roofy

2920 Brighton 4 Street

Brooklyn, NY 11235BBL 3-08663-0260Map

Owner of record: Ssjl 2920 Brighton 4th LLC

2920 Brighton 4 Street is an elevator apartment building built in 2019 in Brooklyn, 11235. It has 13 residential units across 4 floors. The owner of record is Ssjl 2920 Brighton 4th LLC. HPD has recorded 5 housing violations here, most recently on May 8, 2026. City tax records listed 12 rent-stabilized apartments here in 2024.

HPD violations
5
DOB violations
8
ECB violations
31
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation May 8, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
12
About 92% of the building's 13 apartments

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 5

  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    May 8, 2026

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Jun 16, 2025

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 17, 2024

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Mar 31, 2023

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Mar 10, 2022

    Closed — Violation dismissed

DOB building violations · 8

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 16, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 16, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 2, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 2, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 4, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 26, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Apr 3, 2019

    Dob violation - dismissed
  • Construction other optional

    C-construction other optional

    Jan 2, 2019

    Vpw*-violation unserved ecb-work without permit-dismissed

ECB violations · 31

  • Class - 1

    Bc 3303.7.2 fire extinguisher noted: @time of inspection of an active jobsite. observed on multiple floor stair no fire extinguisher in place in case @a fire.rem: comply with nyc fire code.

    May 15, 2020 · Penalty $2,500

    Resolve
  • Class - 2

    Construction super failed to perform duties per code. noted: @time of inspection of an active jobsite. upon request to see the const super logs it was provided and upon reviewing the logs observed the cs

    May 15, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to maintain adequate housekeeping per section requirements.noted: @time of inspection of & active jobsite. observed @exp#3 rear yard inadequate housekeeping pile up more than 5 ft in height which make

    May 15, 2020 · Penalty $625

    Resolve
  • Class - 1

    Competent person. at the time of inspection at a 4 sty nb,i observed on a active jobsite no superintendent or no competent person present between the hours of 1pm - 3pm upon review of daily log books no signatu

    Apr 16, 2020 · Penalty $5,000

    Resolve
  • Class - 1

    Inadequate log book. at the time of inspection at a 4 sty nb,i observed upon reviewing superintendent log book last signed & dated entry was3-23-20 while job site not completed & workers working on interior con

    Apr 16, 2020 · Penalty $5,000

    Resolve
  • Class - 2

    Failure to maintain adequate housekeeping per section requirements. atthe time of inspection at a 4 sty nb,i observed in the rear yard exp#3 heavy piles of dfebris,garbage & material scaddered all over the rear

    Apr 16, 2020 · Penalty $1,250

    Resolve
  • Class - 1

    Bc3301.2=safety measures uncapped rebars.at the tim eof inspection on actiev construction site 4 story new building i observed rebars at ground floors sticling out of concrtee vetrically missing and improperly

    Feb 11, 2020

    Resolve
  • Class - 1

    Bc3301.2=failure to instistute and maintain safety equipment adequate means of egress.at the time of inspection fo 4 story new building work in progress i observed 2 means of egress stairs from 1st to 2nd floor

    Feb 11, 2020 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to maintain adeqaute housekeeping per section requirments at the time of inspection at active construction site i observed inadequate house keeping consisting of larg eamounts of debris at ground floor

    Feb 11, 2020 · Penalty $625

    Resolve
  • Class - 1

    Unlawful acts failure to comply with commissiners order at time of inspection i found a actiev jobsiet sewer crew and one single laborer present on siet (4 total ) no persosn identified as a competent person o

    Jan 15, 2020 · Penalty $2,500

    Resolve
Show 21 more ↓
  • Class - 1

    Failure to designate a construction superintendent present at site as required.at time of my inspection of active jobsite.i found no person when indentified as competent person,the side superintendent affiliate

    Jan 15, 2020

    Resolve
  • Class - 2

    Bc33012-failure to institute safety measures and standards.at time of my inspection i observed laborer working exterior exp#1 roof level,at this area i observed supported scaffolds without screw jacks baseplate

    Jan 15, 2020 · Penalty $625

    Resolve
  • Class - 1

    Bc 3303.2.1 existing services-not maintained/protected. noted:at the time of my inspection sidewalk shed installed at exp#1 in front of 2920brighton 4 st where it was observed existing electrical wires at exp 1

    Dec 11, 2019 · Penalty $1,250

    Resolve
  • Class - 2

    Bc 3303.4.1 sidewalk not maintained,consisting of large cracks,holes and voids uneven due to construction activities creating a trip hazard for pedestrians. noted:at the time of my inspection it was observed si

    Dec 11, 2019

    Resolve
  • Class - 2

    Temporary construction equipment on site-expired permit. noted: at thetime of my inspection it was observed that fence application for temporary construction fence has expired on 11/27/19. remedy: renew permit

    Dec 11, 2019 · Penalty $625

    Resolve
  • Class - 2

    Bc 3307.6.4.8 defective sidewalk shed lighting. noted:at the time of my inspection it was observed that the underside of sws erected at exp#1 and exposure#2 was not lighted-the lights were not turned on to prov

    Dec 11, 2019

    Resolve
  • Class - 1

    Bc3301.6/design drawing;observed mateial pulley resting on cross bracing of scaffold and guardrails @ exp#1 with material attached to it.no one on site able to provide design drawings for configuration material

    Nov 27, 2019

    Resolve
  • Class - 1

    Bc3314.5/scaffold construction exterior work still needing to be complete observed netting no secured decks not fully planked planks not tied down material left on scaffold above pathways of site personal mater

    Nov 27, 2019

    Resolve
  • Class - 2

    Failure to safeguard ohp @ expo 1 above egress pathway is planks resting on tiebacks for scaffold.no drawings provided to verity setup is anadequate means of protection or support.multiple areas of rebar uncapp

    Nov 27, 2019

    Resolve
  • Class - 2

    Competent person.at time of inspection requested to see the compentent person or superintendent 2 workers were unable to identify the comp person for me.conducted an inspection on all 4 floors and roof.attempte

    Nov 27, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Work w/o a permit. upon reinspection of a 4 sty nb i observed on 3rd fl,niddle beams extending out of exp#4 w/a supported scaffold built on top of it had no design drawings nor permit. remedy: provide niddle

    Sep 11, 2019 · Penalty $625

    Resolve
  • Class - 2

    Work w/o a permit. at time of inspection of an active site currently at bulkhead level observed supported scaffold installed aprpx 55'in height on all exposures (1,2,3,4) after reviewing department records

    Jul 8, 2019 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to maintain safety measures (guardrails). at time of inspection of an active site observed an approximate 8' wide x 6' openings in concrete slab floor on 2,3,4 level. there were no guardrails in place a

    Jul 8, 2019

    Resolve
  • Class - 1

    Bc3301.2. inadequate overhead protection- expo#4. at time of inspection of a 4-story new building observed inadequate overhead protection for adjacent property exposure #4. observed 2x4s with loose debris netti

    Jun 10, 2019 · Penalty $2,500

    Resolve
  • Class - 2

    Pedestrian protection does not meet code specifications at time of inspection of a 4-story new building observed the following violating conditions that put pedestrians in danger, missing protective caps on sid

    Jun 10, 2019 · Penalty $2,400

    Resolve
  • Class - 2

    28-110.1;plans inadequate site safety plans.at time of inspectiuon at an active 4 stroy new building construction site i observed teh site safety plan was missing overhead protetcion for adjacent at exposure #4

    May 29, 2019 · Penalty $625

    Resolve
  • Class - 1

    No site-specific formwork design drawings-overhead protection.@time ofinspection @an active 4 sty new building construction site, i observeda make shift overhead protection made of pieces of "2*4" and netting

    May 29, 2019

    Resolve
  • Class - 1

    Failure to safeguard all persons & property after ted by const operation-inadequate guardrail system.@time of inspection @an active 4 sty new building const site, i observed zero cable system on the second,

    May 29, 2019 · Penalty $10,000

    Resolve
  • Class - 1

    Failure to maintain/display on site documents required by chapter 33-inadequate inspection logs.@time of inspection @an active 4sty new building const site, i observed concrete safety straps on the 2nd, 3rd and

    May 29, 2019 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to provide sidewalk shed as required. at time of inspection ofan active jobite currently at 2nd sty level observed concrete form & rebar work being done @ exp#1 above fence line approx 22 feet off exist

    Apr 2, 2019 · Penalty $10,000

    Resolve
  • Class - 1

    Demolition work w/o a required demolition permit. noted:upon review ofdept records(dob bis) observed 2 building on lot main house and car garage. however observed main house has demo permit and car garage did n

    Jan 2, 2019 · Penalty $5,000

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D6)
Year built
2019
Floors
4
Residential units
13
Building area
11,677 ft²
Lot area
4,240 ft²
Zoning
R6
Community board
313
Council district
48
Block / lot
8663 / 260
Assessed value
$896,850
Landmark / historic district
No

HPD registration #389623, last renewed Jul 22, 2025.

Questions about 2920 Brighton 4 Street

Who owns 2920 Brighton 4 Street?

The owner of record in NYC Department of City Planning PLUTO data is Ssjl 2920 Brighton 4th LLC.

Does 2920 Brighton 4 Street have violations?

Yes. NYC HPD has recorded 5 housing violations at this property.

Is 2920 Brighton 4 Street rent stabilized?

NYC Department of Finance tax bills listed 12 rent-stabilized units here in 2024 (about 92% of its 13 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 2920 Brighton 4 Street built?

City records list 2019 as the year it was built.

How many apartments are in 2920 Brighton 4 Street?

It has 13 residential units and 14 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.