roofy

41-34 27th Street

Queens, NY 11101BBL 4-00415-0004Map

Owner of record: Queens Plaza North New York, LLC

41-34 27th Street is an elevator apartment building built in 2023 in Queens, 11101. It has 417 residential units across 27 floors. The owner of record is Queens Plaza North New York, LLC. HPD has recorded 1 housing violation here, most recently on May 11, 2026.

HPD violations
1
DOB violations
47
ECB violations
19
HPD complaints
4

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation May 11, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 1

  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    May 11, 2026

    Closed — Violation dismissed

DOB building violations · 47

  • Construction other optional

    Dob summons issued for structure rendered non compliant due to motor vehicle impacting sidewalk shed damaging several upright post and 2 bays of cross bracing of shed.

    Oct 4, 2024

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2024

    Dob violation - dismissed
  • Construction other optional

    Fail2perform standrd curing specmn:obsrvd 1/23/24@fenagh llc inspctn, temps of final curing tanks were 51-53degrees f,well outside limit of 73.5 +- 3.5f&temp recordrs disconctd from tanks&dry to touch. remedy: comply w codes&req astm stndrds.eor revw non-conformnce,submt s/s w alternate test results by 5/31/24

    Mar 8, 2024

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 9, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 9, 2019

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2015 inspection/test

    Dec 1, 2016

    Dob violation - dismissed
  • Residential elevator periodic inspection/test elevatorrequired

    Failure to perform category 5 inspection

    Jun 1, 2016

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2014 inspection/test

    Jun 10, 2015

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2013 inspection/test

    Oct 31, 2014

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2012 inspection/test

    Mar 31, 2014

    Dob violation - dismissed
Show 37 more ↓
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 24, 2014

    Dob violation - resolved
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Jun 3, 2013

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 4, 2013

    Dob violation - resolved
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2011 inspection/test

    Oct 1, 2012

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 26, 2012

    Dob violation - resolved
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 3, 2012

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2010 inspection report

    Dec 13, 2011

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2010 inspection/test

    Dec 13, 2011

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 25, 2011

    Dob violation - resolved
  • Elevator annual inspection / test elevatorrequired

    Vcat1-elevator annual inspection / test elevatorrequired

    Oct 8, 2010

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 29, 2007

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 19, 2007

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 4, 2006

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 6, 2006

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 6, 2006

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 31, 2005

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 31, 2005

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 10, 2005

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 13, 2004

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 13, 2004

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 13, 2003

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 19, 2003

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 19, 2003

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 26, 2002

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 7, 2000

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 10, 1997

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Apr 17, 1995

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 7, 1994

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    May 31, 1994

    Dob violation - dismissed
  • Construction other optional

    C-construction other optional

    Dec 9, 1993

    Vp*-violation unserved ecb- dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jun 28, 1993

    Dob violation - dismissed

ECB violations · 19

  • Class - 2

    At time of my inspection of a 27 story nb/active jobsite, i observed inadequate fire extinguishers (missing safety pins, old/damage, missing inspection tags and all missing monthly inspection) comply with code

    May 14, 2024

    Resolve
  • Class - 2

    At time of my inspection on a active jobsite of a 27 story nb,observed that housekeeping throughout the site were inadequate,mix material and debris creating a trip and fall hazard for workers and personal on s

    May 14, 2024

    Resolve
  • Class - 1

    At time of inspection on a active job site of a 27 story nb,observed workers working without hard hats.this create a hazardous condition for workers to get injured from falling objectscomply with code

    May 14, 2024 · Penalty $5,000

    Resolve
  • Class - 2

    Observed 2 outrigger temp. platforms in courtyard area at 7th & 8th floors,upon reviewing the approved documents for the platforms it showed 4 floors below to be equipped with re-shores, upon walking site, unab

    Jan 22, 2024 · Penalty $1,250

    Resolve
  • Class - 1

    At the time of my inspection of a 24 story building at superstructure phase approximately 6000 cubic yard of concrete,concrete operation in progress. upon request for concrete safety manager, # 2177 was provide

    Sep 6, 2023 · Penalty $625

    Resolve
  • Class - 1

    Responding to an incident where a gas line was hit, inspection reveal that there were no verification before operation as mark only indicate general location and there were no additional safety measures provide

    Aug 17, 2023

    Resolve
  • Class - 1

    The lack of proper ingress/egress for the workers to access the opposite side of a control access zone at the 2nd story level when necessary, caused a worker to step down off a scaffold and facade wall, about 3

    Aug 13, 2022

    Resolve
  • Class - 1

    A worker was injured while stepping down from a supported scaffold, and facade wall on to the 2nd story floor, when he stepped onto a brick that caused him to slip and fall hurting his ankle. the inadequate hou

    Aug 13, 2022 · Penalty $2,500

    Resolve
  • Class - 2

    I observed active demo site with 6 workers on the roof level. upon request for demo plans, they show window openings boarded with plywood. half of all window openings not boarded with any plywood. also inadequa

    Jul 6, 2022

    Resolve
  • Class - 1

    Tr1 for structural stability(1704.20.1) i observed active demo site with 6 workers present. upon request to view the tr1 for structural stability, none were provided or found on department records. also no deta

    Jul 6, 2022 · Penalty $625

    Resolve
Show 9 more ↓
  • Class - 1

    Failure to comply with violation number, 39002140y. issued on 04-15-2019 no-compliance recorded., comply with commissioner's order

    Aug 13, 2019

    Resolve
  • Class - 1

    Failure to comply with violation number, 39002139r. issued on 04-15-2019 no-compliance recorded., comply with commissioner's order

    Aug 13, 2019 · Penalty $6,250

    Resolve
  • Class - 1

    Work without a permit i observed on first second floor sprinkler system was removed , obtain permit

    Apr 15, 2019

    Resolve
  • Class - 1

    Failure to maintain building in code-complaint manner: lack of a system of automatic sprinklers where required per bc903.2;27-954 i observed no sprinkler system on first floor and on second floor no sprinkler s

    Apr 15, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to maintain bldg wall(s) or appurtenances. noted: at parapet level above "chase bank" entrance, a section of lintel has fallen to the ground (approx 6"x8"long). brick work appears to pulling away &

    Jun 23, 2011 · Penalty $1,000

    Resolve
  • Class - 3

    Work does not conform to approved construction documents or amendmentsbased on extent of work progress significant change 1st flr band plan indicates 2 exit or 2 door contrary to approved plan. remedy: conform

    Jul 25, 2008 · Penalty $500

    Resolve
  • Non-hazardous

    84l10/86bb5/84u15/.84l-car communication not working.84u-no company sticker main line.

    Jun 20, 2007 · Penalty $2,500

    Resolve
  • Non-hazardous

    16 49, (1)water column drain reduced (2)submit proof of registration of this boiler fulton nb 67540 year 1993

    May 25, 2001

    Resolve
  • Non-hazardous

    Altered building occupied without a valid certificate of occupancy alt 400350142 co# q00350142 expired on 1-20-94. remedy: obtain a valid c of o

    Mar 18, 1994

    Resolve

Complaints

  • Door/window

    Window frame

    Dec 6, 2025 · Apt 802

    Close
  • Heat/hot water

    Apartment only

    Dec 6, 2025 · Apt 802

    Close
  • Heat/hot water

    Entire building

    Nov 28, 2024 · Apt BLDG

    Close
  • Heating

    Heat related

    Dec 4, 2007 · Apt 1

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D7)
Year built
2023
Floors
27
Residential units
417
Building area
370,361 ft²
Lot area
30,540 ft²
Zoning
M1-5/R9
Community board
401
Council district
26
Block / lot
415 / 4
Assessed value
$31,325,400
Landmark / historic district
No

HPD registration #434538, last renewed Jun 18, 2026.

Questions about 41-34 27th Street

Who owns 41-34 27th Street?

The owner of record in NYC Department of City Planning PLUTO data is Queens Plaza North New York, LLC.

Does 41-34 27th Street have violations?

Yes. NYC HPD has recorded 1 housing violations at this property.

Is 41-34 27th Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 41-34 27th Street built?

City records list 2023 as the year it was built.

How many apartments are in 41-34 27th Street?

It has 417 residential units and 418 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.