Violations at 227 7 Avenue

Brooklyn, NY 11215 · BBL 3-01082-0001 · Back to the property

HPD housing violations

No HPD violations on record

DOB building violations

The newest 50 of 72 DOB violations. The city keeps the complete history.

  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 4, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 4, 2019

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - active
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator - failure to file category 1 2017 inspection/test

    Apr 5, 2019

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator - failure to file category 1 2017 inspection/test

    Apr 5, 2019

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator - failure to file category 1 2017 inspection/test

    Apr 5, 2019

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator - failure to file category 1 2017 inspection/test

    Apr 5, 2019

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 19, 2018

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 22, 2017

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2015 inspection report

    Feb 24, 2017

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2015 inspection report

    Feb 24, 2017

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2015 inspection report

    Feb 24, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst

    Nov 14, 2016

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 27, 2016

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 27, 2016

    Dob violation - resolved
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst

    May 30, 2014

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst

    May 30, 2014

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2010 inspection/test

    Dec 13, 2011

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 3, 2011

    Dob violation - resolved
  • Elevator annual inspection / test elevatorrequired

    Vcat1-elevator annual inspection / test elevatorrequired

    Oct 8, 2010

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 1, 2010

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 1, 2010

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 24, 2009

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 24, 2009

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 30, 2008

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 12, 2008

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 4, 2007

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 4, 2007

    Dob violation - resolved
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Apr 2, 2007

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 6, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 6, 2006

    Dob violation - resolved
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Oct 1, 2005

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 5, 2005

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 5, 2005

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 11, 2004

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 11, 2004

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 28, 2003

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 28, 2003

    Dob violation - resolved
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Mar 21, 2003

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Feb 19, 2002

    Dob violation - dismissed
  • Elevator elevatorrequired

    3p6289

    Aug 15, 2001

    Dob violation - resolved
  • Elevator elevatorrequired

    3f5413

    Jul 21, 2000

    Dob violation - resolved
  • Elevator elevatorrequired

    3p6289

    Jul 21, 2000

    Dob violation - resolved
  • Construction other optional

    C-construction other optional

    May 28, 1999

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Jan 6, 1998

    Dob violation - dismissed

ECB violations

The newest 50 of 247 ECB violations. The city keeps the complete history.

  • Class - 2

    Failure to maintain building in code-compliant manner.no firestopping per bc 712.3;27-345.at the time of inspection,there were multiple through floor penetration open.application for work types are renew but fi

    Apr 3, 2026 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner.the following rooms with 2nd exit doors from classrooms were blocked/nailed shut:302,300,320,324,328,234,240,241,245,247,251,208,204,209,214,211,216,218,229

    Apr 3, 2026 · Penalty $3,125

    Active
  • Class - 2

    Stair and/or floor identification signs missing and/or defective.at the time of inspection multiple exit discharge doors do not have designation,these include discharge door off cafeteria exit#14 vestibule/disc

    Apr 3, 2026 · Penalty $625

    Active
  • Class - 2

    Exit door not self-closing.at the time of inspection,the following exit discharge doors were not self-closing:exit#14,discharge door off cafeteria,exit 11/13.rem:repair/replace door.

    Apr 3, 2026 · Penalty $625

    Active
  • Class - 2

    Reissue#35691958l failure to maintain building in code-compliant manner.at the time of inspection,the marble flooring at exit discharge 7 and 9 were cracked/shattered window panel next to exit 17 stair on 4th f

    Apr 3, 2026 · Penalty $3,125

    Active
  • Class - 2

    Reissue#35655082h at the time of inspection,the following room/spaces had efflorescence/spalling/leaks/buldging staircase l bulkhead,room 404,410,424,staircase 2/exit 4 on 4th fl,438,443,445,460,336,348,302,314

    Apr 3, 2026 · Penalty $3,125

    Active
  • Class - 2

    Reissue#35691959n at the time of inspection,the commercial gas stove used in cafeteria was not equipped with an ansul system.rem:repair and/or replace.

    Apr 3, 2026 · Penalty $3,125

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner.illumination forexits,exit discharges and public corridors per bc 1006.1;27-381.at thetime of inspection,emergency light in corridor next to 1st floor gym w

    Apr 3, 2026 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner.use of prohibited door and/or hardware per bc 1008.1.8;27-371(j).at the time of inspection,the following doors had turn knob handles-401,403,405,411,416,,ki

    Apr 3, 2026 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner.at the time of inspection,the following doors were not self-closing corridor door nextto 408,staircase 11 on 4th floor 402,416 corridor doors next to 414,44

    Apr 3, 2026 · Penalty $1,250

    Active
  • Class - 2

    Failure to comply with the commissioner's order to file a certificate of correction with the department of buildings. no certificate of correction on file for vio#39095380z as of 1/16/26.., file a certificate o

    Jan 16, 2026 · Penalty $6,250

    Active
  • Class - 2

    Failure to certify for certificate of corrections for summons #39095380z., file a certificate of correction

    May 8, 2025 · Penalty $625

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner. noted: a leak from the roof above is causing water damage a mold to grow on the wallsat room #424. remedy: repair/replace.

    Apr 11, 2025 · Penalty $1,250

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner. noted: the poollocker room has peeling, chipping and mold developing through out the ceiling and walls. remedy: repair/replace.

    Apr 11, 2025 · Penalty $1,250

    Resolve
  • Class - 2

    Re-issue #35657643h. failure to maintain building in code-compliant manner. noted: at t. o. i. the commercial gas stove in the kitchen does not have the ansul. remedy: comply with notice of the violation.

    Apr 11, 2025 · Penalty $3,125

    Active
  • Class - 2

    Re-issue #35657644j. failure to maintain building in code-compliant manner. noted: the marble flooring at exit 7 on first fl. and at exit 9 on the first floor is cracked, chipped with holes all over the floor.

    Apr 11, 2025 · Penalty $3,125

    Active
  • Class - 2

    Observed debris chute attached to existing supported pipe scaffold. debris chute height approximately 55ft high. upon review the department records ( bis & dob now) did not observe any active permit to install

    Mar 15, 2025

    Resolve
  • Class - 2

    A8-i observed 2 workers moving 2 vertical sws supports at the corner of 5th st & 7th avenue, approx 12" apart from their original location, contrary to the approved sca drawings page eq-003.00 & eq-006.00 for s

    Sep 20, 2023 · Penalty $3,125

    Resolve
  • Class - 1

    I observed 2 workers moving 2 vertical sws supports at the corner of 5th st & 7th avenue, approx 12" apart from their original location. upon dob research, this work was outside the description of work on the a

    Sep 20, 2023 · Penalty $6,250

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner:noted:on 1st fl next to room 145, 150 on second floor next to room 210,208,248 on 3rd fl next to room 312, on 4th fl next to room 462.all doors not closing

    Feb 14, 2023 · Penalty $625

    Resolve
  • Class - 2

    Reissue #35655086p failure to maintain building in code compliant manner.noted:observed on 1st fl at exit 7 & 9 floor has cracks & holes at various locations throughout.remedy:repair and/or replace.

    Feb 14, 2023 · Penalty $1,562

    Active
  • Class - 2

    Reissue #35655085n failure to maintain building in code-compliant manner.noted:at cafeteria kitchen commerical gas stove does not have ansul system.remedy:repair and/or replace

    Feb 13, 2023 · Penalty $1,562

    Active
  • Class - 2

    Reissue #35561282p(4/30/21)failure to maintain building in code compliant manner no fire stopping per bc 7123;27-345 at cellar pipes cable penetrated through walls foundation without fireproofing.remedy:mainta

    Apr 21, 2022 · Penalty $3,125

    Resolve
  • Class - 2

    Reissue #35561275r(4/30/21)failure to maintain building in code compliant manner at 1st floor exit 7,9 marble floor cracked with holes plus defective.remedy:repair/replace

    Apr 21, 2022 · Penalty $1,562

    Active
  • Class - 2

    Reissue #35561276z(4/30/21)failure to maintain building in code compliant manner at cafeteria kitchen commercial stove does not have ansul systems.remedy:repair/replace & comply with notice of violations.

    Apr 21, 2022 · Penalty $1,562

    Active
  • Class - 2

    Reissue #35561277k(4/30/21)failure to maintain building in code complaint manner at cellar water penetration floods in several areas deteriorated foundation walls.remedy:repair/replace & comply with notice of v

    Apr 21, 2022 · Penalty $1,562

    Resolve
  • Class - 2

    Reissued #35561278m(4/30/21)failure to maintain building in code compliant manner illumination for exits exit discharges & public corridors per bc 1006.1;27-381 emergency lights are not operational when tested

    Apr 21, 2022 · Penalty $1,562

    Resolve
  • Class - 2

    Reissue #35561279y(4/30/21)failure to maintain building in code compliant manner at 4th, 3rd, 2nd & 1st floors water damage to walls & ceilings due to water penetration through pipes.remedy:repair and/or replac

    Apr 21, 2022 · Penalty $1,562

    Active
  • Class - 2

    Reissue #35561280l(4/30/21)failure to maintain building(in code compliant)walls or appurtenances at courtyards/school yard detaining walls stones & mortars detachment plus bulging outward.remedy:maintain exteri

    Apr 21, 2022 · Penalty $3,125

    Active
  • Class - 2

    Reissue #35561281n(4/30/21)exit door not self closing at 5th street sides(exp #4)not close properly dut to deteriorated conditions from elements including hinges & hardware plus bottom doors several smoke doors

    Apr 21, 2022 · Penalty $1,562

    Resolve
  • Class - 2

    Failure to obtain temp permit prior to installation/use of temp equipment observed sws erected@exp2 no active permit issued on bis/dobnow for sws obtain temp const permit

    Mar 24, 2022 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain bldg in code compliant manner: no fire stopping per bc 712.3;27-345. noted: at cellar level,pipes,cables penetrating through block wall on different locationon. remedy: provide/maintain fire

    Apr 30, 2021 · Penalty $1,250

    Resolve
  • Class - 2

    Exit door not self closing. noted: at exp#4(5th street)existing emergency exit doors not closing properly,sheet metal detachment & corrision due to flooding & maintenance,also smoke doors on different locations

    Apr 30, 2021 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain bldg walls or appurtenances. noted: at exp#4(5th st)retaining wall in stone has bulging,detachment of stones & mortar,generating instability to the metal fence & emergency staircase supporte

    Apr 30, 2021 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain bldg in code compliant manner: noted: damage to walls,ceiling & pipe insulation due to water penetration at 4th fl(rm 416,418,420);3rd fl(rm 322,320,318)2nd fl(rm 220 next to rm 218)1st floo

    Apr 30, 2021 · Penalty $625

    Active
  • Class - 2

    Reissue#35495118k failure to maintain bldg in code compliant manner: illumination for exits,exit discharges & public corridors per bc 1006.1;27-381. noted: at the cafeteria,hallways,stairs;existing emergency li

    Apr 30, 2021 · Penalty $1,562

    Resolve
  • Class - 2

    Reissue35495119m failure to maintain bldg in codecompliant manner:noted:@cellar level,flooding in diff storage rms&bathrm due to water leaksor water penetration thru foundation walls,causing deterioration in ma

    Apr 30, 2021 · Penalty $1,562

    Resolve
  • Class - 2

    Reissue35495116r failure to maintain bldg in codecompliant manner:noted:@1fl level,kitchen rear commercial gas dont have ansul system.repair&/or replace.

    Apr 30, 2021 · Penalty $1,562

    Active
  • Class - 2

    Reissue35495117z failure to maintain bldg in codecompliant manner:noted:@exp3 interior facade:on diff level fls,cornice&stone lintels have cracks,detachment,holes in diff location.repair &/or replace.

    Apr 30, 2021 · Penalty $1,562

    Active
  • Class - 2

    Reissue#35422484n failure to maintain bldg in code compliant manner. noted: at cellar level there's water on the floor due to a leaking bathroom drain pipe. remedy: repair &/or replace.

    Apr 29, 2020 · Penalty $1,562

    Resolve
  • Class - 2

    Reissue#35422480x failure to maintain bldg in a code compliant manner:illumination for exits,exit discharges & public corridors per bc 1006.1;27-381. noted: the emergency light throughout the bldg were not work

    Apr 29, 2020 · Penalty $1,562

    Resolve
  • Class - 2

    Reissue#35422481h failure to maintain bldg in code compliant manner: noted: on the 1st fl at exit#7 & 9 the marble floor is cracked. remedy:repair &/or replace.

    Apr 29, 2020 · Penalty $1,562

    Active
  • Class - 2

    Reissue#35422483l failure to maintain bldg in code compliant manner. noted: at 1st fl kitchen rear(10)carrier commercial gas store do not have an ansul system. remedy: provide ansal system.

    Apr 29, 2020 · Penalty $1,562

    Active
  • Class - 2

    Restore service to device

    Jan 14, 2020 · Penalty $625

    Resolve
  • Class - 2

    Restore service to device

    Jan 14, 2020 · Penalty $625

    Resolve
  • Class - 2

    Restore service to device

    Jan 14, 2020 · Penalty $625

    Active
  • Class - 1

    Cease use item: damaged disc brake monitor class 2 items: replace worn hoistway door gibs where needed. secure hoistway door gibs where needed. replace car door gibs where needed. unguarded cab lighting. worn c

    Jan 14, 2020 · Penalty $1,250

    Resolve
  • Class - 2

    Restore service to device

    Jan 14, 2020 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner use of prohibited door and or hardware per bc 1008.1-8 27-371(j) noted at auditorium al th emain doors are attached with kick down door holders.provide lega

    May 6, 2019 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner.noted:@cellar standing water due to bathrom drain pipe leak.rem: repair/replace.

    May 6, 2019

    Resolve