roofy

9-02 38 Avenue

Queens, NY 11101BBL 4-00475-0030Map

Owner of record: Reit 38 LLC

9-02 38 Avenue is a hotel built in 2015 in Queens, 11101. It has 1 residential unit across 13 floors. The owner of record is Reit 38 LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
8
ECB violations
21
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 8

  • No report and / or late filing (facade) facade required

    Failed to file fisp cycle 9a technical report by 02/21/2022

    Feb 22, 2022

    Dob violation - active
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    May 16, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    May 16, 2018

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Feb 7, 2018

    Dob violation - dismissed
  • Construction other optional

    C-construction other optional

    Aug 28, 2017

    Vp*-violation unserved ecb- dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jun 29, 2016

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 7, 2015

    Dob violation - dismissed

ECB violations · 21

  • Class - 2

    Failure to submit acceptable required cycle9a report of critical exam documenting condition of exterior wall&appurtenances required by 28-302.4 for control918220.submit acceptable required technical report

    Dec 9, 2022

    Resolve
  • Class - 1

    I observed on the roof area where the 2 gravity tanks are installed. inside the 2 tanks unapproved material installed a bag pvc liners, which is prohibited. gravity tanks shall comply with nfpa 22, building cod

    Apr 12, 2021 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to designate site safety manager. at time of inspection on a active job site of a 13 sty bldg,i observed to see the ssn/ssc logs. current ssm/ssc was not recorded on the log book that was taking over,ss

    Feb 15, 2018 · Penalty $1,600

    Resolve
  • Class - 1

    Sec. 3303.12.2 hoist not in state of readiness. at time of inspection on a active job site of a 13 sty bldg,observed that hoist permit was expired since 2-1-18. inspection date 2-15-18 upon request for new perm

    Feb 15, 2018 · Penalty $1,600

    Resolve
  • Class - 1

    Bc3307.2 walkway. at time of inspection observed temporary walkway not maintained at 5.0 creating a dangerous walking condition for pedestrians. public must walk in street creating potential of being hit by veh

    Jan 18, 2018 · Penalty $4,000

    Resolve
  • Class - 1

    Failure to adequately designate site safety coordinator. at time of inspection observed designated ssm had not been on site for months,instead ssc#2377 zak ettamymy luis m engautegui #2339 & chaudhry m javid #

    Nov 14, 2017 · Penalty $25,000

    Resolve
  • Class - 1

    Sec. 3301.7 design drawings. at time of inspection observed elev shaft platform at all floors. when i requested design drawings for platforms none were provided. stop all work at elevator shaft partial stop wor

    Aug 28, 2017 · Penalty $1,600

    Resolve
  • Class - 1

    Guardrails. failure to maintain adequate guardrail system at elevator shaft. observed toe boards at least 2" off floor level also observed either center rail missing top rail missing or net not secured & creati

    Aug 28, 2017

    Resolve
  • Class - 2

    Housekeeping observed debris in hoist at 11th fl,12th fl & 8th fl piled more than 3'-0"high debris consisted of insulation sheetrock,metal studs,garbage bags. remedy: maintain housekeeping.

    May 10, 2017

    Resolve
  • Class - 1

    Work does not conform to approved construction document and/or approved amendments. as noted: at time of inspection on an active construction she observed 1-steel w12 beams supporting concrete floor (1st floor)

    Jun 30, 2016 · Penalty $5,000

    Resolve
Show 11 more ↓
  • Class - 1

    Work does not conform to approved construction documents and/or appro ved amendments: noted: at time of insepction of 13 story steel frame new building has built to the height o fapprx 40-50 feet,with no prot

    Mar 29, 2016 · Penalty $5,000

    Resolve
  • Class - 2

    Bc3303p obstruction of sidewalk and streed/sidewalk closing. w/o dot permit at time of inspection the following was observed. contractor has installed 8'high construction fence and barriers on 39 street and

    Mar 29, 2016 · Penalty $4,000

    Resolve
  • Class - 2

    Water accumulation.@ time of inspection of 13 story bldg under construction,@ foundation phase has approx 6" to 8" inches of water collectedon site,water appeared (stagnate)rem (pung) all water out of excavatio

    Jul 29, 2015 · Penalty $4,000

    Resolve
  • Class - 2

    28-110.1 osha 10.noted @ time of inspection of 13 story preposed steelframing bldg has one (washer) w/ no osha canel.only copy,which cant beverified in field.rem discontinue work,or obtain osha level.

    Jul 29, 2015 · Penalty $4,000

    Resolve
  • Class - 1

    Failure to have site coordinator present as required note at time of inspection. active job site excavation phase workers on site not site coordinator prsent. stop all work entire site except to provide ssc.

    Jul 8, 2015 · Penalty $12,000

    Resolve
  • Class - 2

    Work does not conform to approved construction documents &/or approvedamendments. at time of inspection observed active jobsite. at exp#1 along 38 avenie observe. traffic barricades extended for the entire leng

    May 26, 2015 · Penalty $250

    Resolve
  • Class - 2

    Sec. 3301.3 site safety managers,coordiators & superintended of construction. at time of inspection observed active jobsite. site safety-romana allegrin: #2106 (falsing)/states she has been on the site since

    May 26, 2015 · Penalty $400

    Resolve
  • Class - 1

    Failure to safeguard all persons & property affected by construction operations. at time of inspection observed active jobsite,observed welding equiptment confected to compressed gas cylinders,said cylinders

    May 26, 2015 · Penalty $12,000

    Resolve
  • Class - 2

    1704.1 special inspectors/inspection not on site.noted:job #420875333.designated controlled inspector not on site when contractor is performing any of the following underpinning,sheeting,shoring,bracing,sheet p

    May 7, 2015 · Penalty $830

    Resolve
  • Class - 1

    Work w/o permit "electrical permit" note observed temporary power beensupply to construction trailer at site from 9-10 38 avenue w/o obtaining a permit as per dob records "10:00 am". stop all use of electrical

    Mar 26, 2015 · Penalty $1,630

    Resolve
  • Class - 2

    Failure to provide approve/accepted plans at hte jobsite. plans for the support of excavation are inadequate. and does not detail the type of footing to be underpinned at exp3. the sequence of underpinning is

    Feb 24, 2015 · Penalty $500

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

DatePriceTypeUnits
Dec 18, 2025$26,643,750Other hotels1

Building details

Building type
Hotel (H3)
Year built
2015
Floors
13
Residential units
1
Building area
44,168 ft²
Lot area
5,888 ft²
Zoning
M1-3
Community board
401
Council district
26
Block / lot
475 / 30
Assessed value
$4,838,850
Landmark / historic district
No

Questions about 9-02 38 Avenue

Who owns 9-02 38 Avenue?

The owner of record in NYC Department of City Planning PLUTO data is Reit 38 LLC.

Does 9-02 38 Avenue have violations?

NYC HPD has no housing violations on record for this property.

Is 9-02 38 Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 9-02 38 Avenue built?

City records list 2015 as the year it was built.

How many apartments are in 9-02 38 Avenue?

It has 1 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.