255 18 Street

Brooklyn, NY 11215BBL 3-00873-0069Map

Owner of record: Eighteen Properties LLC

255 18 Street is an elevator apartment building built in 1905 in Brooklyn, 11215. It has 36 residential units across 4 floors. The owner of record is Eighteen Properties LLC. HPD has recorded 48 housing violations here, most recently on April 29, 2026. 12 of the 48 most recent violations are still open.

HPD violations
48
DOB violations
91
ECB violations
210
HPD complaints
50

Available now in this building

What to know

Concern
3 open Class C

Immediately hazardous issues among recent violations are still open.

Good
Last violation Apr 29, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 48

  • B

    Properly repair the source and abate the evidence of a water leak .at the wood window frame 1st from north at east, in the 3rd room from north at east located at apt 401, 4th story, 1st apartment from east at south

    Apr 29, 2026 · Apt 401

    Open — Nov sent out
  • B

    Properly repair with similar material the broken or defective wood window frame 1st from north at east., in the 3rd room from north at east located at apt 401, 4th story, 1st apartment from east at south

    Apr 29, 2026 · Apt 401

    Open — Nov sent out
  • C

    M/d law abate the nuisance consisting of metal nail protruded out with shaped edges at the concrete floor in the 1st room from north at east located at apt 401, 4th story, 1st apartment from east at south

    Apr 29, 2026 · Apt 401

    Open — Nov sent out
  • C

    M/d law abate the nuisance consisting of metal nail protruded out with shaped edges at the concrete floor , in the private hallway located at apt 401, 4th story, 1st apartment from east at south

    Apr 29, 2026 · Apt 401

    Open — Nov sent out
  • C

    M/d law abate the nuisance consisting of hot water exceeded allowed temperature of the 130.f degrees at hotwater fixtures, in the entire apartment located at apt 401, 4th story, 1st apartment from east at south

    Apr 29, 2026 · Apt 401

    Closed — Violation closed
  • B

    Repair, replace or provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations defective in the entire apartment located at apt 401, 4th story, 1st apartment from east at south

    Apr 29, 2026 · Apt 401

    Open — Nov sent out
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at the south wall, in the 3rd room from north at west located at apt 401, 4th story, 1st apartment from east at south

    Apr 29, 2026 · Apt 401

    Open — Nov sent out
  • B

    Repair the roof so that it will not leak over ceiling in the 4th room from north located at apt 401, 4th story, 1st apartment from east at south

    Feb 19, 2026 · Apt 401

    Open — Nov sent out
  • B

    Properly repair or replace the broken or defective counter balance at upper window sash at east wall in the 4th room from north located at apt 401, 4th story, 1st apartment from east at south

    Feb 19, 2026 · Apt 401

    Open — Nov sent out
  • B

    Repair, replace or provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules defective in the entire apartment located at apt 401, 4th story, 1st apartment from east at south

    Feb 19, 2026 · Apt 401

    Open — Nov sent out
Show 38 more ↓
  • B

    Repair, replace or provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations defective in the entire apartment located at apt 401, 4th story, 1st apartment from east at south

    Feb 19, 2026 · Apt 401

    Open — Nov sent out
  • C

    Provide an adequate supply of gas to the fixtures at gas range in the kitchen located at apt 401, 4th story, 1st apartment from east at south

    Feb 19, 2026 · Apt 401

    Closed — Violation closed
  • B

    Properly repair or replace the broken or defective counter balance at upper window sash at east wall in the 5th room from north at east located at apt 401, 4th story, 1st apartment from east at south

    Feb 19, 2026 · Apt 401

    Open — Nov sent out
  • C

    Provide an adequate supply of heat for the apartment in the entire apartment located at apt 206, 2nd story, 1st apartment from east at south

    Jan 3, 2026 · Apt 206

    Closed — Violation closed
  • C

    Provide an adequate supply of heat for the apartment in the entire apartment located at apt 401, 4th story, 1st apartment from south at west

    Jan 3, 2026 · Apt 401

    Open — Nov sent out
  • C

    Replace or repair the self-closing doors that is missing or defective hinges, in the entrance located at apt 201, 2nd story, 1st apartment from east at south

    Dec 31, 2024 · Apt 201

    Closed — Violation dismissed
  • C

    Remove device preventing door from being self-closing fire extinguisher setted and obstructed entrance door to fire stair 1st from west at north, at public hall, 2nd story

    Dec 31, 2024

    Closed — Violation dismissed
  • C

    Remove device preventing door from being self-closing fire extinguisher setted and obstructed vestibule door, at public hall, 1st story

    Dec 31, 2024

    Closed — Violation dismissed
  • C

    Remove device preventing door from being self-closing plastic wedge jammed and obstructed entrance door to fire stair 1st from west at north, at public hall, 1st story

    Dec 31, 2024

    Closed — Violation dismissed
  • A

    Post, in a form approved by the commissioner, and maintain a notice in a common area of the building regarding the procedures that should be followed when a gas leak is suspected

    Dec 31, 2024

    Closed — Violation dismissed
  • A

    Post and maintain a proper notice on wall of the entrance story in english and spanish on the availability of the agencys housing information guide. a sample notice can be found at www.nyc.gov/hpd. at public hall, 1st story

    Dec 31, 2024

    Closed — Violation dismissed
  • B

    Remove all encumbrances consisting of household artarticles throughout, at public hall, 2nd story

    Dec 31, 2024

    Closed — Violation dismissed
  • B

    Properly repair or replace the broken or defective hinges at door, in the entrance located at apt 204, 2nd story, 2nd apartment from east at south

    Dec 31, 2024 · Apt 204

    Closed — Violation dismissed
  • C

    M/d law abate the nuisance consisting of hotwater exceeded maximum allow temperature of 130.f degrees at hotwater fixtures, in the entire apartment located at apt 204, 2nd story, 2nd apartment from east at south

    Dec 31, 2024 · Apt 204

    Closed — Violation dismissed
  • C

    Provide hot water at all hot water fixtures in the 1st room from north located at apt 201, 2nd story, 1st apartment from east at south

    Dec 31, 2024 · Apt 201

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 3, 2024

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Feb 22, 2022

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Feb 22, 2022

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 6, 2021

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 12, 2018

    Closed — Violation dismissed
  • C

    Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system sign missing at wall at public hall, 1st story

    Oct 20, 2017

    Closed — Violation closed
  • A

    Post sign on wall of entrance story bearing name, address including apartment number if any, and telephone number of superintendent, janitor or housekeeper. at public hall, 1st story

    Oct 20, 2017

    Closed — Violation closed
  • A

    Post, in a form approved by the commissioner, and maintain a notice in a common area of the building regarding the procedures that should be followed when a gas leak is suspected at public hall, 1st story

    Oct 20, 2017

    Closed — Violation closed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 1, 2016

    Closed — Violation dismissed
  • A

    Provide place within the building for the storage of waste receptacles and disinfect same regularly.

    Oct 19, 2016

    Closed — Violation closed
  • A

    File with this department a certification that the person doing janitorial services is competent to perform same.

    Oct 19, 2016

    Closed — Violation closed
  • A

    § 329, m/d law and dept. rules and regs. provide a completed certificate of inspection visits in a proper frame at or near mailboxes, bottom edge of frame between 48-62 inches above floor , frame missing at public hall, 1st story

    Oct 19, 2016

    Closed — Violation closed
  • A

    Post and maintain a proper sign on wall of entrance story showing the registration number assigned by the department and the address of the building. at public hall, 1st story

    Oct 19, 2016

    Closed — Violation closed
  • A

    Post a proper notice of carbon monoxide detecting device requirements, in a form approved by the commissioner, in a common area of a class a multiple dwelling near inspection certificate or provide notice to tenants in a private dwelling. at public hall, 1st story

    Oct 19, 2016

    Closed — Violation closed
  • A

    Post a proper notice of smoke detector requirements, in a form approved by the commissioner, at or near the mail box , at public hall, 1st story

    Oct 19, 2016

    Closed — Violation closed
  • A

    Post and maintain a proper notice on wall of the entrance story in english and spanish on the availability of the agencys housing information guide. a sample notice can be found at www.nyc.gov/hpd. at public hall, 1st story

    Oct 19, 2016

    Closed — Violation closed
  • C

    Remove the accumulation of refuse and/or rubbish and maintain in a clean condition the garbage approx 15 cubic yards at west loading bay , 1st story

    Oct 19, 2016

    Closed — Violation closed
  • A

    Post a sign indicating hours of collection and method of collection of waste material where dumbwaiter service is not provided.

    Oct 19, 2016

    Closed — Violation closed
  • B

    Provide sufficient, proper and separate metal receptacles for the deposit of garbage, rubbish and other waste material and arrange for collection and disposal of such material.

    Oct 19, 2016

    Closed — Violation closed
  • A

    Post sign on wall of entrance story bearing name, address including apartment number if any, and telephone number of superintendent, janitor or housekeeper.

    Oct 19, 2016

    Closed — Violation closed
  • C

    Provide dwelling with a janitor or responsible person or janitorial service.

    Oct 19, 2016

    Closed — Violation closed
  • B

    Repair the roof so that it will not leak over ceiling in the 1st room from north located at apt 408, 4th story, 4th apartment from south at west

    Nov 25, 2014 · Apt 408

    Closed — Violation closed
  • B

    Properly repair with similar material the broken or defective metal door frame at 2nd building entrance from east at public hall, 1st story

    Jun 28, 2014

    Closed — Violation closed

DOB building violations · 91

  • Construction other optional

    Observed structural alterations performed at exposure-1 of cellar level/sidewalk vault not indicated on or conforming with any approved plans. no applicable structural filings for conditions, structural stability unknown. as such, full structural stability assessment of property is required to be submitted to department of buildings within

    Aug 6, 2026

    Dob violation - active
  • Plumbing none

    Failure to maintain building in code complaint manner. sewer main in cellar is clogged and leaking

    Aug 8, 2025

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 23, 2024

    Dob violation - dismissed
  • Failure to post energy grade/score none

    Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3

    Dec 1, 2024

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 2, 2022

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 6, 2021

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 6, 2021

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 6, 2021

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 2, 2020

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 2, 2019

    Dob violation - dismissed
Show 40 more ↓
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 9, 2019

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Apr 17, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Feb 6, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Feb 6, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 9, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 9, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 9, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 9, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 9, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 31, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 19, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 19, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 5, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 25, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    May 30, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    May 16, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    May 16, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 13, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 20, 2017

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 18, 2017

    Dob violation - resolved
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 6, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 9, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 9, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 26, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 26, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 26, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 26, 2017

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 7, 2017

    Dob violation - resolved
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 22, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 22, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 22, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 22, 2017

    Dob violation - dismissed
  • Construction other optional

    Provide light and ventilation for rear apartments as required by code

    Feb 2, 2017

    Dob violation - dismissed
  • Construction other optional

    Provide light and ventilation for rear apartments as required by code

    Feb 2, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 7, 2015

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 22, 2014

    Vw*-violation - work w/o permit dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 28, 2013

    Dob violation - resolved
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2011 inspection report

    Mar 1, 2013

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2011 inspection/test

    Oct 1, 2012

    Dob violation - dismissed

ECB violations · 210

  • Class - 2

    Atoi of a 4 story building i gained access to apt 305 by occupant. observed 2 hole penetrations with 2 hvac lines and 1 gas dryer vent leading into seperate locations. per b202 class 2 28-301.1 failure to maint

    Oct 14, 2026 · Penalty $1,250

    Active
  • Class - 2

    Failure to comply with the commissioner's order to file a certificate of correction with the department of buildings for summons #39181184m., file a certificate of correction

    Oct 1, 2026 · Penalty $1,250

    Active
  • Class - 1

    Unlawful acts. failure to comply with commissioner's order to obtain permits for vio # 39155917l., comply with commissioner's order

    Oct 1, 2026 · Penalty $2,500

    Active
  • Class - 2

    Failure to comply with the commissioner's order to file a certificate of correction with the department of buildings for summons # 39170880m., file a certificate of correction

    Oct 1, 2026 · Penalty $1,250

    Active
  • Class - 3

    Atoi, observed nov#'s 39204516z, 39204517k, 39181184m, 39168774x, 39162654y, 391609538p, 39155917l, 39155918n, was not posted in lobby as per ll110of2019. did not observe nov that relates to a violating conditi

    Sep 29, 2026 · Penalty $500

    Active
  • Class - 3

    Atoi, nov# 3920558l (apt 302), 39201609y (apt 302), 39204515r (apt 301) , 39187410z (apt 308), 39187360j (apt 308), 39170880m (apt 206), 39155732p apt 209/308), 39154320y (apt 308)was not dist. to resident of o

    Sep 29, 2026 · Penalty $500

    Active
  • Class - 3

    Failure to maintain building in code-compliant manner. observed at emergency staircase a, cracks/chipping at various stair risers at fls, 4,2,1,cellar. this causes a potential slip/ trip hazard in an emergency

    Sep 29, 2026 · Penalty $500

    Active
  • Class - 1

    Cease use item: inoperative zone lock restrictor (2.14.5.7.1.). class 2 items: provide signage, located in a conspicuous location, indicating location of controller room (fdny requirement). provide group 2 secu

    Sep 25, 2026 · Penalty $3,125

    Active
  • Class - 1

    Atoi observed electrical work without a permit at unit 302. new electrical ceiling fan being installed in the dining/kitchen area. no electrical permit found for the work. unpermitted electrical work presents a

    Sep 24, 2026 · Penalty $2,500

    Active
  • Class - 2

    Electrical work without a permit. observed in apt 301 the installation of new lighting, receptacles, new electrical panel and breakers. all work completed 100%. in the cellar new exit signs installed in gym, bi

    Aug 24, 2026 · Penalty $1,250

    Active
Show 40 more ↓
  • Class - 2

    Work does not conform to application #322066072. at time of inspectionobserved: (1)354.0 sf existing accessory storage rm. found as decommissioned boiler rm. (2)wall configuration errected enclosing cellar aban

    Aug 24, 2026 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain building in a code-compliant manner. at time of inspection observed: (1)lack of fall protection, no railings or guardrails installed around approx. 3' elevated platforms and stairs located a

    Aug 24, 2026 · Penalty $1,250

    Active
  • Class - 2

    Unapproved/unsafe/unsuitable electrical equipment, materials. observed in the cellar in the main electrical rm the 70 amp 2 pole breaker feeding apt 306 is warm to the touch. it is now in a state of failure pot

    Aug 24, 2026 · Penalty $800

    Active
  • Class - 2

    Miscellaneous violation of the electrical code technical standards. observed in the cellar the lack of emergency lights to egress the gym, the storage rm, and all sitting areas. in stairway b no em lights are p

    Aug 24, 2026 · Penalty $800

    Active
  • Class - 2

    Failure to maintain, i observed improper ventilation to meter room, duct exceeds 15 ft to the outside, prohibited as per appendix e.4. and open-ended gas valve and waste piping in apt 302 and improper sprinkler

    Aug 24, 2026 · Penalty $1,250

    Active
  • Class - 2

    Provide signage, located in a conspicuous location, indicating location of controller room (fdny requirement). provide group 2 secuity lock for controller room door (2.7.3.4.4). shorten governor rope (2.18.5).

    Jun 16, 2026

    Resolve
  • Class - 2

    For work contrary to plans job 322066072 field conditions for apartment 308 not conforming to plans regarding location of heat hot water tank and kitchen soffit. job# 322066072 indicates soffit to be in kitchen

    Apr 23, 2026

    Resolve
  • Class - 2

    For work contrary to plans job# 322066072 field conditions for apartment 308 not conforming to plans regarding location of heat tank and kitchen soffit. job#322066072 indicates soffit to be in kitchen, and hot

    Apr 23, 2026 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain, in unit 308 the gas fired hvac unit installed above the bathroom does not have the service door. the safety switch has been taped down to over ride the door being removed. the unit in place

    Apr 15, 2026

    Resolve
  • Class - 2

    Failure to maintain. in unit 308 the gas fired hvac unit installed above the bathroom does not have the service door. the safety switch has been taped down to override the door being removed. the heating unit n

    Apr 15, 2026 · Penalty $1,250

    Active
  • Class - 1

    Atoi, observed at roof level of premises. steel pipe railing installed on parapet wall on all exposures, contrary to plan as per fc 504.4.4(4). placement of railing is contrary to plan, railing was to be instal

    Mar 19, 2026 · Penalty $2,500

    Active
  • Class - 2

    Atoi observed active tpp # b01259468-i1-gc/ b01288506-i1-st not posted or present anywhere on premises. tpp must be posted for notification of work being done at premises., post/distr. notice

    Mar 19, 2026 · Penalty $1,250

    Resolve
  • Class - 1

    Atoi, observed ar roof level bulkhead of premises, near dunnage, debris, chair and clothing left on bulkhead. can be picked up by wind/ weather causing flying objects, potentially hurting the public. also, othe

    Mar 19, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    Atoi observed active permit # b01288506-i1-st, expiring 05/01/2026. not posted anywhere on premises, or in a conspicuous place for public viewing. post all active permits., post/properly post permit

    Mar 19, 2026

    Resolve
  • Class - 2

    I observed in basement laundry room a sprinkler head obstructed with paint. painted sprinkler heads causes the head to not function according to design. as per bc 903.3.3 sprinkler heads should be free from obs

    Mar 4, 2026

    Resolve
  • Class - 2

    Failure to file certificate of correction, summons # 39155715n issued on 8/1/2025 had a hearing date 10/8/2025 resulted in default judgment. the respondent has taken no steps towards corrective action. no certi

    Dec 31, 2025 · Penalty $1,250

    Resolve
  • Class - 1

    Observed in apt.206 as per under job # 32206672, drawing # a- 003.01 clearly indicates 2 hour fire rating to be maintained for exiting elevator shaft throughout ( 1968 b.c 3-4)due to holes around components and

    Dec 18, 2025 · Penalty $2,530

    Active
  • Class - 3

    In apt 306 hvac unit in ceiling has a clogged condensate drainýcondensate in air duct¨;ýlicense plumber required¨+the light fixture is missing in bedroom closetýopen wire box¨;ýlicensed electrician required¨, m

    Dec 12, 2025

    Resolve
  • Class - 2

    Restore complete car communications. adjust hoistway door access hole at top landing. provide explicitly detailed info, posted in a conspicuous location, on how/where to obtain access to both basement level and

    Dec 1, 2025

    Resolve
  • Class - 2

    A8: failure to secure/support electrical fdr & armored cable in apartment #206 overhead storage area., properly secure/support emt; properly secure/support cables.

    Dec 1, 2025 · Penalty $530

    Active
  • Class - 1

    Observed one gas fired hvac unit in apartment 308.. ceased use due to hazardous conditions. flue pipe not connected to the unit. do not operate the unit until all hazardous conditions are immediately corrected

    Oct 6, 2025 · Penalty $2,500

    Active
  • Class - 2

    1) provide a sign in the lobby (by the elevator door) that states the location of the control room. 2) pin the final limits 3) provide a number on the runby sign. 4) remove wood from the pit. 5) this elevator h

    Sep 18, 2025 · Penalty $1,592

    Active
  • Class - 2

    I observed in apartment 308,above bathroom a gas fired furnace not properly installed. furnace is missing vent and exhaust piping and as per fgc 503.2 appliances shall be connected to a venting system. no exhau

    Sep 9, 2025 · Penalty $1,280

    Resolve
  • Class - 2

    Electrical work without a permit. at time of inspection observed 2 workers on ladders doing electrical work with armored cables in the cellar no electrical permit on file for such work stop all electrical work,

    Aug 20, 2025

    Resolve
  • Class - 2

    A8 : unapproved/unsafe/unsuitable electrical equipment, apparatus, materials, devices, appliances or wiring in use. in apt#308 & 209 armored cable supported on sprinkler. apt 305 defective wiring switch & outle

    Jul 24, 2025 · Penalty $2,000

    Resolve
  • Class - 1

    Observed approximately 15 ft of egress hallway without automatic sprinkler coverage on 1st and 2nd floors., provide a system of automatic sprinklers where required

    Jul 24, 2025 · Penalty $6,250

    Resolve
  • Class - 2

    A8: unapproved/unsafe/unsuitable electrica wiring. in use, apt #308 & 209 armored cable supported on sprinkler pipe. apt# 305 def outlets and switches in bathroom. stair way b broken fixture globe. electric ser

    Jul 24, 2025 · Penalty $400

    Resolve
  • Class - 1

    I observed dedicated standpipe / sprinkler piping not painted red in cellar and in apartment 301 as per bc 903.6.1. dedicated sprinkler/standpipe shall be painted red., repair and/replace

    Jul 24, 2025 · Penalty $6,250

    Resolve
  • Class - 2

    Failure to maintain building & parts thereof in a code compliant manner: atoi the rigid vent connection in the kitchen at apt # 305 was observed disconnected with sections missing., repair and/or replace; repai

    Jul 24, 2025 · Penalty $3,125

    Resolve
  • Class - 1

    Work without a permit: atoi no work permit on file for mechanical dunnage installed at top of bulk., obtain permit; obtain all necessary work permit/s.

    Jul 24, 2025 · Penalty $2,500

    Resolve
  • Class - 2

    Work does not conform to approved construction documents &/or approved amendments: atoi the kitchen cfm extractor fan & rigid flue pipe is not soffitted as proposed on dob job # b00389905. condition observed in

    Jul 24, 2025 · Penalty $3,125

    Resolve
  • Class - 2

    Failure to maintain building & parts thereof in a code compliant manner: atoi the penetrations in the stairwell landings that facilitates the standpipe were observed lacking fire stopping per bc 714.3.1.1-bc 71

    Jul 24, 2025 · Penalty $3,125

    Resolve
  • Class - 1

    Failure to maintain building & parts thereof in a code compliant manner: atoi the parapet at the roof level does not meet the required 42" inches as proposed in dob job #'s 322066072 & b00389905. no 18" inch ra

    Jul 24, 2025 · Penalty $6,250

    Resolve
  • Class - 1

    Work without a permit: atoi at cellar in electrical room, load bearing cmu wall demolished to grade. new steel girders with 4" inch tubular steel columns & q-decking installed. no work permit/s or appvls on fil

    Jul 24, 2025 · Penalty $2,500

    Active
  • Class - 1

    Failure to maintain building in a code compliant manner: atoi the ceiling & wall finishes at stairwell (b) were observed in a state of disrepair with vertical & horizontal cracks, peeling paint and broken piece

    Jul 24, 2025 · Penalty $6,250

    Resolve
  • Class - 2

    A8: unapproved/unsafe/unsuitable electrical equipment, apparatus, materials, devices, appliances or wiring in use. i observed in apt 308 armored cable attached to sprinkler pipe with electrical tape. in service

    Jul 21, 2025 · Penalty $400

    Resolve
  • Class - 2

    1) phone/video and text communications not working. 2) remove piping from hoistway (this hoistway was expanded in size; therefore it fall under the building code at the time of construction/alteration)

    Jun 9, 2025

    Resolve
  • Class - 3

    Failure to provide heating system/boiler room access information sign as per hmc 27-2033..; 28-301.1, comply with code; correct any violating conditions. comply with hmc 27-2033 and submit a certificate of co

    Feb 10, 2025

    Resolve
  • Class - 1

    Failure to comply with tenant protection plan. atoi observed tpp states tack mats shall be provided in front of all units where active construction is taking place as well as zipper duct barrier at entrance to

    Jan 28, 2025 · Penalty $2,500

    Resolve
  • Class - 1

    Ftc with tpp. atoi observed excessive amounts of dust in hallway at 1st and 4th floors. tpp states debris shall be kept within unit where construction is taking place. also, no zipper duct barriers at entrance

    Nov 14, 2024 · Penalty $2,500

    Resolve

Complaints

  • General

    Signage missing

    Oct 17, 2017 · Apt 206

    Close
  • General

    Signage missing

    Oct 17, 2017 · Apt 206

    Close
  • Water leak

    Damp spot

    Oct 17, 2017 · Apt 206

    Close
  • Heat/hot water

    Apartment only

    Oct 17, 2017 · Apt 206

    Close
  • Heat/hot water

    Entire building

    Oct 17, 2017 · Apt 206

    Close
  • General

    Cooking gas

    Oct 17, 2017 · Apt 206

    Close
  • General

    Cooking gas

    Oct 17, 2017 · Apt 206

    Close
  • Unsanitary condition

    Garbage/recycling storage

    Oct 19, 2016 · Apt 206

    Close
  • General

    Janitor/super

    Oct 19, 2016 · Apt 206

    Close
  • Safety

    Sprinkler

    Oct 19, 2016 · Apt 206

    Close
Show 40 more ↓
  • General

    Bell/buzzer/intercom

    Jun 18, 2015 · Apt 309

    Close
  • Flooring/stairs

    Floor

    Jun 18, 2015 · Apt 309

    Close
  • Water leak

    Slow leak

    May 4, 2015 · Apt 309

    Close
  • Heat/hot water

    Apartment only

    May 4, 2015 · Apt 309

    Close
  • Heat/hot water

    Apartment only

    Dec 11, 2014 · Apt 309

    Close
  • Heat/hot water

    Apartment only

    Nov 29, 2014 · Apt 301

    Close
  • Water leak

    Slow leak

    Nov 19, 2014 · Apt 408

    Close
  • Water leak

    Damp spot

    Nov 19, 2014 · Apt 408

    Close
  • Heat/hot water

    Apartment only

    Nov 19, 2014 · Apt 408

    Close
  • Flooring/stairs

    Floor

    Nov 9, 2014 · Apt 403

    Close
  • Paint/plaster

    Wall

    Nov 9, 2014 · Apt 403

    Close
  • Unsanitary condition

    Garbage/recycling storage

    Nov 9, 2014 · Apt 403

    Close
  • Flooring/stairs

    Stairs

    Nov 9, 2014 · Apt 403

    Close
  • Door/window

    Door

    Jun 19, 2014 · Apt 308

    Close
  • Plumbing

    Water-leaks

    Jan 29, 2014 · Apt 409

    Close
  • Plumbing

    Water-leaks

    Jan 29, 2014 · Apt 409

    Close
  • Plumbing

    Water-leaks

    Jan 29, 2014 · Apt 409

    Close
  • Heating

    Heat related

    Jan 6, 2014 · Apt 201

    Close
  • Heating

    Heat related

    Dec 5, 2010 · Apt 301

    Close
  • Construction

    Roof

    Nov 4, 2010 · Apt BLDG

    Close
  • Plumbing

    Water supply

    Dec 1, 2008 · Apt 402

    Close
  • Electric

    Wiring

    Apr 26, 2005 · Apt 202

    Close
  • Plumbing

    Water-leaks

    Apr 26, 2005 · Apt 202

    Close
  • Heating

    Heat related

    Jan 26, 2004 · Apt 407

    Close
  • Heating

    Heat related

    Jan 15, 2004 · Apt 407

    Close
  • Heating

    Heat related

    Jan 11, 2004 · Apt 407

    Close
  • Heating

    Heat related

    Jan 8, 2004 · Apt 407

    Close
  • Heating

    Heat related

    Jan 6, 2004 · Apt 407

    Close
  • Heating

    Heat related

    Dec 18, 2003 · Apt 407

    Close
  • Heating

    Heat related

    Nov 9, 2003 · Apt 407

    Close
  • Heating

    Heat related

    Nov 7, 2003 · Apt 407

    Close
  • Heating

    Heat related

    Nov 4, 2003 · Apt 407

    Close
  • Nonconst

    Janitor/super

    Oct 30, 2003 · Apt 407

    Close
  • Heating

    Heat related

    Oct 30, 2003 · Apt 407

    Close
  • Nonconst

    Janitor/super

    Oct 28, 2003 · Apt 407

    Close
  • Heating

    Heat related

    Oct 28, 2003 · Apt 407

    Close
  • Nonconst

    Janitor/super

    Oct 27, 2003 · Apt 407

    Close
  • Heating

    Heat related

    Oct 27, 2003 · Apt 407

    Close
  • Heating

    Heat related

    Oct 24, 2003 · Apt 407

    Close
  • Heating

    Heat related

    Oct 23, 2003 · Apt 407

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D5)
Year built
1905
Floors
4
Residential units
36
Building area
40,000 ft²
Lot area
10,017 ft²
Zoning
R6B
Community board
307
Council district
39
Block / lot
873 / 69
Assessed value
$3,150,000
Landmark / historic district
No

HPD registration #384865, last renewed Aug 23, 2025.

Questions about 255 18 Street

Who owns 255 18 Street?

The owner of record in NYC Department of City Planning PLUTO data is Eighteen Properties LLC.

Does 255 18 Street have violations?

Yes. NYC HPD has recorded 48 housing violations at this property.

Is 255 18 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 255 18 Street built?

City records list 1905 as the year it was built.

How many apartments are in 255 18 Street?

It has 36 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.