1044 East New York Avenue is an elevator apartment building built in 2007 in Brooklyn, 11212. It has 68 residential units across 7 floors. The owner of record is E.n.y. Plaza LLC. HPD has recorded 130 housing violations here, most recently on April 12, 2026. City tax records listed 68 rent-stabilized apartments here in 2024.

HPD violations
130
DOB violations
24
ECB violations
57
HPD complaints
37

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Apr 12, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
68
About 100% of the building's 68 apartments

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 130

  • C

    M/d law abate the nuisance consisting of scalding hot water above 130 degrees in the entire apartment located at apt 7e, 1st apartment from south at west

    Apr 12, 2026 · Apt 7E

    Closed — Violation dismissed
  • C

    Provide hot water at all hot water fixtures in the entire apartment located at apt 5j, 5th story, 4th apartment from west at north

    Jun 8, 2025 · Apt 5J

    Closed — Violation closed
  • C

    Install the missing or repair/replace the defective window guard(s) in accordance with the specifications of the new york city health code section 24 rcny chapter 12. wg to install = 0, wg to replace = 0, wg to repair = 4 in the entire apartment located at apt 5j, 5th story, 4th apartment from west at north

    Jun 8, 2025 · Apt 5J

    Closed — Violation closed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 17, 2024

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 20, 2023

    Closed — Violation dismissed
  • C

    Replace the broken or defective [corroded] natural gas supply pipes and meters at east wall in meter room at cellar

    Nov 2, 2023

    Closed — Violation closed
  • C

    M/d law abate the nuisance consisting of hot water exceeds the maximum of 130 degrees found water to be 134 in the entire apartment located at apt 6g, 6th story

    Apr 19, 2023 · Apt 6G

    Closed — Violation closed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Mar 31, 2023

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 7, 2022

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Mar 9, 2022

    Closed — Violation dismissed
Show 40 more ↓
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 19, 2021

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 4, 2019

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 26, 2018

    Closed — Violation dismissed
  • C

    Provide adequate supply of hot water for the fixtures .. in the entire apartment located at apt 2h, 2nd story, 2nd apartment from west at north

    Aug 20, 2017 · Apt 2H

    Closed — Violation closed
  • B

    Trace and repair the source and abate the nuisance consisting of mold ... approx., 12 square feet on the ceiling in the bathroom located at apt 5i, 5th story, 4th apartment from west at north

    Jul 25, 2016 · Apt 5I

    Closed — Violation closed
  • C

    Provide ready access to buildings heating system locked door to central heating and ventilation unit at the closet at east in the foyer located at apt 5i, 5th story

    Jul 25, 2016 · Apt 5I

    Closed — Violation closed
  • C

    Provide hot water at all hot water fixtures in the entire apartment located at apt 5i, 5th story, 4th apartment from west at north

    Jul 25, 2016 · Apt 5I

    Closed — Violation closed
  • C

    Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling in the bathroom located at apt 5i, 5th story, 4th apartment from west at north

    Jul 25, 2016 · Apt 5I

    Closed — Violation closed
  • C

    Properly repair the source and abate the evidence of a water leak at the ceiling in the bathroom located at apt 5i, 5th story, 4th apartment from west at north

    Jul 25, 2016 · Apt 5I

    Closed — Violation closed
  • C

    Properly repair the broken or defective air intake vent pipe to the water heater in the applience closet located at apt 4b, 4th story, 2nd apartment from east at south

    Jun 9, 2016 · Apt 4B

    Closed — Violation closed
  • C

    Provide hot water at all hot water fixtures in the entire apartment located at apt 4b, 4th story, 2nd apartment from east at south

    Jun 9, 2016 · Apt 4B

    Closed — Violation closed
  • C

    Provide ready access to buildings heating system .... at cellar

    Jun 7, 2016

    Closed — Violation closed
  • C

    Provide hot water at all hot water fixtures in the entire apartment located at apt 2i, 2nd story, 2nd apartment from north at east

    Jun 7, 2016 · Apt 2I

    Closed — Violation closed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color ceiling at south bathroom located at apt 5i, 5th story, 4th apartment from north at east

    Apr 29, 2016 · Apt 5I

    Closed — Violation closed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color ceiling at north bathroom located at apt 5i, 5th story, 4th apartment from north at east

    Apr 29, 2016 · Apt 5I

    Closed — Violation closed
  • B

    Properly repair the source and abate the evidence of a water leak damp ceiling at north located at apt 5i, 5th story, 4th apartment from north at east

    Apr 29, 2016 · Apt 5I

    Closed — Violation closed
  • C

    Properly repair with similar material the broken or defective wood floor (approx 15 sq ft, collapsed upwards) in the 2nd room from east located at apt 6g, 6th story, 1st apartment from west at north

    Mar 31, 2016 · Apt 6G

    Closed — Violation closed
  • B

    Repair the leaky and/or defective faucets at bathtub in the 2nd bathroom from east located at apt 6g, 6th story, 1st apartment from west at north

    Mar 31, 2016 · Apt 6G

    Closed — Violation closed
  • B

    Repair the leaky and/or defective faucets at bathtub in the 1st bathroom from east located at apt 6g, 6th story, 1st apartment from west at north

    Mar 31, 2016 · Apt 6G

    Closed — Violation closed
  • C

    Remove all obstructions from water closet at watercloset in the bathroom located at apt 2g, 2nd story, 4th apartment from west at north

    Feb 3, 2016 · Apt 2G

    Closed — Violation dismissed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the foyer located at apt 7f, 7th story, 1st apartment from west at north

    Feb 3, 2016 · Apt 7F

    Closed — Violation closed
  • B

    Properly repair with similar material the broken or defective wood floor in the kitchen located at apt 1b, 1st story, 2nd apartment from east at south

    Feb 3, 2016 · Apt 1B

    Closed — Violation closed
  • B

    Replace or repair the self-closing the doors that is missing or defective .. in the entrance located at apt 1b, 1st story, 2nd apartment from east at south

    Feb 3, 2016 · Apt 1B

    Closed — Violation closed
  • B

    Replace or repair the self-closing the doors that is missing or defective .. in the entrance located at apt 1i, 1st story, 3rd apartment from west at north

    Feb 3, 2016 · Apt 1I

    Closed — Violation closed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the kitchen located at apt 1i, 1st story, 3rd apartment from west at north

    Feb 3, 2016 · Apt 1I

    Closed — Violation closed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the bathroom located at apt 1i, 1st story, 4th apartment from west at north

    Feb 3, 2016 · Apt 1I

    Closed — Violation closed
  • B

    Remove all obstructions and repair all defects in at bathtub in the bathroom located at apt 2j, 2nd story, 2nd apartment from west at north

    Feb 3, 2016 · Apt 2J

    Closed — Violation closed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the kitchen located at apt 1f, 1st story, 3rd apartment from south at west

    Feb 3, 2016 · Apt 1F

    Closed — Violation closed
  • B

    Remove all obstructions and repair all defects in wasteline at washbasin in the bathroom located at apt 2g, 2nd story, 4th apartment from west at north

    Feb 3, 2016 · Apt 2G

    Closed — Violation closed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the kitchen located at apt 3f, 3rd story, 3rd apartment from south at west

    Feb 3, 2016 · Apt 3F

    Closed — Violation closed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the 1st room from north located at apt 3e, 3rd story, 2nd apartment from south at west

    Feb 3, 2016 · Apt 3E

    Closed — Violation closed
  • B

    Replace with new the missing door in the bathroom located at apt 4j, 4th story, 4th apartment from west at north

    Feb 3, 2016 · Apt 4J

    Closed — Violation closed
  • B

    Replace with new the missing door in the 1st room from north located at apt 4e, 4th story, 1st apartment from south at west

    Feb 3, 2016 · Apt 4E

    Closed — Violation closed
  • B

    Replace with new the missing door in the bathroom located at apt 5h, 5th story, 2nd apartment from west at north

    Feb 3, 2016 · Apt 5H

    Closed — Violation closed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the bathroom located at apt 5h, 5th story, 2nd apartment from west at north

    Feb 3, 2016 · Apt 5H

    Closed — Violation closed
  • B

    Repair the leaky and/or defective faucets at washbasin in the bathroom located at apt 5i, 5th story, 3rd apartment from west at north

    Feb 3, 2016 · Apt 5I

    Closed — Violation closed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the bathroom located at apt 5i, 5th story, 3rd apartment from west at north

    Feb 3, 2016 · Apt 5I

    Closed — Violation closed
  • B

    Properly secure the loose sink in the kitchen located at apt 5j, 5th story, 4th apartment from west at north

    Feb 3, 2016 · Apt 5J

    Closed — Violation closed
  • B

    Properly repair with similar material the broken or defective fire retarding ceiling at public hall, 7th story, section at east

    Feb 3, 2016

    Closed — Violation closed
  • B

    Abate the nuisance consisting of roaches in the entire apartment located at apt 6i, 6th story, 3rd apartment from west at north

    Feb 3, 2016 · Apt 6I

    Closed — Violation closed

DOB building violations · 24

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 10, 2024

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 4, 2023

    Dob violation - dismissed
  • No report and / or late filing (facade) facade required

    Failed to file fisp cycle 9b technical report by 2/21/2023

    Feb 22, 2023

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 22, 2019

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Feb 16, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 28, 2018

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 27, 2018

    Dob violation - resolved
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    May 16, 2018

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 18, 2017

    Dob violation - resolved
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 18, 2017

    Dob violation - dismissed
Show 14 more ↓
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 2, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    May 3, 2017

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2017

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 28, 2016

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 28, 2016

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 8, 2016

    Dob violation - resolved
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst

    Nov 14, 2016

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 28, 2016

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 12, 2014

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 12, 2013

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 21, 2012

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 14, 2011

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 2, 2010

    Dob violation - resolved
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Feb 27, 2009

    Dob violation - dismissed

ECB violations · 57

  • Class - 2

    Observed pvc exhaust piping used on hot water heaters and heating units in utility rooms from the basement through the 7th floor; on the 7th floor the hot water heater is improperly installed on wood and a spri

    Dec 24, 2025 · Penalty $6,250

    Active
  • Class - 2

    Observed in the basement gas lines in the fire pump room. bathrooms in basement lack trap wrap insulation; and exterior fresh air plate covers in the street are missing, which is contrary to code sections pc 70

    Dec 24, 2025 · Penalty $6,250

    Active
  • Class - 1

    Class 1 cease use items: door zone restrictor mulfunctioning. controller fuse bypassed compromising overcurrent protection. these are the safety features what ensure passenger safety. remedy: to restore service

    Dec 24, 2025 · Penalty $3,125

    Resolve
  • Class - 1

    Failure to maintain building in code compliant manner. a cease use order is in effect for the following item: 1) brake monitor switch inoperative, repair and contact the dob elevator division at elevatorir@buil

    Apr 1, 2025 · Penalty $3,125

    Resolve
  • Class - 2

    Exit door not self-closing. observed non self closing doors at basement level. in the gas meter and electrical room. potential fire hazards., repair/replace door

    Mar 24, 2025

    Resolve
  • Class - 2

    I observed in basement gas meter room corroded gas piping due to water leak from outside through ceiling which is prohibited and not code compliant as per 403.9.1, repair and/or replace

    Nov 2, 2023 · Penalty $655

    Resolve
  • Class - 1

    Observed in the basement/gas meter room damaged gas meter also gas piping severely rusted and corroded. as per fgc 102.3 102.3 maintenance. installations, both existing and new, and parts thereof shall be maint

    Nov 1, 2023 · Penalty $1,280

    Resolve
  • Class - 2

    I observed on all floors, the room containing the heat and hot water system with no remote shutdown as required for fuel burning equipment as per mc 1006.8.1; mc 1006.8.1, comply with code; provide remote shutd

    Nov 1, 2023 · Penalty $1,280

    Resolve
  • Class - 2

    I observed along the corridors on all floors and in the basement areas the convenience outlets not of the tamper resistant type nor made tamper-proof as required for receptacles in common areas accessible to ch

    Nov 1, 2023

    Resolve
  • Class - 1

    Class 1 item: zone restrictor malfunctioning, repair. class 2 item: pit light inoperative, repair.

    Apr 28, 2023 · Penalty $1,250

    Resolve
Show 40 more ↓
  • Class - 1

    Failure to take & provide safety measures such as sidewalk shed,fence,netting etc to secure public safety for documented unsafe facade filing tr6-914685-9b dated 2/7/23.note:at time of inspection no safety meas

    Mar 7, 2023 · Penalty $10,000

    Resolve
  • Class - 2

    Failure to maintain bldg in codecompliant manner.i observed in mechanicalrm on 2fl for apts2f&2g active water leak in ceiling.repair &or replace

    Mar 7, 2022

    Resolve
  • Class - 1

    Cease use item: repair safety edge ( reopening device ) not working.

    Aug 18, 2021 · Penalty $1,250

    Resolve
  • Class - 2

    Replace worn gibs where needed. missing lobby braille tags. misaligned cab mirror. self resetting escape hatch swithces prohibited. operator cover missing. top landing is an illegal vestibule; must conform to 2

    Apr 14, 2021 · Penalty $310

    Resolve
  • Class - 2

    Failure to comply with the commissioners'order contained in summons/violation #35347250n issued on 8/21/18 and to file a cert.of correction pursuant to 28-201.1 and 1rcny 102-01.rem:comply with commissioner's o

    May 29, 2019 · Penalty $1,250

    Resolve
  • Class - 2

    Electrical work w/o a permit.observed in cellar,gas meter/water-sprinkler room,the disconnection 94c,removal of bx/armored cable and the installation of emt conduits.please note emt conduit not properly support

    May 29, 2019

    Resolve
  • Class - 2

    Ec 342.30 failure to support imc raceway(intermediate conduit)observedunder the steel dunage support for the a.c systems,inic raceway,junct ion boxes,9nc flexible liquid tite metallic conduit laying on the roof

    May 29, 2019 · Penalty $400

    Resolve
  • Class - 2

    Failure to comply with the commissioners'order contained in summons/violation #35347251p issued on 8/21/18 and to file a cert.of correction pursuant to 28-201.1 and 1rcny 102-01.rem:comply with commissioner's o

    May 29, 2019 · Penalty $1,250

    Resolve
  • Class - 2

    Failure to comply with the commissioners'order contained in summons/violation #35347252r issued on 8/21/18 and to file a cert.of correction pursuant to 28-201.1 and 1rcny 102-01.rem:comply with commissione's or

    May 29, 2019 · Penalty $625

    Resolve
  • Class - 2

    Failure to comply with the commissioners' order contained in summons/violation #35347253z issued on 8/21/18 and to file a cert.of correctionpursuant to 28-201.1 and 1rcny 102-01.rem:comply with commissioner's o

    May 29, 2019 · Penalty $625

    Resolve
  • Class - 2

    Failure to comply with the commissioners'order contained in summons/violation #35347254k issued on 8/21/18 and to file a cert.of correction pursuant to 28-201.1 and 1rcny 102-01.rem:comply with commissioner's o

    May 29, 2019 · Penalty $625

    Resolve
  • Class - 2

    Mc 1006.8.7 failure to provide control(shut down)observed on all fls,the mechanical boiler rooms with no remote boiler shut-off switch.rem:comply with code/provide remote shut down.

    May 29, 2019

    Resolve
  • Class - 1

    Failure to instaill ground electrode conductor in accordance with section. observed installation of the ground electrode conductor on main with a double narrel luf, this makes the ground electrode conductor non

    May 29, 2019 · Penalty $12,000

    Resolve
  • Class - 2

    59bb7,67x10,99m7,80m7. 59bb7-brake maintenance tag expried on 11/13/167x10-in car phone not working; 99m7-cat one tag missing; 80,7-unable to check counterweight run by car station call locked out and keys mis

    Mar 4, 2019 · Penalty $312

    Resolve
  • Class - 1

    Failure to comply with the commissioners order contained in summons#35359140k and 35347254k issued on 10/30/18 and to file a certificate of correction pursuant to 28-201.1,28-204.4 and 1rcny 102-01.summons 3535

    Dec 14, 2018 · Penalty $1,250

    Resolve
  • Class - 1

    Unlawful act.failure to comply with an order of the commissoners.records indicate no application filed to correct,certify & remove violationcontained in summons #35347254k.rem:comply with commissoner order.

    Oct 30, 2018 · Penalty $1,250

    Resolve
  • Class - 2

    B230 28-302.4:failure to submit a required cycle 8b report of criticalexamination documenting condition of exterior wall and appurtences required by 28-302.4 for control#814685.rem:submit required tech report

    Oct 15, 2018 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner. observed on 8-21-18at above address no splinkler lead in basement corridor. remedy: repair & or replace.

    Aug 21, 2018 · Penalty $1,562

    Resolve
  • Class - 2

    Electrical work w/o a permit. observed the basement mechanical rooms installation of a mini sp;it a.c. system. previous app#b291291 does not cover this installation. remedy: comply w/code/obtain permit.

    Aug 21, 2018 · Penalty $800

    Resolve
  • Class - 2

    Failure to secure/support raceways/cable assemblies/boxes/cabinets/fittings/ observed in basement gas meter room.mc cables resting a top gas service pipes. remedy: comply w/code.

    Aug 21, 2018 · Penalty $625

    Resolve
  • Class - 1

    Failure to install grounding electrode conductor in accordance with section.observed installation of ground conductor on water main with a double barrell lug,this makes the ground conductor electrode non contin

    Aug 21, 2018 · Penalty $600

    Resolve
  • Class - 2

    Sec. 1006.8.1 failure to provide remote control(shut down)observed on all floors the mechanical boiler rooms w/no remote boiler shut off switch. remedy: comply w/code-supply remote shut off.

    Aug 21, 2018 · Penalty $800

    Resolve
  • Class - 2

    Sec. 342.30 failure to support imc raceway(intermediate conduit)observed under the steel dunage support,for the a.c. systems. imc conduit & junction boxes & (seal tite) flexible liquid tite metallic conduit,lay

    Aug 21, 2018 · Penalty $800

    Resolve
  • Class - 1

    Failure to maintain bldg in code-compliant manner. lack of a system ofautomatic sprinklers where required per bc 903.2; 27-954. observed in basement partial areas not having any fire sprinkler heads installed

    Feb 13, 2018 · Penalty $1,000

    Resolve
  • Class - 2

    Exit door not self closing. noted: observed at roof, roof exit does not self close, door remains in the open position due to missing door closing hardware at stair "a" bulkhead. rem: repair and/or replace.

    Feb 13, 2018 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to maintain building wall(s) or appurtenances. noted: observed at exposure 3 (rear) and exposure 4 (east 94th street), balcony's under panels at various levels and various locations are loose, missing s

    Feb 13, 2018 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner. observed in basement caps for concealed fire sprinkler heads stuck to ceiling w/paint. remedy: repair &/or replace.

    Feb 13, 2018 · Penalty $500

    Resolve
  • Class - 2

    61x10,70o2-61x10)main line disconnect switch when shut "off" and back "on" elevator does "not" resume normal service, repair. 70o2)elevator pit dirty, clean.

    Oct 6, 2017

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner. observed on 8/18/17at above address sprinkler no gauges on any of the floors. photos tak en. rmdy: repair and or replace.

    Jul 18, 2017

    Resolve
  • Class - 2

    Failure to maintain bldg in code-compliant manner. observed on 7/18/17at above address no sprinkler heads in corridor of basement. rmdy: repair and/or replace.

    Jul 18, 2017 · Penalty $500

    Resolve
  • Class - 1

    Electrical work without a permit.observed in basement electrical room:the installation of main power distribution equipment prior to obtaining a permit.a total of 73 electric meters,4-400 amp and 4-200 amp disc

    Jul 18, 2017

    Resolve
  • Class - 1

    Electrical work without a permit.observed on roof:the installation of 73 air conditioning units and on hvac unit.electrical circuits,risers,disconnects that provide power to units were completed(installed)prior

    Jul 18, 2017 · Penalty $800

    Resolve
  • Class - 1

    Electrical work without a permit.observed in entire building:the installation of branch circuit wiring,electrical panels,heaters,receptacleslight fixtures,switches,switches prior to obtaining an electrical perm

    Jul 18, 2017

    Resolve
  • Class - 1

    Unapproved,unsafe,unsuitable electrical equipment,apparatus,devices,materials,appliances,or wiring in use.observed in roof:electrical boxes missing covers.as a result,high voltage cables carrying high amount of

    Jul 18, 2017 · Penalty $1,600

    Resolve
  • Class - 1

    Failure to maintain building in code-compliant manner.lack of a systemof automatic sprinklers where required per bc903.2;27-954.at the time of my inspection i observed in the cellar/basement,areas that were not

    Feb 1, 2017 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to comply w/the comm's order contained in nov #35214025h issued on 09/28/16 & to file a c of c pursuant to 28-201.1;28-204.4 & 1rcny102-01. remedy: comply w/comm's order &/or file a c of c.

    Nov 27, 2016 · Penalty $800

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner:failure to comply with law for drainage system per 702.1; 27-911. at time of my inspect ion, 9:45am, 928 16 at the above place of occurrence address i observ

    Sep 28, 2016 · Penalty $1,250

    Resolve
  • Class - 2

    Exit door not self closing. note: exit doors to roof at bulkhead a & b not self closing. remedy: repair/replace door.

    Sep 28, 2016 · Penalty $1,250

    Resolve
  • Class - 1

    Sec. 403.8 misc violations: fgc 403.8 unpainted gas piping not protected from elements. at the time of my inspection,9:45am on 9/28/16 at the above place of occurance address i observed on the roof unpainted

    Sep 28, 2016 · Penalty $4,000

    Resolve
  • Class - 2

    Failure to maintain bldg in code compliant manner: lack of emergency lighting for exits,exit discharges & public corridors per b1006.1;27-542. note: inoperative emergency lights w/battery back up at 7th fl corr

    Sep 28, 2016 · Penalty $1,250

    Resolve

Complaints

  • Heat/hot water

    Entire building

    Jul 31, 2026 · Apt 4A

    Close
  • Heat/hot water

    Entire building

    Apr 12, 2026 · Apt BLDG

    Close
  • Unsanitary condition

    Pests

    Oct 20, 2025 · Apt 7H

    Close
  • Unsanitary condition

    Pests

    Oct 19, 2025 · Apt 7H

    Close
  • Unsanitary condition

    Pests

    Oct 16, 2025 · Apt 7H

    Close
  • Unsanitary condition

    Pests

    Jul 15, 2025 · Apt 4I

    Close
  • Heat/hot water

    Entire building

    Jun 7, 2025 · Apt UNIT #

    Close
  • Heat/hot water

    Entire building

    Dec 22, 2024 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    May 20, 2023 · Apt 6I

    Close
  • Heat/hot water

    Entire building

    Apr 19, 2023 · Apt 6G

    Close
Show 27 more ↓
  • Heat/hot water

    Entire building

    Feb 28, 2023 · Apt 2B

    Close
  • Heat/hot water

    Entire building

    Jul 15, 2022 · Apt 7E

    Close
  • Safety

    Window guard broken/missing

    Mar 8, 2022 · Apt 2E

    Close
  • Heat/hot water

    Entire building

    Jan 31, 2022 · Apt 4G

    Close
  • Heat/hot water

    Apartment only

    Jan 16, 2022 · Apt 6C

    Close
  • Heat/hot water

    Entire building

    Nov 5, 2021 · Apt BLDG

    Close
  • Heat/hot water

    Apartment only

    Nov 15, 2018 · Apt 5C

    Close
  • Heat/hot water

    Entire building

    Mar 6, 2018 · Apt 1J

    Close
  • Heat/hot water

    Entire building

    Nov 14, 2017 · Apt 7F

    Close
  • Heat/hot water

    Entire building

    Aug 21, 2017 · Apt 2H

    Close
  • Plumbing

    Water supply

    Aug 20, 2017 · Apt 2H

    Close
  • Heat/hot water

    Entire building

    Aug 14, 2017 · Apt 2H

    Close
  • Water leak

    Slow leak

    Jul 20, 2016 · Apt 5I

    Close
  • Unsanitary condition

    Mold

    Jul 20, 2016 · Apt 5I

    Close
  • Plumbing

    Water supply

    Jul 20, 2016 · Apt 5I

    Close
  • Heat/hot water

    Entire building

    Jun 9, 2016 · Apt 4B

    Close
  • Heat/hot water

    Entire building

    Jun 8, 2016 · Apt 2I

    Close
  • Water leak

    Slow leak

    Apr 27, 2016 · Apt 5I

    Close
  • Water leak

    Damp spot

    Apr 27, 2016 · Apt 5I

    Close
  • Heat/hot water

    Entire building

    Mar 31, 2016 · Apt 6G

    Close
  • Heat/hot water

    Apartment only

    Oct 27, 2015 · Apt 4I

    Close
  • Heat/hot water

    Apartment only

    Oct 19, 2014 · Apt 4J

    Close
  • General

    Cooking gas

    Jun 17, 2014 · Apt 1B

    Close
  • Heat/hot water

    Entire building

    Jun 17, 2014 · Apt 1B

    Close
  • Heating

    Heat-plant

    Aug 29, 2013 · Apt 2B

    Close
  • Heating

    Heat related

    Sep 6, 2010 · Apt 6F

    Close
  • Heating

    Heat related

    Dec 4, 2009 · Apt 2A

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D7)
Year built
2007
Floors
7
Residential units
68
Building area
54,868 ft²
Lot area
22,278 ft²
Zoning
R6
Community board
317
Council district
41
Block / lot
4597 / 1
Assessed value
$6,002,550
Landmark / historic district
No

HPD registration #385264, last renewed Aug 20, 2025.

Questions about 1044 East New York Avenue

Who owns 1044 East New York Avenue?

The owner of record in NYC Department of City Planning PLUTO data is E.n.y. Plaza LLC.

Does 1044 East New York Avenue have violations?

Yes. NYC HPD has recorded 130 housing violations at this property.

Is 1044 East New York Avenue rent stabilized?

NYC Department of Finance tax bills listed 68 rent-stabilized units here in 2024 (about 100% of its 68 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 1044 East New York Avenue built?

City records list 2007 as the year it was built.

How many apartments are in 1044 East New York Avenue?

It has 68 residential units and 69 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.