker was observed to have been removed, vacate order #445/16 issued 09/28/2016(supplemental vacate order sticker #
May 27, 2025 · Penalty $5,000
Resolve - Class - 1
At time of inspection, observed damaged facade missing/loose pieces of stucco, exposing the brick and spalling/missing brick at exposure #2. damaged facade non compliant to code.repair and/or replace damaged f
Jun 22, 2023 · Penalty $6,250
Active - Class - 1
Failure to maintain bldg in code compliant manner. lack of a system ofautomatic. lack of a system of automatic sprinklers where required perbc 903.1 & 27-954 for transient use. remedy: discontinue illegal occup
Sep 27, 2016
Resolve - Class - 1
Sec. 907.2.8 failure to maintain bldg in code compliant manner. failure to provide fire alarm system in hostel/transient occupied bldg. remedy: discontinue illegal occupancy.
Sep 27, 2016
Resolve - Class - 1
Failure to maintain bldg in code compliant manner failure to provide # of required means of egress for every fl per bc 1018.1 & 27-366 for hostel/transient occupied bldg. remedy: discontinue illegal occupancy.
Sep 27, 2016
Resolve - Class - 1
Work w/o a permit. noted at 3rd fl erected full height partitions creating 3 rms & 3 rms at cellar level installed water & waste lines at 3rd & cellar levels for 3pc bathroom(toilet,sink,shower)& residential
Sep 27, 2016
Resolve - Class - 1
Occupancy contrary to that allowed by the dob records indicates residence legally approved 2 family class'a'. illegal occupancy noted: at 2nd fl converted living area to sleeping w/bunk beds. also noted at cell
Sep 27, 2016 · Penalty $2,400
Active - Class - 1
Failure to maintain bldg in code compliant manner failure to comply w/maximum fl area requirements per occupant loas as per bc 1004.1.2,1004.1.2 umcs 27-2075 at cellar,1st,3rd floors converted/occupied as hoste
Sep 27, 2016
Resolve - Class - 1
Failure to maintain bldg walls or appurtenances. defects noted: at rear of bldg(exp#3)having 2 vertical cracks from roof level to foundation. side wall(rear exp#2)bulging & dislodging pieces of stucco in danger
Sep 27, 2016 · Penalty $1,000
Active - Class - 1
Removed or defaced a written posted vacate order #367114 issued on 10/3/14. remedy: comply w/code.
Sep 27, 2016 · Penalty $1,000
Active - Class - 1
1 or 2 family residence converted to or maintained as a dwelling for 4 or more families. dob records indicates residence legally approved 2 family class'a'dwellings. residence now altered & occupied 7 family by
Sep 27, 2016 · Penalty $47,400
Active - Class - 2
Failure to comply with the commissioner's oder to file a certificate of correction with the dob for ecb ecb viol.#35097594h.rem:file a certificate of correction.
Nov 15, 2014 · Penalty $2,000
Resolve - Class - 2
Failure to comply w/ the commissioner's order to file a certificate ofcorrection w/ the dept. of bldg for notice of vio. # 35111805r issued on 09/25/14 pursuant to 28-204.4 & 1rcny 102-01. failure to maintain f
Oct 29, 2014 · Penalty $2,000
Resolve - Class - 1
Failure to maintain building in a code compliant manner.note:at the north and east side exterior walls brick facade are defective and bulging with an inadequate patch/repair in place.primary egress (front doo
Oct 3, 2014 · Penalty $1,000
Active - Class - 1
Failure to maintain noted front exterior facade separating at exposure1 & 2 meet the front wall is uneven & a(have)condition is evident. have licensed p.e. evaluate entire structure & provide report.
Sep 25, 2014 · Penalty $5,000
Active - Class - 2
Work w/o a permit. noted at rear yard installation of combustable wooddeck from lot line to lot time along w/a wood combustable shed built above it. remedy: obtain permits restore to prior legal conditions.
Sep 25, 2014 · Penalty $4,000
Active
Complaints
- Heating
Heat related
Jan 30, 2014 · Apt 1
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Walk-up apartment building (C0)
- Year built
- 1899
- Floors
- 2
- Residential units
- 3
- Building area
- 2,047 ft²
- Lot area
- 1,584 ft²
- Zoning
- R6
- Community board
- 302
- Council district
- 35
- Block / lot
- 2027 / 22
- Assessed value
- $102,720
- Landmark / historic district
- No
Questions about 9 North Elliott Place
Who owns 9 North Elliott Place?
The owner of record in NYC Department of City Planning PLUTO data is Nkrt Brooklyn NY LLC.
Does 9 North Elliott Place have violations?
NYC HPD has no housing violations on record for this property.
Is 9 North Elliott Place rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 9 North Elliott Place built?
City records list 1899 as the year it was built.
How many apartments are in 9 North Elliott Place?
It has 3 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.