roofy

1358 Odell Street

Bronx, NY 10462BBL 2-03934-0037Map

Owner of record: Dnf Builders INC

1358 Odell Street is a vacant lot in Bronx, 10462. The owner of record is Dnf Builders INC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
11
ECB violations
25
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 11

  • Construction other optional

    Soe drwgs,job#220152313,faild 2 meet min. req. outlined.in 3304.2 req plans w. all dimensions indicatd. soe-004 missng dims for the cant piles. the deficient dwgs r a hazard to public & prperty. remedy: stop all excavatn wrk.submit soe plans&calcs 4 proposd cantilevered soldier piles illustrated on soe-004 by 2/7/25

    Feb 5, 2025

    Dob violation - active
  • Construction other optional

    Stop all work immediately regarding revocation of approvals and permit s for job #220596086

    Jul 16, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 13, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 13, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 13, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 13, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 13, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 15, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 15, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 15, 2017

    Dob violation - dismissed
Show 1 more ↓
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 15, 2017

    Dob violation - dismissed

ECB violations · 25

  • Class - 2

    Temporary construction equipment or installation on site expired permit. as noted at time of inspection 6 story new building vacate land. observed plywood construction fence permit had expired on 07/30/2025. pe

    Jan 9, 2026 · Penalty $1,250

    Active
  • Class - 2

    Observed construction fence @ perimeter of jobsite. exposure 1 plywood panel for construction fence falling off and leaning as well as fence gate is off hinges and leaning creating a open gap with potential for

    Mar 7, 2025 · Penalty $1,000

    Resolve
  • Class - 1

    At time of inspection of a active jobsite during my inspection i noticed excavation work in progress observed hole not maintain 45 degree hole about approx 7 feet dept not support as per code 3304.4.4 codes sta

    Jan 3, 2025 · Penalty $5,000

    Resolve
  • Class - 2

    Job site fence not constructed or maintained; noted at exposure 2 of property line construction fence observed approximately 16 feet of construction fence panels unattached to posts and down on ground and on pa

    Jan 18, 2024 · Penalty $1,000

    Resolve
  • Class - 2

    Inactive closed jobsite, i observed existing construction jobsite fence (220152313-01-eq-fn) in places at lotline with expired fence permit with expiration dated 06/28/2018 and not renewed in both department bi

    Aug 30, 2023 · Penalty $1,250

    Resolve
  • Class - 2

    The temporary construction fence permit # 220252313-01-eq-fn at the vacant land expired on 06/28/2018. summons issued for expired fence permit., renew permit; renew permit.

    Jul 27, 2023 · Penalty $1,250

    Resolve
  • Class - 2

    Temporary construction equipment on site; expired permit: as noted at the time of my inspection observed that fence permit #220152313-01-eq-fn issued on 06-28-2017 and 6/28/2018 expired on further review of dob

    Jun 29, 2023 · Penalty $1,250

    Resolve
  • Class - 2

    Jobsite fence not maintained pursuant to subsection. at the time of my inspection of a 6 story nb, empty lot job not started. the job site fence at exp 2 is falling down, boards are broken and splintered creati

    Nov 21, 2018

    Resolve
  • Class - 1

    Failure to certify correction.the respondent failed to comply with an order of the commissioner issued pursuant to section ac28-201,1 oath summons no 35270016m with date of occurrece 08/25/2017.is in violation

    Feb 9, 2018 · Penalty $6,000

    Resolve
  • Class - 1

    Failure to certify correction-the respondent failed to comply with an order of the commissioner issued pursuant to section ac 28-201.1 oath summons #35270017y with date of occurrence 08/25/2017.hearing date was

    Jan 5, 2018

    Resolve
Show 15 more ↓
  • Class - 1

    Failure to certify correction-the respondent failed to comply with an order of the commissioner issued pursuant to section ac 28-201.1 oath summons #35270018x with date of occurrence 08/25/2017.hearing date was

    Jan 5, 2018

    Resolve
  • Class - 2

    The respondent (permit holder)failed to maintain the fence at 1358 odell st.bronxexposure #2 safe as mandated in bc 3307.7.7 bc3307.7.7 condition of fences states "all fences shall be installed,adjusted repaire

    Nov 14, 2017 · Penalty $400

    Resolve
  • Class - 1

    Work does not conform to approved construction documents &/or approvedamendments. at time of inspection observed an active construction site w/excavation work for support of excavation on progress,during inspec

    Aug 25, 2017 · Penalty $1,000

    Resolve
  • Class - 2

    Sec. 3301.2 missing rebar cap. at time of inspection observed construction site w/excavation work on progress,during inspection noted at exp#2,3&4 missing rebar cap. remedy: comply w/code.

    Aug 25, 2017 · Penalty $400

    Resolve
  • Class - 2

    Rcny 101-06(c)(1) the respondent is identified as the special insp appl for job no #220152313 per tr1 dated 05/20/17 & is not registered w/the dob to conduct those insps 1rcny 101-06(c)(1) mandates,"all agencie

    Aug 25, 2017 · Penalty $400

    Resolve
  • Class - 1

    Bc 107.7.1 the respondent failed to meet the minimum requirements of the code (ac 28-101.2) & produced foundation/cellar plan (fo-100.00 for job #220152313 that did not identify the bottom of adjacent footings

    Aug 25, 2017 · Penalty $1,600

    Resolve
  • Class - 1

    Work does not conform to approved construction documents &/or approvedamendments. at time of inspection observed an active construction site w/excavation work for support of excavation on progress. noted the co

    Aug 25, 2017 · Penalty $1,000

    Resolve
  • Class - 1

    Work does not conform to approved construction documents &/or approvedamendments. at time of inspection observed an active construction sitew/excavation wokr "foundation walls on progress,during inspection note

    Aug 25, 2017 · Penalty $500

    Resolve
  • Class - 1

    Bc 1704.1.2 the respondent has failed to perform the(responsibilities)of the special insp agencies bc 1704.1.2 mandates the special insp agency shall observe work subject to special insp to confirm that the wor

    Aug 25, 2017

    Resolve
  • Class - 2

    Sec. 3301.2 no guardrails. at time of inspection observed an active construction site w/excavation work on progress,during inspection noted the contractor failure to install guardrails at exp#3&4 when worker ar

    Aug 25, 2017 · Penalty $400

    Resolve
  • Class - 2

    Failure to comply w/astm c31 standard for concrete cylinder test samples.@time of insp observed an active const site w/excavation concrete & rebar work on progress,during insp noted the contractor has cylinder

    Aug 25, 2017 · Penalty $1,600

    Resolve
  • Class - 1

    Bc 3309.4.4;bc 3309.6 the respondent failed to identify the monitoring program (bc 3309.16)under job #220596086,professionally certied.drawings #g-001.00,f-001.00,f-002.00 included excavation/foundation coonst

    Aug 25, 2017

    Resolve
  • Class - 1

    Construction superintendent failed to perform duties as per rule. at time of inspection observed an active construction site w/excavation "support of excavation" on progress,during inspection noted the construc

    Aug 25, 2017 · Penalty $10,000

    Resolve
  • Class - 1

    Bc 1704.1; 1rcny 101-06(c)(1). bc 1704.1 requires that the special insp agencies meet ac 28-114.1 & ac 28-115.1 & are retained by the owner to provide insp during consts. @the time of insp,the respondent has fa

    Aug 25, 2017 · Penalty $1,600

    Resolve
  • Class - 1

    Bc 107.7.1 the respondent failed to meet the minimum reqs of the code (ac 28-101.2) & produced foundation/earthwork drawings for job #220596086,professionally certified that did not identify the bottom of adjac

    Aug 25, 2017 · Penalty $1,600

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Vacant lot (V1)
Year built
—
Floors
—
Residential units
—
Building area
—
Lot area
2,575 ft²
Zoning
R6
Community board
209
Council district
18
Block / lot
3934 / 37
Assessed value
$61,200
Landmark / historic district
No

Questions about 1358 Odell Street

Who owns 1358 Odell Street?

The owner of record in NYC Department of City Planning PLUTO data is Dnf Builders INC.

Does 1358 Odell Street have violations?

NYC HPD has no housing violations on record for this property.

Is 1358 Odell Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.