49 Ann Street
Manhattan, NY 10038BBL 1-00092-0014Map
Owner of record: Fkal 49 Ann Street LLC
49 Ann Street is a hotel built in 2012 in Manhattan, 10038. The owner of record is Fkal 49 Ann Street LLC. HPD has recorded 11 housing violations here, most recently on November 17, 2025.
- HPD violations
- 11
- DOB violations
- 37
- ECB violations
- 41
- HPD complaints
- 7
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 11
- IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 17, 2025
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Jun 13, 2025
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 17, 2024
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 15, 2023
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Mar 31, 2023
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 3, 2022
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Mar 10, 2022
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 20, 2021
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Apr 20, 2021
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 6, 2019
Closed — Violation dismissed
Show 1 more ↓
- IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 30, 2016
Closed — Violation dismissed
DOB building violations · 37
- No report and / or late filing (facade) facade required
Failed to file fisp cycle 9c technical report by 2/21/2024
Feb 22, 2024
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2023
Dob violation - dismissed - Construction other optional
Parking garage structure at 57 ann street partially collapsed and remaining structure potential collapse condition and this building within the collapse zone. required building's structural stability assessment.
Apr 20, 2023
Dob violation - dismissed - Construction other optional
Due to a dangerous condition at 57 ann st. causing an immediate hazard to the occupants of the above premise
Apr 18, 2023
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 1, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 1, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 19, 2020
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 19, 2020
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 27, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 27, 2017
Dob violation - resolved
Show 27 more ↓
- Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2015 inspection/test
Dec 1, 2016
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2015 inspection/test
Dec 1, 2016
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 26, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 26, 2016
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2013 inspection/test
Oct 31, 2014
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2013 inspection/test
Oct 31, 2014
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2010 inspection report
Dec 13, 2011
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 20, 2010
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Vcat1-elevator annual inspection / test elevatorrequired
Oct 8, 2010
Dob violation - dismissed - Low pressure boiler boiler required
Lblvio-low pressure boiler boiler required
Dec 31, 2009
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Feb 27, 2009
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 1, 2009
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 23, 2007
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 24, 2006
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 8, 2005
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 13, 2004
Dob violation - active - Elevator elevatorrequired
1p6964
Sep 27, 2000
Dob violation - resolved - Elevator elevatorrequired
1p6964
Sep 9, 1999
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 16, 1999
Dob violation - dismissed - Elevator elevatorrequired
1p6964
Dec 21, 1998
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - active - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 18, 1996
Vp*-violation unserved ecb- dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 29, 1995
Dob violation - active - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 18, 1993
Dob violation - dismissed - Elevator elevatorrequired
(01)repair water damage to controller (15)service (51)provide proper sky light (52)provide capacity plate
Apr 17, 1989
Dob violation - resolved - Elevator elevatorrequired
(51) restore elevator to proper working order so a complete inspection can be made by this department
Nov 15, 1988
Dob violation - resolved
ECB violations · 41
- Class - 2
Failure to submit an acceptable required cycle 9c report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control #917308. remedy: submit acceptable requ
Apr 8, 2025 · Penalty $2,500
Resolve - Class - 1
Failure to comply with the commissioner's order in dob violation vio23-01094, dated 4/20/2023. respondent was required to submit an engineer's report concerning structurally deficient conditions. as of 10/11/20
Oct 11, 2023
Resolve - Class - 1
Failure to have site safety manager/coordinator present on site an required. at time of my inspection observed 18 story new bldg under construction - approx 10 workers on site. bt no ssm on site. my inspection
Jul 23, 2014 · Penalty $1,200
Resolve - Class - 2
Failure to maintain adequate housekeeping per section requirements.@ time of insp observed active jobsite 18 story bldg debri & material on roof of bldg not cleaned or stored properly aloso debri and material o
Jun 18, 2014
Resolve - Class - 1
3301.2 failure to maintain-sidewalk shed.time of insp observed active jobsite sidewalk shed erected @ exp1 as a means of overhead protectionfor pedestrian.sidewalk shed mud sill has been broken away from uprigh
Apr 3, 2014 · Penalty $1,600
Resolve - Class - 2
Temporary const equipment on site sidewalk shed expired permit,@ the time of insp observed appx.100l.f.sidewalk shed has been erected @ exp1permit #121017489.the permit expired on 04/01/14.rem:renew permit.
Apr 3, 2014
Resolve - Class - 1
Failure to maintain adequate housekeeping per section requirements. attime of inspection observed active job site 18 stys high, interior trades working throughout job site.upon my inspection i observed multiple
Mar 1, 2014 · Penalty $2,400
Resolve - Class - 1
Failure to institute/maitain safety reassure or temp const - no toe boards. at time of inspection observed active 18' sty job site - interior trades working - staircase b flrs 1,2,3 had no toe boards on stair
Mar 1, 2014 · Penalty $1,000
Resolve - Class - 1
Sec. bc 3301.7 design required by the chapter 33. at time of inspection observed active job site 18 stys - interior (grades) working throughout. pipe scaffold erected on exp 3 approx 184' in height. no design
Mar 1, 2014 · Penalty $1,600
Resolve - Class - 1
Sec. bc 28-301.1. owner's responsibility. all bldgs and all parts there for and all other structures shall be maintained in a safe condition. no adequate lighting. time of inspection on flrs 3 and 4 inadequate
Oct 31, 2013 · Penalty $1,600
Resolve
Show 31 more ↓
- Class - 1
Failure to maintain adequate housekeeping per section requirements noticed at time of inspection nb thru out entire site inadequate housekeeping causing tripping and other hazards. remedy: maintain adequate
Oct 31, 2013 · Penalty $2,400
Resolve - Class - 1
Failure to safeguard all persons and property affected by constructionoperations. noticed at time of inspection electrical cords on flrs, blocking egress, hanging down off ceilings causing tripping and egress
Oct 31, 2013 · Penalty $2,400
Resolve - Class - 1
Failure to institute/maintain safety equipment measures - no toe board.note:toe boards missing around both staircases & at perimeter of bldg @ the 17th,16,15,14,13 floors.remedy:install/maintain toe boards.
Jun 4, 2013 · Penalty $1,000
Resolve - Class - 1
3301.2 holes/openings not covered thruout bldg-@at perimeter and @center penetrations for pipes & ductwork has been ( ) but has not been covered.rem:cover all holes/openings.
Jun 4, 2013 · Penalty $1,600
Resolve - Class - 1
Work does not conform to approved const. documents &/ot approved amendments.note:design plans for elevator shaft area has not been followed.plywood & structural members had not been installed.rem:conform to des
Jun 4, 2013 · Penalty $1,000
Resolve - Class - 1
3308.3 vertical safety netting not per code:damaged or inadequate.noted:nets are loose/not secured to (zero) cables @permiters-18th,17th,16th,15th,&14th flrs.rem:secure/maintain nets.
Jun 4, 2013 · Penalty $1,600
Resolve - Class - 1
Fail to safeguard all persons/prop affected by const operations.noted:@elevator shaft areas from 17th thru 3rd flrs have not been protected-unsecured or fastened plywood-person can fall.rem:secure entire elevat
Jun 4, 2013 · Penalty $2,400
Resolve - Class - 1
Sec. 1704.22.1.1 failure to file po-98 for hydrostatic test as required when bldg reaches a height of 75'-0". note at time of inspection bldg complete to 10 stories stand pipe installed to 7th fl (77') no recor
Feb 20, 2013 · Penalty $1,600
Resolve - Class - 2
Failure to provide approved/accepted plans at job site at time of inspection. note no drawings provide for scaffold protection installed over watere tank of adjacent property & on set back 5th fl at exposure 1
Feb 20, 2013
Resolve - Class - 1
Sec. bc 3301.2. failure to institute/maintain safety equipment measures or temporary construction. at time of inspection observed guard rails. missing at stair opening at exp 4, 4th flr to 9th flr as required
Feb 4, 2013 · Penalty $1,600
Resolve - Class - 1
Sec bc 3301.7. design drawing required for planking & support in elevator shaftway. at time of inspection no professional engineer drawings provided upon request for planked out elevator shaftway to 10th flr.
Feb 4, 2013 · Penalty $1,600
Resolve - Class - 1
Sec. bc 3308.3. vertical safety netting not per code, missing and inadequate. note at time of inspection observed vertical safety netting missing at exp 4 se corner of bldg, 5th flr & @ 5 & 6 flr exp 1 vertical
Feb 4, 2013 · Penalty $1,600
Resolve - Class - 1
Sec. bc 3308.2. failure to provide horizontal safety netting per code.note: at time of inspection bldg complete to 10 stories, form work decking 11th flr and not horizontal, nets provided as per approved site
Feb 4, 2013 · Penalty $1,600
Resolve - Class - 1
Failure to have site safety manager present as required.note at time of inspection observed workers maintaining housekeeping and stripping operation of 1st flr w/o site safety manager present.rmdy:stop all wor
Nov 2, 2012 · Penalty $2,400
Resolve - Class - 2
Sec. 3310.6 failure to have designated site safety manager as indicated on pw-2, present site at minimum of once every 2 weeks. examination of site safety managere log for dates 5.1.12 to 7.2.12 indicates
Jul 2, 2012
Resolve - Class - 2
Sec. 3310.6. failure to have designated site safety manager as indicated on pw-2 present on site at a minimum of once every 2 weeks. examination of site safety logs per dates 5.7.12 to 7.21.12 indicates that
Jul 2, 2012
Resolve - Class - 2
Sec. 3307.2.1. failure to provide level walking surface. on sidewalk at time of inspection construction ongoing at exp 1 front of construction site facia sidewalk is an (uneven) surface w/cracks and bumps that
Jul 2, 2012
Resolve - Class - 1
Work does not conform to approved construction documents. at time of inspection observed waters and rakers installed @ south elevation exp 1. not installed as per engineer drawings also a section of (lagging)
Jul 2, 2012 · Penalty $1,030
Resolve - Class - 1
Sec. 28-105.12.8 work is not in accordance w/site safety plan. noted at time of inspection construction fence at exposure 1 is on sidewalk w/a 5' pedestrian walkway. site safety plan calls for construction fenc
Apr 5, 2012 · Penalty $1,600
Resolve - Class - 1
27-1032 stop all work pursuant to section 28-207.2 of the a/c of nyc you are hereby ordered to immediately stop all work at premises other than what is allowed in rescind issued 3/7/12 failure to protect and ad
Mar 7, 2012 · Penalty $1,600
Resolve - Class - 1
Failure to maintain bldg walls or appurtenances. noted: defects.roof: 1) at roof a substantially flat surface weather proofing membrane has been removed. 2) perimeter e/w flashing is curled up allowing water
Apr 6, 2010 · Penalty $5,000
Resolve - Class - 1
Sec. 28-207.3. public nuisance (2 bldgs on lot). noted: a 4 sty attached bldgs conditions pose a nuisance in that: 1) 49/51 are vacant. 49 bulkhead door open, 4th flr front door open. bldgs drains debris
Apr 6, 2010 · Penalty $8,000
Resolve - Class - 1
Failure to maintain exterior of bldg defects on the south elevation on the 4 fl brick have missing mortar joints loose and defective masonry remedy:maintain exterior of bldg
Jan 16, 2010 · Penalty $2,500
Resolve - Class - 1
Failure to maintain bldg walls or appurtenances in code compliant manner note top left corner of exp 1 4th fl bricks have deteriorated missing mortar is missing in various locations thru-out the bldg support fo
Aug 14, 2009 · Penalty $5,000
Resolve - Class - 2
Failure to maintain bldg walls no appurtenances, defects noted: at exposure (1) 4th and 3rd fl level spalling paint and brick facade need pointing to prevent bricks from further deteriorate. rem: maintain ext b
Jul 28, 2009 · Penalty $2,500
Resolve - Class - 1
Failure to provide unobstructed exit passageway. noted: 1st flr thru 4th flr stair passageway is littered w/boxes of printing supplies, garbarge. remedy: remove obstruction.
Jul 21, 2009 · Penalty $1,200
Resolve - Class - 1
Failure to maintain bldg in code-compliant manner. noted: at roof level. roof protection membrane removed during (abatement) process leaningwood ceiling exposed to the weather. at exposured 2, 2nd flr window at
Jul 21, 2009 · Penalty $1,000
Resolve - Class - 2
Failure to maintain facade wal broken windows cracks missing pointing missing stucco loose brickwork rem: maintain exterior bldg walls
Nov 18, 2008 · Penalty $500
Resolve - Class - 2
Failure to maintain facade wall noted missing pointing missing stucco missing paint loose brickworks rem: maintain exterior bldg walls
Nov 18, 2008 · Penalty $2,500
Resolve - Non-hazardous
Exit passage or corridor required width decreased by obstruction noted: stairway "a" is obstructed with plywood (z'x4'), ladders,bags of garbage on level 4th floor. remedy: remove obstruction
Jan 25, 2008 · Penalty $2,500
Resolve - Non-hazardous
35m07/ 47i12/ 55m07/ 60q06 / 35 provide g.f.c.i. outlet, fire extingusher, smoke detechtor 47. governor cable 55. provide pit light 57. provide g.f.c.i. outlet 57. provide pit ladder 60. properly secure coun
Jan 30, 2002
Resolve
Complaints
- Unsanitary condition
Pests
May 24, 2022 · Apt ROOM80
Close - Unsanitary condition
Pests
Jan 28, 2021 · Apt BLDG
Close - Unsanitary condition
Pests
Oct 4, 2020 · Apt 405
Close - Unsanitary condition
Pests
Oct 4, 2020 · Apt ALLROO
Close - Unsanitary condition
Pests
Oct 4, 2020 · Apt ALLROO
Close - Unsanitary condition
Pests
Oct 4, 2020 · Apt 405
Close - Unsanitary condition
Pests
Dec 13, 2019 · Apt RM708
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Hotel (H2)
- Year built
- 2012
- Floors
- 18
- Residential units
- —
- Building area
- 56,790 ft²
- Lot area
- 4,581 ft²
- Zoning
- C6-4
- Community board
- 101
- Council district
- 1
- Block / lot
- 92 / 14
- Assessed value
- $9,852,750
- Landmark / historic district
- No
HPD registration #144016, last renewed Nov 26, 2025.
Questions about 49 Ann Street
Who owns 49 Ann Street?
The owner of record in NYC Department of City Planning PLUTO data is Fkal 49 Ann Street LLC.
Does 49 Ann Street have violations?
Yes. NYC HPD has recorded 11 housing violations at this property.
Is 49 Ann Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 49 Ann Street built?
City records list 2012 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.