Violations at 4705 5 Avenue

Brooklyn, NY 11220 · BBL 3-00766-0006 · Back to the property

HPD housing violations

No HPD violations on record

DOB building violations

1 DOB violations, newest first.

  • Low pressure boiler boiler required

    Violation issued-failure to file 2018 external low pressure inspection

    Jun 20, 2023

    Dob violation - dismissed

ECB violations

11 ECB violations, newest first.

  • Class - 2

    Job 321388832 issued 07-09-19 alteration-1 to change use as supermarket also to amend c/o. as of this inspection c/o 60996 details building as motion pictures 07-10-30, building altered under job alt-1 no chang

    Jul 27, 2020 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to have or maintain the required daily log book(log book inadequate) at the time of my inspection on an active job site of a 1 sty bldg. i observed workers on site engaged in plumbing activities on the

    Jun 26, 2019

    Resolve
  • Class - 2

    Failure to provide approved/accepted construction documents at job site at the time of inspection(no site safety plans). at the time of my inspection on an active jobsite of a 1 sty bldg. i observed on site of

    Jun 26, 2019

    Resolve
  • Class - 1

    Failure to designate &/or have a construction superintendent &/or competent person on site as required by code. at the time of my inspectionon an active jobsite of a 1 sty bldg. i observed workers working on th

    Jun 26, 2019

    Resolve
  • Class - 1

    Failure to file evidence of compliance w/workers comp/law &/or diability benefits law(expired disabilty/workers comp). at the time of my inspection on an active jobsite of a 1 sty bldg. i observed workers on th

    Jun 26, 2019

    Resolve
  • Class - 1

    Failure to notify the dept prior to commencement of earthwork(no rule 52)at time of inspection: i observed excavation wokr done in cellar,approx 8'x8'x5'deep. also a strip 36"x12"x12ft deep. no notification was

    Apr 30, 2018

    Resolve
  • Class - 2

    Failure to provide approved construction documents &/or approved amendments)no see or underpinning dwg)at the time of inspection i observed excavation work underpinning address incellar no soe or underpinning

    Apr 30, 2018

    Resolve
  • Class - 1

    Failure to institute/maintain safety equipment measures or temporary construction(no rebar caps)at time of inspection excavatopm & rebars were done in cellar. there are rebars protruding upwards at exp#2 w/no

    Apr 30, 2018 · Penalty $625

    Resolve
  • Class - 1

    Sec. 3303.9 failure to provide required means of egress & other elements in existing bldg under construction. at time of inspection i observed work presently being done in cellar(excavation)2 metal bars blocked

    Apr 30, 2018

    Resolve
  • Class - 2

    Sec. 3309.6 failure to monitor adjoining structures for movement in all directions during excavation related activity that may adversely affect adjoining structures. at the time of inspection it was observed ex

    May 12, 2016

    Resolve
  • Class - 1

    Failure to notify dob w/i 24-48hrs of the start of excavation. at the time of inspection,it was observed excavation was on going & there wasno notifucation was ongoing & there was no notification # from the dob

    May 12, 2016 · Penalty $1,230

    Resolve