roofy

2501 Sedgwick Avenue

Bronx, NY 10468BBL 2-03237-0009Map

Owner of record: 2499 Sedgwick Development LLC

2501 Sedgwick Avenue is an elevator apartment building built in 2022 in Bronx, 10468. It has 113 residential units across 7 floors. The owner of record is 2499 Sedgwick Development LLC. HPD has recorded 28 housing violations here, most recently on September 16, 2026. 12 of the 28 most recent violations are still open. City tax records listed 113 rent-stabilized apartments here in 2024.

HPD violations
28
DOB violations
3
ECB violations
28
HPD complaints
27

What to know

Concern
3 open Class C

Immediately hazardous issues among recent violations are still open.

Watch
Last violation Sep 16, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
113
About 100% of the building's 113 apartments

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 28

  • C

    Abate the infestation consisting of roaches in the entire apartment located at apt 213, 2nd story, 1st apartment from north at east

    Sep 16, 2026 · Apt 213

    Open — Notice of issuance sent to tenant
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 213, 2nd story, 1st apartment from north at east

    Sep 16, 2026 · Apt 213

    Open — Civ14 mailed
  • A

    Properly repair the source and abate the evidence of a water leak at ceiling in the bathroom located at apt 213, 2nd story, 1st apartment from north at east

    Sep 16, 2026 · Apt 213

    Open — Civ14 mailed
  • A

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the bathroom located at apt 213, 2nd story, 1st apartment from north at east

    Sep 16, 2026 · Apt 213

    Open — Civ14 mailed
  • B

    Abate the infestation consisting of bedbugs in the entire apartment located at apt 213, 2nd story, 1st apartment from north at east

    Sep 16, 2026 · Apt 213

    Open — Civ14 mailed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling and all walls in the kitchen located at apt 203, 2nd story, 2nd apartment from south at west

    Sep 4, 2026 · Apt 203

    Open — Civ14 mailed
  • B

    Properly repair the source and abate the evidence of a water leak at ceiling and north wall in the 2nd room from east at north located at apt 203, 762nd story, 2nd apartment from south at west

    Sep 4, 2026 · Apt 203

    Open — Civ14 mailed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling and north wall in the 2nd room from east at north located at apt 203, 762nd story, 2nd apartment from south at west

    Sep 4, 2026 · Apt 203

    Open — Civ14 mailed
  • C

    Replace or repair the self-closing doors that is missing or defective hinges at door at compactor closet, 5th story

    Sep 4, 2026

    Closed — Violation closed
  • B

    Properly repair the source and abate the evidence of a water leak at ceiling in the kitchen located at apt 203, 2nd story, 2nd apartment from south at west

    Sep 4, 2026 · Apt 203

    Open — Civ14 mailed
Show 18 more ↓
  • B

    Properly repair the source and abate the evidence of a water leak at north wall in the bathroom located at apt 203, 2nd story, 2nd apartment from south at west

    Sep 4, 2026 · Apt 203

    Open — Civ14 mailed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at north wall in the bathroom located at apt 203, 2nd story, 2nd apartment from south at west

    Sep 4, 2026 · Apt 203

    Open — Civ14 mailed
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 604, 6th story, 2nd apartment from north at east

    Jun 29, 2026 · Apt 604

    Open — Not complied with
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 309, 3rd story, 4th apartment from west at north

    Jun 29, 2026 · Apt 309

    Closed — Violation closed
  • B

    Properly repair or replace the broken or defective window frame in the 2nd room from east located at apt 309, 3rd story, 8th apartment from south at west

    Jun 25, 2026 · Apt 309

    Closed — Violation closed
  • A

    M/d law abate the nuisance consisting of window stopper at west in the 2nd room from east located at apt 309, 3rd story, 8th apartment from south at west

    Jun 25, 2026 · Apt 309

    Closed — Violation closed
  • A

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the kitchenette located at apt 313, 3rd story, 1st apartment from north at east

    Feb 24, 2026 · Apt 313

    Closed — Violation dismissed
  • C

    Abate the infestation consisting of roaches in the entire apartment located at apt 313, 3rd story, 1st apartment from north at east

    Feb 24, 2026 · Apt 313

    Closed — Violation dismissed
  • B

    Properly repair the source and abate the evidence of a water leak above ceiling in the bathroom located at apt 313, 3rd story, 1st apartment from north at east

    Feb 24, 2026 · Apt 313

    Closed — Violation dismissed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the bathroom located at apt 313, 3rd story, 1st apartment from north at east

    Feb 24, 2026 · Apt 313

    Closed — Violation dismissed
  • A

    Properly repair the source and abate the evidence of a water leak above ceiling in the kitchenette located at apt 313, 3rd story, 1st apartment from north at east

    Feb 24, 2026 · Apt 313

    Closed — Violation dismissed
  • A

    Post and maintain a proper notice on wall of the entrance story in english and spanish on the availability of the agencys housing information guide. a sample notice can be found at www.nyc.gov/hpd. at public hall, 1st story

    Feb 24, 2026

    Closed — Violation dismissed
  • C

    Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system paper sign at public hall, 1st story

    Feb 24, 2026

    Closed — Violation dismissed
  • A

    Post a proper notice of smoke detector requirements, in a form approved by the commissioner, at or near the mailbox paper sign at public hall, 1st story

    Feb 24, 2026

    Closed — Violation dismissed
  • A

    Post sign on wall of entrance story bearing name, address including apartment number if any, and telephone number of superintendent, janitor or housekeeper. at public hall, 1st story

    Feb 24, 2026

    Closed — Violation dismissed
  • A

    Post and maintain a proper sign on wall of entrance story showing the registration number assigned by the department and the address of the building. at public hall, 1st story

    Feb 24, 2026

    Closed — Violation dismissed
  • A

    Post a proper notice of carbon monoxide detecting device requirements, in a form approved by commissioner, in a common area of a class a multiple dwelling near inspection certificate or provide notice to tenants in private dwellings paper sign

    Feb 24, 2026

    Closed — Violation dismissed
  • A

    Post, in a form approved by the commissioner, and maintain a notice in a common area of the building regarding the procedures that should be followed when a gas leak is suspected at public hall, 1st story

    Feb 24, 2026

    Closed — Violation dismissed

DOB building violations · 3

  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2024

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 10, 2024

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 3, 2024

    Dob violation - dismissed

ECB violations · 28

  • Class - 2

    Observed in basement compactor room a sprinkler head obstructed by the ceiling soffit. sprinkler piping not painted red, pvc waste lines under sinks on first floor and basement, and the first floor bathrooms la

    Dec 26, 2025

    Resolve
  • Class - 2

    Bc 3307.1 scope. observed construction debris on the street in from of jobsite @ exposure 1. when asked to see department of transportation(dot) permit for the use of contain on street, no permit was provided.

    Apr 9, 2024

    Resolve
  • Class - 1

    Proposed 7 story new building at 7th floor level closed jobsite. building approximately 8499 square feet, upon shouting at perimeter & banging at fence to alert watchperson and to verify compliance with code, n

    Sep 9, 2023 · Penalty $2,500

    Resolve
  • Class - 2

    At time of inspection on proposed 7 story nb closed jobsite. i observed at rear exposure-3 with inadequate cearance-(min 5 feet)-3307.2.1 on pedestrian walkway with fence, yudock & pole obstruction & missing bl

    Sep 9, 2023 · Penalty $2,400

    Resolve
  • Class - 2

    Failure to provide pedestrian protection at exposure # 1 and 3. job site is a 7 floor nb at 3rd floor level with no pedestrian protection.amend site safety plans to re-direct traffic to the other side of the st

    Jun 21, 2023 · Penalty $625

    Resolve
  • Class - 2

    Observed inadequate construction fence at exposure 3 of jobsite. the said fence is collapsing towards public and has an abundance of openings in it.maintain fence as per code

    Apr 24, 2023

    Resolve
  • Class - 1

    Observed cold form steel installed with blocking at cellar level of jobsite. upon review of the dob approved drawings it shows that the blocking is to have straps installed top and bottom of blocking which is n

    Apr 24, 2023 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to provided ramps on pedestrian walkways. upon inspection, observed at exposure 3 temporary pedestrian walkway without ramps on both side as per building code 3307.2.6 requirement 4 ramps. also requirem

    Mar 14, 2023

    Resolve
  • Class - 2

    At time of inspection, observed in multiple level inadequate fire extinguishers. as per building code 3303.7.2 fire extinguishers shall follow fire code. observed missing inspection tags, expire inspection tags

    Mar 14, 2023

    Resolve
  • Class - 1

    Failure to provide temporary hand rail on stairs. upon inspection observed at exposure 3 workers currently working on stairs. no handrails installed on stairs while work in progress. stairs are higher than 6 fe

    Mar 14, 2023

    Resolve
Show 18 more ↓
  • Class - 1

    Upon inspection, observed inadequate indoor storage of a 3 containers of flammable liquids. as per building code 3303.4.6 storage of this liquids shall follow fire code. this condition violates fire codes 3306.

    Mar 14, 2023 · Penalty $625

    Resolve
  • Class - 1

    Upon inspection observed workers on stairwell without any fall protection system. no guardrails, handrails or a safe anchored point provided. at first observed worker with no body harness, second time observed

    Mar 14, 2023 · Penalty $2,500

    Resolve
  • Class - 1

    At time of inspection, observed construction site open currently 3 levels high. at exposure 3 observed cmu approx. 30 feet high no overhead protection installed. as per site safety plan overhead protection is r

    Mar 14, 2023 · Penalty $2,500

    Resolve
  • Class - 1

    Bc2104.6 failure to provide masonry cmu block wall bracing.in accordance w/tms602/ac530.1/adce6sec3.3.as noted ato my isp@active jobsite observed@exp2 cmu block unbraced&about 100'l&over 8"(8.9") temp bracing s

    Oct 25, 2022 · Penalty $2,500

    Resolve
  • Class - 2

    Job site fence not maintained, expired permitrenew construction fence permit.

    Jul 12, 2022 · Penalty $500

    Resolve
  • Class - 1

    Retaining formwork wall approx 20 feet in height w/ makeshift connections w/out plans. no pre-construction survey.provide approved drawings for retaining formwork wall & pre-construction survey.

    Jul 12, 2022

    Resolve
  • Class - 2

    Work contrary to construction documents.at the time of my inspection,iobserved that the construction fence surrounding the jobsite was modified/enlarged at the corner of exp3 and 4 which constricted the access

    Dec 10, 2021 · Penalty $620

    Resolve
  • Class - 2

    Unsafe/unsuitable electrical equipment in use.at the time of my inspection,i observed 2 workers using separate arc welding equipment for soewalers at exp4.however the ground leads for both machines were frayed.

    Dec 10, 2021 · Penalty $400

    Resolve
  • Class - 1

    Failure to notify dob prior to commencement of earthwork/foundation work. at the time of my inspection,i observed that excavation & support of excavation(soe)work being done at exp#4. however,there was no evide

    Oct 19, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    Work contrary to construction documents. at the time of my inspection,i observed that the support of excavation(soe)were being done at exp#4did not conform to the approved/accepted drawings. 1)there was no vibr

    Oct 19, 2021 · Penalty $625

    Resolve
  • Class - 2

    Temporary construction equipment on site - expired permit. as noted:at time of inspection at active construction site observed permit #x00315735-i1-fn issued 01/28/21 expired 07/17/21.further research of dob re

    Sep 8, 2021

    Resolve
  • Class - 2

    Temporary construction equipment onsite expired permit "fence" at timeof inspection observed an construction site with temporary construction equipment "fence" expires 04/10/2021 and i also hold on dobnow.not r

    Apr 13, 2021 · Penalty $1,250

    Resolve
  • Class - 2

    Jobsite fence not constructed or maintained pursuant to subsection.at time of inspection i observed an construction site,during inspection noted:at exposure#4 missing fence.this creating hazardous condition to

    Apr 13, 2021 · Penalty $500

    Resolve
  • Class - 2

    Failure to maintain building walls or appurtenances. the front porch ceiling has collapsed & the remaining wooden ceiling is deteriorating &in danger of collapsing. the (sofit) at roof is deteriorating and

    Jan 25, 2012 · Penalty $500

    Resolve
  • Hazardous

    Failure to maintain exterior bldg walls defect noted brick garage are cracked spalling throut parapet walls wood shacks erected at rear all in dis repair all in danger of collapsing on to baily are as stated

    Sep 4, 2003 · Penalty $2,000

    Resolve
  • Non-hazardous

    Illegal use in a residential district. illegal use- dead storage of approx 10 motor vehicles. also auto repair in garage. residential zone r6- remedy: discontinue illegal use.

    Jul 14, 2003 · Penalty $480

    Resolve
  • Non-hazardous

    Work without permit: work noted: constructed wooden structures out of plywood, 2x4's for franicks addedd wood burning stove for heat also built strutures on edge of incline at rear of property- in danger of col

    Jul 14, 2003 · Penalty $800

    Resolve
  • Hazardous

    Failure to maintain exterior build walls: defects noted: brick garages are cracked & spalling throut parapit walls. wood shacks erected are in disrepair & are illegal structures as stated in cosntruction with v

    Jul 14, 2003 · Penalty $800

    Resolve

Complaints

  • Unsanitary condition

    Pests

    Sep 14, 2026 · Apt 213

    Close
  • Water leak

    Damp spot

    Sep 14, 2026 · Apt 213

    Close
  • Unsanitary condition

    Pests

    Sep 14, 2026 · Apt 213

    Close
  • Unsanitary condition

    Pests

    Sep 14, 2026 · Apt 213

    Close
  • Water leak

    Slow leak

    Sep 4, 2026 · Apt 203

    Close
  • Plumbing

    Radiator

    Sep 4, 2026 · Apt 203

    Close
  • Unsanitary condition

    Pests

    Sep 4, 2026 · Apt 203

    Close
  • Paint/plaster

    Wall

    Sep 4, 2026 · Apt 203

    Close
  • Paint/plaster

    Wall

    Sep 4, 2026 · Apt 203

    Close
  • Electric

    Wiring

    Aug 20, 2026 · Apt 508

    Close
Show 17 more ↓
  • Paint/plaster

    Wall

    Aug 20, 2026 · Apt 508

    Close
  • Unsanitary condition

    Pests

    Aug 20, 2026 · Apt 508

    Close
  • Unsanitary condition

    Pests

    Aug 20, 2026 · Apt 508

    Close
  • Door/window

    Window frame

    Jun 26, 2026 · Apt 309

    Close
  • Unsanitary condition

    Pests

    Jun 23, 2026 · Apt 604

    Close
  • Door/window

    Window frame

    Jun 22, 2026 · Apt 309

    Close
  • Unsanitary condition

    Garbage/recycling storage

    Jun 22, 2026 · Apt BLDG

    Close
  • Unsanitary condition

    Pests

    Jun 22, 2026 · Apt 309

    Close
  • Water leak

    Heavy flow

    Feb 23, 2026 · Apt 313

    Close
  • Paint/plaster

    Ceiling

    Feb 23, 2026 · Apt 313

    Close
  • Heat/hot water

    Entire building

    Jan 29, 2026 · Apt BLDG

    Close
  • Water leak

    Heavy flow

    Jan 28, 2026 · Apt 313

    Close
  • Heat/hot water

    Entire building

    Jan 26, 2026 · Apt 508

    Close
  • Water leak

    Heavy flow

    Nov 6, 2025 · Apt 312

    Close
  • Heat/hot water

    Entire building

    Jul 21, 2025 · Apt BLDG

    Close
  • Unsanitary condition

    Pests

    Jul 20, 2025 · Apt 1

    Close
  • Electric

    No lighting

    Apr 25, 2025 · Apt 510

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D7)
Year built
2022
Floors
7
Residential units
113
Building area
120,781 ft²
Lot area
31,767 ft²
Zoning
R6
Community board
207
Council district
14
Block / lot
3237 / 9
Assessed value
$8,645,400
Landmark / historic district
No

HPD registration #229075, last renewed Aug 25, 2025.

Questions about 2501 Sedgwick Avenue

Who owns 2501 Sedgwick Avenue?

The owner of record in NYC Department of City Planning PLUTO data is 2499 Sedgwick Development LLC.

Does 2501 Sedgwick Avenue have violations?

Yes. NYC HPD has recorded 28 housing violations at this property.

Is 2501 Sedgwick Avenue rent stabilized?

NYC Department of Finance tax bills listed 113 rent-stabilized units here in 2024 (about 100% of its 113 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 2501 Sedgwick Avenue built?

City records list 2022 as the year it was built.

How many apartments are in 2501 Sedgwick Avenue?

It has 113 residential units and 115 units in total.