roofy

500 West 42 Street

Manhattan, NY 10036BBL 1-01070-7501Map

Owner of record: 500 West 42nd St Hsg Develpmt Fd Co

500 West 42 Street is a condominium built in 2001 in Manhattan, 10036. It has 25 residential units across 6 floors. The owner of record is 500 West 42nd St Hsg Develpmt Fd Co. HPD has recorded 311 housing violations here, most recently on September 22, 2026. 9 of the 50 most recent violations are still open. City tax records listed 91 rent-stabilized apartments here in 2024.

HPD violations
311
DOB violations
20
ECB violations
27
HPD complaints
560

What to know

Concern
3 open Class C

Immediately hazardous issues among recent violations are still open.

Watch
Last violation Sep 22, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
91
About 100% of the building's 25 apartments

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 311

  • A

    Properly repair or replace the broken or defective mechanical water-stopper at wash basin in the bathroom located at apt 3m, 3rd story, 3rd apartment from east at south

    Sep 22, 2026 · Apt 3M

    Open — Nov sent out
  • A

    Properly repair with similar material the broken or defective porcelain enamel finish by method of reglazing at bathtub in the bathroom located at apt 3m, 3rd story, 3rd apartment from east at south

    Sep 22, 2026 · Apt 3M

    Open — Nov sent out
  • C

    M/d law abate the nuisance consisting of refrigerator at cellar story at public hall

    Jun 13, 2026

    Closed — Violation dismissed
  • B

    Remove all encumbrances consisting of gas range at cellar story at public hall

    Jun 13, 2026

    Closed — Violation dismissed
  • C

    Replace or repair the self-closing doors that is missing or defective hinges at roof bulkhead door at 6th story

    Mar 3, 2026

    Closed — Violation closed
  • C

    Replace or repair the self-closing doors that is missing or defective latch set at fire stairs door ''''a'''' at 4th story public hallway

    Mar 3, 2026

    Closed — Violation closed
  • B

    Properly repair or replace the broken or defective latch set at fire stairs door ''''a'''' at 4th story public hallway

    Mar 3, 2026

    Closed — Violation dismissed
  • C

    Provide an adequate supply of heat for the apartment in the entire apartment located at apt 2h, 2nd story, 1st apartment from west at north

    Feb 1, 2026 · Apt 2H

    Closed — Violation dismissed
  • C

    Provide ready access to buildings heating system door locked at basement at boiler room

    Feb 1, 2026

    Closed — Violation dismissed
  • C

    Replace or repair the self-closing doors that is missing or defective fire door (hinges) at laundry room, 530th story

    Jan 20, 2026

    Closed — Violation closed
Show 40 more ↓
  • C

    Replace or repair the self-closing doors that is missing or defective fire door (stairs 'a') at 1st public hall bulkhead from north

    Jan 20, 2026

    Closed — Violation closed
  • A

    Repair the leaky and/or defective faucets at wash basin in the bathroom located at apt 2n, 2nd story, 2nd apartment from east at south

    Jan 20, 2026 · Apt 2N

    Closed — Violation dismissed
  • B

    Properly repair or replace the broken or defective light fixture at ceiling in the bathroom located at apt 4m, 4th story, 3rd apartment from east at south

    Jan 20, 2026 · Apt 4M

    Closed — Violation dismissed
  • B

    Properly repair or replace the broken or defective mechanical ventilation in the bathroom located at apt 5k, 5th story, apartment at south

    Jan 20, 2026 · Apt 5K

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective rubber gasket at refrigrator in the kitchenette located at apt 6l, 6th story, 4th apartment from east at south

    Jan 20, 2026 · Apt 6L

    Closed — Violation dismissed
  • B

    Properly repair or replace the broken or defective mortise door lock in the entrance located at apt 2n, 2nd story, 2nd apartment from east at south

    Jan 20, 2026 · Apt 2N

    Closed — Violation dismissed
  • B

    Properly repair or replace the broken or defective light fixture at ceiling in the kitchenette located at apt 3k, 3rd story, 5th apartment from east at south

    Jan 20, 2026 · Apt 3K

    Closed — Violation dismissed
  • A

    Properly repair or replace the broken or defective caulking around window seal in the 1st room from north located at b-room 5f2, 5th story, 2nd b-room from west at north

    Jan 20, 2026 · Apt 5F2

    Open — Invalid certification
  • B

    Repair, replace or provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules defective in the room located at b-room 6i2, 6th story, 1st b-room from west at north

    Nov 6, 2025 · Apt 6I2

    Closed — Violation closed
  • B

    Repair, replace or provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations defective in the room located at b-room 6i2, 6th story, 1st b-room from west at north

    Nov 6, 2025 · Apt 6I2

    Closed — Violation closed
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 2l, 2nd story, 4th apartment from east at south

    Aug 1, 2025 · Apt 2L

    Open — Defect letter issued
  • C

    Repair the broken or defective plastered surfaces and paint in a uniform color approx 8 sqft unkeyed plaster at ceiling in the 2nd room from north located at apt 2l, 2nd story, 4th apartment from east at south

    Aug 1, 2025 · Apt 2L

    Closed — Violation dismissed
  • C

    Replace or repair the self-closing doors that is missing or defective latch set at fire stairs door ''a'' at public hall, 4th story

    Jun 10, 2025

    Closed — Violation closed
  • B

    Properly repair or replace the broken or defective latch set at fire stairs door ''a'' at public hall, 4th story

    Jun 10, 2025

    Closed — Violation closed
  • C

    Replace or repair the self-closing doors that is missing or defective hinge at public hall stairs, 1st story

    May 28, 2025

    Closed — Violation closed
  • B

    Abate the nuisance consisting of excessive storage of material house hold items located at apt 3j2, 3rd story, 5th apartment from east at south , section ''suite 2''

    Apr 7, 2025 · Apt 3J2

    Closed — Violation closed
  • B

    Repair or replace the smoke detector missing in the entrance located at apt 3j2, 3rd story, 5th apartment from east at south

    Apr 7, 2025 · Apt 3J2

    Closed — Violation dismissed
  • C

    Remove device preventing door from being self-closing (door sweep) in the entrance located at apt 3j2, 3rd story, 5th apartment from east at south

    Apr 7, 2025 · Apt 3J2

    Closed — Violation closed
  • A

    Properly repair or replace the broken or defective lighting fixtures at ceiling in the kitchen located at apt 6g, 6th story, 3rd apartment from west at north

    Mar 7, 2025 · Apt 6G

    Closed — Violation closed
  • C

    Install the missing or repair/replace the defective window guard(s) in accordance with the specifications of the new york city health code section 24 rcny chapter 12. wg to install = 0; wg to replace = 0; wg to repair = 1; [ air conditioner not properly secure with one way screws ] in the entire apartment located at apt 5e, 5th story, 5th apartment from west at north

    Mar 7, 2025 · Apt 5E

    Open — Invalid certification
  • A

    Paint with light colored paint to the satisfaction of this department ceiling and all walls in the entire apartment located at apt 3o, 3rd story, 1st apartment from east at south

    Mar 7, 2025 · Apt 3O

    Closed — Violation closed
  • B

    Repair or replace the carbon monoxide detecting device(s). missing device in the entire apartment located at apt 6f1, 6th story, 4th apartment from west at north

    Mar 7, 2025 · Apt 6F1

    Closed — Violation dismissed
  • C

    Replace or repair the self-closing doors that is missing or defective hinges at door in the entrance located at apt 6f1, 6th story, 4th apartment from west at north

    Mar 7, 2025 · Apt 6F1

    Closed — Violation closed
  • A

    Reset, so as to secure a proper and tight connection, the water closet bowl in the bathroom located at apt 6g, 6th story, 3rd apartment from west at north

    Mar 7, 2025 · Apt 6G

    Closed — Violation dismissed
  • B

    Repair or replace the smoke detector defective device in the entire apartment located at apt 6g, 6th story, 3rd apartment from west at north

    Mar 7, 2025 · Apt 6G

    Closed — Violation dismissed
  • B

    Repair or replace the carbon monoxide detecting device(s). defective device in the entire apartment located at apt 6g, 6th story, 3rd apartment from west at north

    Mar 7, 2025 · Apt 6G

    Closed — Violation dismissed
  • B

    Abate the nuisance consisting of excessive storage of material in the entire apartment located at apt 6g, 6th story, 3rd apartment from west at north

    Mar 7, 2025 · Apt 6G

    Closed — Violation closed
  • B

    Repair the broken or defective connection at waste drain pipe at sink in the kitchen located at apt 6g, 6th story, 3rd apartment from west at north

    Mar 7, 2025 · Apt 6G

    Closed — Violation dismissed
  • B

    Repair the broken or defective connection at waste drain pipe at sink in the kitchen located at apt 6e, 6th story, 5th apartment from west at north

    Mar 7, 2025 · Apt 6E

    Closed — Violation dismissed
  • A

    Repair the leaky and/or defective faucets at sink in the kitchen located at apt 6e, 6th story, 5th apartment from west at north

    Mar 7, 2025 · Apt 6E

    Open — Invalid certification
  • B

    Repair the leaky and/or defective faucets at wash basin in the 2nd bathroom from east located at apt 6e, 6th story, 5th apartment from west at north

    Mar 7, 2025 · Apt 6E

    Closed — Violation dismissed
  • B

    Repair the leaky and/or defective faucets at wash basin in the 1st bathroom from east located at apt 6e, 6th story, 5th apartment from west at north

    Mar 7, 2025 · Apt 6E

    Closed — Violation dismissed
  • B

    Repair or replace the carbon monoxide detecting device(s). missing device in the entire apartment located at apt 6e, 6th story, 5th apartment from west at north

    Mar 7, 2025 · Apt 6E

    Closed — Violation dismissed
  • C

    Install the missing or repair/replace the defective window guard(s) in accordance with the specifications of the new york city health code section 24 rcny chapter 12. wg to install = 0; wg to replace = 0; wg to repair = 2; [ air conditioner not properly secure ] in the entire apartment located at apt 6e, 6th story, 5th apartment from west at north

    Mar 7, 2025 · Apt 6E

    Open — Invalid certification
  • B

    Repair the flushing apparatus and maintain same so as to flush effectively the water closet in the bathroom located at apt 6l, 6th story, 4th apartment from east at south

    Mar 7, 2025 · Apt 6L

    Closed — Violation closed
  • A

    Properly repair with similar material the broken or defective wood floor [ walk area ] in the foyer located at apt 5k, 5th story, 5th apartment from east at south

    Mar 7, 2025 · Apt 5K

    Open — Not complied with
  • A

    Refit entrance door in the bathroom located at apt 5k, 5th story, 5th apartment from east at south

    Mar 7, 2025 · Apt 5K

    Open — Not complied with
  • C

    Replace or repair the self-closing doors that is missing or defective hinges at door in the entrance located at apt 6g, 6th story, 3rd apartment from west at north

    Mar 7, 2025 · Apt 6G

    Closed — Violation closed
  • A

    Paint with light colored paint to the satisfaction of this department ceiling and all walls in the entire apartment located at apt 3h, 3rd story, 2nd apartment from west at north

    Mar 7, 2025 · Apt 3H

    Closed — Violation closed
  • B

    Properly repair the source and abate the evidence of a water leak at ceiling and north wall in the foyer located at apt 4l, 4th story, 4th apartment from east at south

    Feb 4, 2025 · Apt 4L

    Closed — Violation dismissed

DOB building violations · 20

  • Low pressure boiler boiler required

    Violation issued-failure to file 2024 external low pressure inspection

    Nov 14, 2025

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2024 external low pressure inspection

    Nov 14, 2025

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 4, 2023

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Feb 2, 2022

    Dob violation - dismissed
  • Failure to post energy grade/score none

    Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3

    Dec 1, 2021

    Dob violation - dismissed
  • Failure to post energy grade/score none

    Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3

    Apr 29, 2021

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 28, 2020

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 5, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 5, 2020

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 26, 2019

    Dob violation - active
Show 10 more ↓
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 2, 2019

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2019

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 5, 2013

    Dob violation - resolved
  • Construction other optional

    Inadequate details on approved plans for all work regarding existing brick structure and vaults at sidewalk of exposure! (w 42 st) and expo sure 2 (existing 500 w 42 st) approx 20'x20' within lot shoring plans show shoring of excavation beyond this structure to property line stru cture and vaults not shown on plans remedy: amend plans and/or provide

    Apr 1, 2009

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 1, 2009

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 1, 2009

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 1, 2009

    Dob violation - dismissed
  • Construction other optional

    Miscellaneous violations. design fails to consider the influence of ne w footings on adjoining footings at different elevations remedy: stop all work. comply with notice of violation. call sep 212 442-1698. before starting any work

    Dec 17, 2008

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 21, 2008

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 3, 2008

    Dob violation - dismissed

ECB violations · 27

  • Class - 2

    Found peerless(model# gm 08 sprk) gas fired boilers in cellar not registered, maintain boiler; correct violating condition submit certifcate of correction

    Jun 13, 2024 · Penalty $655

    Active
  • Class - 2

    As per hmc section of law 27-2033; key access for heating system area lock. failure to provide keys to heating system area lock.

    Nov 1, 2023 · Penalty $625

    Active
  • Class - 2

    As per one slantfin heating boiler. modules 3, 4, 5, and 6 not operating to provide heat to the building-pressure range on compound gages not as per code standards for boiler pressure vessels.

    Oct 17, 2023 · Penalty $625

    Active
  • Class - 2

    #2 motorized combustion air louver defective/#3module defective/illegal module isolation valves installed/hw temperature gauge corroded/hw storage tank manhole corroded;correct violation and submit the certific

    Mar 27, 2023 · Penalty $3,125

    Active
  • Class - 2

    Motorized combustion air louver defective/temperature gauge at outlet manifold defective/#2 module return pipe leaking/illegal module isolation valves installed/#2 heating circulator pipe leaking;correct violat

    Mar 27, 2023 · Penalty $3,125

    Active
  • Class - 1

    D l m defective up on inspection dlm is not working . repair . re inspection required.

    Jul 12, 2022 · Penalty $1,280

    Resolve
  • Class - 2

    Boiler #3 on boiler bank #1 leaking

    Jul 11, 2022 · Penalty $655

    Active
  • Class - 1

    D l m defective , repair , and re inspection required.

    Mar 11, 2022 · Penalty $1,280

    Resolve
  • Class - 2

    Failure to comply with the commissioner's order contained in summons/violation#35581821n issued on 11/12/21 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01.for b102:failure to main

    Feb 17, 2022 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to maintain bldg in a code compliant manner.noted:front facadesection of decorative painted black plywood above entrance door approx7' has fallen to ground.additionally,further inspection has revealed

    Nov 12, 2021 · Penalty $6,250

    Active
Show 17 more ↓
  • Class - 1

    No door lock monitoring installed in this controller as mandated by 3.10.12 of appendix k3 of the 2014 nycbc. remedy; install dlm and, perform and file test with nycdob.

    Aug 4, 2020 · Penalty $1,250

    Active
  • Class - 2

    39m07,16m11,59m07,68m07,70o07,45b13. (39-m-07) car top light missing. provide (16-h-11). replace om roller (worn) (59-m-07) machine broke top missing, provide. (68-m-07)maintenacnce mcp missing, provide (70-o-0

    Mar 21, 2016 · Penalty $250

    Resolve
  • Class - 2

    Altered/changed bldg occupied w/o a valid c of o. noted: c of o #104393513t012 has been expired on 3-2-15. remedy: obtain valid c of o & or discontinue illegal occupancy.

    Mar 2, 2016 · Penalty $500

    Resolve
  • Class - 2

    44r05 - traction sheave was installed w/o permit being obtained and application being filed. rmdy: file application and () permit for work and schedule test appointment with nycdob at 212-393-2488.

    Oct 1, 2015 · Penalty $500

    Resolve
  • Class - 2

    Provision of law 27-1021 failure to provide required sign on sidewalk shed. noted: site in excavated with sheeting & shoring. at time of inspection i did not observe & sidewalk shed erected with no visible sign

    May 20, 2009 · Penalty $400

    Resolve
  • Class - 1

    Provision of law 27-1032 failure to protect and adjoining footing or foundation affected by excavation with sheeting & shoring has an exisiting partiall swo 121708cid0401da no work vault area exp #1 pending pla

    May 20, 2009 · Penalty $1,600

    Resolve
  • Class - 2

    Provision of alw miscellaneous violations failure to provide required lot line construction fence. contractors failed to provide 8ft high lot line construction fence at exp. 3 at time of inspection there was a

    Apr 18, 2009 · Penalty $800

    Resolve
  • Class - 2

    Failure to provide approved/accepted plans at job site at time of inspection. contractor excavated site to depths of approx 10 to 12 feet &installed sheet piling to support excavation. contractor does not have

    Dec 18, 2008 · Penalty $2,500

    Resolve
  • Class - 2

    Sec. 3309.3 misc violations. failure to perform inspection & document conditions of existing structures adjoining a construction or demolition site in a pre construction survey. contractor demolished building

    Dec 18, 2008 · Penalty $4,000

    Resolve
  • Class - 2

    Failure to safeguard all persons & property affected by construction operattions. "no smoking" signs not posted or inadequate in violation of nyc fire code 1404.1 & fc310. remedy: stop all work. safeguard publi

    Dec 18, 2008 · Penalty $6,000

    Resolve
  • Class - 2

    Sec. 27-1032b,3304.4.4 misc violations. failure to provide 3 foot 6 inch guardrail or solid enclosure around open & accessible sides of excavation. contractor failed to install guardrail or protection at exposu

    Dec 18, 2008 · Penalty $800

    Resolve
  • Class - 2

    Sec. 27-195,3304.3.1 misc violations. failure to notify department of building w/i 24-48 hrs of the start of excavation. contractor obtained confirmation #103169 in compliance with rule 52 requirements,but decl

    Dec 18, 2008 · Penalty $4,000

    Resolve
  • Class - 2

    Sec. 27-132,1704.1 misc violations. failure to file a special inspection statement of responsibility prior to permit issuance & prior to start of work under special inspection requirement. contractor/owner has

    Dec 18, 2008 · Penalty $800

    Resolve
  • Class - 1

    Sec bc3313.1 27-1069 storage installation connection ventilation and use of all volatile flammable oils flammable and combustible mixtures compressed gasses and other hazardous materials shall comply w/ the nyc

    Dec 16, 2008 · Penalty $1,600

    Resolve
  • Class - 2

    Failure to safeguard all persons and property affected by constructionoperation note at the time of insp on active construction site work in progress on foundation w/ no construction fence to the rear of site m

    Dec 16, 2008 · Penalty $1,200

    Resolve
  • Class - 1

    Sec bc1001.1 27-357 failure to provide required means of egress note at the time of insp on active construction site observed approx 7' to 8' deep hole excavated for foundation of new bldg only one ramp has bee

    Dec 16, 2008 · Penalty $1,600

    Resolve
  • Hazardous

    Side walk shed does not meet building code specifications. a) no lightc) no side deck enclosure remdy : conform shed to building code specification

    Aug 6, 2003 · Penalty $2,000

    Resolve

Complaints

  • Plumbing

    Basin/sink

    Aug 29, 2026 · Apt 3M

    Close
  • Plumbing

    Bathtub/shower

    Aug 29, 2026 · Apt 3M

    Close
  • Door/window

    Window frame

    Jul 21, 2026 · Apt 2N

    Close
  • Plumbing

    Bathtub/shower

    Jul 21, 2026 · Apt 2N

    Close
  • Unsanitary condition

    Sewage

    Apr 29, 2026 · Apt 4I2

    Close
  • Door/window

    Door

    Feb 25, 2026 · Apt 6L

    Close
  • Door/window

    Door

    Feb 25, 2026 · Apt 6L

    Close
  • General

    Cooking gas

    Feb 21, 2026 · Apt 6L

    Close
  • Door/window

    Door

    Feb 21, 2026 · Apt 6L

    Close
  • Appliance

    Electric/gas range

    Feb 10, 2026 · Apt 6L

    Close
Show 40 more ↓
  • Heat/hot water

    Entire building

    Feb 8, 2026 · Apt 3E

    Close
  • Heat/hot water

    Apartment only

    Jan 30, 2026 · Apt 3H

    Close
  • Heat/hot water

    Apartment only

    Jan 30, 2026 · Apt 3M

    Close
  • Heat/hot water

    Apartment only

    Jan 28, 2026 · Apt 2H

    Close
  • Plumbing

    Bathtub/shower

    Jan 22, 2026 · Apt 5H

    Close
  • Unsanitary condition

    Pests

    Jan 22, 2026 · Apt 5H

    Close
  • Appliance

    Refrigerator

    Jan 12, 2026 · Apt 6L

    Close
  • Paint/plaster

    Wall

    Jan 6, 2026 · Apt 3H

    Close
  • Appliance

    Refrigerator

    Nov 25, 2025 · Apt 6L

    Close
  • Heat/hot water

    Entire building

    Nov 12, 2025 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Nov 11, 2025 · Apt 3B

    Close
  • Appliance

    Electric/gas range

    Oct 28, 2025 · Apt 6E

    Close
  • Appliance

    Refrigerator

    Sep 26, 2025 · Apt 6L

    Close
  • Appliance

    Electric/gas range

    Sep 26, 2025 · Apt 6E

    Close
  • Paint/plaster

    Door/frame

    Sep 23, 2025 · Apt 3H

    Close
  • Heat/hot water

    Entire building

    Jul 15, 2025 · Apt 5F

    Close
  • Safety

    Smoke detector

    Jul 9, 2025 · Apt 6E

    Close
  • Paint/plaster

    Door/frame

    Jul 7, 2025 · Apt 3H

    Close
  • Appliance

    Electric/gas range

    Jul 7, 2025 · Apt 3H

    Close
  • Paint/plaster

    Door/frame

    Jun 24, 2025 · Apt 3H

    Close
  • Paint/plaster

    Wall

    Jun 24, 2025 · Apt 3H

    Close
  • Appliance

    Electric/gas range

    Jun 24, 2025 · Apt 3H

    Close
  • Appliance

    Electric/gas range

    Jun 19, 2025 · Apt 3H

    Close
  • Paint/plaster

    Door/frame

    May 15, 2025 · Apt 3H

    Close
  • Appliance

    Electric/gas range

    May 15, 2025 · Apt 3H

    Close
  • Plumbing

    Basin/sink

    Feb 26, 2025 · Apt 6L

    Close
  • Plumbing

    Toilet

    Feb 26, 2025 · Apt 6L

    Close
  • Appliance

    Electric/gas range

    Feb 26, 2025 · Apt 4J1

    Close
  • Heat/hot water

    Apartment only

    Feb 6, 2025 · Apt 6L

    Close
  • Plumbing

    Basin/sink

    Feb 6, 2025 · Apt 6L

    Close
  • Plumbing

    Basin/sink

    Feb 6, 2025 · Apt 6L

    Close
  • Plumbing

    Toilet

    Feb 6, 2025 · Apt 6L

    Close
  • Heat/hot water

    Apartment only

    Jan 23, 2025 · Apt 6L

    Close
  • Heat/hot water

    Entire building

    Jan 16, 2025 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Jan 14, 2025 · Apt 2F

    Close
  • Unsanitary condition

    Mold

    Jan 13, 2025 · Apt 4L

    Close
  • Unsanitary condition

    Pests

    Jan 8, 2025 · Apt 3O

    Close
  • Plumbing

    Radiator

    Jan 6, 2025 · Apt 5J1

    Close
  • Heat/hot water

    Apartment only

    Jan 4, 2025 · Apt 5J1

    Close
  • Heat/hot water

    Apartment only

    Jan 3, 2025 · Apt 5J1

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Condominium (RM)
Year built
2001
Floors
6
Residential units
25
Building area
27,410 ft²
Lot area
4,108 ft²
Zoning
C6-4
Community board
104
Council district
3
Block / lot
1070 / 7501
Assessed value
$6,317,100
Landmark / historic district
No

HPD registration #107366, last renewed Aug 29, 2025.

Questions about 500 West 42 Street

Who owns 500 West 42 Street?

The owner of record in NYC Department of City Planning PLUTO data is 500 West 42nd St Hsg Develpmt Fd Co.

Does 500 West 42 Street have violations?

Yes. NYC HPD has recorded 311 housing violations at this property.

Is 500 West 42 Street rent stabilized?

NYC Department of Finance tax bills listed 91 rent-stabilized units here in 2024 (about 100% of its 25 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 500 West 42 Street built?

City records list 2001 as the year it was built.

How many apartments are in 500 West 42 Street?

It has 25 residential units and 26 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.