Violations at East 229th Street
Bronx, NY 10466 · BBL 2-04905-0001 · Back to the property
HPD housing violations
The newest 50 of 737 HPD violations. The city keeps the complete history.
- CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective hinges at fire door at public hall, 1st story
Oct 28, 2026
Open — Violation open - ANon-hazardous
§ 329, m/d law and dept. rules and regs. provide a completed certificate of inspection visits in a proper frame at or near mailboxes, bottom edge of frame between 48-62 inches above floor missing at public hall, 1st story
Oct 28, 2026
Open — Violation open - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective hinges at hopper door at east wall at public hall, 1st story
Oct 21, 2026
Open — Violation will be reinspected - ANon-hazardous
Post sign on wall of entrance story bearing name, address including apartment number if any, and telephone number of superintendent, janitor or housekeeper. at public hall, 1st story
Oct 20, 2026
Open — Nov sent out - ANon-hazardous
Post a proper notice of carbon monoxide detecting device requirements, in a form approved by commissioner, in a common area of a class a multiple dwelling near inspection certificate or provide notice to tenants in private dwellings missing
Oct 20, 2026
Open — Nov sent out - ANon-hazardous
Post, in a form approved by the commissioner, and maintain a notice in a common area of the building regarding the procedures that should be followed when a gas leak is suspected at public hall, 1st story
Oct 20, 2026
Open — Nov sent out - ANon-hazardous
Post and maintain a proper sign on wall of entrance story showing the registration number assigned by the department and the address of the building. at public hall, 1st story
Oct 20, 2026
Open — Nov sent out - ANon-hazardous
Post a proper notice of smoke detector requirements, in a form approved by the commissioner, at or near the mailbox missing at public hall, 1st story
Oct 20, 2026
Open — Nov sent out - CImmediately hazardous
Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system missing at public hall, 1st story
Oct 20, 2026
Open — Nov certified on time - ANon-hazardous
Post and maintain a proper notice on wall of the entrance story in english and spanish on the availability of the agencys housing information guide. a sample notice can be found at www.nyc.gov/hpd. at public hall, 1st story
Oct 20, 2026
Open — Nov sent out - ANon-hazardous
§ 329, m/d law and dept. rules and regs. provide a completed certificate of inspection visits in a proper frame at or near mailboxes, bottom edge of frame between 48-62 inches above floor missing at public hall, 1st story
Oct 20, 2026
Open — Nov sent out - BHazardous
Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the bathroom located at apt 8g, 8th story, 1st apartment from north at east
Oct 20, 2026 · Apt 8G
Open — Nov sent out - BHazardous
Properly repair the source and abate the evidence of a water leak ay ceiling in the bathroom located at apt 8g, 8th story, 1st apartment from north at east
Oct 20, 2026 · Apt 8G
Open — Nov sent out - BHazardous
Provide adequate supply of hot water for the fixtures ..no volume in the entire apartment located at apt 8g, 8th story, 1st apartment from north at east
Oct 20, 2026 · Apt 8G
Open — Nov sent out - CImmediately hazardous
Abate the infestation consisting of roaches in the entire apartment located at apt 8g, 8th story, 1st apartment from north at east
Oct 20, 2026 · Apt 8G
Open — Notice of issuance sent to tenant - BHazardous
Properly repair with similar material the broken or defective wooden floor tiles lifting in the private hallway located at apt 9c, 9th story, 1st apartment from north at east
Oct 7, 2026 · Apt 9C
Open — Nov sent out - BHazardous
Properly repair with similar material the broken or defective wooden floor tiles lifting in the private hallway located at apt 9c, 9th story, 1st apartment from north at east
Oct 7, 2026 · Apt 9C
Open — Nov sent out - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective missing door at boiler room
Sep 21, 2026
Open — Nov sent out - BHazardous
Repair, replace or provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations missing located at apt 1c, 1st apartment from west at north
Sep 14, 2026 · Apt 1C
Open — Civ14 mailed - BHazardous
Repair, replace or provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules missing located at apt 1c, 1st apartment from west at north
Sep 14, 2026 · Apt 1C
Open — Civ14 mailed - BHazardous
Properly repair or replace the broken or defective the wood door at entrance in the bathroom located at apt 1a, 1st story, 1st apartment from east at south , section ''1166''
Aug 5, 2026 · Apt 1A
Open — First no access to re- inspect violation - ANon-hazardous
Paint with light colored paint to the satisfaction of this department all walls in the bathroom located at apt 1a, 1st story, 1st apartment from east at south , section ''1166''
Aug 5, 2026 · Apt 1A
Open — First no access to re- inspect violation - BHazardous
Repair the broken or defective plastered surfaces and paint in a uniform color the west, south and east walls in the 1st room from east at south located at apt 1a, 1st story, 1st apartment from east at south , section ''1166''
Aug 5, 2026 · Apt 1A
Open — First no access to re- inspect violation - BHazardous
Repair the broken or defective plastered surfaces and paint in a uniform color the west wall in the foyer located at apt 1a, 1st story, 1st apartment from east at south , section ''1166''
Aug 5, 2026 · Apt 1A
Open — First no access to re- inspect violation - ANon-hazardous
Paint with light colored paint to the satisfaction of this department the stool to window at west in the kitchen located at apt 1a, 1st story, 1st apartment from east at south , section ''1166''
Aug 5, 2026 · Apt 1A
Open — Civ14 mailed - BHazardous
Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling in the kitchen located at apt 1a, 1st story, 1st apartment from east at south , section ''1166''
Aug 5, 2026 · Apt 1A
Open — First no access to re- inspect violation - BHazardous
Properly repair the source and abate the evidence of a water leak above the ceiling in the kitchen located at apt 1a, 1st story, 1st apartment from east at south , section ''1166''
Aug 5, 2026 · Apt 1A
Open — First no access to re- inspect violation - ANon-hazardous
Paint metal in accordance with dept. regulation pipes at ceiling in the bathroom located at apt 1a, 1st story, 1st apartment from east at south , section ''1166''
Aug 5, 2026 · Apt 1A
Open — First no access to re- inspect violation - BHazardous
Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling and north wall in the bathroom located at apt 1a, 1st story, 1st apartment from east at south , section ''1166''
Aug 5, 2026 · Apt 1A
Open — First no access to re- inspect violation - BHazardous
Properly repair the source and abate the evidence of a water leak above the ceiling in the bathroom located at apt 1a, 1st story, 1st apartment from east at south , section ''1166''
Aug 5, 2026 · Apt 1A
Open — First no access to re- inspect violation - BHazardous
Properly repair or replace the broken or defective lower glass pane at building entrance door at public hall, 1st story
Jul 15, 2026
Closed — Violation closed - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective hinges at building entrance door , 1st story
Jul 14, 2026
Closed — Violation closed - CImmediately hazardous
Abate the infestation consisting of mice in the entire apartment located at apt 1c, 1st story, 1st apartment from south at west
Jul 13, 2026 · Apt 1C
Closed — Violation closed - CImmediately hazardous
Abate the infestation consisting of roaches in the entire apartment located at apt 1c, 1st story, 1st apartment from south at west
Jul 13, 2026 · Apt 1C
Open — Not complied with - BHazardous
Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the kitchen located at apt 1c, 1st story, 1st apartment from south at west
Jul 13, 2026 · Apt 1C
Closed — Violation closed - BHazardous
Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling and east wall in the foyer located at apt 1c, 1st story, 1st apartment from south at west
Jul 13, 2026 · Apt 1C
Closed — Violation closed - BHazardous
Trace and repair the source and abate the visible mold condition... at ceiling in the 3rd room from north located at apt 1c, 1st story, 1st apartment from south at west
Jul 13, 2026 · Apt 1C
Open — Defect letter issued - CImmediately hazardous
Abate the infestation consisting of roaches in the entire apartment located at apt 4b, 4th story, 4th apartment from south at west
Jul 9, 2026 · Apt 4B
Open — Not complied with - CImmediately hazardous
Correct failure to notify occupants and/or to investigate lead-based paint hazards.
Jul 7, 2026 · Apt 14E
Open — Nov sent out - CImmediately hazardous
Correct failure to provide to the department within 45 days of demand all records required to be maintained by owner pursuant to local law 1 of 2004 related to lead-based paint notices, inspections and remediation/abatement activities.
Jul 7, 2026 · Apt 14E
Open — Nov sent out - ANon-hazardous
Paint metal in accordance with dept. regulation the steam riser pipe in the bathroom located at apt 1c, 1st story, 1st apartment from west at north
Jul 3, 2026 · Apt 1C
Closed — Violation closed - BHazardous
Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling and all walls in the bathroom located at apt 1c, 1st story, 1st apartment from west at north
Jul 3, 2026 · Apt 1C
Open — Nov sent out - BHazardous
Trace and repair the source and abate the visible mold condition... at ceiling and all walls in the bathroom located at apt 1c, 1st story, 1st apartment from west at north
Jul 3, 2026 · Apt 1C
Open — Defect letter issued - BHazardous
Properly repair or replace the broken or defective latch and assembly at hopper chute at public hall, 1st story
Jul 2, 2026
Closed — Violation dismissed - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective latch at hopper chute at public hall, 1st story
Jul 2, 2026
Closed — Violation closed - BHazardous
Properly repair or replace the broken or defective electrical outlet at south wall in the kitchen located at apt 10c, 10th story, 1st apartment from south at west
Jul 2, 2026 · Apt 10C
Closed — Violation dismissed - BHazardous
Repair, replace or provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations missing in the entire apartment located at apt 1c, 1st story, 1st apartment from south at west
Jul 2, 2026 · Apt 1C
Closed — Violation closed - BHazardous
Repair, replace or provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules missing in the entire apartment located at apt 1c, 1st story, 1st apartment from south at west
Jul 2, 2026 · Apt 1C
Closed — Violation closed - CImmediately hazardous
Abate the infestation consisting of mice in the entire apartment located at apt 1c, 1st story, 1st apartment from south at west
Jul 2, 2026 · Apt 1C
Closed — Violation closed - CImmediately hazardous
Abate the infestation consisting of roaches in the entire apartment located at apt 1c, 1st story, 1st apartment from south at west
Jul 2, 2026 · Apt 1C
Open — Not complied with
DOB building violations
The newest 50 of 249 DOB violations. The city keeps the complete history.
- Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2023)
Jun 23, 2024
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - active - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2022)
Apr 22, 2023
Dob violation - dismissed - Failure to submit eer none
Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2021)
Aug 21, 2022
Dob violation - dismissed - No report and / or late filing (facade) facade required
Failed to file fisp cycle 9a technical report by 02/21/2022
Feb 22, 2022
Dob violation - active - No report and / or late filing (facade) facade required
Failed to file fisp cycle 9a technical report by 02/21/2022
Feb 22, 2022
Dob violation - active - No report and / or late filing (facade) facade required
Failed to file fisp cycle 9a technical report by 02/21/2022
Feb 22, 2022
Dob violation - active - No report and / or late filing (facade) facade required
Failed to file fisp cycle 9a technical report by 02/21/2022
Feb 22, 2022
Dob violation - active - No report and / or late filing (facade) facade required
Failed to file fisp cycle 9a technical report by 02/21/2022
Feb 22, 2022
Dob violation - active - No report and / or late filing (facade) facade required
Failed to file fisp cycle 9a technical report by 02/21/2022
Feb 22, 2022
Dob violation - active - No report and / or late filing (facade) facade required
Failed to file fisp cycle 9a technical report by 02/21/2022
Feb 22, 2022
Dob violation - active - No report and / or late filing (facade) facade required
Failed to file fisp cycle 9a technical report by 02/21/2022
Feb 22, 2022
Dob violation - active - No report and / or late filing (facade) facade required
Failed to file fisp cycle 9a technical report by 02/21/2022
Feb 22, 2022
Dob violation - active - No report and / or late filing (facade) facade required
Failed to file fisp cycle 9a technical report by 02/21/2022
Feb 22, 2022
Dob violation - active - Nycha elevator periodic inspection/test elevatorrequired
Failure to perform category 5 inspection
Dec 17, 2021
Dob violation - active - Nycha elevator periodic inspection/test elevatorrequired
Failure to perform category 5 inspection
Dec 17, 2021
Dob violation - active - Nycha elevator periodic inspection/test elevatorrequired
Failure to perform category 5 inspection
Dec 17, 2021
Dob violation - active - Nycha elevator periodic inspection/test elevatorrequired
Failure to perform category 5 inspection
Dec 17, 2021
Dob violation - active - Nycha elevator periodic inspection/test elevatorrequired
Failure to perform category 5 inspection
Dec 17, 2021
Dob violation - dismissed - Nycha elevator periodic inspection/test elevatorrequired
Failure to perform category 5 inspection
Dec 17, 2021
Dob violation - dismissed - Nycha elevator periodic inspection/test elevatorrequired
Failure to perform category 5 inspection
Dec 17, 2021
Dob violation - dismissed
ECB violations
The newest 50 of 158 ECB violations. The city keeps the complete history.
- Class - 1
Class1 item: rts failure to maintain building in code compliant manner, service elevator equipment as per code bc3001.2 & 27-987. upon inspection, the device is found to be out of service, creating a hazardous
Aug 28, 2026 · Penalty $1,250
Active - Class - 2
Removal of safety measures without department approval. note: at time of inspection i observed no sidewalk shed in place as per permit number: x00936774-i1-sh. remedy: comply with rule.
Aug 10, 2026 · Penalty $1,250
Active - Class - 2
Failure 2 class rts to maintain building in code compliant manner. upon inspection, the device is found to be out of service. remedy: restore to service and contact the dob elevator division at elevatorir@build
Jul 30, 2026 · Penalty $655
Active - Class - 2
14 story alteration active site.observed exterior window replacement work onsite,further inspection of sidewalk shed/overhead protection in place exp#1,2,3,4 permit#x00926769 installed contrary to plans exp#3,4
Jul 16, 2026
Resolve - Class - 2
14 story alteration closed site.observed sidewalk shed/overhead protection in pace at exp#1,3,4 permit#x00936561.upon further inspection shed vertical member leaning not plumb. missing parapet signage, missing/
Jul 15, 2026
Resolve - Class - 2
Upon inspection, the device is found to be out-of-service as per 1 rcny 11-02, this device provide service in a 14 story building, remedy restore to service immediately and nycdob the device has been returned t
May 19, 2026 · Penalty $625
Active - Class - 2
Responding to a 311 complaint. upon inspection found the device out of service. remedy;repair then contact nycdob,for a re- inspection
Apr 7, 2026 · Penalty $655
Active - Class - 2
Observed work area at exposure 1 not properly secured or cordoned off. area accessible to unauthorized persons, creating a potential hazard to the public and workers if equipment is tampered with. in violation
Feb 21, 2026 · Penalty $2,500
Resolve - Class - 2
Observed suspended scaffold at exposure 1 raised and resting on entrance enclosure roof without verification that the structure is designed to support imposed loads. scaffold not maintained in a safe and secure
Feb 21, 2026 · Penalty $2,500
Resolve - Class - 2
At time of inspection observed roof access obstructed by padlock and slide bolt in stalled roof access door., repair and/or replace
Dec 10, 2024
Resolve - Class - 2
Responding to a 311 elevator complaint, upon inspection on two device in a building class 2 violation was issued for, no access in motor room ,/ dirty car top, / dirty pit, on both device, remedy; clean and pro
Apr 23, 2024
Resolve - Class - 2
I observed in ground floor hallway in front of elevator wires hanging/exposed from light fixture creating a hazard condition, comply with ec; fix all conditions as per nec and nyc amendments
Apr 19, 2024 · Penalty $400
Resolve - Class - 1
In apt 13g, material from work in apt 14g has fallen down along piping onto floor in bedroom and living room., safeguard public and property
Mar 22, 2024 · Penalty $5,000
Resolve - Class - 2
Steam leak comming from steam trap in tank room., maintain boiler; correct violating condition & submit a certificate of correction.
Mar 27, 2023 · Penalty $625
Resolve - Class - 2
Failure to submit an acceptable required cycle 9a report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control#908724.rem:submit acceptable required t
Dec 2, 2022 · Penalty $1,250
Active - Class - 2
Failure to submit acceptable required cycle9a report of critical examination documenting condition of exterior wall&appurtenances required by28-302.4 for control#908720.submit acceptable required technical repo
Dec 2, 2022 · Penalty $1,250
Active - Class - 2
Failure to submit an acceptable required cycle 9a report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control#908722.rem:submit acceptable required t
Dec 2, 2022 · Penalty $1,250
Active - Class - 2
Failure to submit acceptable required cycle9a report of critical examination documenting condition of exterior wall&appurtenances required by28-302.4 for control#908725.submit acceptable required technical repo
Dec 2, 2022 · Penalty $1,250
Active - Class - 2
Failure to submit acceptable required cycle9a report of critical examination documenting condition of exterior wall&appurtenances required by28-302.4 for control#908726.submit acceptable required technical repo
Dec 2, 2022 · Penalty $1,250
Active - Class - 2
Failure to submit an acceptable required cycle 9a report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control#908727.rem:submit acceptable required t
Dec 2, 2022 · Penalty $1,250
Active - Class - 2
Failure to submit an acceptable required cycle 9a report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control#908730.rem:submit acceptable required t
Dec 2, 2022 · Penalty $1,250
Active - Class - 2
Failure to submit an acceptable required cycle 9a report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control#908732.rem:submit acceptable required t
Dec 2, 2022 · Penalty $1,250
Active - Class - 2
Failure to submit an acceptable required cycle 9a report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control#908733.rem:submit acceptable required t
Dec 2, 2022 · Penalty $1,250
Active - Class - 2
Failure to submit an acceptable required cycle 9a report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control#908721.rem:submit acceptable required t
Dec 2, 2022 · Penalty $1,250
Active - Class - 2
B254 ftm found condensation pump under water /pump defective/correct all violating conditions/submit a certificate of correction
Oct 25, 2022 · Penalty $625
Resolve - Class - 1
Failure to take and provide safety measures sidewalk shed fence netting to protect and secure public safety from documented unsafe facade the unsafe notification(fusp 3)recieved 4/21/2021 from pe/ra filed facad
May 6, 2021 · Penalty $10,000
Resolve - Class - 1
Xailure to take required mesures to protect public from documented unsafe facade as noted a fisp 3 unsafe notification was submitted to the department on 2/20/20 on as of 5/5/20 no safety measures are installed
May 5, 2020 · Penalty $10,000
Resolve - Class - 1
Failure to take and provide adequate safety measures such as sidewalk shed's fence ect.where require to protect and secured public safety from documented unsafe facade as per 1rcny ns 103.04.facade technical re
Mar 9, 2020 · Penalty $10,000
Resolve - Class - 2
At the time of inspection observed at exposure 1 crack window pane.exposure 3:loose brick and multiple damaged joints at parapet wall ad crack window pane.exposure 4:broken window pane at 14 floor.roof open joi
Sep 21, 2019 · Penalty $1,250
Resolve - Class - 1
Failure to maintain building exterior walls/facade and appurtenances.at time of inspection exposure 1:observed damaged mortar joints,crack and step crack.exposure 2:broken window pane,damaged mortar joints and
Sep 21, 2019 · Penalty $2,500
Resolve - Class - 2
At time of inspection observed at exposure 1:crack window pane at 3,5 and 7th floor.exposure 2:crack window pane at 9th floor.exposure 4:crack windown pane at 5th floor.roof:damaged carping at m/c room.also at
Sep 21, 2019 · Penalty $1,250
Resolve - Class - 2
At the time of inspection observed at exposure 1 damaged mortar jointsexposured 3:damaged mortar joints.at roof:damaged coping stone.remedy:maintain building exterior walls/facade and appurtenances provide safe
Sep 21, 2019 · Penalty $1,250
Resolve - Class - 2
Failure to submit acceptable 8th round report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control #808725.rem:submit required technical report.
May 18, 2018
Resolve - Class - 2
Failure to submit acceptable 8th round report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control #808726.rem:submit required technical report.
May 18, 2018
Resolve - Class - 2
Failure to submit acceptable 8th round report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control #808720.rem:submit required technical report.
May 18, 2018
Resolve - Class - 2
Failure to submit acceptable 8th round report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control #808724.rem:submit required technical report.
May 18, 2018
Resolve - Class - 2
Failure to submit acceptable 8th round report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control #808729.rem:submit required technical report.
May 18, 2018
Resolve - Class - 2
Failure to submit acceptable 8th round report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control #808733.rem:submit required technical report.
May 18, 2018
Resolve - Class - 2
Failure to submit acceptable 8th round report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control #808730.rem:submit required technical report.
May 18, 2018
Resolve - Class - 2
Failure to submit acceptable 8th round report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control #808721.rem:submit required technical report.
May 18, 2018
Resolve - Class - 2
Failure to submit acceptable 8th round report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control #808732.rem:submit required technical report.
May 18, 2018
Resolve - Class - 2
Failure to submit acceptable 8th round report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control #808727.rem:submit required technical report.
May 18, 2018
Resolve - Class - 2
Failure to submit acceptable 8th round report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control #808723.rem:submit required technical report.
May 18, 2018
Resolve - Class - 2
Failure to submit acceptable 8th round report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control #808722.rem:submit required technical report.
May 18, 2018
Resolve - Class - 2
Failure to maintain exterior walls/facade and appurtenances. west elevation exp:spalling bricks. east elevation exp: eroded mortar joints south elevation exp 4: spalling bricks roof: terra cotta copping stone
Feb 28, 2018
Resolve - Class - 2
Failure to maintain building exterior walls/facades and appurtenances.various elevations and exposures:spalling bricks and eroded mortar joints roof:broken coping,spalling bricks,eroded mortar joints at
Feb 28, 2018
Resolve - Class - 2
Failure to maintain building exterior walls/facades and appurtenances various elevations and exposures:spalling bricks and eroded mortar joints.roof:broken coping. step cracks at bricks,eroded mortar
Feb 28, 2018
Resolve - Class - 2
Failure to maintian building exterior walls/facades and appurtenances.east elevation exposure 3: eroded mortar joints. south elevation exposure 4: eroded mortar joints. remedy: maintain building exterior
Feb 28, 2018
Resolve - Class - 2
Work without a permit.at time of inspection the violating conditions are as follows:at the rear of main building,near garden area.utility shed constructed of 2x4 stud framing and plywood with tar paper roof
Oct 2, 2017
Resolve - Class - 2
Failure to file an acceptable sixth round technical report in compliance w/ code provisions periodic insp of exterior walls and appurtenances as required by article 28.302 and the dob rules and regulations rem:
Apr 15, 2011
Resolve