HPD violations
0
DOB violations
5
ECB violations
30
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 5

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Apr 3, 2024

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 29, 2023

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 22, 2023

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 15, 2023

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 7, 2011

    Dob violation - dismissed

ECB violations · 30

  • Class - 2

    3314.1observed supported scaffolding installed @ expo 4 of jobsite approx. 61 ft in height. the supported scaffolding is missing required cross bracing in multiple locations, guardrails/toe boards. spacing betw

    Feb 17, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    Observed sidewalk shed installed @ expo 1 & 4 and scaffolding seated on shed 2 expo 4. upon request for required documents 6 month inspection letters, daily logs for shed and loads imposed letter, none were pro

    Feb 17, 2026 · Penalty $1,250

    Resolve
  • Class - 2

    On roof level of active jobsite, observed large amounts of snow and ice accumulated w/out any measures of removal taking place. these conditions cause fall and tripping hazards.remove all snow and ice from roof

    Feb 17, 2026 · Penalty $1,250

    Resolve
  • Class - 2

    Observed sidewalk shed approx. 8ft in height installed @ exposures 1 & 4 of jobsite. the shed has large amount of snow and ice accumulated w/out measures of removal being implemented. as per 3307.6.5.5 & bc-33

    Feb 17, 2026 · Penalty $2,400

    Resolve
  • Class - 1

    Observed sidewalk shed missing cross braces & posts installed contrary to plans w/ deck overloaded w/ large structural steel i-beam stored, and an excessive amount of temporary equipment stored throughout the d

    Sep 7, 2025 · Penalty $2,530

    Resolve
  • Class - 1

    Observed pipe scaffold installed @ expo 4 w/out debris reaching above 40 feet in height while construction operations remain unfinished, pipe scaffold on top deck of sws that was installed contrary to plans. as

    Sep 7, 2025 · Penalty $5,030

    Resolve
  • Class - 2

    As per bc-3307.4.7 observed street occupancy for temporary storage w/ yodoks scattered and not connected w/ vehiculcar traffic in the area.maintain street occupancy/ storage zone as per code.

    Sep 7, 2025 · Penalty $2,530

    Resolve
  • Class - 2

    At time of inspection, observed sidewalk shed at exposure 1. sws extends to adjacent property of exposure 4 covering their driveway. vertical members are not secured against displacement, inadequate high visibi

    Aug 17, 2024 · Penalty $2,530

    Resolve
  • Class - 2

    On proposed 6 story new building jobsite, observed 2 workers performing welding operations. upon review on sst validator app, both workers (gyan heeralu & rudolph seymour) had revoked sst cards. gc failed to en

    May 9, 2024 · Penalty $2,530

    Resolve
  • Class - 2

    On active jobsite observed structural i-beams with make-shift wood supporting q-decks on 1st and 3rd floors. q-deck in said locations warped/bowing due to concrete loads. upon review of dob approved drawings,

    May 9, 2024 · Penalty $1,280

    Resolve
Show 20 more ↓
  • Class - 2

    Observed ongoing construction operations on 6 story proposed new building jobsite. structural work has been done throughout jobsite, currently @ 4th fl. upon review of dob records it shows that structural permi

    May 9, 2024 · Penalty $1,280

    Resolve
  • Class - 1

    On active jobsite observed on 4th floor working deck inadequate fall protection provided at various locations. the elevator shaft, stair well opening and edge of working deck @ exposure 2 no guardrails/safety

    May 9, 2024 · Penalty $5,030

    Resolve
  • Class - 2

    3309.14 protection of windows- observed ongoing construction operations on 4th floor working deck of jobsite. no window protection has been provided to the adjacent property at exposure 2 rear yard windows. sto

    May 9, 2024 · Penalty $2,530

    Resolve
  • Class - 1

    Controlled inspections of the stability 1 rcny 16-01- observed structural i-beams w/ make-shift wood for support of q-deck on 1st & 3rd floors, various locations q-deck is bowing. upon research on dob records a

    May 9, 2024 · Penalty $2,530

    Resolve
  • Class - 2

    3301.13.8 inspection by the construction superintendent. observed multiple violating conditions on jobsite. i-beams w/ make-shift wood for support, window protection not provided 2 adjacent property, no control

    May 9, 2024 · Penalty $5,000

    Resolve
  • Class - 2

    Slipping & tripping hazards. observed pedestrian sidewalk at exposure 1 exterior of jobsite inadequately maintained as per code (bc3303.4.1.1). the said sidewalk is damaged & in poor conditions with multiple c

    Dec 11, 2023

    Resolve
  • Class - 1

    Fail to comply with fdny regulations and have fire safety measures, observed fire-extinguishers discharged, not maintained, no other fire safety measures in place. stop all structural work and steel erections.

    Jul 24, 2023 · Penalty $2,500

    Resolve
  • Class - 1

    Structural steel c-channel & make-shift plate connect l channed between w8 & w18 i-beams not per plans w/ bowed q-deck pour concrete on 2 floor. sketch drawings provided w/out approved plans and/or pe shop draw

    Jul 24, 2023 · Penalty $2,500

    Resolve
  • Class - 1

    Partial make-shift plywood without drawings extended 4 feet over adjacent property expo 2, while the backyard was being used by a neighbor. observed splashes of concrete on the awning and neighbor in the backya

    Jul 24, 2023 · Penalty $2,500

    Resolve
  • Class - 1

    Electrical wire connection to feed adjacent property house no protected blocking by cmu block at 2 floor height and meters at 1 floor level with exposed rebars without protection. stop all work above 1st floor

    Jul 24, 2023 · Penalty $2,500

    Resolve
  • Class - 1

    Observed sidewalk shed at exposure 1& 4 exterior of jobsite. request for approved designed drawings, daily inspection, and letter of completion from superintendent on site, none were be provided. observed larg

    Jul 24, 2023 · Penalty $2,500

    Resolve
  • Class - 2

    Observed multiple violating conditions on active jobsite not corrected and logged into superintendent daily log books. electrical wire connection to feed adjacent property house not protected, failed to comply

    Jul 24, 2023 · Penalty $5,000

    Resolve
  • Class - 2

    Comments: at the time of my inspection of an active 6 story nb by i observed at the first floor work deck multiple unprotected rebars 2 1/2 feet to 3' high. no rebar caps as per manufacturer specification bc 33

    Jul 5, 2023

    Resolve
  • Class - 2

    Comments: at the time of my inspection of an active 6 story nb; at the first floor working deck superstructure. i observe at the first floor working deck an opening approximately 10' x 10' and 8 to 9' drop to t

    Jul 5, 2023

    Resolve
  • Class - 2

    At time of inspection, i observed construction fence leaning outward, construction materials and yodocks barriers stored on the public sidewalk. these conditions reduce the pedestrian walkway from 5ft to about

    Dec 1, 2022

    Resolve
  • Class - 1

    Work doesnt conform to approved const docs as noted:atoi@active const site for proposed 6styb in excavation phase,observed:(a)underpinning depth 2'.soe401.00 req 36"(3').(b)underpinning ht 55".soe401.00 req 5'4

    Oct 18, 2022

    Resolve
  • Class - 2

    Jobsite fence not constructed or maintained pursuant to subsection.noted:fence viewing panel not provided at the front or at exposure#1 or exposure#4(2)part of fence missing at exposure#1 and(3)exposure#4 not p

    Jun 30, 2021

    Resolve
  • Class - 2

    There is a dead storage of a vehicle at rear of premises there is an astro van forest green chevrolet w/ the word jesus is the lord inscribed on rear doors the vehicle does not have license plates or registrati

    Jun 6, 2011 · Penalty $400

    Resolve
  • Class - 2

    Bldg dept records do not indicate off street parking and/or accessory parking per 1 or more vehicles at rear of premises now there is an astro van chevrolet parked at rear of premises rem; discontinue illegal u

    Jun 6, 2011

    Resolve
  • Class - 1

    At exp4 at rear yard appx 15' of the concrete masonry unit curtain wall has been torn down causing damage to the rest of the wall the wall is out of plumb cracked spalling cmu and in danger of collapse

    Jun 6, 2011 · Penalty $1,000

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D1)
Year built
2023
Floors
6
Residential units
12
Building area
9,575 ft²
Lot area
2,500 ft²
Zoning
R7-2
Community board
201
Council district
17
Block / lot
2405 / 18
Assessed value
$251,550
Landmark / historic district
No

Questions about 382 East 159 Street

Who owns 382 East 159 Street?

The owner of record in NYC Department of City Planning PLUTO data is 382 E 159th Street LLC.

Does 382 East 159 Street have violations?

NYC HPD has no housing violations on record for this property.

Is 382 East 159 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 382 East 159 Street built?

City records list 2023 as the year it was built.

How many apartments are in 382 East 159 Street?

It has 12 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.