102 West 131 Street
Manhattan, NY 10027BBL 1-01915-0037Map
Owner of record: Newman, Juliet
102 West 131 Street is a two-family home built in 2017 in Manhattan, 10027. It has 2 residential units across 4 floors. The owner of record is Newman, Juliet. HPD has recorded 6 housing violations here, most recently on November 24, 2025. 5 of the 6 most recent violations are still open.
- HPD violations
- 6
- DOB violations
- 1
- ECB violations
- 16
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 6
- IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 24, 2025
Open — Info nov sent out - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Dec 3, 2024
Open — Info nov sent out - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 27, 2023
Open — Info nov sent out - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 16, 2022
Open — Info nov sent out - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Mar 18, 2022
Open — Info nov sent out - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 7, 2019
Closed — Violation dismissed
DOB building violations · 1
- Construction other optional
C-construction other optional
Jul 27, 2017
Vp*-violation unserved ecb- dismissed
ECB violations · 16
- Class - 1
Failure to institute/maintain safety equipment measures/temporary construction no guardrails.@ the time of inspection,the contractor had missing guardrails on all rear balconies,& the exposure #3 steps leading
Feb 21, 2018 · Penalty $1,200
Resolve - Class - 1
Work does not conform to approved construction documents &/approved drawings.@ the time of inspection,the contractor installed interior walls,from the cellar to the 2nd,3rd & 4th fl,not according to plan.in add
Feb 21, 2018 · Penalty $250
Resolve - Class - 1
Failure to safeguard all persons & property affected by construction operations: no fall protection. note: observed active 4 sty bldg,erected to the 3rd fl observed at exp#2 new cmu block recently installed wet
Nov 6, 2017
Resolve - Class - 1
Failure to maitnain/display on site documents required by chapt 33. note: observed 4 sty bldg erected to 3rd fl level. at exo#3 & 3rd fl observed material hoisting equipment set up to lift concrete material fro
Nov 6, 2017
Resolve - Class - 2
Sec. 3301.1.1 responsibility for safety: inadequate lighting. note: 4 sty bldg at the 3rd fl level. there is no temporary lighting on the 1st fl or cellar. (ft) is dark w/minimal daylight. gc neglected to provi
Nov 6, 2017 · Penalty $400
Resolve - Class - 1
Material storage.@ the time of my inspection of new 4 story building under construction.construction @ 3rd story level.i observed fl joists for the 3rd fl/2nd fl ceiling joists straps were not fastened.3rd fl w
Oct 19, 2017 · Penalty $2,400
Resolve - Class - 1
At time of inspection, answering above complaint, i observed failure to protect walkway/plaza in front of adjoining building. there is no prtection of falling debris and material into the front walkway at expo
Oct 3, 2017 · Penalty $400
Resolve - Class - 1
At time of inspection, answering complaint above, i observed at exp #4 rear roof has inadequate roof protection. no osha planks and 1" inch roam. also no protection for the skylights. rem: stop work at expo 4 a
Oct 3, 2017 · Penalty $400
Resolve - Class - 1
Bc3314.9.2.scaffold foundation.at the time of my inspection of new 4 story building under construction-construction at 2nd floor level i observed workers performing masonry operations along perimeter wall at ex
Sep 28, 2017 · Penalty $1,600
Resolve - Class - 1
No guardrails.at the time of my inspection of new 4 story building under construction-construction at 2nd floor level.i observed that the landing for the ladder leading up to 2nd floor was not enclosed and had
Sep 28, 2017 · Penalty $1,200
Resolve
Show 6 more ↓
- Class - 1
Bc3314.8.1.no guardrails scaffold.at the time of my inspection of new 4 story building under construction.construction at 2nd floor level i observed worker performing masonry work on a scaffold level i observed
Sep 28, 2017 · Penalty $1,600
Resolve - Class - 2
Failure to safeguard.at the time on my inspection of new 4 story building under construction-construction at 2nd flooe level,i observed openings in the floor at the 1st and 2nd floors along expsoures 1&3.this c
Sep 28, 2017
Resolve - Class - 1
3303.4.1 sidewalk.at the time of my inspection of new 4 story buildingunder construction at first floor level,i observed cracked & broken sidwalk alon construction fence at exp 1.cracked sidewalk causes an im
Aug 30, 2017 · Penalty $1,630
Resolve - Class - 1
3303.4.7 material storage.at the time of my inspection of new 4 story building under construction at first floor level i observed pails of cinderblocks stacked higher than 3' tall store along sidewalk open to t
Aug 30, 2017 · Penalty $1,630
Resolve - Class - 1
Failure to safeguard public and property. at time of inspection observed sidewalk shed support posts at exp4 were interfering with the safe egress of adjoining property, post where set in a manner that was too
Jul 27, 2017 · Penalty $4,800
Resolve - Class - 2
Job site fence not constructed or maintained pursuant to subsection. note: 4 sty bldg @ foundation phase-approx 10feet below grade. construction fence at exp#1 no per code. plywood affixed to existing chain lin
Jul 6, 2017
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Two-family home (B2)
- Year built
- 2017
- Floors
- 4
- Residential units
- 2
- Building area
- 4,220 ft²
- Lot area
- 1,665 ft²
- Zoning
- R7-2
- Community board
- 110
- Council district
- 9
- Block / lot
- 1915 / 37
- Assessed value
- $174,120
- Landmark / historic district
- No
HPD registration #611307, last renewed Dec 30, 2020.
Questions about 102 West 131 Street
Who owns 102 West 131 Street?
The owner of record in NYC Department of City Planning PLUTO data is Newman, Juliet.
Does 102 West 131 Street have violations?
Yes. NYC HPD has recorded 6 housing violations at this property.
Is 102 West 131 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 102 West 131 Street built?
City records list 2017 as the year it was built.
How many apartments are in 102 West 131 Street?
It has 2 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.