111 Livingston Street
Brooklyn, NY 11201BBL 3-00266-0001Map
Owner of record: 111 Livington LLC
111 Livingston Street is an office building built in 1969 in Brooklyn, 11201. The owner of record is 111 Livington LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 222
- ECB violations
- 122
- HPD complaints
- 1
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 222
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 11, 2024
Dob violation - dismissed - Failure to post energy grade/score none
Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3
Dec 1, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - active - Failure to post energy grade/score none
Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3
Dec 1, 2022
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 19, 2022
Dob violation - dismissed - Failure to post energy grade/score none
Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3
Dec 1, 2021
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 3, 2021
Dob violation - resolved - Elevator elevatorrequired
Cease use
Aug 2, 2021
Dob violation - active
Show 40 more ↓
- Elevator elevatorrequired
E-elevator elevatorrequired
Aug 2, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 2, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 2, 2021
Dob violation - resolved - Failure to post energy grade/score none
Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3
Apr 29, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - dismissed - Sprinkler none
Failed to file final sprinkler report by july 1, 2019
Sep 3, 2019
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 21, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 21, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 21, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 21, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 21, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 27, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 27, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 27, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 27, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 27, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 27, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 27, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 27, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 27, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 27, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 27, 2018
Dob violation - resolved - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2016 inspection report
Apr 6, 2018
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
May 17, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 17, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 17, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 17, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 17, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 17, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 17, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 17, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 17, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 17, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 17, 2017
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - dismissed
ECB violations · 122
- Class - 1
97-x-17 the elevator in building out of service upon inspection the device is found to be out of service creating a hazardous condition as per 1rcny 11-02 remedy restore to service immediately and notify nycdob
Aug 5, 2026 · Penalty $1,250
Active - Class - 1
97-x-17 the elevator in building out of service upon inspection the device is found to be out of service creating a hazardous condition as per 1rcny 11-02 remedy restore to service immediately and notify nycdob
Aug 5, 2026 · Penalty $1,250
Active - Class - 2
An elevator in section of building or building is out-of-service. upon inspection the device is found to be out-of-service creating a hazardous condition as per 1rcny 11-02. restore to service immediately and n
Jan 29, 2026 · Penalty $625
Resolve - Class - 2
An elevator in section of building or building is out-of-service. upon inspection the device is found to be out-of-service creating a hazardous condition as per 1rcny 11-02. restore to service immediately and n
Jan 29, 2026 · Penalty $3,125
Active - Class - 1
28-323.8 and rcny 103-13(5). failure to secure public safety and make the building structure and appurtenances conform to previous of admin code after unsafe notification filed by qspi. note: an active parking
Oct 5, 2024 · Penalty $2,500
Resolve - Class - 2
Noted: refer to c of o# 206753 which indicates parking at cellar for 73 cars and sub-cellar with 77. at time of inspection, observed each level with more than the allowable amount of cars being stored. cellar l
May 30, 2023
Resolve - Class - 2
Noted: at time of inspection, observed the cellar and sub-cellar ceilings with missing and spalling fireproofing, q-decking that is severely rusted, flaking and some areas hanging, leaving masonry and reinforce
May 30, 2023
Resolve - Class - 1
Failure to maintain building in code-compliant manner:at the time of inspection and observed at 10th & 11th floor approx 18"x36'opening caused by cmu block removed/collapsed at stair l.rem:repair and or replace
Dec 21, 2021 · Penalty $1,250
Active - Class - 1
At time of inspection, in cmu wall at stairway l, 12" x 36" hole @ landing between 10th & llth fls & 6" x 12" hole @ landing between 11th & 12th fls, repair and/replace; repair holes in cmu block walls
Oct 25, 2021
Resolve - Class - 2
27-929.1 failure to complete the installation of a full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional by july 1,2019,in an office building 100 fee
Jul 13, 2020 · Penalty $5,000
Resolve
Show 40 more ↓
- Class - 1
No door lock monitoring installed in this controller as mandated by 3.10.12 of appendix k3 of the 2014 nycbc. this is a controller feature which ensures passenger safety. remedy; file application, install dlm a
Feb 21, 2020
Resolve - Class - 2
A.c 27-929.1,failure to complete the installation of a full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional by 7/1/2019,in an office bldg 100 ft or
Nov 15, 2019 · Penalty $1,250
Resolve - Class - 2
05-j-01,16-j-01,23-d-06,24-x-10,23-x-210=05/16j-properly align hoistway doors to car doors to keep doors engaged ()23d properly (mount) & service hall button station to present exposing to public 23y repair fir
Aug 26, 2019
Resolve - Class - 2
100r07- the owner shall have a maintenance contract with an approved agency to perform elevator repair work and maintenance. rmdy: provide a written contract with an approved agency.
May 29, 2019 · Penalty $3,125
Resolve - Class - 1
20180924
Aug 10, 2018
Resolve - Class - 2
(97,x,10)restore to service(r,t,s)
Aug 10, 2018
Resolve - Class - 2
52d6,68b7,41i10,52m7,24x10. 52d6-secure cable guard; 68b7-logbook outdated; 41i19-m/r door damaged; 52m7-antispin device missing; 24x10 23rd floor direction lantern inoperative.
Aug 10, 2018
Resolve - Class - 2
67.l.10,100.m.07,(67,l,10)phone in car is not working , repair(100,m,07)prints in motor room is missing,provide.
Aug 10, 2018 · Penalty $310
Resolve - Class - 2
20180924
Aug 10, 2018
Resolve - Class - 1
Motor room prints insufficient.brake fuse bypassed c/u item.t.o.c. inspection box inoperative.pit door lock damaged.
Aug 10, 2018
Resolve - Class - 2
41i10,98m7,42d6,42m7. 41i10-m/r door damaged repair; 98m7-5year tag missing; 42d6-properly secure relay in controller; 42m7-prints miss ing.
Aug 10, 2018
Resolve - Class - 1
59x10cu; 66a10cu; 25m7. 59x10 cease use machine brake switches inoperative; 66a10-cease use-rope gripper altered and rendered inoperative these 2 devices are safety devices to ensure the safety of elevator pa
Aug 10, 2018 · Penalty $1,250
Resolve - Class - 1
20180924
Aug 10, 2018
Resolve - Class - 1
Door monitor protection inoperative. cease use. contact [email protected] for reinspection.hole in cab floor. ventilation not covered.
Aug 10, 2018
Resolve - Class - 1
(c/u)05.a.10,02.l.10,100.l.11,cease use item door zone restrictor has been tampered with disabled and rendered inoperative.this is a safety device to ensure elevator passengers safety,repair restrictor and cont
Aug 10, 2018 · Penalty $1,250
Resolve - Class - 2
Top of car inspection inoperative
Aug 10, 2018
Resolve - Class - 2
97x10 the elevator in building out of service upon inspection the device is found to be out of service. repair and put back to service.
Jul 12, 2018
Resolve - Class - 2
52h10;02x10;67x10;99bb07:replace hoist ropes;inside car bell its not operative;communication)(phone) is not operative;provide one year test
Jul 5, 2017
Resolve - Class - 1
Cease use. 7x10,1h11,12x10,42g11,77b11,5m7,17h11,17d6. (7x)inoperative safety edge. (1h)replace switch unreadable fuses. (77b)provide 21" min toe guard. (5m)zone lock restroom. (17h/d)replace/secure where neede
Jun 30, 2017 · Penalty $1,000
Resolve - Class - 2
05h11,16j01,29b01,34p16,100b11,64b07. 05h11-door clutch retraction vane hitting rollers; 16j01-rollers hitting clutch; 29b01-doors not fully closing; 34p16:cannot access hoistway at the top landing; 64b07-devi
Sep 14, 2016 · Penalty $500
Resolve - Class - 2
05h11,16j01,34p16,64b07 05h11-door clutch retraction vane hitting rollers; 16j01-rollers hitting clutch; 34p16: cannot access hoistway fromt he top landing; 64b07-cannot read the device #tag.
Sep 14, 2016 · Penalty $500
Resolve - Class - 2
05h11,16j01,64b07. 05h11-door clutch retraction vane hitting rollers; 16j01-rollers hitting clutch; 64b07-device # is not readable.
Sep 14, 2016 · Penalty $500
Resolve - Class - 2
97x10 return this device to service.
Sep 14, 2016
Resolve - Class - 2
Sec: 28-304.7. 06h11,29h11,59o02,62i10. (06h)gate switch roller is worn; (29h)clutch vane retractor roller is worn out; (59o)dust on brake shoe; (62i)burnt marks on commutator.
Jun 13, 2016 · Penalty $1,300
Resolve - Class - 2
Sec: 28-304.7. 29h11,29k11,56h11. (29h)clutch retracting vane roller is worn; (29k)door motor chain is rusty; (56h)tach wheel is worn.
Jun 13, 2016 · Penalty $650
Resolve - Class - 2
Sec: 28-304.7. 100r07. the owner shall have a maintenance contract with an approved agency to perform elevator repair work & maintenance. provide a written contract w/ an approved agency.
Jun 13, 2016 · Penalty $400
Resolve - Class - 1
Sec: 28-304.7. cease use. (05b)door are closing too fast; (07x)safety edge doesnt work sometimes; (29h)clutch retracting vane roller is worn; (97r)provide a license maintenance company to maintain this device.
Jun 13, 2016 · Penalty $1,000
Resolve - Class - 2
Sec: 28-304.7. 100r07. the owner shall have a maintenance contract w/ an approved agency to perform elevator repair work & maintenance. provide a written contract w/ an approved agency.
Jun 13, 2016
Resolve - Class - 2
Sec: 28-304.7. 100r07. the owner shall have a maintenance contract w/ an approved agency to perform elevator repair work & maintenance. provide a written contract w/ an approved agency.
Jun 13, 2016 · Penalty $400
Resolve - Class - 2
Sec: 28-304.7. (62i)commutator is unevenly worn; (97r)the owner shall have a maintenance contract w/ an approved agency to perform elevator repair work & maintenance. provide a written contract w/ an approved a
Jun 13, 2016 · Penalty $650
Resolve - Class - 2
Sec: 28-304.7. 16l11,29h11. (16l)spirator on the 4th flr is making noise; (29h)clutch vane retracting roller is worn.
Jun 13, 2016 · Penalty $650
Resolve - Class - 2
Sec: 28-304.7. 52k11,52h11,97r07. (52k)hoist ropes are rusted; (52h)hoist ropes are worn; (97r)the owner shall have a maintenance contract w/ a licensed elevator company. provide a written contract w/ an approv
Jun 13, 2016 · Penalty $400
Resolve - Class - 2
97x10 device not working at time of inspection.
May 16, 2016 · Penalty $250
Resolve - Class - 2
05x10,32j01,67x10,99t15. 05x10-door restrictor not working: 32j01-elevator is making noise as it runs in the hoistway; 67x10-phone is not working; 99t15-cannot read the tag.
May 16, 2016 · Penalty $250
Resolve - Class - 2
B251. 56u15:brake maintenance tag not on this device (nyc 2016 requirement)
Jan 5, 2016 · Penalty $2,500
Resolve - Class - 2
B251. 56u15:brake maintenance tag is missing (nyc 2016 requirement.)
Jan 5, 2016 · Penalty $2,500
Resolve - Class - 2
B251. 56u15:brake maintenance tag is not on this device (nyc 2016 requirement.)
Jan 5, 2016
Resolve - Class - 2
B251. 56u15:brake maintenance tag is missing (nyc 2016 requirement).
Jan 5, 2016 · Penalty $2,500
Resolve - Class - 2
B251.56u15:brake maintenance tag is missing.
Jan 5, 2016 · Penalty $2,500
Resolve - Class - 2
B251.56:brake maintenance tag is missing.
Jan 5, 2016 · Penalty $2,500
Resolve
Complaints
- Elevator
Maintenance
Jun 25, 2014 · Apt BLDG
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Office building (O4)
- Year built
- 1969
- Floors
- 22
- Residential units
- —
- Building area
- 459,100 ft²
- Lot area
- 32,542 ft²
- Zoning
- C5-4
- Community board
- 302
- Council district
- 33
- Block / lot
- 266 / 1
- Assessed value
- $38,076,750
- Landmark / historic district
- No
Questions about 111 Livingston Street
Who owns 111 Livingston Street?
The owner of record in NYC Department of City Planning PLUTO data is 111 Livington LLC.
Does 111 Livingston Street have violations?
NYC HPD has no housing violations on record for this property.
Is 111 Livingston Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 111 Livingston Street built?
City records list 1969 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.