Violations at 4310 Katonah Avenue
Bronx, NY 10470 · BBL 2-03386-0001 · Back to the property
HPD housing violations
No HPD violations on record
DOB building violations
10 DOB violations, newest first.
- Low pressure boiler boiler required
Violation issued-failure to file 2024 external low pressure inspection
Nov 14, 2025
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2024 external low pressure inspection
Nov 14, 2025
Dob violation - active - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 13, 2004
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 13, 2004
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 13, 2004
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 13, 2004
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 19, 2003
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 19, 2003
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 26, 2002
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 26, 2002
Dob violation - dismissed
ECB violations
The newest 50 of 51 ECB violations. The city keeps the complete history.
- Class - 2
Failure to maintain building in code-compliant manner. noted: classroom interior doors do not self-close properly at 3rd flr-312, 305, 352. 2nd flr-213. remedy: repair and/or replace.
Apr 6, 2026 · Penalty $1,250
Active - Class - 2
Re-issue #35720015x. exit door not self-closing. noted: on 1st floor "exit 2" exterior door does not self-close when tested. remedy: repair/replace door.
Apr 6, 2026 · Penalty $1,562
Active - Class - 2
Failure to maintain building in code-compliant manner. illumination for exits, exit discharges and public corridors per bc 1006.1; 27-381. at the time of inspection observed and noted at 1st floor old gym area
Jun 3, 2025 · Penalty $1,250
Resolve - Class - 2
Reissue: 35665148k date of issue: 02-07-2023. exit door not self-closing properly at the time of inspection. observed and noted at exit #2, #, #5 and #6 exterior wooden doors and 1st floor stairway "c" one exit
Jun 3, 2025 · Penalty $625
Active - Class - 2
Failure to maintain building in code-compliant manner.note:observed at4th floor corridor,drop ceiling tiles are staired & showing signs of water penetrations coming from the roof when it is raining.rem:repair a
Feb 7, 2023 · Penalty $625
Resolve - Class - 2
Failure to maintain building in code-compliant manner.note:observed inclassroom# 329 & #231(fire rescue holding room)fdny access window has cracked window panels that can cause a hazard.rem:repair and/or replac
Feb 7, 2023 · Penalty $625
Resolve - Class - 2
Failure to maintain building in code-compliant manner.note:observed atexit#5 & #6 interior doors are in state of disrepair due to dragging on the floor and not operating properly when tested.rem:repair and/or r
Feb 7, 2023 · Penalty $625
Resolve - Class - 2
Exit door not self-closing.note:observed at exit#2,#4,#5 & #6,exteriorwooden doors are in state of disrepair and not closing properly when tested.rem:repair/replace door.
Feb 7, 2023 · Penalty $625
Active - Class - 2
Failure to maintain building in code-compliant manner:use of prohibited door and/or hardware per bc 1008.1.8;27-371(j).note:observed at 3rd floor classroom(door frame)#313,312,310,309,308 & 306(holding fire res
Feb 7, 2023 · Penalty $625
Resolve - Class - 2
Altered/changed building occupied without a valid certificate of occupancy as per 28-118.3.1-28-118.3.2.note:at time of inspection observed the 4 story school building is currently occupied with students,teache
Feb 7, 2023 · Penalty $1,250
Resolve - Class - 2
Failure to institute safety measures note:at time of inspection where worker got injured on 2-22-21 when he fell off baker's scaffold photosprovided by super dimitrois# 26789 showed baker scaffold missing guard
Feb 22, 2021 · Penalty $5,000
Resolve - Class - 1
Bc 3301.8.1 use and tampering prohibited note:at time of inspection where it was reported that worker got injured when he fell off baker's scaffold on 2-22-21:upon inspection where the incident happened it show
Feb 22, 2021 · Penalty $2,500
Resolve - Class - 1
Failure to notify(incident)note:at time of inspection where it was reported that worker got injured when he fell off baker's scaffold on 2-22-21 and was taken to hospital and who is still in hospital from injur
Feb 22, 2021 · Penalty $5,000
Resolve - Class - 1
Scaffold use without 4 hr certificate note:at time of my inspection at3 sty school where it was reported that a worker got injured on 2/22/21 when he feel off baker scaffold upon request to see his 4 hour user
Feb 22, 2021
Resolve - Class - 2
Failure to provide pe approved design drawings. as noted at time of inspection, active site, i observed 3 pully system insalled at exp#3 at 4th floor used for lifting up materials and cmu blocks.rmdy: stop all
Sep 11, 2018
Resolve - Class - 2
Failure to maintain exit stair case doors 3 and 4 on 3rd floor ra() not working properly. sticking on floor. rmdy: replace.
Feb 27, 2018
Resolve - Class - 2
Reissue 35719346n. at cellar boiler room fire proof coating missing on steel hangers and where hangers are attached. rmdy: repair or replace.
Feb 27, 2018
Resolve - Class - 2
Reissue# 35018405l. failure to maintain bldg in code compliant manner.@ boiler room no fire proofing @ beams where gas line hangers are anchored expose wire mesh @ ceiling. rem: comply w/ nov.
Aug 1, 2016
Resolve - Class - 2
Operation of a place of assembly w/o a current c of o. at 1st fl main entrance lunch room/6/m area & auditorium pa not updated. remedy: obtain a place of assembly c of o.
Apr 29, 2015
Active - Class - 2
Reissue vio#35099761p. inadequate support brackets for window air con ditioners at west elevation exp1 above main entrance. rmdy: provide code compliant air conditioning support brackets.
Jan 20, 2015
Resolve - Class - 2
Reissue nov #350099763z. at cellar boiler room fire proof coating missing on steel beams above gas supply piping lines. rmdy: repair defect noted.
Jan 20, 2015
Resolve - Class - 2
Reissue nov #35018405l @ boiler room above gas supply piping fire proof coating missing on steel beams.rem:repair & or replace defect noted.
Jul 14, 2014
Resolve - Class - 2
Reissue vio #35018406n inadequate support brackets for window a/c units above main entrance west elevation(exposure 1)(wood used;steel required).rem:provide code compliant support brackets manitain bldg walls &
Jul 14, 2014
Resolve - Class - 2
Auditorium - add single row of portable metal chairs - now corridor width to exit is 27". remedy: provide proper width for egress.
May 20, 2013
Resolve - Class - 2
Front facade above main entrance 2 a/c units supported by 2 wood blocks. remedy: support a/c units as per code.
May 20, 2013
Resolve - Class - 2
Boiler room - no fire proofing at beams where gas line hangers are anchored. above gas meter room - ceiling exposed wire mesh not fireproofed. remedy: install fire proofing as per code.
May 20, 2013
Resolve - Class - 2
Water penetrating foundation walls & pooling on concrete floor variouslocations throughout: boiler room & gas meter room at cellar. remedy: repair/maintain waterproof integrity of foundation walls.
Aug 16, 2011
Resolve - Class - 2
Doors not closing. at: 1st story stair a (cafeteria exit) 2 doors,stair c (exit 6) 5 doors (2 & 3) 3rd story stair b. remedy: replace doors.
Aug 16, 2011
Resolve - Class - 2
The electrical room is lacking fire-stopping around the pipe penetration leaving open gas @ the cellar level.remedy:provide/maintain fire-stopping.
Jul 8, 2010
Resolve - Class - 2
Operation of place of assembly w/o a current cofo.noted:place of assembly cofo#200332639 is issued on:3/27/09 & expired on 3/27/10 which leaving cafeteria space/playroom area w/o a valid cofo.rem:immediately ob
Jun 23, 2010
Active - Class - 3
Failed to maintain: note: mortar missing from brick joists. location above 3rd flr windows on 237st & 238 st. remedy: maintain bldg wall.
Feb 26, 2009
Resolve - Non-hazardous
Exit passage or corridor. required width decreased by obstruction noted: corridor hallway has mini classrooms session located by room 305 & 306 o the 3rf flr level. consisting of tables & chairs & books. remedy
Apr 11, 2008
Resolve - Non-hazardous
Concrete ceiling is cracked located in the electrical room on cellar level. remedy: repair/replace concrete ceiling.
Apr 11, 2008
Resolve - Hazardous
Interior plaster is spalling on the wall located at 1) staircase leading to boiler rm between 1st & basement level & 2)room 357 on the 3rd fl level.remedy repair plaster on walls
Aug 23, 2007
Resolve - Non-hazardous
"re-issue" 34424132m. wooden window frames and sashes rotted at all floors all windows. remedy: replace windows frames/sashes.
Feb 10, 2005
Resolve - Hazardous
Reissue:failure to maintain defect noted wood frames & sashes rotted wood sashes nailed shut to prevent them from falling out ballusts inoperoble windows crashing down of collapsing onto street or children in
Jan 5, 2004
Resolve - Hazardous
Failure to maintain. defect noted: wood frames & sashes rotted & loose baldusts are broken causing windows to collapse some nailed shut. location: entire building. remedy: change all windos: make safe maintain
May 2, 2003 · Penalty $2,500
Resolve - Hazardous
Required means of egress obstructed 1 egress passageway use as a storage room bxes, metal cabinets and classroom decks atn the south and north ecit door ways. remedy; remove all items from passageways.
Jun 10, 2002
Resolve - Hazardous
Requires means of egress obstructed egress passageway used as storage room boxes folding table metal cabinets at the south and north exit doorway remedy remove all items
Mar 19, 2002
Resolve - Non-hazardous
Reissue failure to maintain defect is: steps at rear of premises are spalling and has uneven seltbement of treads and resers. remedy: make all necessary repair.
Mar 5, 2002
Resolve - Hazardous
Reissum failure to maintain defect is: the entire first floor and various locaiton above floors windows are defective and spalling rotten wood sasltes. remedy; replace all defective windows.
Mar 5, 2002
Resolve - Non-hazardous
Failure to maintain.defect is:roof leaks at room #256, 260 and water penetration room #211,311,308 and 309.remedy:stop all leaks and water penetration into classrooms.
Apr 24, 2001
Resolve - Hazardous
Failure to maintain.defect is(hazardous)the school.sashes and windows sills are rotten allowing water penetration into classrooms.some sashes,locked in fixed positions with loose putty at window panes.remedy:re
Apr 24, 2001
Resolve - Non-hazardous
Failure to maintain.defect is:steps at rear of premises are spalling,have uneven settlement of treads and risers and major trip hazards.remedy:remove hazards,replace defective steps.
Apr 24, 2001
Resolve - Non-hazardous
Failure to provide 3 inch high alphabetic letter of identification for stair over the occupancy side of the stair's door on floor 1 to 3.failure to provide 3 inch high numerical sign indicating floor number wit
Mar 15, 2001
Resolve - Non-hazardous
Failure to provide emergency light eixture within corridor and stair(7) on 2nd and 3rd floor.failure to provide emergency powr to lighting exiture within corridor and stairs(7)on 2nd and 3rd floor.remedy:provid
Mar 15, 2001
Resolve - Non-hazardous
Failure to maintain.defect is: 1)throught top fl. classrooms, hallway and stairwells water damaged walls and ceiling.2)deterioating parapet walls joints at brick are open:3)rotten sashes and inoperable windows
Feb 29, 2000
Resolve - Non-hazardous
Failure to maintain exterior. defects are: rear wall of school needs water proofing, throughout. also plaster is spalling in classroom. remedy: make all necessary repair.
Apr 15, 1999
Resolve - Non-hazardous
Failure to maintain. paint peeling and plaster cracked and falling on the entire 2nd floor classrooms, bathrooms, boys and girls and teachers. 1st floor same condition.
Nov 15, 1995
Resolve - Hazardous
Metal partitions separating toilets are rotted on bottom creating jagged rusty edges.
Oct 12, 1994
Resolve