Violations at 5821 5 Avenue

Brooklyn, NY 11220 · BBL 3-00856-0002 · Back to the property

HPD housing violations

42 HPD violations, newest first.

  • ANon-hazardous

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 30, 2026

    Closed — Violation dismissed
  • BHazardous

    Remove all encumbrances consisting of household items at public hall, 3rd story

    Jun 12, 2023

    Open — Nov sent out
  • BHazardous

    Remove all encumbrances consisting of household items at public hall, 4th story

    Jun 12, 2023

    Open — Nov sent out
  • ANon-hazardous

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Mar 20, 2023

    Closed — Violation dismissed
  • BHazardous

    Remove all encumbrances consisting of house hold items all stories at public hall

    Nov 1, 2022

    Closed — Violation dismissed
  • ANon-hazardous

    § 300 m/d law file plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration suspending ceiling in the 5th room from east located at apt 4l, 4th story, 1st apartment from west at north

    Nov 1, 2022 · Apt 4L

    Open — Not complied with
  • BHazardous

    Properly repair the broken or defective counter balance lower sash window at west wall in the 5th room from east located at apt 4l, 4th story, 1st apartment from west at north

    Nov 1, 2022 · Apt 4L

    Closed — Violation closed
  • BHazardous

    Properly repair the broken or defective counter balance lower sash window at east wall in the 4th room from east located at apt 4l, 4th story, 1st apartment from west at north

    Nov 1, 2022 · Apt 4L

    Closed — Violation closed
  • BHazardous

    Provide a safe and adequate supply of electric service to the fixtures at ceiling in the 4th room from east located at apt 4l, 4th story, 1st apartment from west at north

    Nov 1, 2022 · Apt 4L

    Closed — Violation closed
  • BHazardous

    Properly repair and abate unsafe electric wiring condition consisting of exposed wires at north wall in the 3rd room from east located at apt 4l, 4th story, 1st apartment from west at north

    Nov 1, 2022 · Apt 4L

    Closed — Violation closed
  • BHazardous

    Replace with new the missing outlet cover at north wall in the 3rd room from east located at apt 4l, 4th story, 1st apartment from west at north

    Nov 1, 2022 · Apt 4L

    Closed — Violation closed
  • CImmediately hazardous

    Abate the infestation consisting of mice in the entire apartment located at apt 4l, 4th story, 1st apartment from west at north

    Nov 1, 2022 · Apt 4L

    Open — Not complied with
  • CImmediately hazardous

    Abate the infestation consisting of roaches in the entire apartment located at apt 4l, 4th story, 1st apartment from west at north

    Nov 1, 2022 · Apt 4L

    Open — Not complied with
  • BHazardous

    Repair or replace the carbon monoxide detecting device(s). missing in the entire apartment located at apt 4l, 4th story, 1st apartment from west at north

    Nov 1, 2022 · Apt 4L

    Closed — Violation closed
  • BHazardous

    Repair or replace the smoke detector missing in the entire apartment located at apt 4l, 4th story, 1st apartment from west at north

    Nov 1, 2022 · Apt 4L

    Closed — Violation closed
  • BHazardous

    Provide adequate supply of hot water for the fixtures at wash basin in the bathroom located at apt 4l, 4th story, 1st apartment from west at north

    Nov 1, 2022 · Apt 4L

    Closed — Violation closed
  • BHazardous

    Provide adequate supply of cold water for the fixtures at wash basin in the bathroom located at apt 4l, 4th story, 1st apartment from west at north

    Nov 1, 2022 · Apt 4L

    Closed — Violation closed
  • BHazardous

    Properly repair the broken or defective intercom system from building entrance to the box on south wall in the 2nd room from east located at apt 4l, 4th story, 1st apartment from west at north

    Nov 1, 2022 · Apt 4L

    Closed — Violation closed
  • BHazardous

    Properly repair the broken or defective counter balance lower sash window at east wall in the kitchen located at apt 4l, 4th story, 1st apartment from west at north

    Nov 1, 2022 · Apt 4L

    Closed — Violation closed
  • BHazardous

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the kitchen located at apt 4l, 4th story, 1st apartment from west at north

    Nov 1, 2022 · Apt 4L

    Open — Not complied with
  • ANon-hazardous

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Feb 18, 2022

    Closed — Violation dismissed
  • IInformation / order

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 28, 2019

    Closed — Violation dismissed
  • IInformation / order

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 12, 2018

    Closed — Violation dismissed
  • ANon-hazardous

    Post, in a form approved by the commissioner, and maintain a notice in a common area of the building regarding the procedures that should be followed when a gas leak is suspected

    Sep 6, 2017

    Closed — Violation closed
  • ANon-hazardous

    Post a proper notice of carbon monoxide detecting device requirements, in a form approved by the commissioner, in a common area of a class a multiple dwelling near inspection certificate or provide notice to tenants in a private dwelling. at public hall, 1st story

    Sep 6, 2017

    Closed — Violation closed
  • ANon-hazardous

    Post a proper notice of smoke detector requirements, in a form approved by the commissioner, at or near the mail box .. at public hall, 1st story

    Sep 6, 2017

    Closed — Violation closed
  • ANon-hazardous

    Post and maintain a proper notice on wall of the entrance story in english and spanish on the availability of the agencys housing information guide. a sample notice can be found at www.nyc.gov/hpd., 1st story

    Sep 6, 2017

    Closed — Violation closed
  • ANon-hazardous

    § 329, m/d law and dept. rules and regs. provide a completed certificate of inspection visits in a proper frame at or near mailboxes, bottom edge of frame between 48-62 inches above floor frame missing at public hall, 1st story

    Sep 6, 2017

    Closed — Violation closed
  • BHazardous

    M/d law abate the nuisance consisting of intercom at vestibule behind locked door at entrance to building , 1st story

    Sep 6, 2017

    Closed — Violation closed
  • CImmediately hazardous

    Remove the illegal double cylinder key operated locking device at door of building entrance , 1st story

    Aug 18, 2017

    Closed — Violation closed
  • IInformation / order

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 1, 2016

    Closed — Violation dismissed
  • IInformation / order

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 6, 2015

    Closed — Violation dismissed
  • BHazardous

    Provide adequate lighting at or near the outside of the front entranceway of the building and keep same burning from sunset every day to sunrise on the day following a minimum of 100 watts of incandescent light required. (light fixture present)

    Aug 31, 2015

    Closed — Violation closed
  • IInformation / order

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Feb 5, 2015

    Closed — Violation dismissed
  • BHazardous

    Repair or replace the smoke detector defective located at apt 2r, 2nd story

    Nov 9, 2012 · Apt 2R

    Closed — Violation closed
  • BHazardous

    Provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules. located at apt 2r, 2nd story

    Nov 9, 2012 · Apt 2R

    Closed — Violation closed
  • BHazardous

    Remove the accumulation of refuse and/or rubbish and maintain in a clean condition the ,. at public hall, 1st story

    Jun 1, 2010

    Closed — Violation closed
  • ANon-hazardous

    Provide place within the building for the storage of waste receptacles and disinfect same regularly. at public hall, 1st story

    Jun 1, 2010

    Closed — Violation closed
  • CImmediately hazardous

    Properly repair the broken or defective lock at entrance door to building from street at public hall, 1st story

    Sep 23, 2009

    Closed — Violation closed
  • BHazardous

    Provide adequate lighting at or near the outside of the front entranceway of the building and keep same burning from sunset every day to sunrise on the day following 200 watts required fixture present light not on

    Sep 23, 2002

    Closed — Violation closed
  • BHazardous

    Repair the broken or defective plastered surfaces and paint in a uniform color walls and ceilings thru out 2 sty apt 2l. , section '' ''

    Jan 12, 1998 · Apt 2L

    Closed — Violation closed
  • BHazardous

    Fire egress defective. remove obstructing bars or unlawful gates from window to fire escape or provide approved type gate 3 sty apt 3l. , section '' ''

    Jan 12, 1998 · Apt 3L

    Closed — Violation closed

DOB building violations

14 DOB violations, newest first.

  • Low pressure boiler boiler required

    Violation issued-failure to file 2019 external low pressure inspection

    Jun 20, 2023

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued-failure to file 2018 external low pressure inspection

    Jun 20, 2023

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2017 inspection report

    Nov 8, 2019

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2016 inspection report

    Apr 6, 2018

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2015 inspection report

    Feb 24, 2017

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2012 inspection report

    May 15, 2014

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2012 inspection report

    May 15, 2014

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2011 inspection report

    Mar 1, 2013

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jul 25, 1994

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jul 25, 1994

    Dob violation - dismissed
  • Boiler boiler optional

    3/24a/24b/42c flue pipe not connected properly-return line corroded and leaking-steam gauge not working

    Dec 27, 1989

    Dob violation - dismissed
  • Boiler boiler optional

    3/3a/7b/7c/31a flue pipe not connected properly/one section of flue pipe rotted-smoke pipe rotted and collasped-exposed wiring

    Dec 27, 1989

    Dob violation - dismissed

ECB violations

4 ECB violations, newest first.

  • Class - 2

    Work without permit; noted at time of inspection observe erected wooden w/ corrugate metal and poles top for canopy structure on both side of store rear yard, where as store #5821 attached to the rear wall and

    Jul 10, 2024

    Resolve
  • Non-hazardous

    Exit passage required width decreased by obstruction.noted:at rear yard fire escape ladder and balconies blocked by branches of large tree.remedy:remove obstruction and maintain egress as per code.

    Jul 26, 2005

    Resolve
  • Unknown

    Flue pipe not connected properly, one section of flue pipe rotted smoke pipe rotted and collapsed, exposed wiring.

    Dec 27, 1989 · Penalty $150

    Resolve
  • Unknown

    Flue pipe not connected properly return line corroded & leaiking steam guage not working.

    Dec 27, 1989 · Penalty $150

    Resolve