Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 2

  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 22, 2024

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 3, 2023

    Closed — Violation dismissed

DOB building violations · 16

  • Failure to post energy grade/score none

    Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3

    Dec 1, 2021

    Dob violation - dismissed
  • Failure to post energy grade/score none

    Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3

    Apr 29, 2021

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Feb 3, 2021

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Nov 2, 2020

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 2, 2020

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2020

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 4, 2019

    Dob violation - resolved
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 25, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 25, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 25, 2018

    Dob violation - dismissed
Show 6 more ↓
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 25, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 25, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Feb 21, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 4, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    May 4, 2016

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Apr 6, 2016

    Dob violation - dismissed

ECB violations · 33

  • Class - 1

    Class 1 rts: failure to maintain building in code compliant manner. service elevator equipment as per bc3001.2 & 27-987. upon inspection, the device is found to be out of service, creating a hazardous condition

    Oct 15, 2026 · Penalty $1,250

    Active
  • Class - 1

    Class 1 c/u: firefighters' service phase i switch inoperative; key cannot be removed from the switch, as per asme a17.1 2.27.3.1. remedy: repair/replace switch to restore proper operation and key removal. email

    Oct 15, 2026 · Penalty $1,250

    Active
  • Class - 2

    Miscellaneous violation of the electrical code technical standards. observed on the roof the hot water tank room has no remote shutdown at the point of egress for emergency use. remote shutdown must be at the p

    Oct 15, 2026 · Penalty $800

    Active
  • Class - 2

    Atoi observed excessive storage of combustible materials of carboard boxes, paint buckets, and construction materials in the water meter and fire pump room. contrary to 315.2.3 equipment rooms. combustible mate

    Oct 15, 2026 · Penalty $1,250

    Active
  • Class - 1

    Failure to maintain building in code-compliant manner: use of prohibited door and/or hardware per bc 1008.1.8 (2014 code); 27-371; bc 1008.1.9 (2014 code); bc 1010.1.8 (2022 code); bc 1010.1.9 (2022 code).obser

    Aug 8, 2025 · Penalty $6,250

    Resolve
  • Class - 1

    Unsafe storage of combustible material and equipment. observed unsafe storage under stair case.(linen,lamps,boxes,janitorial supplies and misc items) underneath both stair cases. main lobby and 1st fl. potentia

    Aug 8, 2025 · Penalty $6,250

    Resolve
  • Class - 1

    Failure to maintain building in code-compliant manner: no fire stopping per bc 712.3 (2014 code); 27-345; bc 711.2.4 (2022 code.observed hole penetrations covered with vent covers. located at 1st fl lobby. pote

    Aug 8, 2025 · Penalty $12,500

    Active
  • Class - 2

    Class 2:rts failure to maintain building in code compliant manner. service elevator equipment as per bc3001.2 & 27-987. upon inspection, the device in the section of the building is found to be out of service,r

    Aug 1, 2025 · Penalty $310

    Resolve
  • Class - 2

    Observed temporary hose valve caps( red plastic) installed throughout building. as per 3308.7 of the fire code, temporary coverings shall be immediately removed after the construction is complete., repair and/o

    Aug 29, 2024

    Resolve
  • Class - 1

    I observed in the halls on all floors the failure to install tamper resistant receptacles as per ll 39/ 2015.; ll 39/2015, comply with ec code; install tamper-resistant receptacles

    Aug 29, 2024 · Penalty $800

    Resolve
Show 23 more ↓
  • Class - 1

    I observed on the floors the electrical closet not dedicated to electrical distribution equipment only. the installation of the data wiring, and data equipment is not permitted as per nec. please note the data/

    Aug 29, 2024

    Resolve
  • Class - 1

    I observed in the water meter room the failure to install the water meter jumper as a required part of the electrical grounding system. failure to install/ maintain the water meter jumper could result in a loss

    Aug 29, 2024 · Penalty $4,800

    Resolve
  • Class - 2

    Provide an updated maintenance log. clean top of car .clean entire pitarea.

    Aug 13, 2024

    Resolve
  • Class - 2

    Provide an updated maintenance log.clean entire pit area. clean top ofcar.

    Aug 13, 2024

    Resolve
  • Class - 1

    Sec. 3303.7.2 fire extinguishers. at the time of inspection of new bldg under construction i observed at every floor throughout bldg. at both stairways,fire extinguishers not properly mounted & being used to

    Apr 25, 2018 · Penalty $6,250

    Resolve
  • Class - 1

    No site safety plan. at the time of inspection of new bldg under construction no site safety plan was provided or made available upon request. remedy: stop all work entire site. comply w/code contact best for

    Apr 25, 2018 · Penalty $12,500

    Resolve
  • Class - 1

    No site safety coordinator on site. at the time of inspection of new bldg under construction i observed approx 4 construction workers on site. it was told to mg by the project superintendent that the ssc was no

    Apr 25, 2018 · Penalty $25,000

    Resolve
  • Class - 1

    Sec. 3310.8.4 no daily log book/site safety log. at the time of inspection of new bldg under construction. no site safety log was provided or made available upon request. remedy: stop all work entire site. comp

    Apr 25, 2018 · Penalty $12,500

    Resolve
  • Class - 1

    Housekeeping. at the time of my inspection of new bldg under construction i observed at the 4th fl setback at exp#3 construct. material & debris consisting od plywood,empty pallets,duct work,2x4's,cardboard box

    Apr 25, 2018 · Penalty $6,250

    Resolve
  • Class - 2

    Fence. at the time of my inspection of new bldg under construction,i observed that the chain link fence at exp#1&3 are not solid. fence was not solid/built out of suitable material. remedy: comply w/code.

    Apr 25, 2018 · Penalty $2,000

    Resolve
  • Class - 2

    Work w/out a permit: expired nb permit. note: 11 story bldg topped & enclosed. observed approx 5-7 workers on site interior tracks setting of scaffolds installing trim. nb# 220211241 expired on 11/11/17. no new

    Nov 20, 2017 · Penalty $400

    Resolve
  • Class - 1

    Failure to have site safety coordinator on site. note: 1 story bldg erected to 11 flr enclosed. observed 5-7 workers on site w/ no hard hats, no boots, obstructed hallways, ssc arfan mahood is registered as ssc

    Nov 20, 2017 · Penalty $10,000

    Resolve
  • Class - 1

    Failure to perform hydrostatic pressure test for standpipe. bldg topped at 11 stories above the 75' elevation height.partial stop work orderissued & posted. rem: discontinue all work above 75'. provide passed h

    Jul 3, 2017 · Penalty $2,400

    Resolve
  • Class - 2

    Work w/out a permit. nb permit# 220211241 expired on 5/11/17. @ time of insp observed 3 workers @ exp#1 ground flr working on a deck including some concrete work. full stop work order issued & posted. rem: disc

    Jul 3, 2017 · Penalty $400

    Resolve
  • Class - 2

    Sec. 3301.2 failure to safeguard public & properties. numerous treadedscrews used in the (section) of sidewalk shed are sticking out of posts focing inward toward pedestrians traffic have not been capped as

    Jul 23, 2016 · Penalty $2,000

    Resolve
  • Class - 2

    Temporary construction equipment on site,expired permti fence permti for job site fence (permit #220211241) expired on 7/15/16. remedy: renew permit for fence.

    Jul 23, 2016 · Penalty $2,000

    Resolve
  • Class - 2

    Failure to provided required sidewalk shed parpet panel/sign sign has not been provided on sw shed parapet. shed runs the entire length of site along sedgwick ave. note: site closed at time of inspection(sat)

    Jul 23, 2016 · Penalty $2,000

    Resolve
  • Class - 1

    Sec. 3310.5.2 no site safety manager on site. noted: at time of inspection no site safety manager on site. new bldg job site is active. stopall work. provide site safety manager. contact sst for re-inspection.

    Feb 2, 2016 · Penalty $1,600

    Resolve
  • Class - 2

    Sec. 3314.4.3.2.1 failure to provide installation inspection report for suspended scaffold. noted: at time of inspection suspended scaffoldsinstalled at exp#2 & 4. no installation inspection report was provided

    Feb 2, 2016 · Penalty $400

    Resolve
  • Class - 2

    Sec. 28-105.12.2 partial swo issued for suspended scaffold pursuant 28-207.2 & posted on premises. noted: at time of inspection life lines & tiebacks missing protection on the corners of bulkhead which is contr

    Feb 2, 2016 · Penalty $250

    Resolve
  • Class - 2

    Failure to provide approved/accepted plans at jobsite at time of inspection.as noted: at time of inspection at an active construction.bldg is a 11 story reinforced concrete no structural plans.onsite,was state

    Jan 15, 2016 · Penalty $250

    Resolve
  • Class - 1

    Failure to institute/maintain safety equipment or temporary construction (no guardrails). as noted:at time of inspection at active site observed missing guardrails on 8th,9th,10th flrs. failure to maintain guar

    Jan 15, 2016 · Penalty $1,200

    Resolve
  • Class - 2

    Bc3301.2 failure to cover holes, and institute/maintain safety equip ment measure or temporary construction as noted: at time of inspectionat an active construction observed cut out holes in floors at 5th and

    Jan 15, 2016 · Penalty $1,200

    Resolve

Complaints

  • Heat/hot water

    Apartment only

    Feb 23, 2026 · Apt 4J

    Close
  • Safety

    Window guard broken/missing

    Oct 11, 2020 · Apt 602

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Hotel (H3)
Year built
2015
Floors
11
Residential units
—
Building area
33,057 ft²
Lot area
8,170 ft²
Zoning
M1-5
Community board
204
Council district
16
Block / lot
2523 / 53
Assessed value
$3,785,850
Landmark / historic district
No

HPD registration #228640, last renewed May 20, 2025.

Questions about 926 Sedgwick Avenue

Who owns 926 Sedgwick Avenue?

The owner of record in NYC Department of City Planning PLUTO data is Sitaram LLC.

Does 926 Sedgwick Avenue have violations?

Yes. NYC HPD has recorded 2 housing violations at this property.

Is 926 Sedgwick Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 926 Sedgwick Avenue built?

City records list 2015 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.