roofy

33 West 46 Street

Manhattan, NY 10036BBL 1-01262-0021Map

Owner of record: Rss Msbam2015-C20-NY 3w4, LLC

33 West 46 Street is an office building built in 1915 in Manhattan, 10036. The owner of record is Rss Msbam2015-C20-NY 3w4, LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
49
ECB violations
38
HPD complaints
4

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 49

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 4, 2023

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 4, 2023

    Dob violation - active
  • Construction other optional

    Borough commissiner stop work order application #122480537 due to site safety manager withdrawal

    Mar 31, 2023

    Dob violation - active
  • Construction other optional

    Borough commissiner stop work order application #122480537 due to site safety manager withdrawal

    Mar 31, 2023

    Dob violation - active
  • Hazardous condition (facade) facade required

    Cycle 9c unsafe report filed

    Jan 9, 2023

    Dob violation - active
  • Construction other optional

    Ftm building exterior walls/facade roof area defected at parapet wall exp 1 various factured terra cotta. exp 4 spalling and damaged windows remedy: maintain building exterior walls facade and appurtenances repair defect as per 1 rcny 103.04

    Nov 8, 2021

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 1, 2021

    Dob violation - resolved
  • Failure to post energy grade/score none

    Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3

    Apr 29, 2021

    Dob violation - dismissed
  • Construction other optional

    The department of buildings orders that all work under application #122480537 stop due to site safety managers withdrawal.

    Dec 4, 2020

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 11, 2020

    Dob violation - resolved
Show 39 more ↓
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 11, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 24, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 24, 2019

    Dob violation - resolved
  • Sprinkler none

    Failed to file final sprinkler report by july 1, 2019

    Sep 3, 2019

    Dob violation - active
  • Plumbing none

    The dob orders that you stop all plumbing work under job #122860412 due to the permit holder withdrawal from the project

    Sep 27, 2018

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 9, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst

    Nov 14, 2016

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst

    Nov 14, 2016

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 21, 2016

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 7, 2014

    Dob violation - resolved
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst

    May 30, 2014

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst

    May 30, 2014

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2012 inspection report

    May 15, 2014

    Dob violation - dismissed
  • No report and / or late filing (facade) facade required

    Failed to file fisp cycle 7c technical report by 02/21/2013

    Dec 31, 2013

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 12, 2012

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 12, 2012

    Dob violation - resolved
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2010 inspection/test

    Dec 13, 2011

    Dob violation - dismissed
  • Construction other optional

    C-construction other optional

    Jun 14, 2011

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Vcat1-elevator annual inspection / test elevatorrequired

    Oct 8, 2010

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 20, 2010

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 20, 2010

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 7, 2008

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 7, 2008

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 7, 2008

    Dob violation - active
  • Facade facade optional

    Ll1198-local law 11/98 - facade facade optional

    Nov 30, 2007

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 7, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 7, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 13, 2005

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 13, 2005

    Dob violation - resolved
  • Elevator elevatorrequired

    1p6952

    Feb 25, 2000

    Dob violation - resolved
  • Elevator elevatorrequired

    1p6953

    Feb 25, 2000

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - dismissed
  • Elevator elevatorrequired

    1p6952

    Jan 20, 1999

    Dob violation - resolved
  • Elevator elevatorrequired

    1p6953

    Jan 20, 1999

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 18, 1993

    Dob violation - dismissed
  • Boiler boiler optional

    48

    Jul 31, 1990

    Vp*-violation unserved ecb- dismissed
  • Boiler boiler optional

    36

    Nov 14, 1989

    Dob violation - dismissed

ECB violations · 38

  • Class - 2

    Failure to file acceptable amended cycle 9c report indicating correction of unsafe conditions described in initial facades report required by 28-302.5 for control #904126. remedy: file acceptable report.

    Apr 20, 2026 · Penalty $6,250

    Active
  • Class - 2

    A. c. 27-929.1, failure to complete the installation of a full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional in an office building 100 feet or mor

    Jun 17, 2024 · Penalty $10,000

    Active
  • Class - 2

    A.c.27-929.1,failure to complete the installation of a full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional in an office building 100' or more in he

    Feb 28, 2023 · Penalty $6,250

    Active
  • Class - 1

    Failure to maintain building in code complaint manner i observed on the 10 and 11 floor no permanent or temporary standpipe in place . in cellar gas line going threw the fire pump room, repair and/replace

    Sep 2, 2022 · Penalty $6,250

    Active
  • Class - 2

    Sidewalk shed at exposure 1 does not expended along with adjacent building at exposure 2, in contrary with code3307.6.3 area to be protected, creating hazardous to pedestrians, may causing injures from unsafe f

    Jun 3, 2022 · Penalty $10,000

    Active
  • Class - 1

    Failure to provide adequate required safety measures such as sidewalk shed,netting,fence,etc,where required to secure public safety.note:qewi filed unsafe filing#904126-9c-001 issued on 04/22/2022 and as of tod

    May 17, 2022 · Penalty $25,000

    Active
  • Class - 2

    27-929.1 failure to complete installation of full system of automatic sprinklers and file final sprinkler report prepared by registered design professional in office building 100 feet or more in height in exist

    Nov 1, 2021 · Penalty $3,125

    Active
  • Class - 2

    Pedestrian protection does not meet code specification-failure to maintain sidewalk shed - missing parapet sections.noted:at time of inspection of 10 story alteration observed sidewalk shed in place at exp #1

    Aug 30, 2021 · Penalty $2,400

    Resolve
  • Class - 2

    Temporary equipment onsite expired permit(sidewalk shed)at time of my inspection on an alt1 10 story jobsite,observed that the permit for the sidewalk shed had expired 3/5/2021.for public safety code stipulates

    May 12, 2021

    Resolve
  • Class - 2

    Failure to maintain exterior building facade and appurtenances.note:observed at 1)exposure#1-south (d.s. 46th st)cracked terra cotta at parapet 8th and 9th floors.2).exposure#2-west cracked terra cotta at parap

    Feb 5, 2021 · Penalty $1,250

    Active
Show 28 more ↓
  • Class - 2

    Pedestrian protection does not meet code specifications.at time of my inspection observed sidewalk shed in place-10 sty building.observed the caps for the bolts was missing and the mudsill for the sidewalk shed

    Jun 18, 2020 · Penalty $5,000

    Resolve
  • Class - 1

    Bc330853-inadequate cable system.noted:active job site observed at 11th fl cable system at exp1 slacking with no netting and tied up to metal stud,and on roof level exp1 there was no zero cable in place inadequ

    Jun 2, 2020 · Penalty $6,250

    Resolve
  • Class - 1

    Work not conforming to approved drawings or const. documents.noted:active site observed horizontal netting installed at 9th floor missing top layer of nets contrary to approved site safety plan.stop all work 10

    Jun 2, 2020 · Penalty $625

    Resolve
  • Class - 1

    Bc 3301.2 failure to maintain institute safety measures.noted:active site,observed iron workers on 11th fl and roof working on balcony on exp 1 with harnesses on but no life line or proper anchorage fall arrest

    Jun 2, 2020 · Penalty $6,250

    Resolve
  • Class - 1

    Bc 3308.5.3 inadequate cable system.noted:active jobsite observed at 11th fl cable system at exp 1 slacking with me netting and tied up to metal stud and on roof level exp 1 there was no zero cable in place ina

    Jun 2, 2020 · Penalty $6,250

    Resolve
  • Class - 2

    Sec. 27-929.1 ac 27-929.1 failure to complete the installation of a full system of automatic sprinklers & file a final sprinkler report prepared by a registered design professional by 7/1/19,in an office bldg

    Mar 30, 2020 · Penalty $3,125

    Active
  • Class - 2

    Ac279291-failure to complete the installation of full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional by july 1,2019, in an office building 100 feet

    Nov 15, 2019 · Penalty $1,280

    Active
  • Class - 1

    Work does not conform to approved construction documents and/or amendments noted at time of my inspection of an alteration type -1 10 storie building i observed the bolts siupporting the horizontal netting was

    Jun 26, 2019

    Resolve
  • Class - 1

    Failure to have site safety manager or coordinator, @ time of insp observed 10 story alteration bldg of 9 story above, construction started some location on roof & roof protection of adjacent property. no site

    Mar 29, 2018

    Resolve
  • Class - 2

    Failure to submit acceptable 7th round report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control #704126. agg2 history of noncompliance on 3602358

    Mar 7, 2018 · Penalty $3,125

    Resolve
  • Class - 2

    Failure to comply with the commissioner's order contained in summons/violation #35244575j issued 05/12/17 and to file a certificate of correursuant to 28-201.1 and 1rcny 102-01. time of inspection it was observ

    Sep 1, 2017 · Penalty $800

    Resolve
  • Class - 2

    Failure to comply w/the comm's order contained in summons/vio#35244575j issued on 05/12/17 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. for blocking the fire exit door. remedy: comply w/comm's order

    Jul 18, 2017 · Penalty $2,000

    Resolve
  • Class - 1

    Failure to provide unobstructed exit passageway. @ time of insp it wasobserved that @ the 9th flr level rear fire exits was block w/ 4 inches pipe, the door was not able to open due to the pipes obstructing the

    May 12, 2017 · Penalty $3,000

    Resolve
  • Class - 1

    Failure to take & provide adequate safety measures where required to protect & secure public safety from unsafe facade as per 1rcny 103-04.no amended report files as of 2/21/07 south elev.exp#1-parapet-high dec

    Jun 28, 2016 · Penalty $2,400

    Resolve
  • Class - 2

    Failure to maintain exterior bldgs south elev.exp#1.verticle & horizontal joints are eroded joints east elev.exp#1 spalling brick verticle joints @chimneys-mortar eroded.north elev.exp#3-egress balconies-cracke

    Jun 28, 2016 · Penalty $500

    Resolve
  • Class - 2

    Fail to file an acceptable tech report in compliance w/code provisions:nov #36026850x periodic inspection of exterior walls & appurtenances as req by dob.rem:file required report to dob.

    Nov 23, 2015 · Penalty $2,000

    Resolve
  • Class - 2

    Failure to maintain exterior bldg wall. noted: at south elevation(exp#1)numerous locations through-out entire terra cotta facade: open & missing mortar joints;at corners individual terra cotta masonry units

    Sep 1, 2015 · Penalty $500

    Resolve
  • Class - 2

    Failure to file an acceptable cycle 7 technical report in compliance with code provisions: periodic inspection of exterior walls & appurtenances as required by article 28-302 & the dept of bldgs rules & regulat

    Dec 22, 2014 · Penalty $830

    Resolve
  • Class - 2

    60-q-07/44-h-11/60-q-07-provide light guards in motor room & replace bulbs where needed.44-h-10-hoist ropes below sheave line loss diameter @ 8th, 6th-4th flrs

    Apr 1, 2011

    Resolve
  • Non-hazardous

    39h08 37m07 35m07 36m07 39-regroove traction sheave 37-provide covers controllers 35-provide fire extingusor 35-provide sign m/r door

    May 30, 2000

    Resolve
  • Non-hazardous

    730 #73 clen down entire shaftway

    Mar 15, 1999

    Resolve
  • Non-hazardous

    73o2-clean down entire shaftway.

    Mar 15, 1999

    Resolve
  • Non-hazardous

    36

    Nov 25, 1997 · Penalty $350

    Resolve
  • Non-hazardous

    Failure to provide adequate emergency power exit lights in corridors and tenant areas throughtou building. failure to provide exit&directional signs in tenant areas. failure to provide emergency power to exit a

    Mar 12, 1992 · Penalty $1,200

    Resolve
  • Unknown

    Elevator landing sign defective (i.e. not durable) floor numbering signs defective. remedy:install signs as per code ll16/84.

    Mar 12, 1992

    Resolve
  • Non-hazardous

    Boiler not registered.

    Jan 24, 1990 · Penalty $250

    Resolve
  • Non-hazardous

    Name plate on boiler is missing.manufacturers data sheet to be obtain-ed and produced to the bldg dept records.

    Feb 24, 1989 · Penalty $75

    Resolve
  • Non-hazardous

    Failure to file annual boiler report with this department for boiler 67954-01 remedy file report or have an inspection performed by this deapartement

    Jan 3, 1989

    Resolve

Complaints

  • Flooring/stairs

    Floor

    Dec 16, 2014 · Apt 1B

    Close
  • Door/window

    Door frame

    Dec 16, 2014 · Apt 1B

    Close
  • Paint/plaster

    Wall

    Dec 16, 2014 · Apt 1B

    Close
  • Paint/plaster

    Wall

    Dec 16, 2014 · Apt 1B

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Office building (O6)
Year built
1915
Floors
11
Residential units
—
Building area
34,553 ft²
Lot area
4,141 ft²
Zoning
C6-4.5
Community board
105
Council district
4
Block / lot
1262 / 21
Assessed value
$5,249,250
Landmark / historic district
No

Questions about 33 West 46 Street

Who owns 33 West 46 Street?

The owner of record in NYC Department of City Planning PLUTO data is Rss Msbam2015-C20-NY 3w4, LLC.

Does 33 West 46 Street have violations?

NYC HPD has no housing violations on record for this property.

Is 33 West 46 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 33 West 46 Street built?

City records list 1915 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.