roofy
Data report

DOB Safety Violations: Boilers, Elevators, Benchmarking and LL97

DOB issued 149,069 safety violations in 2025, most for missed gas piping, boiler and elevator filings. See every code in plain English, by borough, plus LL97.

Updated October 12, 2026 · Data: NYC Department of Buildings via NYC Open Data

The Department of Buildings issued 149,069 safety violations in 2025, at 115,944 different buildings. Almost all were for paperwork an owner did not file on time: 60% were for gas piping inspections, and elevators and boilers made up most of the rest. Local Law 97 emissions violations were rare in 2025 (633) but reached 4,468 in 2026 through 2026-10-12.

Roofy data

DOB safety violations, 2025

Violations in DOB NOW with an issue date from January 1 to December 31, 2025

149,069
violations issued, at 115,944 buildings
60%
were gas piping (Local Law 152) filings not made (89,163)
30,175
elevator test and inspection filing violations
24,545
boiler inspection filing violations
633
Local Law 97 emissions violations in 2025
4,468 so far in 2026
89%
still active on 2026-10-12
Source: NYC DOB, DOB Safety Violations (855j-jady) · as of 2026-10-12 · roofy.io

What these violations are

DOB Safety Violations are civil penalties issued in DOB NOW for the city's periodic compliance programs: gas piping, boilers, elevators, facades, energy benchmarking and building emissions. Unlike a violation written by an inspector who saw a dangerous condition, most of these are for a required report or correction that DOB did not have on record by the deadline. Many codes start with FTF (failure to file) or FTC (failure to file a correction after defects were found). The dataset's own remarks describe each code; we translate them in the table below.

The most common violation types

Top 12 DOB safety violation types, 2025
Violations issued in 2025, plain-English labels
  • Gas piping cert. not filed89.2K
  • Low-pressure boiler report not filed18.5K
  • Elevator CAT1 correction not filed9,591
  • Elevator periodic correction not filed9,208
  • Elevator periodic report not filed5,212
  • Elevator CAT1 report not filed4,423
  • Boiler correction not filed4,329
  • Benchmarking report not filed2,645
  • High-pressure boiler report not filed1,648
  • Hazardous summons not corrected1,095
  • Elevator CAT1 report (NJ)982
  • LL97 emissions report not filed488

Source: NYC DOB, DOB Safety Violations (855j-jady) · data as of 2026-10-12

Gas piping: 89,163 in 2025

Under Local Law 152, buildings other than one- and two-family homes (and other R-3 occupancies) must have a licensed master plumber inspect their gas piping at least once every four years, on a schedule set by community district. Failing to file the certification can bring a $5,000 civil penalty. DOB says it began issuing notices of deficiency for Cycle 1 in January 2025, and the data matches: every 2025 gas piping violation cites Cycle 1, issued in three batches covering sub-cycle D (32,111), sub-cycle B (29,763) and sub-cycle C (27,289). In 2026 so far DOB has issued 21,505 more, all for Cycle 2 sub-cycle A. Nearly every 2025 notice went to a different building, and 95% were still active on 2026-10-12.

Elevators: 30,175

DOB's elevator rules require an annual periodic inspection and an annual Category 1 safety test, with defects fixed within 90 days and a correction filed within 14 days after that. The 2025 violations cover the 2024 cycle. More than half (18,799) were for corrections not filed, not for missing inspections. See our elevator report for the full breakdown.

Boilers: 24,545

Low-pressure boilers in buildings with six or more apartments, and in commercial and mixed-use buildings, need an annual inspection, with the report due within 14 days (DOB boiler compliance). DOB lists a $1,000 failure-to-file penalty per boiler. The single code LBLVIO, a low-pressure boiler report not filed for 2024, accounts for 18,473 violations. Another 4,329 were for boiler defects whose correction was never filed.

Benchmarking and Local Law 97

Buildings over 25,000 gross square feet must report energy use every year by May 1 under Local Law 84, and DOB's violation notice warns of $500 penalties each quarter, up to $2,000 a year (DOB sample notice). Benchmarking violations have fallen from 9,981 in 2019 to 2,720 in 2025, though DOB has already issued 3,467 in 2026 through 2026-10-12, so the drop may partly reflect batch timing.

Energy benchmarking (LL84) violations issued per year
2019–2025, by violation issue date
10K5K02019202020212022202320242025
Hover the chart for exact values.

Source: NYC DOB, DOB Safety Violations (855j-jady) · data as of 2026-10-12

Local Law 97 also covers buildings over 25,000 gross square feet. Article 320 buildings must file an emissions report every May 1, starting May 1, 2025, and Article 321 buildings (certain affordable housing and houses of worship) had to file a report of compliance by May 1, 2025. DOB issued its first batch of LL97 violations in this dataset in December 2025: 488 Article 320 and 145 Article 321. In 2026 through 2026-10-12 it has issued 3,712 more tied to Article 320 and 756 tied to Article 321. Most of these are for reports not filed; they do not tell you whether a building is over its emissions limit.

By borough

Brooklyn had the most 2025 safety violations (57,823), then Queens (36,171). That ranking mostly reflects which community districts the 2025 gas piping batches covered, since gas piping makes up 70% of Brooklyn's total. Manhattan, with the most elevators, had the most elevator violations (14,353).

DOB safety violations by borough and category, 2025
Stacked: gas piping, elevators, boilers and all other categories
Gas piping Elevators Boilers All other
57.8K28.9K0
Brooklyn
Queens
Manhattan
Bronx
Staten Island

Source: NYC DOB, DOB Safety Violations (855j-jady) · data as of 2026-10-12

Every 2025 code, explained

DOB safety violation types issued in 2025
CodeMeaningCategoryIssuedStill active
FTF-PL-PERGas piping (Local Law 152): periodic inspection certification not filedGas piping (LL152)89,16395%
LBLVIOLow-pressure boiler: annual inspection report not filedBoilers18,47386%
FTC-VT-CAT1-COElevator: correction of Category 1 test defects not filedElevators9,59175%
FTC-VT-PER-COElevator: correction of periodic inspection defects not filedElevators9,20876%
FTF-VT-PER-COElevator: periodic inspection report not filedElevators5,21281%
FTF-VT-CAT1-COElevator: Category 1 test report not filedElevators4,42381%
FTC-BE-EXT-LPLow-pressure boiler: correction of external inspection defects not filedBoilers4,32990%
FTF-EN-BENCHEnergy benchmarking (Local Law 84) report not filedBenchmarking (LL84)2,64572%
HBLVIOHigh-pressure boiler: internal or external inspection report not filedBoilers1,64891%
FTC-AEU-HAZNo accepted certificate of correction for a Class 1 immediately hazardous construction-site summons (AEUHAZ)Hazardous summons (AEUHAZ)1,09534%
FTF-VT-CAT1-NJElevator: Category 1 test report not filed (NJ variant)Elevators98291%
FTF-EN-LL97320Local Law 97, Article 320: annual emissions report not filedEmissions (LL97)48891%
(blank)Retaining wall violation (no type code recorded)Retaining walls35121%
FTC-VT-PER-HAElevator: correction of periodic inspection defects not filed (HA variant)Elevators2510%
FTC-VT-CAT1-HAElevator: correction of Category 1 test defects not filed (HA variant)Elevators2450%
FTC-VT-CAT1-NJElevator: correction of Category 1 test defects not filed (NJ variant)Elevators20683%
FTF-SC-INITLStructurally compromised building: required report not filedStructurally compromised16591%
FTF-EN-LL97321Local Law 97, Article 321: compliance report not filedEmissions (LL97)14595%
FISPHAZFacade (FISP): unsafe report filedFacades (FISP)8288%
FISPFCSFacade (FISP): conditions rated SWARMP not correctedFacades (FISP)7991%
DQ-EN-BENCHEnergy benchmarking report not filed (DQ variant)Benchmarking (LL84)7560%
FTC-PS-UNSAFEParking structure: unsafe report filed, correction not filedParking structures5886%
FTC-BE-EXT-HPHigh-pressure boiler: correction of external inspection defects not filedBoilers4890%
FTC-BE-INT-HPHigh-pressure boiler: correction of internal inspection defects not filedBoilers4789%
FTF-VT-PER-HAElevator: periodic inspection report not filed (HA variant)Elevators330%
FTF-VT-CAT1-HAElevator: Category 1 test report not filed (HA variant)Elevators230%
FTP-EN-EGRDEAEnergy grade (Local Law 33) violation; the data gives no remarks for this codeEnergy grade (LL33)2100%
FISPNRFFacade (FISP): no report filedFacades (FISP)1100%
FTF-VT-PER-NJElevator: periodic inspection report not filed (NJ variant)Elevators10%
Source: NYC DOB, DOB Safety Violations (855j-jady), queried 2026-10-12. Meanings come from each code's violation remarks. DOB does not define the DQ prefix or the CO/HA/NJ elevator suffixes in the public data.

Two smaller codes are about real hazards rather than missing paperwork. FISPHAZ (82) marks a facade inspection report that found unsafe conditions, which under FISP means public protection such as a sidewalk shed must go up right away. FTC-AEU-HAZ (1,095) means DOB has not accepted a certificate of correction for a Class 1 immediately hazardous summons at a construction site (DOB service notice).

Limits of this data

  • DOB issues these in batches after each filing cycle closes, so year-to-year totals swing with batch timing. We do not compare annual totals across categories for that reason.
  • "Active" is the status on 2026-10-12. An active violation can mean the penalty is unpaid even if the report has since been filed.
  • The dataset only holds violations issued or payable in DOB NOW. Older violations and OATH/ECB summonses are in other DOB datasets and are not counted here.
  • A violation for a missing report is not proof the equipment is unsafe. It means DOB had no filing on record by the deadline.
Fact-checked October 12, 2026

Independent re-check on 2026-10-12: re-ran all 8 saved SoQL queries against 855j-jady and every figure matched (149,069 violations at 115,944 BINs in 2025; 132,608 active). Extra queries confirmed 89,163 gas piping violations went to 89,162 distinct BINs and pulled each code's violation_remarks to check the plain-English meanings (LBLVIO = 2024 external low-pressure inspection; FISPFCS = Cycle 9 SWARMP not corrected). Rules checked against DOB pages: LL152 coverage, 4-year cycle, sub-cycle schedule, $5,000 penalty and January 2025 NOD start; boiler six-family threshold, 14-day filing and $1,000 penalty; elevator 90+14-day correction rule; LL97 25,000 sq ft threshold, May 1 Article 320 reports and the May 1, 2025 Article 321 compliance report; benchmarking $500/quarter up to $2,000/year (DOB sample notice); FISP unsafe = immediate public protection; AEUHAZ meaning from the Dec 8, 2025 service notice. Corrected the Article 321 wording, softened the LL33 code label (no remarks in the data) and added the 2026 benchmarking count. Codes whose prefixes DOB does not explain (DQ, FTX, FTP, and the CO/HA/NJ elevator suffixes) are labeled only from their remarks.

Sources

  1. DOB Safety Violations (855j-jady) · NYC Department of Buildings via NYC Open Data (accessed October 12, 2026)
  2. Gas Piping System Periodic Inspections (Local Law 152) · NYC Department of Buildings (accessed October 12, 2026)
  3. Boiler Compliance · NYC Department of Buildings (accessed October 12, 2026)
  4. Elevator Compliance · NYC Department of Buildings (accessed October 12, 2026)
  5. LL97 Greenhouse Gas Emissions Reductions · NYC Department of Buildings (accessed October 12, 2026)
  6. Benchmarking Notice of Violation (sample) · NYC Department of Buildings (accessed October 12, 2026)
  7. Facade Inspection & Safety Program (FISP) · NYC Department of Buildings (accessed October 12, 2026)
  8. Service Notice: AEUHAZ Violations, Civil Penalty Payments, and Challenges to Launch in DOB NOW: Safety (Dec 8, 2025) · NYC Department of Buildings (accessed October 12, 2026)

General information, not legal, tax or financial advice. Rules change; confirm with the agency or a professional before you act.