Violations at 1070 Castle Hill Avenue
Bronx, NY 10472 · BBL 2-03817-0001 · Back to the property
HPD housing violations
No HPD violations on record
DOB building violations
20 DOB violations, newest first.
- Low pressure boiler boiler required
Violation issued-failure to file 2024 external low pressure inspection
Nov 14, 2025
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2024 external low pressure inspection
Nov 14, 2025
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 17, 2020
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 7, 2000
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 7, 2000
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 7, 2000
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 7, 2000
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 16, 1999
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 16, 1999
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 9, 1994
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jun 9, 1994
Dob violation - dismissed - Construction other optional
C-construction other optional
Nov 12, 1992
Vpw*-violation unserved ecb-work without permit-dismissed
ECB violations
The newest 50 of 77 ECB violations. The city keeps the complete history.
- Class - 2
Emergency signs at elevator call stations missing defective or non-compliant with section requirements.noted:missing emergency sign at elevator call station on 3rd floor observed upon inspection.rem:install and
May 7, 2026 · Penalty $625
Active - Class - 2
Exit door not self-closing.noted:emergency exterior exit door not selfclosing due to binding,missing and or faulty hardware on exterior exitdoor at cafeteria/kitchen exterior exit 2 doors observed upon inspecti
May 7, 2026 · Penalty $625
Active - Class - 2
Failure to maintain building in code-compliant manner.noted:fire ratedclassrooms and smoke doors not self-closing due to binding,missing andor faulty hardware on classrooms 405,313,311,310,308,307,303,301,204,2
May 7, 2026 · Penalty $1,250
Active - Class - 2
Failure to maintain building in code-compliant manner.observed at cellar gasroom & electrical rooms water penetration,at walls & floors.rem:repair and/or replace.
Sep 23, 2024 · Penalty $625
Resolve - Class - 2
Failure to maintain building in code-compliant manner.observed at bulkheads stair a & g spalling walls water penetration.rem:repair and/or replace.
Sep 23, 2024 · Penalty $625
Resolve - Class - 2
Failure to maintain building in code-compliant manner:illumination forexits,exit discharges and public corridors per bc 1006.1;27-381.observed at 3 floor box#15,1 fl#31,basement#29 and 41 emergency lights are n
Sep 23, 2024 · Penalty $625
Resolve - Class - 2
Failure to maintain building in code compliant manner:lack of emergency lighting for exits,exit discharges and public corridors per bc1006.127-542.observed on 2nd,3rd,and 4th floor public corridors/staircase em
Jun 22, 2022 · Penalty $1,250
Resolve - Class - 2
Reissue#35582389h.failure to maintain building in code compliant manner.illumination for exit,exit discharges and public corridors per bc1006.1;27-381.observed on 2nd and 3rd floor,stair g existing emergency li
Jun 22, 2022 · Penalty $1,562
Resolve - Class - 2
Failure to maintain building in code compliant manner.provide requiredcorridfor width per bc1016.2;27-369.observed on 1st floor area of rescue assistance,corridors are being occupied by furniture,bicycles,cardb
Jun 22, 2022 · Penalty $625
Resolve - Class - 2
Failure to maintain building in code compliant manner:no fire stoppingper bc712.3;27-345.observed at cellar level,electrical room and gas meter room several opening due to pipe penetration and ceiling damages w
Jun 22, 2022 · Penalty $1,250
Resolve - Class - 2
Failure to maintain building in code compliant manner.observed on 4th floor gym,stair c door,seven classroom doors with disabled push open door system installed not working properly.also on 3rd floor(15)2nd flo
Jun 22, 2022 · Penalty $625
Resolve - Class - 2
Failure to maintain bldg in code compliant manner illumination for exits,exit discharges & public corridor per bc 1006.1;27-381. noted: missing emergency lights at 3rd fl & 2nd fl stair(g)exits & also observed
Jul 23, 2021 · Penalty $625
Resolve - Class - 1
97x17:97-x-17=entire device inoperative upon inspection arrival. entire device inoperative for several months pending a fire dept inspection. remedy perform necessary inspections and restore the device back to
Dec 1, 2020 · Penalty $3,125
Resolve - Class - 1
Restore device to service so that inspection can be made by this department.
Nov 12, 2020 · Penalty $1,250
Resolve - Class - 2
Reissue# 35221184k. failure to maintain bldg in code compliant manner lack of emergency lighting fox exits, exit discharges & public corridors per bc 1006.1; 27-542. emergency lights are not working in the cafe
Jun 29, 2017
Resolve - Class - 2
Failure to maintain bldg in code compliant manner. lack of emergency lighting for exits,exit discharges & public corridors: emergency lighting not working outside of stair'b'all floors,1 light is out in the
Nov 15, 2016
Resolve - Class - 2
Support bracket rusted/dislodged from fl.@ bsmt boys bathroom stall flbracket.rem:repair &/or replace.
Aug 25, 2014
Resolve - Class - 2
Doors not closing.@ 1st fl.stair b landings between 1st fl & bsmt.2 doors(up & down sides),exit 1 vestibule doors.@ general office(door railsplit @ lockset side).rem:repair &/or replace doors noted
Aug 25, 2014
Resolve - Class - 2
1- room 414 - door and frame dislocated. 2- interior door, 1st flr exit #5. door braced to function. remedy: maintain door and frames as percode.
May 8, 2013
Resolve - Class - 2
Roof drain clogged (watson street side). remedy: maintain drains as per code.
May 8, 2013
Resolve - Class - 2
Reissue 34958010k. water penetration at ceiling and walls, stairwell c, rooms 408,406,403,402, rooms 306,351,350,315, corridor wall near room 250, room 250,215,208,202,gym, kitchen wall at exit 4, girls room
May 8, 2013
Resolve - Class - 2
Reissue 34958011m near stair 4th flr - provides egress in 2 directions- cross corridors doors, stair b at 2nd flr - cross corridors (2) doors for egress only. remedy: provide doors w/egress and ingress.
May 8, 2013
Resolve - Class - 2
Door swings opposite flow of egress. at: 3rd floor double action crosscorridor doors replaced by single action doors (exit signs above both sides of doors) corridor provides egress in 2 directions.
May 3, 2012
Resolve - Class - 2
Reissue #34926125y water damaged plaster walls & ceilings. at various locations throughout all levels/floors. remedy: repair &/or replace defects noted.
May 3, 2012
Resolve - Class - 2
Re-issue #34926126x water/weather penetrating building envelope. at various locations throughout from cellar to 4th floor. remedy: repair defect noted maintain weatheer proof integrity of building envelope.
May 3, 2012
Resolve - Class - 2
Doors not closing - at: 1st story exit 6 discharge doors,boiler room door. at: 2nd story cross corridor doors near rm 212 at: 3rd story stair b & stair c at: 4th story stair c,stair b,stair g (3 doors),gym
May 3, 2012
Resolve - Class - 2
Roof access gate padlocked at stair c 4th story. remedy: provide code-complaint hardware.
Aug 12, 2011
Resolve - Class - 3
Missing handrail/broken handrail support bracket. at stair c between basement & 1st story handrail support bracket weld broken. remedy: provide handrail & support bracket.
Aug 12, 2011
Resolve - Class - 2
Doors not closing at: basement level: room b01,exit 3,exit2,door brwn janitorial closet & kitchen,exit 5 & exit 8. 1st story;exit 1,stair b 2nd story;stair g,room 207a,253,211 & stair c 3rd story;stair b (2 doo
Aug 12, 2011
Resolve - Class - 2
Reissue #34861866r water penetrating roof & facade various locations throughout causing damage to interior ceilings,walls & floors. remedy: repair/maintain weatherproof integrity of bldg.
Aug 12, 2011
Resolve - Class - 2
Reissue 34861867z spalling/cracked/water damaged plaster stair c 1st story thru roof bulkhead & 5th story fan room,rooms 215,315,auditorium near stair c & various locations throughout 4th story. remedy: repair
Aug 12, 2011
Resolve - Class - 2
Failure to maintain adequate fire stopping observed: inadequate fire stopping in electric room in cellar around conduit which feeds electricpanel mounted outside electric room. remedy: maintain fire stopping.
Jul 9, 2010
Resolve - Class - 2
Reissue: 34761663z observed: spalling/cracked plaster on walls and/or eilings in 5fl fan room & bulkhead 4fl star c,406,402,215,hallway beam outside rm 208. remedy: maintain building.
Jul 9, 2010
Resolve - Class - 2
Reissue: 34761662r observed: water penetration into building from exterior at sfl fan room & bulkhead,4 fl stair c,406,402,215. remedy: maintain building.
Jul 9, 2010
Resolve - Class - 2
Reissue: 34466327h the plaster on the wall is spalling off the wall. located on room 202,204 2nd flr,room 304,306 3rd flr level,gymnasium 4th flr level adjacent to the windows & storage room 514 & fan room 5th
Feb 26, 2009
Resolve - Class - 2
Reissue: 34576962y window lintels & brick facade has become porous & allowing rain water into the building causing interior damages on the 2nd,3rd,4th & 5th flr exterior stucco finish on the north side is spall
Feb 26, 2009
Resolve - Hazardous
27-127 corridor smoke doors are missing located at the 2nd floor by room 207 leaving door frame door across the auditorium is missing located on the 1st floor lvl rem: replace missing doors
Apr 3, 2008
Resolve - Hazardous
27-127 concrete is spalling from the column located in the electrical room at cellar level rem: repair concrete column
Apr 3, 2008
Resolve - Hazardous
27-127 reissue: 34576961m plaster on the ceiling is spalling located in the fan room on the 5th floor rem: repair plaster on the ceiling
Apr 3, 2008
Resolve - Hazardous
Reissue vi #34466325y. defective motor lentels & bricks location thru out exterior of bldg. remedy: repair or replace defective/ exterior ofbldg.
Jun 29, 2007
Resolve - Hazardous
Reissue vi 34393639m. spalling plaster 5 fl fan room storage room 4 flgym, gym office cafeteria over exit h. remedy: repair defect above locations.
Jun 29, 2007
Resolve - Non-hazardous
Failure to maintain bldg - interior. 5fl fan rm, storage rm, 4fl gym, gym office, cafeteria over exit door h. plaster is spalling & falling.remedy: repair plaster.
Jun 1, 2006
Resolve - Non-hazardous
Failure to maintain bldg - interior. door closer broken @the followingloc: 1fl -stairway g(2)dr, stairway b(1)dr, 4fl -stairway c(1)dr -stairway g(1)dr, corridor fire/smoke dr by rm405.
Jun 1, 2006
Resolve - Non-hazardous
Reissue #34466330z failure to maintain bldg - interior corridor fire/smoke doors missing in the following loc: 2f -rm#205(2)dr, rm#257(2)dr,rm#306(1)dr. remedy: replace missing doors.
Jun 1, 2006
Resolve - Non-hazardous
Reissue #34206656h,#34307799h,#34258221n,#34385731p failure to main tain bldg - exterior. stucco on retaining wall is cracked, loose & falling away. remedy: repair as needed.
Jun 1, 2006
Resolve - Non-hazardous
Water penetration- roof leaks onto 4th floor class rooms, corridors, and bulkheads. remedy: repair all roof leaks.
Feb 4, 2005
Resolve - Non-hazardous
Miss smoke doors in corridors location :outside of room #r.306 (1) door r.257 (2)doors r-205 (2) doors remedy:replace missing doors
Feb 4, 2005
Resolve - Hazardous
Reissue #34423433l defective stucco coating allowing water penetrationlocation court yard walls @ north south east west remedy:repair stucc o & water proof walls
Feb 4, 2005
Resolve - Non-hazardous
Reissue # 34423434n (repair)defective plaster ceilings at class rooms & star wells & corridors on 3rd & 4th floor and at fan room and roof bulkheads remedy:repair defective plaster
Feb 4, 2005
Resolve - Hazardous
Defective lentels north mortar missing from bricks at lentels location north facade fl#3 & 4 remedy:lentels & defective masonary
Feb 4, 2005
Resolve