roofy

1871 Amsterdam Avenue

Manhattan, NY 10031BBL 1-02067-0064Map

Owner of record: 1867-1871 Amsterdam Avenue LLC

1871 Amsterdam Avenue is an elevator apartment building built in 2025 in Manhattan, 10031. It has 20 residential units across 7 floors. The owner of record is 1867-1871 Amsterdam Avenue LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
6
ECB violations
16
HPD complaints
1

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 6

  • Construction other optional

    Unsafe excavation with depth greater than 5' on multiple exposures, no slopes, bench or lateral support. danger to life & property remedy: backfill to grade for all affected exposures under full time pe to begin by 2/14/25. submit verification to construction safety engineering

    Feb 14, 2025

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued-failure to file 2023 external low pressure inspection

    Sep 23, 2024

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 26, 2002

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 7, 2000

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 10, 1997

    Dob violation - dismissed

ECB violations · 16

  • Class - 2

    Observed temporary construction fence maintained with expired-(3-12-26) permit posted at site entrance. fence remains in place occupying public sidewalk frontage without valid permit renewal or updated authoriz

    May 20, 2026

    Resolve
  • Class - 2

    Site was observed to have a sidewalk shed erected and in place along exposure 1 of site. upon review of department records, the permit for sws was found to be expired on 3/6/26. maintain/display an active permi

    Mar 26, 2026 · Penalty $3,125

    Resolve
  • Class - 2

    Site was observed to have a construction fence erected and in place along exposure 1 of site. upon review of department records, the permit for the construction fence was found to be expired on 3/12/26. maintai

    Mar 26, 2026

    Resolve
  • Class - 1

    Supported scaffold stair tower installed in a non-conforming manner. stair tower was not fully erected, requiring access by stepping across cross braces between levels.cross bracing was missing at lower levels,

    Jan 29, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    Failed to maintain supported scaffold in a clean and safe condition. snow, ice, and debris were observed accumulating on scaffold platforms and walking surfaces, creating slip and trip hazards for workers. scaf

    Jan 29, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    At time of inspection, a 20-yard waste container located on exp 1 was observed to be fully loaded and left uncovered at the end of the workday, potentially causing flying debris into the public. comply with cod

    Dec 23, 2025 · Penalty $2,500

    Resolve
  • Class - 2

    Upon inspection i observed a sidewalk shed installed at expos 1 & 4 contrary to approved drawings. approx. 11ft elevation was not detailed in the drawings. missing horizontal & cross bracing at expos 1&4. shed

    Nov 20, 2025

    Resolve
  • Class - 2

    Upon inspection i observed a sidewalk shed installed at expos 1&4 contrary to codes 3307.6.4.9 visually obstructed street signs at expos 1 & obstructed hydrant at expos 4. 3307.6.4.10 mudsills not secured at ex

    Nov 20, 2025 · Penalty $5,000

    Resolve
  • Class - 2

    Bc3314.4.8_during my inspection of an active jobsite for a 7-story new building (nb), i observed the supported scaffold at exposures #1. the scaffold had loose planks , missing safety pins, and was not maintain

    Oct 21, 2025 · Penalty $2,500

    Resolve
  • Class - 1

    During my inspection of the active job site for a 7-story building, i observed that no guardrails were installed on the stairs. additionally, loose netting and mid-rails were missing from several areas througho

    Oct 21, 2025 · Penalty $5,000

    Resolve
Show 6 more ↓
  • Class - 2

    Bc 3303.7.2_at time of my inspection of a 7 story nb/active jobsite, i observed inadequate fire extinguishers (missing safety pins, old/damage, missing inspection tags and all missing monthly inspection.comply

    Oct 21, 2025 · Penalty $2,500

    Resolve
  • Class - 2

    During my inspection of an active 7-story nb job site, i observed that exit signs, and no smoking signs were missing. the absence of these signs is detrimental to maintaining a safe working environment.comply w

    Oct 21, 2025 · Penalty $1,250

    Resolve
  • Class - 2

    New 7 story residential building. observed: storage zone in the streetwith material & heavy machinery not protected from vehicular traffic & accessible to public contrary to building code 3301.1 -3301.2- 3301.

    Sep 7, 2025

    Resolve
  • Class - 2

    Bc 3303.14.2-standing water/protection of foundation-at the time of my inspection observed standing water at cellar/basement level aprox 10" to 12" deep-with area of aprox 25' by 25'-accumulation of water shall

    Jul 22, 2025 · Penalty $2,530

    Resolve
  • Class - 1

    Failure to provide protection of sides of excavations in contrary with code 3304.4. observed excavation on north/east areas approximately 12 to 13 feet deep no such means of supporting excavations shall be inst

    Feb 13, 2025 · Penalty $5,030

    Resolve
  • Non-hazardous

    B4a/16/32a/50/50a/50b/50c/50d/.50-safety valve not mounted upright.50a-missing blow down piping on backflow & missing check valve after backflow.50b-missing clean-out at base of chimney.50c-ceiling around

    Jun 22, 2007 · Penalty $180

    Resolve

Complaints

  • Heating

    Heat related

    Jan 26, 2007 · Apt BLDG

    Close

Sales history

DatePriceTypeUnits
Feb 17, 2026Non-market transferRentals - elevator apartments21
Jan 5, 2026Non-market transferCommercial vacant land21

Building details

Building type
Elevator apartment building (D6)
Year built
2025
Floors
7
Residential units
20
Building area
20,290 ft²
Lot area
3,900 ft²
Zoning
R7A
Community board
109
Council district
7
Block / lot
2067 / 64
Assessed value
$375,750
Landmark / historic district
No

Questions about 1871 Amsterdam Avenue

Who owns 1871 Amsterdam Avenue?

The owner of record in NYC Department of City Planning PLUTO data is 1867-1871 Amsterdam Avenue LLC.

Does 1871 Amsterdam Avenue have violations?

NYC HPD has no housing violations on record for this property.

Is 1871 Amsterdam Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 1871 Amsterdam Avenue built?

City records list 2025 as the year it was built.

How many apartments are in 1871 Amsterdam Avenue?

It has 20 residential units and 21 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.