201 46 Street
Brooklyn, NY 11232BBL 3-00745-0001Map
Owner of record: Shunhe Management LLC
201 46 Street is a warehouse built in 1900 in Brooklyn, 11232. The owner of record is Shunhe Management LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 32
- ECB violations
- 19
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 32
- Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2022)
Apr 22, 2023
Dob violation - dismissed - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2021)
Aug 21, 2022
Dob violation - dismissed - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2020)
Jun 20, 2021
Dob violation - dismissed - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2019)
Jun 19, 2021
Dob violation - dismissed - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2018)
Jun 18, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 6, 2019
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 4, 2018
Dob violation - active - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2017)
Mar 27, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 18, 2017
Dob violation - resolved
Show 22 more ↓
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Apr 5, 2017
Dob violation - dismissed - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2016)
Feb 16, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - active - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - active - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 in 2015
Mar 14, 2016
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 17, 2015
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2013 inspection/test
Oct 31, 2014
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 17, 2014
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2012 inspection/test
Mar 31, 2014
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 30, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 4, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 19, 2009
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 24, 2008
Dob violation - resolved - Construction other optional
C-construction other optional
Jul 30, 2007
Vw*-violation - work w/o permit dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
May 11, 2007
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 1, 2006
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 6, 2005
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 3, 2004
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 22, 2003
Dob violation - resolved - Elevator elevatorrequired
3f1898
Feb 28, 2001
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed
ECB violations · 19
- Class - 2
Work without permit. noted: illuminated sign reads: " family hall center" sign is approx: 20'x 3' was installed without a permit., obtain all permits
Oct 29, 2025
Resolve - Class - 2
Failure to comply with commissioner's order contained in summons #35588261x issued on 04/28/2022, and failure to file a certificate of correction pursuant to 28.201.1 and 1 rcny 102-01(d)(2). an acceptable cert
Jan 8, 2025 · Penalty $1,280
Active - Class - 2
Altered/changed building occupied without a valid certificate of occupancy as per 28-118.3.1 - 28-118.3.2. at the time of inspection observed only three certificate of occupancy contrary to c of o, there was a
Jul 21, 2022 · Penalty $6,250
Active - Class - 2
Altered/changed building occupied without a valid certificate of occupancy as per 28-118.3.1;28-118.3.2 at the time of inspection observed aonly 3 cert of occupancy contrary to cofo observed at a restaurant,bar
Apr 28, 2022 · Penalty $1,250
Active - Class - 2
Seal hoist machine leaks. inoperative car phone. remove non elevator equipment from machine room. provide parking device at top landing. unreadable controller fuses. expired brake maint tag. maint log not up to
Sep 30, 2021 · Penalty $625
Active - Class - 1
Major elevator corp, license 220-001, maintenance and repair is not in accordance with code. failure to maintain device in accordance with asme a17.1 8.6.1 and 8.6.4violating condition;jumper installed on hois
Dec 21, 2018
Resolve - Class - 1
3001.2 21r09, major elevator corp license no 220-001 maintenance and repair is not in accordance with code failure to maintain device in accordance with asme a17.18.6 and 8.6.4. violating condition.
Dec 21, 2018
Resolve - Class - 1
Cease use items: 1)hoistway door lock by passed by jumper on controller 2) hoistway doors misaligned. eliminate gaps when lock is made mechanically. 3) gate switches misaligned, can be opened halfway before swi
Dec 21, 2018 · Penalty $1,250
Resolve - Class - 2
100m07,16r09,16j01,16t07,52q03,59b11,61r11,61g11,56y13,68m07,11m07,16h11,05h11,41b07,20i11,70o02,52b07,03i10. 100m-in case of fire signage 16r-illegal vestibule (gate) at loading dock; 16t-floor numbers were
Jan 23, 2018 · Penalty $500
Resolve - Class - 1
52bb12,52bb15,52bb17,54bb12,54bb15,54bb17,55bb12,55bb15,55bb17 all cu.cease use 52bb-reshackle hoist ropes and provide tag with date; 54bb-reshackle counterweight ropes and provide tag with date; 55bb-reshackle
Jan 4, 2017 · Penalty $1,000
Resolve
Show 9 more ↓
- Class - 2
Failure to maintain bldg. noted: next to 2nd entrance door, section ofcmu wall approx 2' x 9' w/vertical & step cracks. approx (1/2" x 9'). remedy: repair defects & maintain bldg forthwith.
Jun 11, 2012
Resolve - Non-hazardous
18a,18b
Dec 1, 2006
Resolve - Non-hazardous
50a/50b 50c fulton v.t. boiler, 15hp, nb68086, gas, 1993 50a) no structural support on the flue pipe system. install a heavy duty hanger to the boiler room ceiling. 50b) corrosion and leakage on the feed water
Oct 5, 2004 · Penalty $2,500
Active - Non-hazardous
B4a/24b/40/50a/50b 50a-saftey valve not piped down 50b-anti syphon valve missing from oil supply line.
Jul 30, 2003 · Penalty $180
Active - Non-hazardous
73u16/46u13/48u13/32q3/46o2/48o2/14m7/15o2/3o2/57o2/22d6. 73- city id tags.
Jan 14, 2002
Resolve - Non-hazardous
16/ 18a/ 18b/ 36/ 48b/ 49/ 44c/ 49) bq9 27-147 fulton high pressure boiler fb 015a nb # 680 86 built installed without a permit from dob. 27-127 boiler operating w/o an equipment sue permit form dob. sub
Jan 7, 2002 · Penalty $180
Resolve - Non-hazardous
75u 15l 57o 75 perform 5year test 15 repair hoistway 4 and 5th floor door 57 clean down shaftway top of car and pit
Dec 7, 1998 · Penalty $350
Resolve - Non-hazardous
46#,49#,57o,62q,18q,58o,59o,03o, 62. elec. cover missing. 18.missing door lock cover street side main fl. 03. top of elev.
Nov 13, 1992 · Penalty $1,000
Resolve - Non-hazardous
73#, 73. perform 5yr test, properly tag device and file form elv. 3.
Mar 13, 1992 · Penalty $75
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Warehouse (E9)
- Year built
- 1900
- Floors
- 5
- Residential units
- —
- Building area
- 52,000 ft²
- Lot area
- 26,033 ft²
- Zoning
- M1-2D
- Community board
- 307
- Council district
- 38
- Block / lot
- 745 / 1
- Assessed value
- $3,149,550
- Landmark / historic district
- No
Questions about 201 46 Street
Who owns 201 46 Street?
The owner of record in NYC Department of City Planning PLUTO data is Shunhe Management LLC.
Does 201 46 Street have violations?
NYC HPD has no housing violations on record for this property.
Is 201 46 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 201 46 Street built?
City records list 1900 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.