Violations at 376 St Anns Avenue

Bronx, NY 10454 · BBL 2-02557-0001 · Back to the property

HPD housing violations

No HPD violations on record

DOB building violations

18 DOB violations, newest first.

  • Low pressure boiler boiler required

    Violation issued-failure to file 2024 external low pressure inspection

    Nov 14, 2025

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2023 external low pressure inspection

    Sep 23, 2024

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2021 external low pressure inspection

    Jun 30, 2023

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2018 external low pressure inspection

    Jun 20, 2023

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2022 external low pressure inspection

    Apr 25, 2023

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2017 inspection report

    Nov 8, 2019

    Dob violation - dismissed
  • Construction other optional

    C-construction other optional

    Oct 29, 2019

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2016 inspection report

    Apr 6, 2018

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2015 inspection report

    Feb 24, 2017

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2014 inspection report

    Oct 1, 2015

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2013 inspection report

    Mar 3, 2015

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Lblvio-low pressure boiler boiler required

    Dec 31, 2009

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 1, 2009

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 3, 2008

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 19, 2007

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 6, 2006

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 31, 2005

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 13, 2004

    Dob violation - dismissed

ECB violations

10 ECB violations, newest first.

  • Class - 1

    During my inspection. i observed the exterior courtyard an installed pipe scaffold that was not fully planked, no guardrail system, not nailed down to the mudsills, and no adequate means to access the top level

    Sep 29, 2025 · Penalty $5,000

    Resolve
  • Class - 2

    3 story st. mary's recreation center parks department building observed support of excavation work at exp#3. construction super onsite site safety jobsite permit#x01206566. upon request for site safety plans on

    Jul 10, 2025 · Penalty $1,250

    Active
  • Class - 1

    3 story st. mary's recreation center parks department building observed support of excavation work at exp#3. excavated area more than 10 feet in depth piles lagging & shoring. upon research on bis/dob now & crm

    Jul 10, 2025 · Penalty $2,500

    Active
  • Class - 2

    Failure to provide pre-shift meeting and site safety orientation logs, and site safety plan failure to provide dob approved drawings

    Sep 16, 2022

    Resolve
  • Class - 2

    Failure to provide super logs failure to designate competent person

    Sep 16, 2022 · Penalty $5,000

    Active
  • Class - 1

    An unlawful act-failure to comply with an order of the commissioner.failure to correct and certify summons numbers#35360017n,35360018p,and 35547840j.remedy:comply with ec code.

    Oct 9, 2021 · Penalty $12,500

    Active
  • Class - 1

    Unlawful acts. failure to comply with an order of the commissioner. record indicate no application was made to certify and correct ecb #'s 35360018p & 35360017n. remedy: comply with commissioners orders

    May 5, 2021 · Penalty $2,500

    Active
  • Class - 1

    Failure to properly bond electrical systems.basement electrical room.1200 ave service entrance conductors are not bindee, and grounded."please note"this is not a final inspection!!remedy:provide proper bonding.

    Nov 22, 2019 · Penalty $3,000

    Active
  • Class - 1

    Unapproved,unsafe,unsuitable electrical equipment apparatus,materials,devices,or wiring in use.basement electrical room:defective entrance conductor,window service,entrance through q/m temporary wiring and not

    Nov 22, 2019 · Penalty $1,600

    Active
  • Class - 1

    (swo #040612fc01) failure to safeguard all persons affected by construction operations. (while moving man lift the operator of man lift did not have a watch man & he made contact w/crane putting the crane in

    Apr 6, 2012 · Penalty $2,400

    Resolve