Violations at 2500 Fish Avenue

Bronx, NY 10469 · BBL 2-04474-0001 · Back to the property

HPD housing violations

No HPD violations on record

DOB building violations

25 DOB violations, newest first.

  • Low pressure boiler boiler required

    Violation issued-failure to file 2024 external low pressure inspection

    Nov 14, 2025

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2024 external low pressure inspection

    Nov 14, 2025

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2024 external low pressure inspection

    Nov 14, 2025

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2024 external low pressure inspection

    Nov 14, 2025

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2017 inspection report

    Nov 8, 2019

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2017 inspection report

    Nov 8, 2019

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 3, 2008

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 13, 2004

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 13, 2004

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 7, 2000

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 7, 2000

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 10, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 9, 1994

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 9, 1994

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 9, 1994

    Dob violation - dismissed

ECB violations

The newest 50 of 70 ECB violations. The city keeps the complete history.

  • Class - 2

    Reissue on ecb#35720700y altered/changed building occupied without a valid certificate of occupancy as per 28-118.3.1 & 28-118.3.2.noted:new4 story addition to school occupied with expired tco#2129029-08 on 08/

    Apr 30, 2026 · Penalty $3,125

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner.noted:storage inelectrical switch gear closet rooms on rooms 423b,323b,223b and 123b at 4th,3rd,2nd and 1st fl with miscellaneous items of janitorial equipm

    Apr 30, 2026 · Penalty $1,250

    Active
  • Class - 2

    Reissue on ecb#35720702h failure to maintain building in code-compliant manner.noted:spalling plaster due to water damage/water leak at stair d at bulkhead level from 3rd floor to roof level observed upon inspe

    Apr 30, 2026 · Penalty $3,125

    Active
  • Class - 2

    Reissue on ecb#35720703j failure to maintain building in code-compliant manner.noted:fire rated classrooms and smoke doors not closing properly due to binding,missing and/or faulty hardware on classrooms 317,31

    Apr 30, 2026 · Penalty $3,125

    Active
  • Class - 2

    Reissue on ecb#35720704l failure to maintain building in code-compliant manner.illumination for exits,exit discharges and public corridors per bc 1006.1;27-381.noted:emergency illuminating exit lights and exit

    Apr 30, 2026 · Penalty $3,125

    Active
  • Class - 2

    Exit door not self-closing properly at the time of inspection at the time of inspection observed and noted at 3rd floor near room no-321 onecorridor exit door not self-closing properly, at 1st floor play area e

    Jun 18, 2025 · Penalty $625

    Active
  • Class - 2

    Reissue #35683995p date of issue: 10-01-2024. failure to maintain buildingin code-compliant manner. illumination for exits, exit discharges and public corridors per bc 1006.1; 27-381. at the time of inspection

    Jun 18, 2025 · Penalty $3,125

    Active
  • Class - 2

    Reissue #3564996r date of issue: 10-01-2024. failure to maintain building in code-compliant manner. at the time of inspection observed and noted at class room doors with defective/missing door closers at old wi

    Jun 18, 2025 · Penalty $3,125

    Active
  • Class - 2

    Reissue #35684997z date of issue: 10-01-2024. failure to maintain building in code-compliant manner. at the time of inspection observed and noted at stair "d" bulkhead has an approx 3ftx8ft section of plaster m

    Jun 18, 2025 · Penalty $3,125

    Active
  • Class - 2

    Reissue #35684998k date of issue: 10-01-2024. failure to maintain building in code-compliant manner. at the time of inspection observed and noted exterior steps at exit #1(mace ave) have missing/deterioration m

    Jun 18, 2025 · Penalty $3,125

    Resolve
  • Class - 2

    Reissue #35684999m date of issue: 10-01-2024. altered/changed buildingoccupied without a valid certificate of occupancy as per 28-118.3.1-28-118.3.2. at the time of inspection observed and noted new 4 story add

    Jun 18, 2025 · Penalty $3,125

    Active
  • Class - 2

    Altered/chaneged building without a valid certificate of occupancy as per 28-118.3.1-28-118.3.2. noted new 4 story addition to the school bystudents, teachers and staff tco #2129029-08 expired on 08/01/2023. no

    Oct 1, 2024 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner. noted exterior steps at exit #1-(mace ave) have missing/deteriorating mortar between joints and displaced/sunken thread stone approx 2". poses tripping haz

    Oct 1, 2024 · Penalty $625

    Resolve
  • Class - 2

    Reissue #35676304r. failure to maintain building in code-compliant manner. noted stair d bulhead has an approx 3ftx8ft section of planter missing on ceiling and crumbling, spalling/cracking plaster on walls due

    Oct 1, 2024 · Penalty $625

    Active
  • Class - 1

    Reissue #35676303p. failure to maintain building in code-compliant manner. noted: classroom doors with defective/missing closers at old wingroom #317, 315, 313, 311, 329, 327, 305, 256a and 262. also fdsc door

    Oct 1, 2024 · Penalty $1,250

    Active
  • Class - 2

    Reissue #35676305z. failure to maintain building in code-compliant manner: illumination for exits, exit discharges and public corridors per 1006.1; 27-381. noted emergency lights not working when tested at 2nd

    Oct 1, 2024 · Penalty $625

    Active
  • Class - 2

    Reissue #35591730r date of issue:08.24.2021 failure to maintain building in code compliant manner illumination for exits, exit discharges and public corridors per bc 1006.1;27-381 at the time of inspection obse

    Jun 30, 2023 · Penalty $1,562

    Active
  • Class - 2

    Reissue #35665117h date of issue:07.21.2023 failure to maintain building in code compliant manner. at the time of inspection noted at bulkhead stair way "d" ceiling leading to the bulkhead damaged due to water

    Jun 30, 2023 · Penalty $1,562

    Active
  • Class - 2

    Reissue #35665118j date of issue:07.21.22 failure to maintain building in code-compliant manner. at the time of inspection observed and noted missing door self closers at old building room no. 317,315,313,309,3

    Jun 30, 2023 · Penalty $1,562

    Active
  • Class - 2

    Failure to maintain building in code-compliant manner.noted:at(old bldg)cellar level masonry wall for elec.volt,elec meter room has horizontal step crack aprox 10 ft long across top section of entry doors.remed

    Jul 21, 2022 · Penalty $625

    Resolve
  • Class - 2

    Re-issued #35591731z-failure to maintain building in code-compliant manner.noted:observed missing self-closer hardware at classroom doors #317 #315 #313 #311 #309 #307 #305 & 2nd floor classroom #262.remedy:rep

    Jul 21, 2022 · Penalty $1,562

    Active
  • Class - 2

    Re-issued #35591732k-failure to maintain building in code compliant manner.noted:(bulkhead)stairway d ceiling bulging/damaged due to water penetrations coming from above aprox 3ft x 3ft section of ceiling in di

    Jul 21, 2022 · Penalty $1,562

    Active
  • Class - 2

    Re-issued #35591733m-failure to maintain building in code-compliant manner:no fire stopping per bc712.3;27-345.noted:(old&new)cellar level electrical meter room has several pipes penetrating through wall & ceil

    Jul 21, 2022 · Penalty $3,125

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner.no fire stoppingper bc 712.3;27-345.noted:at cellar level electrical room missing firestopping around pipes through ceiling slab and wall.rem:provide/mainta

    Aug 24, 2021 · Penalty $1,250

    Resolve
  • Class - 2

    Reissued#35500802k failure to maintain building in code-compliant manner.noted at stair d leading to bulkhead ceiling is disrepair with missing of a section of ceiling plaster approx 3'x3'due to water penetrati

    Aug 24, 2021 · Penalty $1,562

    Active
  • Class - 2

    Reissued#35500804y failure to maintain building in code compliant manner noted:missing door self closers at room 317,315,313,311,309,307,305256a and 262.rem:repair and/or replace.

    Aug 24, 2021 · Penalty $1,562

    Active
  • Class - 2

    Failure to maintain building in code compliant manner.illumination perbc 1006.1;27-381.noted:at cafeteria emergency light#2 at 1st floor above stairway door d emergency light at 1st floor next to exit 1 emergen

    Aug 24, 2021 · Penalty $625

    Active
  • Class - 2

    Failure to maintain building in code compliant manner use of prohibited doro and or hardware per bc 1008.1.8;27-3715 noted observed illegal kickstop installed ta t-1,t-7,t-2,t-2 ,t-6,t-5,t-4 provide legal hardw

    Jun 16, 2020 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner illumination for exits, exit discharge and public corridor per bc 1006.1-27:381 noted observed existing emergency lights by 260 by 262 cafeteria box #3

    Jun 16, 2020 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner noted observed classroom doors at 3rd floor room 317,315 ,313,311,309,307,305,2nd flor room 256a 262 and fire prrof self closing door #1 by exit 1 are not

    Jun 16, 2020 · Penalty $625

    Active
  • Class - 2

    Failure to maintain building in code compliant manner use of prohibted door and or hardware per bc 1008.1.8;27-3715 noted observed illegal kickstops installed at 321,220,221,gym /auditorium 101,first floor

    Jun 16, 2020 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain building in code compliant manner note observed the staircase ceiling in stair d leading to the bulkhead door has water penetrating leading to spalling plaster repair and or replace

    Jun 16, 2020 · Penalty $625

    Active
  • Class - 2

    Failure to maintain building in code compliant manner noted observed at cellar gas meters room confirmed gas leak at three (3) locations on house piping side of gas service utilities company shut the gas off to

    Jun 16, 2020 · Penalty $625

    Resolve
  • Class - 2

    Bc3307.7.7.8 failure to paint construction fence hunter green at timeof inspection of an inactive 4 story school new building. i observed construction fence on exp1, not painted hunter green. maintain constru

    May 22, 2019 · Penalty $1,280

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner: lack of emergeny lighting for exits, exit discharges and public corridors per bc1006.1-27-542. noted: defective emergency lighting observed at temporary bu

    Jul 21, 2017

    Resolve
  • Class - 2

    Failure to maintain building in code-compliant manner: lack of emergency lighting for exits, exit discharges and public corridors per bc 1006.1-27-542. noted: defective emergency lighting observed at 2nd floor

    Jul 21, 2017

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner: lack of emergency lighting for exits: no emergency light work above the door in the transportable per bc 1006.1;27-542. remedy: repair &/or replace lighting.

    Nov 2, 2016

    Resolve
  • Class - 2

    Failure to maintain bldg in code complaint manner: lack of emergency lighting for exits & exit discharges. lighting not working in temp bldg the one above the doors per bc 1006.1;27-542. remedy: repair &/or rep

    Nov 2, 2016

    Resolve
  • Class - 2

    Failure to maintain bldg in code complaint manner: lack of emergency lighting for exits,exit discharges & public corridors. emergency lightsout in the miti use room per bc 1006.1;27-542. remedy: repair &/or rep

    Nov 2, 2016

    Resolve
  • Class - 2

    Re-issue nov#35107301l rusted steel stair stringers,landings,aprons & ramp.@various locns throughout all transportable units entires/exists.(holes,sharp edges trip hazards).rem:repair &/or replace.

    Feb 5, 2015

    Resolve
  • Class - 2

    Re-issue nov#35107302n-trip hazard-concrete paving cracked/heaved/spalling various locns surrounding transportable units.rem:repair &/or replace defect noted.

    Feb 5, 2015

    Resolve
  • Class - 2

    Re-issue nov#35107300j public corridor partially obstructed @2nd storyadjoining office.chairs,desk,bookcases & misc.office equipment arranged in corridor.rem:remove obstructions.

    Feb 5, 2015

    Resolve
  • Class - 2

    Concrete walk cracked/spalling(trip hazards)various locations surrounding transportable units.rem:repair defects noted.

    Aug 15, 2014

    Resolve
  • Class - 2

    Reissue vio #35015868y.steel stair stringers,landing aprons & ramp approvs rusted through various locations around all transportable units.rem:repair &/or replace defects noted.

    Aug 15, 2014

    Resolve
  • Class - 2

    Reissue nov #35015867m.public corridor partially obstructed @ 2nd story adjoining main office office furniture & equipment arranged in public corridor.remove obstructions immediately.rem:maintain full corridor

    Aug 15, 2014

    Resolve
  • Class - 2

    Reissue vio #34958594n. steel stair stringer rusted/deteriorated at base. at transportable units designated t1 & t4. remedy: repair/replace defects noted.

    Apr 22, 2013

    Resolve
  • Class - 2

    Reissue vio #34958593l. public corridor partially obstructed by officefurniture/equipment and classroom furniture at 2nd and 3rd stys. remedy:remove obstructions maintain full corridor width in a code-compliant

    Apr 22, 2013

    Resolve
  • Class - 2

    Steel stair stringer rusted/deterior ated at base. at transportable units designated t1 & t4. remedy: repair defect noted.

    May 17, 2012

    Resolve
  • Class - 2

    Public corridors partially obstructed by office/class room furniture &supplies. at various locations throughout 2nd & 3rd stories. remedy: remove obstructions maintain full corridor width in a code compliant

    May 17, 2012

    Resolve
  • Class - 2

    Water penetrating building envelope. at rear facade various locations.remedy: repair defect noted maintain weather proof integrity of building envelope.

    May 17, 2012

    Resolve