Violations at 227 East 102 Street
Manhattan, NY 10029 · BBL 1-01652-0016 · Back to the property
HPD housing violations
No HPD violations on record
DOB building violations
15 DOB violations, newest first.
- Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 26, 2002
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 26, 2002
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed - Construction other optional
C-construction other optional
Jan 11, 1998
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 1, 1994
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 1, 1994
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 1, 1994
Dob violation - dismissed
ECB violations
The newest 50 of 157 ECB violations. The city keeps the complete history.
- Class - 2
Failure to maintain building in code-compliant manner.noted broken/cracked window panel at classroom#215,#209,above classroom#218 door,at smoke door between exit#5 and stair f at first floor.rem:repair and/or r
Jul 22, 2026 · Penalty $1,250
Active - Class - 2
Failure to maintain building in code-compliant manner.noted loose/cracked step at exterior at front of main entrance,exit#9.rem:repair and/or replace.
Jul 22, 2026 · Penalty $1,250
Active - Class - 2
Failure to maintain building in code-compliant manner.noted broken/disconnected electrical conduit for exterior lights above exit door#10.rem:repair and/or replace.
Jul 22, 2026 · Penalty $1,250
Active - Class - 2
Reissued ecb#35654993y failure to maintain building in code-compliant manner.noted the old coal chute has water penetration through grofes.rem:repair and/or replace.
Jul 22, 2026 · Penalty $3,125
Active - Class - 2
Reissued ecb#35654989l failure to maintain building in code-compliant manner.noted at the basement level water lines leaking and broken value at boiler tank causing water puddle in the basement.rem:repair and/o
Jul 22, 2026 · Penalty $3,125
Active - Class - 2
Reissued ecb#35724665x failure to maintain building in code-compliant manner.illumination for exits,exit discharges and public corridors perbc 1006.1;27-381.noted several emergency lights not working throughout
Jul 22, 2026 · Penalty $3,125
Active - Class - 2
Reissued ecb#35724661z failure to maintain building in code-compliant manner.noted at basement level oil tank room deteriorating,peeling andplastering ceiling exposing rusty re-bars.rem:repair and/or replace.
Jul 22, 2026 · Penalty $3,125
Active - Class - 2
Reissued ecb#35724662k failure to maintain building in code-compliant manner.noted spalling plaster at 5th floor ceilings at classrooms at several locations.rem:repair and/or replace.
Jul 22, 2026 · Penalty $3,125
Active - Class - 2
Reissued ecb#35724663m failure to maintain building in code-compliant manner.noted the coping stone at roof level by bulkhead,stair i cracked and spalling at several areas.flushing also needs repair.rem:repair
Jul 22, 2026 · Penalty $3,125
Active - Class - 2
Reissued ecb#35724664y failure to maintain building in code-compliant manner.noted all roof lights designed to light exterior perimeter of school not working.rem:repair and/or replace.
Jul 22, 2026 · Penalty $3,125
Active - Class - 2
Failure to maintain building in code-compliant manner. noted: there were several emergency lights scattered throughout the building, gym andauditorium that were not operational when tested. remedy: repair/repla
Sep 18, 2025 · Penalty $3,125
Active - Class - 2
Re-issue #35676334h. failure to maintain building in code-compliant manner. noted: the roof lights designed to light the exterior perimeter are not working. remedy: repair/replace.
Sep 18, 2025 · Penalty $3,125
Active - Class - 2
Re-issue #35676434p. failure to maintain building in code-compliant manner. noted: the coping stone at roof level by bulkhead stair 1 is cracked, and spalling in several areas. flashing also needs repair. remed
Sep 18, 2025 · Penalty $3,125
Active - Class - 2
Re-issue #35676437k. failure to maintain building in code-compliant manenr. noted: the roof is leaking and causing damage to the ceilings and rooms below. remedy: repair/replace.
Sep 18, 2025 · Penalty $3,125
Active - Class - 2
Re-issue #35682902h. failure to maintain building in code-compliant manner. noted: at basement level, oil tank room, the ceiling is deteriorating, peeling, flaking. re-bar can be seen. remedy: repair/replace.
Sep 18, 2025 · Penalty $3,125
Active - Class - 2
Reissue#35654992m failure to maintain building in code compliant manner.basement level oil tank room ceilings spalling concrete can see roomrem:repair and/or replace.
Aug 12, 2024 · Penalty $1,562
Active - Class - 2
Exit door not self-closing. noted: the exterior doors at exit 1,2,4,5,7,8, and main entrance to the building are not working properly. remedy: repair/replace door.
Jul 12, 2023 · Penalty $625
Resolve - Class - 2
Failure to maintain building in code-compliant manner. noted: at 5th floor stair k, l, 4th floor slop sink room by stair e, outside auditorium stage left door room 138a, and smoke by exit 4, the doors are not w
Jul 12, 2023 · Penalty $625
Resolve - Class - 2
Reissue #35654993y noted: at roof level, the roof is leaking in various areas and is causing damage to the classrooms and corridors below. remedy: repair and/or replace.
Jul 12, 2023 · Penalty $1,562
Active - Class - 2
Reissue #35654990z noted: at roof level, the bulkhead of stair e, f and k, l have leaks and is causing damage to the interior walls and ceiling in various areas througout. remedy: repair and/or replace.
Jul 12, 2023 · Penalty $1,562
Resolve - Class - 2
Reissue #35654989l noted: at basement level, the water line that supply the tank for boilers have leaks and a faulty valve, causing water puddles in various areas throughout. remedy: repair and/or replace.
Jul 12, 2023 · Penalty $1,562
Resolve - Class - 2
Reissue #35654988j noted: at roof level, the coping stone by bulkhead stair i has cracks, spalling and missing masonry in various areas. also, there is flashing missing from the parapet wall in several places.
Jul 12, 2023 · Penalty $1,562
Active - Class - 2
Reissue #35654985y noted: at roof level, the exterior lights installed around the perimeter are inoperative. also, em #18 by security desk, #19 at main entrance to the building, #21 by room 153, 1st floor #24 a
Jul 12, 2023 · Penalty $1,562
Active - Class - 2
Reissue #35654994x noted: observed gas powered snowblowers being stored at basement level. remedy: repair and/or replace.
Jul 12, 2023 · Penalty $1,562
Resolve - Class - 2
Reissue#35094575z.failure to maintain building in code compliant manner.note at basement levcel in oil tank room,the ceiling is spalling concrete exposing the rebar.remedy:repair and/or replace.
May 27, 2022 · Penalty $1,562
Active - Class - 2
28-301.1 failure to provide natural or mechanical ventilation to occupied spaces per bc401.2 note at basement level storage of gas equipmentie snowblowers.remedy:comply with violation.remove gas equipment.
May 26, 2022 · Penalty $1,250
Resolve - Class - 2
Failure to maintain building in code compliant manner.note at roof level,the roof leaks in various areas causing damage to ceilings below.remedy:repair and/or replace.
May 26, 2022 · Penalty $625
Active - Class - 2
Reissue#35487088z.failure to maintain building in code compliant manner.failure to maintain building in code compliant manner.note at basement level the old coal chute as water penetrating through grates with w
May 26, 2022 · Penalty $1,562
Active - Class - 2
Reissue#35487082h.remedy:failure to maintain building in code compliant manner.note at roof level the bulkheads at stairway e,f and k,l haveleaks with water penetrating down the walls causing the plaster to spa
May 26, 2022 · Penalty $1,562
Resolve - Class - 2
Reissued #35487086p failure to maintain building in code compliant manner.note:at basement level water lines lead to water tank for boiler have leaks & broken valve causing water to puddle in basement.remedy:re
May 26, 2022 · Penalty $1,562
Active - Class - 2
Reissued #35584117n failure to maintain building in code compliant manner.note:at roof level capstone on parapet wall crumbling & spalling also flashing is coming off wall.remedy:repair and/or replace
May 26, 2022 · Penalty $1,562
Active - Class - 2
Reissued #35584114h failure to maintain building walls or appurtenances.note:at basement level in fuel tank room spalling concrete at ceiling & water penetrationg through walls.remedy:maintain building exterior
May 26, 2022 · Penalty $3,125
Resolve - Class - 2
Reissued #35584115j failure to maintain building in code compliant manner lack of emergency lighting for exits exit discharges & public corridors per bc 1006.1;27-542 note:at auditorium emergency lights not wor
May 26, 2022 · Penalty $3,125
Resolve - Class - 2
Reissued #35584116l failure to maintain building in code compliant manner.note:at roof level exterior lights for school property not working.remedy:repair and/or replace
May 26, 2022 · Penalty $1,562
Active - Class - 2
Re issued #35433817x.failure to maintain building in code compliant manner.capstone at roof level crumbling and spalling at bulkhead #1 flashing coming off wall.remedy:comply with code.
Jul 13, 2021 · Penalty $1,562
Active - Class - 2
Re issued #35433818h.failure to maintain building in code compliant manner.noted:roof level exterior lights not working.remedy:comply with code.
Jul 13, 2021 · Penalty $1,562
Active - Class - 2
Re issue #35216736n. failure to maintain bldg in code compliant manner.lack of emergency lights for exits.discharges and public corridor per bc 1006.1;27-542.noted:auditorium emergency lights not working.remedy
Jul 13, 2021 · Penalty $3,125
Resolve - Class - 2
Re issued #35433814k.failure to maintain building wall(s) and appurtenances.noted:basement fule tank room spalling concrete and water penetration.remedy:comply with code.
Jul 13, 2021 · Penalty $3,125
Resolve - Class - 2
Reissue#35094577m failure to maintain bldg in code compliant manner atbldg in code compliant manner at bldg exterior walls or appurtenances.water penetration entering basement at old coal chute,grates,foundatio
May 28, 2020 · Penalty $3,125
Resolve - Class - 2
Reissue#35094577m failure to maintain bldg in code compliant manner atbldg exterior walls or appurtenances. water penetration entering basement at old coal chute,grates,foundation walls. remedy: maintain bldg
May 28, 2020 · Penalty $1,562
Active - Class - 2
Reissue#35331787r failure to maintain bldg walls or appurtenances. note at fuel tank room columns have masonry spalling & cracking & rain water penetrating & pudding on floors. remedy: maintain bldg exterior wa
May 28, 2020 · Penalty $3,125
Resolve - Class - 2
Reissue#35433820r failure to maintain bldg in code compliant manner. note at basement level water lines that lead to tanks for boiler have broken valves that leak forming puddles on the floor. remedy: repair/re
May 28, 2020 · Penalty $1,562
Active - Class - 2
Reissue#35433812r failure to maintain bldg in code compliant manner. note lack of emergency lights for exits,exit discharges & public corridors. per bc 1006.12;27-542. at the auditorium exit lighting was not
May 28, 2020 · Penalty $3,125
Resolve - Class - 2
Reissue#35433813z failure to maintain bldg in code compliant manner. note: at basement level in boiler room & throughout basement the masonry is spsalling cracked or missing from the ceiling in areas all over.
May 28, 2020 · Penalty $1,562
Resolve - Class - 2
Reissue#35433815m failure to maintain bldg in code compliant manner. note: at basement level in fuel tank room. the concrete on walls & ceiling in various places is spalling,exposing rebar w/water pentrations.
May 28, 2020 · Penalty $1,562
Active - Class - 2
Reissue#35433816y failure to maintain bldg in code compliant manner. note: a roof level bulkhead at stairs e&f & k&l have leaks & water penetrations down walls to 3rd fl w/plaster spalling & when it rains the
May 28, 2020 · Penalty $1,562
Resolve - Class - 2
Reissue#35433817x failure to maintain bldg in code compliant manner. @roof level parapet wall cap stone by elevator machine room is spallingcrumbling & falling on skylight below. also flashing is falling off of
May 28, 2020 · Penalty $1,562
Active - Class - 2
Reissue#35433818h failure to maintain bldg in code compliant manner. note: at roof level the exterior flood lights are not working. remedy: repair & replace.
May 28, 2020 · Penalty $1,562
Active - Class - 2
Reissue#35433819j exit dor not self closing. note: exit#1 by kitchen,exit#11 on 1st fl & 5th fl. corridor door nrear stairs k & l not self closing. remedy: repair/replace door.
May 28, 2020 · Penalty $1,562
Resolve - Class - 2
Failure to maintain building in code compliant manner.note: at basement level in boiler room water tank leaks leaving paddling water . remedy: repair and replace.
Jun 21, 2019
Active