126 Lafayette Street
Manhattan, NY 10013BBL 1-00209-0021Map
Owner of record: Yee Tai Enterprisescorp
126 Lafayette Street is a vacant lot in Manhattan, 10013. The owner of record is Yee Tai Enterprisescorp. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 30
- ECB violations
- 40
- HPD complaints
- 1
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 30
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 4, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - dismissed - Construction other optional
C-construction other optional
Mar 10, 2023
Dob violation - dismissed - Construction other optional
C-construction other optional
Mar 10, 2023
Dob violation - dismissed - Construction other optional
C-construction other optional
Mar 10, 2023
Dob violation - dismissed - Construction other optional
Vio23-50194
Mar 7, 2023
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 29, 2018
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 3, 2016
Dob violation - resolved - Construction other optional
Failure to maintain building
Sep 15, 2015
Dob violation - dismissed
Show 20 more ↓
- Elevator elevatorrequired
E-elevator elevatorrequired
Mar 11, 2015
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 10, 2014
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 4, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 9, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 1, 2009
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 29, 2008
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Mar 21, 2008
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 6, 2007
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 28, 2007
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 9, 2006
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 31, 2005
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 13, 2004
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 5, 2003
Dob violation - resolved - Elevator elevatorrequired
1p3443
May 16, 2002
Dob violation - resolved - Construction other optional
C-construction other optional
Nov 22, 1999
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 29, 1995
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 27, 1995
Vp*-violation unserved ecb- dismissed - Electric signs none
Es-electric signs none
Mar 28, 1990
Dob violation - dismissed - Electric signs none
Es-electric signs none
Mar 28, 1990
Dob violation - dismissed - Elevator elevatorrequired
(47) repair riser pipe to controller board (51) provide proper lighting in cab
Aug 30, 1988
Dob violation - resolved
ECB violations · 40
- Class - 2
Work does not conform to plans. at exposure 4, between stairs a and b, wall type ex-3 on arch and wall type wt-02a.1 requires r-15 cavity insulation. contractor installed r-8 insulation., conform work to approv
Oct 14, 2026 · Penalty $1,250
Active - Class - 1
At time of inspection, observed suspended scaffold not installed per approved construction documents, contrary to ac 28-105.12.2. approved drawing requires two wire-rope lines at each outrigger, one on the thim
Sep 25, 2026 · Penalty $2,500
Active - Class - 2
At time of inspection, observed garbage removal operations being conducted in the street and sidewalk without a required flag person, contrary to bc 3307.4.4, failing to provide traffic control and protection d
Sep 25, 2026 · Penalty $2,400
Active - Class - 1
At time of inspection, observed required vertical safety netting at multiple floors and exposures not properly maintained, contrary to bc 3308.5. observed loose netting and missing and loose cables, resulting i
Sep 25, 2026 · Penalty $10,000
Active - Class - 1
At time of inspection, observed area below suspended scaffold at setback on the corner of exposures 2 and 3 without overhead protection and required caz not maintained, contrary to bc 3301.2, creating falling-o
Sep 25, 2026 · Penalty $5,000
Active - Class - 2
Responding to an incident that occurred on 08-12-2026 at approx. 5:30 pm were an electrical pallet jack ride over a worker foot while he was moving it. inspection revealed that the worker did not have proper tr
Aug 18, 2026 · Penalty $5,000
Resolve - Class - 1
At time of inspection of proposed 25 story building observed broken window at 123 lafayette st from unsafe concrete operations where it was reported while cleaning concrete hose ball was caught and connection w
Jul 20, 2026 · Penalty $10,000
Resolve - Class - 1
At time of inspection of a proposed 25 stories building at 4 stories framing level, i observed pedestrian sidewalk was blocked causing the pedestrian to walk under the sidewalk shed which was installed inside t
May 1, 2026 · Penalty $2,500
Resolve - Class - 1
At time of inspection, it was noted that on february 17, 2026, an incident involving worker keny jose bolanos was reported to have occurred at the job site, and the general contractor failed to immediately noti
Apr 17, 2026 · Penalty $5,000
Resolve - Class - 1
At time of inspection, it was noted that on 02/17/2026, an incident involving worker keny jose bolanos was reported to have occurred at the job site, and the general contractor failed to notify the department a
Apr 17, 2026 · Penalty $10,000
Resolve
Show 30 more ↓
- Class - 2
At the time of inspection, i observed workers erecting a deck at the 1st floor. workers were using personal fall arrest systems with lifelines clipped onto rebar stirrups as anchorage. stirrups are not designed
Apr 7, 2026 · Penalty $5,000
Resolve - Class - 2
Observed occupancy of street along expo 1 comprising construction fence, jersey barriers/ yodocks for pedestrian walkway not conforming to approved site safety plan. curb to jersey barrier measures 18' v/s 8' o
Dec 4, 2025
Resolve - Class - 1
At time of inspection, the site safety plan did not include a required controlled access zone (caz). no access agreement was in place with the adjoining property. suspended scaffold was present above exposure 4
Dec 1, 2025 · Penalty $2,500
Resolve - Class - 2
Observed at exp1 job fence installed multiple non illuminated advertising business signs reads " reebok & kodak" & "little spoon" & "paige" & "dkny" & "baciami" all with no permits or approvals from dob, obtain
Oct 8, 2025 · Penalty $1,250
Resolve - Class - 2
At the time of inspection, the construction fence at exposure 1 was observed collapsed onto the sidewalk, posing a risk to public safety, with permit number m00705568-i1-fn expired on 02/17/2024.renew and maint
Oct 16, 2024
Resolve - Class - 2
At the time of inspection, the construction fence at exposure 1 was observed to be partially collapsed onto the sidewalk, posing a clear risk of injury to pedestrians.
Oct 16, 2024 · Penalty $1,000
Resolve - Class - 1
Failure to notify the department of an acident.incident that resulted in a fatality or an injury.note:4 workers were suffered injury when doing demolition wall collapse or the 2nd floor workers were taken to ho
Apr 11, 2023 · Penalty $25,000
Active - Class - 1
At time of inspection observed shanty in place not made of fire rated materialuse fire rated materials
Feb 6, 2023 · Penalty $6,250
Resolve - Class - 1
At time of inspection observed hazardous materials of demolition first floor loaded with joists, fixtures elevator components and glass still in place. failure to remove hazardous fixtures before commencement
Feb 6, 2023 · Penalty $6,250
Resolve - Class - 1
At time of inspection i observed sprinklers removed throughout building before demolition not maintained by code.maintain as per code.
Feb 6, 2023 · Penalty $6,250
Resolve - Class - 1
At time of inspection observed supported scaffold in place with tarps on each side causing a hazardous condition.remove tarps
Feb 6, 2023 · Penalty $6,250
Resolve - Class - 1
At time of inspection observed on first floor 3x12 lumber stored approximately 50 ton causing overload.remove lumber
Feb 6, 2023 · Penalty $6,250
Resolve - Class - 2
Observed jobsite fence at exp#1 with excessive advertising posters- posted/glued onto approx. 70% of the fence- with multiple visible layers underneath, indicating the advertising posters are not regularly remo
Nov 16, 2022
Resolve - Class - 2
At time of inspection of building 3 story inactive job site observed construction fence installed at exp1 and not maintained as per code bc 3307.4.6, observed construction fence covered with advertising at exp
Oct 7, 2022
Resolve - Class - 2
Work w/o a permit. noted: commercial bldg w/numerous illuminated & non-illuminated accessory business signs of various kinds & dimensions,including banners,awnings,illuminated projecting box signs text include
Dec 31, 2014 · Penalty $800
Resolve - Class - 1
Failure to provide unobstructed exit passageway defects noted: at time of inspection there is a bicycle stored in hallway & exit stairwell is obstructed w/boxes,bucket,garbage pale,mops & a hand truck.
Jun 14, 2011 · Penalty $1,200
Resolve - Class - 1
Work w.o permit. plumbing. upon inspection at above address on the 2ndfl newly installed plumbing work was going on at time of inspection. newly installed hot & cold water lines were installed in a few bathroo
Feb 9, 2009 · Penalty $1,600
Resolve - Non-hazardous
03i10,15m07,12b07,12q03,84x10,16p07,17l11,21q11,33o02,38q02,41b02,25w06,51m07,51o06,44b06,66o02,44m13. 12b07-bulbs out provide more lighting84x10-communication is not working repair as needed 16p07-2nd and base
Mar 25, 2004 · Penalty $180
Resolve - Non-hazardous
09,i,10 38,i,10 car dome and floor unsafe
Jun 12, 2003 · Penalty $500
Resolve - Non-hazardous
Failure to maintain bldg noted: at various locations fire rated doors to corridor not self closing. emergency lighting in corridor missing at stairwell to center entrance. directional signs/exit signs not pro
Nov 22, 1999 · Penalty $180
Resolve - Non-hazardous
Occupancy contrary to that allowed by certificate of occupancy. noted:at 2nd floor level north side premises being used as an office space with sleeping accomodation contrary to c.o. #16695 which states 2nd fl
Nov 22, 1999
Resolve - Non-hazardous
18m,18q,57p,75u,74x. provide covers on inter lock. green feild to interlock, remove gallon drum from side of elevator.
Oct 13, 1999 · Penalty $350
Resolve - Non-hazardous
14m11q22d30h75u18m32m35p36p57o2d 18-inerlock cover missing 32-duct cover missing top car 2-secure alarm bell under car.
May 27, 1998 · Penalty $350
Resolve - Non-hazardous
11b14m22d74m57o07h16h09h15p01i05i 74 capacity sign in car 07-replace safety edge 15-no access to basement 01-replace stop switch in car.
Oct 1, 1997 · Penalty $1,000
Resolve - Non-hazardous
57o, 3o, 11l. repair & provide covers.
Mar 27, 1995 · Penalty $100
Resolve - Non-hazardous
Failure to provide elevator landing signs (10"*12") at each landing. failure to provide floor number signs (3") at stair landings. failure to provide stair and elevator identification throughout floors. remedy-
Nov 23, 1993 · Penalty $600
Resolve - Non-hazardous
73#,73o, (73) perform 5 year test, properly tag device & file elv-3 form
Jun 30, 1992
Resolve - Non-hazardous
21l,36l,11l,11l,50y,73o,74l,74l,73#,3i,74a#,11 repair or renew & provide covers 74 repair or renew the safety edge 73# 5 perform 5 yr test, date & tag governor & file elevator 3 form with this department 74a pr
Oct 4, 1991 · Penalty $150
Resolve - Non-hazardous
74m,74 provide an outside alarm system
Oct 4, 1991 · Penalty $150
Resolve - Non-hazardous
11l,14m,8l,74l,46#,47#,74a,38l,74bo,17m,(74)repair safety edge (46)&(47)shorten hoist&governor cable (74a)repair risen pipe to controller (74b)clean car top (17)provide grills
Dec 19, 1990 · Penalty $150
Resolve
Complaints
- Plumbing
Water supply
Oct 11, 2014 · Apt BLDG
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Vacant lot (V1)
- Year built
- —
- Floors
- —
- Residential units
- —
- Building area
- —
- Lot area
- 6,295 ft²
- Zoning
- M1-5/R10
- Community board
- 102
- Council district
- 1
- Block / lot
- 209 / 21
- Assessed value
- $516,600
- Landmark / historic district
- No
Questions about 126 Lafayette Street
Who owns 126 Lafayette Street?
The owner of record in NYC Department of City Planning PLUTO data is Yee Tai Enterprisescorp.
Does 126 Lafayette Street have violations?
NYC HPD has no housing violations on record for this property.
Is 126 Lafayette Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.