337 Lexington Avenue
Manhattan, NY 10016BBL 1-00895-0027Map
Owner of record: Ak Properties Group
337 Lexington Avenue is a mixed residential and retail building built in 1920 in Manhattan, 10016. It has 3 residential units across 4 floors. The owner of record is Ak Properties Group. HPD has recorded 37 housing violations here, most recently on April 29, 2026. 1 of the 37 most recent violations are still open.
- HPD violations
- 37
- DOB violations
- 5
- ECB violations
- 4
- HPD complaints
- 14
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 37
- ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 29, 2026
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Jun 4, 2025
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Mar 15, 2023
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Feb 15, 2022
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 1, 2021
Closed — Violation dismissed - BHazardous
Arrange and make self-closing the doors .. in the entrance located at apt 4, 4th story, 1st apartment from east at south
Jul 20, 2018 · Apt 4
Closed — Violation closed - BHazardous
Repair or replace the carbon monoxide detecting device(s). missing located at apt 4, 4th story, 1st apartment from east at south
Jul 20, 2018 · Apt 4
Closed — Violation closed - BHazardous
Repair or replace the smoke detector missing located at apt 4, 4th story, 1st apartment from east at south
Jul 20, 2018 · Apt 4
Closed — Violation closed - ANon-hazardous
Paint or post a sign indicating floors at all stories at public hall
Jul 13, 2018
Closed — Violation dismissed - CImmediately hazardous
Fire escape defective. properly secure using nuts and bolts the top return rail to the front rail roof balcony at rear fire escape
Jul 13, 2018
Closed — Violation dismissed
Show 27 more ↓
- CImmediately hazardous
Remove the illegal fastening self locking panic bar installed on roof door
Jul 13, 2018
Closed — Violation dismissed - BHazardous
Properly repair with similar material the broken or defective fire retardant material at ceiling at cellar
Jul 13, 2018
Closed — Violation dismissed - BHazardous
Properly repair and abate unsafe electric wiring condition consisting of exposed wires at ceiling at cellar
Jul 13, 2018
Closed — Violation closed - BHazardous
Provide adequate lighting at or near the outside of the front entranceway of the building and keep same burning from sunset every day to sunrise on the day following minimum of 100 watts as required(light fixture(s) present). at front areaway
Sep 5, 2017
Closed — Violation closed - BHazardous
Abate the nuisance consisting of mice in the entire apartment located at apt 3, 3rd story, 1st apartment from east at south
Apr 9, 2013 · Apt 3
Closed — Violation closed - BHazardous
Abate the nuisance consisting of roaches in the entire apartment located at apt 3, 3rd story, 1st apartment from east at south
Apr 9, 2013 · Apt 3
Closed — Violation closed - BHazardous
Provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules. in the entire apartment located at apt 3, 3rd story, 1st apartment from east at south
Apr 9, 2013 · Apt 3
Closed — Violation closed - BHazardous
Repair or replace the smoke detector missing in the entire apartment located at apt 3, 3rd story, 1st apartment from east at south
Apr 9, 2013 · Apt 3
Closed — Violation closed - ANon-hazardous
D26-10.01 adm code refit bulkhead door at stairs to roof.
Aug 29, 1985
Closed — Violation closed - BHazardous
D26-19.07 adm code provide adequate lighting at or near the outside of the front entranceway of the building and keep same burning from sunset every day to sunrise on the day following 50 watts incandescent minimum required.
Aug 29, 1985
Closed — Violation closed - ANon-hazardous
D26-19.07 adm code provide adequate lighting at or near the outside of the front entranceway of the building and keep same burning from sunset every day to sunrise on the day following entrance to bldg.
Jun 20, 1979
Closed — Violation closed - ANon-hazardous
D26-10.01 adm code replace with new the missing section of smoke stack 4th sty to roof rear south.
Jun 20, 1979
Closed — Violation closed - BHazardous
D26-10.01, 10.05 adm code remove all encumbrances consisting of pails lumber etc 4th sty public hall to roof.
Jun 20, 1979
Closed — Violation closed - ANon-hazardous
D26-10.01 adm code properly repair the broken or defective wood floor basement sty at rear.
Jun 20, 1979
Closed — Violation closed - ANon-hazardous
D26-12.01 adm code paint with light colored paint to the satisfaction of this department walls ceilings & soffits public halls all stys.
Jun 20, 1979
Closed — Violation closed - BHazardous
D26-10.01, 10.05 adm code remove all encumbrances consisting of signs disused radiator wood 5sty public hall.
Jun 20, 1979
Closed — Violation closed - BHazardous
§ 300, 301, 302, m/d law file plans and obtain a certificate of occupancy to legalize the following alteration or restore premises to prior legal condition 1st sty converted to dry cleaning & pressing establishment.
Jun 20, 1979
Open — Not complied with - ANon-hazardous
D26-10.01 adm code replace with new the missing glass street to public hall vestibule door.
Jun 20, 1979
Closed — Violation closed - ANon-hazardous
D26-15.01 adm code provide adequate supply of cold water for the fixtures bathroom & kitchen 4 sty apt 4. , section '' ''
Nov 20, 1975 · Apt 4
Closed — Violation closed - ANon-hazardous
D26-10.01 adm code repair the broken or defective plastered surfaces and paint in a uniform color ceilings 3rd sty apt 4 bathroom & front room. , section '' ''
Nov 20, 1975 · Apt 4
Closed — Violation closed - ANon-hazardous
D26-20.01 adm code provide a peep hole in entrance door of the dwelling unit so located so as to permit a person inside the dwelling to view any person outside entrance door all apts.
Mar 21, 1973
Closed — Violation closed - ANon-hazardous
D26-11.01, 11.03, 11.05 adm code remove the accumulation of refuse and/or rubbish and maintain in a clean condition the cellar throughout.
Mar 21, 1973
Closed — Violation closed - BHazardous
D26-10.01, 10.05 adm code arrange and make self-closing the doors public hall bulkhead door roof.
Mar 21, 1973
Closed — Violation closed - ANon-hazardous
D26-10.01 adm code refit public hall bulkhead door roof.
Mar 21, 1973
Closed — Violation closed - ANon-hazardous
D26-12.01 adm code paint with light colored paint to the satisfaction of this department walls ceilings & trim public hall all stys.
Mar 21, 1973
Closed — Violation closed - ANon-hazardous
D26-15.01 adm code provide adequate supply of cold water for the fixtures 4th sty apt 4 all cold water fixtures. , section '' ''
Jan 30, 1971 · Apt 4
Closed — Violation closed - BHazardous
D26-15.01 adm code provide adequate supply of hot water for the fixtures 4th sty apt 4 all hot water fixtures. , section '' ''
Jan 30, 1971 · Apt 4
Closed — Violation closed
DOB building violations · 5
- Low pressure boiler boiler required
Violation issued-failure to file 2024 external low pressure inspection
Nov 14, 2025
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Jan 17, 2020
Dob violation - dismissed
ECB violations · 4
- Class - 2
Occupancy contrary to that allowed by the cofo noted:@ 2nd flr apt.aptis currently being occupied as "body work"massage salon w/massage tables set up for use as massage spa contrary to c/o#12413 of 1927 which s
Jun 7, 2010 · Penalty $1,200
Resolve - Non-hazardous
Work without a permit. new studs with sheetrock to form partition at rear point floor new metal door (dry cleaners) noted: work completed except for hanging of metal door. remedy: obtain approvals and permits
Jul 9, 2003 · Penalty $2,500
Resolve - Non-hazardous
Failure to maintain building defect are: (1) stairway rail unkeyed 3rd to 4th floor (2) stair treads loose /unkeyed 2nd to 3rd flr (3) bathroom sheet rock wall eroded 1st flr (4) wooden floor has holes tiles mi
Jul 30, 1996 · Penalty $1,000
Resolve - Non-hazardous
Failure to post sign with occupant and machine loeas at 1st and 2nd floor. remedy: post load sign for 1st and 2nd floor.
Sep 28, 1988 · Penalty $1,500
Resolve
Complaints
- General
Signage missing
Feb 4, 2016 · Apt 3
Close - Heat/hot water
Entire building
Jan 28, 2015 · Apt BLDG
Close - Heat/hot water
Apartment only
Jan 8, 2015 · Apt 2NDFL
Close - Plumbing
Water supply
Jan 23, 2014 · Apt 4
Close - Heating
Heat related
Apr 5, 2013 · Apt NA
Close - Nonconst
Vermin
Apr 5, 2013 · Apt 3
Close - Nonconst
Vermin
Apr 5, 2013 · Apt 3
Close - Nonconst
Vermin
Apr 5, 2013 · Apt 3
Close - General
Doors
Apr 5, 2013 · Apt 3
Close - General
Floor
Apr 5, 2013 · Apt 3
Close
Show 4 more ↓
- General
Floor
Apr 5, 2013 · Apt 3
Close - General
Floor
Apr 5, 2013 · Apt 3
Close - General
Floor
Apr 5, 2013 · Apt 3
Close - Heating
Heat related
Apr 5, 2013 · Apt 5
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Mixed residential and retail building (S3)
- Year built
- 1920
- Floors
- 4
- Residential units
- 3
- Building area
- 4,460 ft²
- Lot area
- 1,495 ft²
- Zoning
- R10
- Community board
- 106
- Council district
- 4
- Block / lot
- 895 / 27
- Assessed value
- $1,556,100
- Landmark / historic district
- No
HPD registration #128271, last renewed Jun 30, 2025.
Questions about 337 Lexington Avenue
Who owns 337 Lexington Avenue?
The owner of record in NYC Department of City Planning PLUTO data is Ak Properties Group.
Does 337 Lexington Avenue have violations?
Yes. NYC HPD has recorded 37 housing violations at this property.
Is 337 Lexington Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 337 Lexington Avenue built?
City records list 1920 as the year it was built.
How many apartments are in 337 Lexington Avenue?
It has 3 residential units and 4 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.