4 Strong Place
Brooklyn, NY 11231BBL 3-00323-0038Map
Owner of record: Mccann, Lindsay S
4 Strong Place is an one-family home built in 2015 in Brooklyn, 11231. It has 1 residential unit across 4 floors. The owner of record is Mccann, Lindsay S. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 1
- ECB violations
- 14
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 1
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Feb 26, 2014
Dob violation - dismissed
ECB violations · 14
- Class - 1
3314.13.1 numerous cross braces are missing for supported scaffolding @ exp 3(rear of bldg),demolition exsists for both the scaffolds @ grade lvl & scaffold @ 2nd fl set both.partial stop work order.issued purs
Jul 16, 2014 · Penalty $1,600
Resolve - Class - 1
3314.13.1 numerous cross braces are missing for supported scaffolding @ exp 3(rear of bldg).condition exsists for both scaffolds @ grade lvl& @ 2nd fl set both.partial stop work order:issued pursuant to 28-207.
Jul 16, 2014 · Penalty $1,600
Resolve - Class - 1
3314.13.1 numerous cross braces are missing for suppoted scaffolding @exp 3(rear of bldg).condition exist for both scaffolds @ grade lvl & @2nd fl set both.partial stop work order.issued pursuant to 28-207.2 &
Jul 16, 2014 · Penalty $1,600
Resolve - Class - 1
Sec. 3314.5.5. planks on supported scaffolding have not been tied down, cleated or otherwise restrained by hooks or equivalent means to prevent dilodgement. partial swo- issued pursuant to 28-207.2 and posted @
Nov 25, 2013 · Penalty $400
Resolve - Class - 1
3301.7 design required by chapter 33. noted: at time of inspection no design drawing found for apprx 32'high supporting scaffold that partially standing on existing sidewalk shed at exp 2.no design drawing prov
Nov 25, 2013 · Penalty $1,600
Resolve - Class - 1
Failure to safeguard all persons and property during construction operations. netting attached to scaffolding has completely public away from exp 1 leaving an opening/gap between wall & adj bldg and scaffolding
Nov 25, 2013 · Penalty $2,430
Resolve - Class - 1
Sec. 3307.7. gate section fence (entrance to site) on kane st is not 8' high or made out of solid material. gate is more of a chain link fence 6' high w/tarp attached to the inner side. remedy: conform to code
Nov 25, 2013 · Penalty $1,600
Resolve - Class - 2
Failed to obtain a temporary construction permit prior to use/installation of sidewalk shed. at the time of inspection no valid permit foundfor the existing sidewalk shed at exp 1. remedy: obtain permit for 4
Nov 25, 2013
Resolve - Class - 1
Failure to institute/maintain safety equipment measures or temporary construction - no guard rails. noted: at time of inspection of a nb under construction there are guard rails missing surrounding 10' deep
Aug 5, 2013 · Penalty $2,400
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments. noted: 5 sty bldg w/job #320565198 for (soe) plan amendments. @ time of inspection nb under construction @ partial foundation
Aug 5, 2013
Resolve
Show 4 more ↓
- Class - 1
Failure to institute/maintain safety equipment measures or temp construction - no guard rails. noted: at time of inspection at a nb under construction.there areguard rails missing surrounding10'deepfoundation
Aug 5, 2013 · Penalty $2,400
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments. noted: at nb at partial foundation stage has approx 6' of timber lagging missing for support of excavation leaving public
Aug 5, 2013
Resolve - Class - 1
Failure to institute/maintain safety equipment measures or temp construction - no guard rails. noted: at time of inspection of a nb under construction there are guardrails missing surrounding10'deepfoundation
Aug 5, 2013 · Penalty $2,400
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments. at the time of inspection nb at partial foundation stage has missing approx 6' timber lagging for supported excavationleaving
Aug 5, 2013
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- One-family home (A5)
- Year built
- 2015
- Floors
- 4
- Residential units
- 1
- Building area
- 3,956 ft²
- Lot area
- 2,128 ft²
- Zoning
- R6
- Community board
- 306
- Council district
- 39
- Block / lot
- 323 / 38
- Assessed value
- $374,580
- Landmark / historic district
- Cobble Hill Historic District
Questions about 4 Strong Place
Who owns 4 Strong Place?
The owner of record in NYC Department of City Planning PLUTO data is Mccann, Lindsay S.
Does 4 Strong Place have violations?
NYC HPD has no housing violations on record for this property.
Is 4 Strong Place rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 4 Strong Place built?
City records list 2015 as the year it was built.
How many apartments are in 4 Strong Place?
It has 1 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.