roofy

38-21 9 Street

Queens, NY 11101BBL 4-00475-0026Map

Owner of record: 9th Street Hospitality Propco LLC

38-21 9 Street is a hotel built in 2019 in Queens, 11101. The owner of record is 9th Street Hospitality Propco LLC. HPD has recorded 1 housing violation here, most recently on January 9, 2018.

HPD violations
1
DOB violations
11
ECB violations
33
HPD complaints
57

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Jan 9, 2018

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 1

  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Jan 9, 2018

    Closed — Violation closed

DOB building violations · 11

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 22, 2025

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 2, 2024

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2024

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 5, 2022

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 22, 2021

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 1, 2021

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 23, 2020

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 2, 2020

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Feb 19, 2020

    Dob violation - dismissed
Show 1 more ↓
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 26, 2019

    Dob violation - dismissed

ECB violations · 33

  • Class - 1

    Failure to submit the required parking structure initial observation report for an existing parking structure documenting the conditions of psid#q0004472 by the august 1,2024 deadline.to date,the department has

    Oct 1, 2024 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to maintain building in code compliant manner. at time of inspection on the roof inside gravity tank i observed unapproved pvc liner bag. gravity tank shall comply with nfpa 22, repair and/replace

    Oct 13, 2021

    Resolve
  • Class - 1

    Failure to have site safety manager as required.at time of inspection on active jobsite of 16 story new building observed site safety manager (james farrin ssm #32) was performing duties with expired license (e

    Oct 1, 2021 · Penalty $625

    Resolve
  • Class - 2

    Work does not conform to approved construction documents and/or approved amendments.at time of inspection on active jobsite of 16 story new building observed 20 ft sidewalk shed extention "b" of "c" is not inst

    Oct 1, 2021 · Penalty $620

    Resolve
  • Class - 1

    Failure to provide sws where required:atoi@active jobsite nb16sty 162'h,248units hotel bldg,it was observed failure to provide/maintain sws@exp1 whereas active mechanicalwork was ongoing@roof level&work to be c

    Jun 9, 2021 · Penalty $10,000

    Resolve
  • Class - 2

    Failure to provide/maintain adequate housekeeping per sec requirements:atoi@active jobsite nb16sty hotel bldg,it was observed failure to provide/maintain adequate housekeeping on various fls w/const materials&d

    Jun 9, 2021

    Resolve
  • Class - 2

    Failure to maintain adequate housekeeping at time of inspection i observed construction debris and materials on exposure#1,#3,& #4 at groundlevel & throughout 1st floor.this condition is hazardous blocking pass

    Jan 24, 2021 · Penalty $1,250

    Resolve
  • Class - 1

    Bc 2113.1.6.1 failure to extend chimney at least 3 feet above roof level.at time of inspection observed an active jobsite 16 story nb,where building is at 16 fl(top off)adjacent property chimney not being exten

    Sep 29, 2020

    Resolve
  • Class - 2

    Failure to maintain adequate housekeeping per section requirements.at the of inspection on a active jobsite of a 16 story nb,observed inadequate housekeeping at various locations throughout entire jobsite.this

    Sep 29, 2020

    Resolve
  • Class - 2

    Bc 3303.2.3.1 temporary lights at time of inspection on a active jobsite of a 16 story nb,observed that no lights was connected or plug in on stoneways and in cellar.failure to provide or maintained temporary l

    Sep 29, 2020

    Resolve
Show 23 more ↓
  • Class - 1

    3314.8 failure to provide guardrails system note: @time of my inspection of a 16 sty new building @roof lvl under construction i observed supported pipe scaffold installed outside of the building up to roof lvl

    Jul 1, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    Bc 3314.1 failure to maintain supported pipe scaffold.note: @time of my inspection of a 16 sty new building @roof lvl. under const i observed supported pipe scaffold installed outside of the building & was

    Jul 1, 2020 · Penalty $2,500

    Resolve
  • Class - 2

    Supported scaffold is contrary to approved plan. noted: at time of inspectoin i observed active site for which a ssm is requires w/the supported scaffold installed on exp#1,3&4 contrary to the approved plan.

    May 21, 2020

    Resolve
  • Class - 3

    Failure to provide required worker safety information sign as per rcny1-3301-03(a)noted:workers on site working under application#420656347 majority at workers speaking chinese language without required worker

    Feb 26, 2020

    Resolve
  • Class - 2

    Permit holder/owner/workers employer failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1:observed shi shengyuan at building site for which a const

    Feb 26, 2020 · Penalty $2,500

    Resolve
  • Class - 2

    Permit holder/owner/workers employer failed to ensure each construction or demolition worker successfully completed the required training under bc3321.1:observed shi sheng yuan at building site for which a cons

    Feb 26, 2020 · Penalty $2,500

    Resolve
  • Class - 2

    Work does not conform to approved construction documents and/or approved amendments.at the time of inspection it was observed sidewalk shed installed at exposure 1.it was noted upon review of the plans eq105.00

    Feb 26, 2020

    Resolve
  • Class - 2

    Bc33012-failure to provide overhead protection.at the time of my inspection it was observed active construction site with scaffold at exposure 1 where it was noted that there was no overhead protection between

    Feb 26, 2020

    Resolve
  • Class - 1

    Supported scaffold not to plan note: @time of inspection i observed supported scaffold on site with following objections- truss system in use that does not reflect on plans.rem: comply/amend to plan.

    Nov 29, 2019 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to maintain adequate housekeeping note: @time of inspection i observed that there was a lack of housekeeping throughout site as wellas concrete washouts & dumping of egress concrete on work site.

    Nov 29, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    3305-1 reshores not secure as per code note: @time of inspection i observed reshoring not fastehed or secured as per this code 3305-3.6.1.2 does not comply.rem: secure reshores as per code.

    Nov 29, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Bc3316.1/hoisting equipment.note:at the time of inspection of a 16 story nb in progress at 15 level i observed the hoist for the job site stoped at the 7th floor.this is a unsafe and hazardous condition for 1st

    Oct 24, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Bc3308.6.1.4/supported scaffold alternative.noted;at time of inspection of a purposed 16 story nb in progress at 15th level.i observed therewas form work and stripping work being done i observed from the 10th f

    Oct 24, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Bc 3303.12 hoists. note:at time of my inspection of a 16 story building at 13th fl level under construction i observed elevators and hoist was not working at time of my inspection. as require. site safety manag

    Sep 27, 2019

    Resolve
  • Class - 1

    Bc 3310.8.2.1 failure to notification of condition to the dept. note:at time of my inspection of a 16 story building at 13th fl level under construction i observed that hoist not working broken for 2 days. site

    Sep 27, 2019 · Penalty $625

    Resolve
  • Class - 1

    Bc 3308.6 failure to provide horizontal safety netting system. note:attime of my inspection of a 16 story building at 13th fl level under construction. i observed that no horizontal netting system provided as r

    Sep 27, 2019 · Penalty $2,500

    Resolve
  • Class - 2

    Bc3301.2 failure to safeguard all persons and property affected by construction operations. at time of inspection on an inactive construction site notice power lines running through sidewalk shed w/o protec

    Jul 30, 2019

    Resolve
  • Class - 2

    Bc 3301.7 failure to provide p.e approved complete set structural drawings on job site. as noted: @time of inspection an active const site. observed rebar placement @floor #3 and no complete set of structural

    Jul 24, 2019

    Resolve
  • Class - 2

    Bc3301.7 failure to provide pe approved design drawings for formworksas noted at time of inspeciton 3rd floor work level. failure to provide pe approved design drawings for formwork.rmdy: stop all concrete ope

    Apr 12, 2019

    Resolve
  • Class - 2

    3307.3.2:failure to provide lot line fence.note:at time of inspection i observed section fence missing at exposure 3 and 4,site safety plan shows fence be provided for entire exposure 3 and 4.comply with code.

    Nov 7, 2018

    Resolve
  • Hazardous

    Failure to comply with fire apartment approved gates. noted: multiple dwelling bldg has illegal key lock gate at main entrance of bldg. remedy: provide fire apartment approved key lock gates.

    Oct 31, 2005 · Penalty $180

    Resolve
  • Non-hazardous

    Failure to comply with fire apartment approved gates. noted: multiple dwelling bldg has illegal key lock gate at main entrance of bldg. remedy: provide fire apartment approved key lock gates.

    Oct 31, 2005 · Penalty $250

    Resolve
  • Non-hazardous

    Failure to maintain. noted: bathroom ceiling in danger of collapsing. size of ceiling approx. 4'wx6'long. (at 1st floor rear) remedy:repair defects immediately.

    Sep 14, 2000 · Penalty $2,500

    Resolve

Complaints

  • Unsanitary condition

    Pests

    May 11, 2026 · Apt 1302

    Close
  • Unsanitary condition

    Pests

    Oct 16, 2024 · Apt 1411

    Close
  • Plumbing

    Water supply

    Sep 29, 2016 · Apt 2F

    Close
  • Heat/hot water

    Apartment only

    Jan 5, 2016 · Apt 2F

    Close
  • Heat/hot water

    Entire building

    Oct 4, 2015 · Apt 1R

    Close
  • Plumbing

    Basin/sink

    Jan 28, 2015 · Apt 1ST

    Close
  • General

    Cabinet

    Jan 28, 2015 · Apt 1ST

    Close
  • Unsanitary condition

    Pests

    Jan 28, 2015 · Apt 1ST

    Close
  • Paint/plaster

    Wall

    Jan 28, 2015 · Apt 1ST

    Close
  • Water leak

    Slow leak

    Jan 15, 2015 · Apt B2

    Close
Show 40 more ↓
  • General

    Cabinet

    Jan 15, 2015 · Apt B2

    Close
  • Unsanitary condition

    Pests

    Jan 15, 2015 · Apt B2

    Close
  • Paint/plaster

    Wall

    Jan 15, 2015 · Apt B2

    Close
  • General

    Ventilation system

    Jan 15, 2015 · Apt B2

    Close
  • Flooring/stairs

    Floor

    Jan 15, 2015 · Apt B2

    Close
  • Plumbing

    Basin/sink

    Jan 15, 2015 · Apt B2

    Close
  • Plumbing

    Water supply

    May 21, 2014 · Apt 1R

    Close
  • Plumbing

    Water supply

    May 18, 2014 · Apt 1R

    Close
  • Door/window

    Window frame

    Mar 24, 2014 · Apt 1R

    Close
  • Heat/hot water

    Entire building

    Mar 24, 2014 · Apt 1R

    Close
  • Heating

    Heat related

    Oct 30, 2013 · Apt NA

    Close
  • Heating

    Heat related

    Oct 23, 2013 · Apt NA

    Close
  • Heating

    Heat related

    Oct 23, 2013 · Apt NA

    Close
  • Paint/plaster

    Wall

    Nov 28, 2012 · Apt 2FL

    Close
  • General

    Doors

    Nov 28, 2012 · Apt 2FL

    Close
  • General

    Doors

    Nov 14, 2012 · Apt 2FL

    Close
  • General

    Doors

    Nov 14, 2012 · Apt 2FL

    Close
  • Nonconst

    Vermin

    Nov 14, 2012 · Apt 2FL

    Close
  • Heating

    Heat related

    Feb 2, 2011 · Apt 1F

    Close
  • Heating

    Heat related

    Jan 23, 2011 · Apt 1F

    Close
  • Electric

    Wiring

    Jan 23, 2011 · Apt 1F

    Close
  • Heating

    Heat related

    Jan 21, 2008 · Apt 2FL

    Close
  • Nonconst

    Vermin

    Jun 28, 2007 · Apt 1F

    Close
  • Nonconst

    Vermin

    Jun 28, 2007 · Apt 1F

    Close
  • Appliance

    Refrigerator

    Jun 28, 2007 · Apt 1F

    Close
  • Nonconst

    Vermin

    Feb 4, 2007 · Apt 2F

    Close
  • Nonconst

    Vermin

    Feb 4, 2007 · Apt 2F

    Close
  • Nonconst

    Vermin

    Feb 4, 2007 · Apt 2F

    Close
  • Nonconst

    Vermin

    Feb 4, 2007 · Apt 2F

    Close
  • Heating

    Heat related

    Dec 8, 2006 · Apt 2R

    Close
  • Nonconst

    Vermin

    Dec 5, 2006 · Apt 2R

    Close
  • Heating

    Heat related

    Dec 5, 2006 · Apt 2R

    Close
  • Nonconst

    Vermin

    Dec 3, 2006 · Apt 2R

    Close
  • Heating

    Heat related

    Dec 3, 2006 · Apt 2R

    Close
  • Electric

    Bell-buzzer/intercom

    Dec 2, 2005 · Apt 1F

    Close
  • General

    Doors

    Dec 2, 2005 · Apt 1F

    Close
  • General

    Windows

    Dec 2, 2005 · Apt 1F

    Close
  • Paint/plaster

    Ceiling

    Dec 2, 2005 · Apt 1F

    Close
  • Heating

    Heat related

    Nov 28, 2005 · Apt 1F

    Close
  • Plumbing

    Water-leaks

    Nov 28, 2005 · Apt 1F

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Hotel (H3)
Year built
2019
Floors
16
Residential units
—
Building area
87,763 ft²
Lot area
9,983 ft²
Zoning
M1-3
Community board
401
Council district
26
Block / lot
475 / 26
Assessed value
$9,638,100
Landmark / historic district
No

HPD registration #434410, last renewed Jul 22, 2025.

Questions about 38-21 9 Street

Who owns 38-21 9 Street?

The owner of record in NYC Department of City Planning PLUTO data is 9th Street Hospitality Propco LLC.

Does 38-21 9 Street have violations?

Yes. NYC HPD has recorded 1 housing violations at this property.

Is 38-21 9 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 38-21 9 Street built?

City records list 2019 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.