378 Flushing Avenue
Brooklyn, NY 11205BBL 3-01884-0048Map
Owner of record: Flushing & Little Nassau LLC
378 Flushing Avenue is an elevator apartment building built in 2018 in Brooklyn, 11205. It has 122 residential units across 8 floors. The owner of record is Flushing & Little Nassau LLC. HPD has recorded 4 housing violations here, most recently on April 18, 2024. City tax records listed 2 rent-stabilized apartments here in 2022.
- HPD violations
- 4
- DOB violations
- 86
- ECB violations
- 82
- HPD complaints
- 1
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.
Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 4
- ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 18, 2024
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 17, 2023
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 4, 2022
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Mar 10, 2022
Closed — Violation dismissed
DOB building violations · 86
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 22, 2025
Dob violation - dismissed - Failure to post energy grade/score none
Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3
Dec 1, 2024
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 4, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed
Show 40 more ↓
- Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 22, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 2, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Feb 19, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Feb 19, 2020
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Feb 19, 2020
Dob violation - dismissed - Construction other optional
Addl info:peer review req:meeting held on 12/3/19 the owner&owners geo technical engr made it known the dewatering system wells&well points for the const site not operat adequat&the reasons are not known.owner retain pe knowledg/experienced w/dewatering const sites,to ivestigate& rept why dewatering not function properly.sub rept to borough commish
Dec 3, 2019
Dob violation - dismissed - Construction other optional
C-construction other optional
Nov 20, 2019
Vp*-violation unserved ecb- dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Nov 8, 2019
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Nov 8, 2019
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 17, 2019
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 4, 2018
Dob violation - resolved - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2016 inspection report
Apr 6, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 2, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 2, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 2, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 28, 2017
Dob violation - resolved - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2015 inspection report
Feb 24, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 11, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 10, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 10, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 10, 2016
Dob violation - resolved - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2014 inspection report
Oct 1, 2015
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
May 13, 2015
Dob violation - resolved
ECB violations · 82
- Class - 1
Failure to submit the required parking structure initial observation report for an existing parking structure or a periodic inspection of a parking structure(pips)report documenting the conditions of psid#b0000
Oct 1, 2024 · Penalty $1,250
Resolve - Class - 1
Work without a permit.note at time of inspection of above premises,observed on 1st and basement level in commercial space wwop.observed new electrical with new panels and new b/x,switches and outelts.new plumbi
Feb 27, 2023
Resolve - Class - 2
3307.2 failure to comply with dot stipulations.at time of inspection of a 7 story new building observed open construction debris container on the street.upon review of the dot permit#b02-2021223-d31 it was disc
Sep 17, 2021
Resolve - Class - 2
Failure to comply with manufacturer specifications.at time of inspection of a 7 story new building observed yodock barriers on the street atexp1.noticed yodocks not being locked in place or water filled.remedy:
Sep 17, 2021
Resolve - Class - 2
Construction fence expired permit at the time of my inspection i observed a construction fence in place upon further review of bis and dob now i saw that the permit for the fence has expired on 03-30-2021 all t
Jul 19, 2021
Resolve - Class - 1
No guardrails on support scaffold at the time of my inspection i observed workers on supported scaffold with no guardrails at expo 1 and 2.supported scaffolds should be maintained according to manufactruers sp
Jul 19, 2021 · Penalty $625
Resolve - Class - 2
Operation of a device without a certificate of compliance.
May 25, 2021
Resolve - Class - 1
Housekeeping note at the time of my inspection of a 8 story new building construction work in progress i observed large amount of construction garbage in rooms on various floors at various location materials an
May 25, 2021
Resolve - Class - 1
Operation of a device without a certificate of compliance
May 25, 2021
Resolve - Class - 1
Bc3303.14.1-standing water note at the time of my inspection of a 8 story new building construction work in progress i observed large amount water on teh sub cellar floor this creates a hazard for workers and
May 25, 2021 · Penalty $2,500
Resolve
Show 40 more ↓
- Class - 1
Bc3301.6.1 design of temp const @time of my insp,i observed approx25'lx12'w access ramp for personnel [email protected],there were no detail or plan drawings for it.core stip for worker&public safety,code stip
Mar 5, 2021
Resolve - Class - 1
Ac28-110.1 work contrary to site safety plan @time of my insp,i observed that const fence on sidewalk@exp1 was extended approx8' beyond property line of adjoining property@exp2&that sidewalk shed ended@exp2 pro
Mar 5, 2021
Resolve - Class - 2
Bc3303.4.2 inadequately covered debris containers.@time of my insp,i observed uncovered debris dumpster@exp1 filled above top rim.this posedminor haz to public sanitation.for public safety,code stips containers
Mar 5, 2021
Resolve - Class - 1
Watch person note:at time of my inspection of 7 story new building with a footprint area of 27,299 square feet,jobsite is closed and podlocked on both exposures one and two upon making inspection i observed tha
Feb 26, 2021 · Penalty $2,500
Resolve - Class - 2
Failure to comply with manufacturer specifications note at time of my inspection of 7 story new building jobsite is closed and padlocked.i observed barriers on streets at exposures#1 and 4 roadways by inspectio
Feb 26, 2021
Resolve - Class - 2
Failure to comply with nys eo#202.68 and nys doh guidelines.at time ofinspection of active construction on a 7 story new building i observedworkers not wearing masks throughout jobsite.compedent person failed t
Feb 8, 2021 · Penalty $625
Resolve - Class - 2
Pedestrian protection doesn't meet code specs-lighting-note:@time of insp it was observed a few lights not illuminated on underside of sidewalk shed.underside of sidewalk shed shall be illuminated@all times eit
Feb 4, 2021 · Penalty $2,400
Resolve - Class - 2
Bc 3301.13.12 failure to designate competent person. at time of inspection of a 7 sty nb currently at roof level on an active site,cs not onsite comp person on site mr. pawlikowski. upon review of cs log provid
Nov 4, 2020
Resolve - Class - 2
Bc 3301.13.13 failure to maintain adequate cs daily log book. at time of inspection of a 7 sty nb currently at roof level on an active site,cs not on site competent person on site mr. pawlikowski. upon review o
Nov 4, 2020
Resolve - Class - 2
Work does not conform to approved construction documents. at time of inspection of a 7 sty nb currently at roof level bulkheads not completed i observed work over roof which is 8th fl not conforming to approved
Nov 4, 2020
Resolve - Class - 1
Work does not conform to approved construction documents. at time of inspection of a 7 sty nb currently at roof level bulkheads and roof above 8th fl not completed and no hoist in readiness for fdny use in plac
Nov 4, 2020 · Penalty $2,500
Resolve - Class - 1
Bc 3303.12.2 failure to provide hoist 1 elevator @time of inspection of a 8 sty nb partially @roof level i observed no hoist @elevator in place for fire department use as required. stop all work avobe 77th sty.
May 22, 2020 · Penalty $2,500
Resolve - Class - 1
Bc 3308.7 failure to provide guardrail system @time of inspection of a8 sty nb partially @roof lvl i observed opening @2nd floor unenclosed perimeter & no guardrail system in place as required to prevent person
May 22, 2020 · Penalty $2,500
Resolve - Class - 1
Bc 3307.4 inadequate work & storage zone @time of inspection of a 8 sty. nb partially @roof lvl i observed inadequate barriers in place @work/storage zone @exp#1&2 to enclose & contain operations as required
May 22, 2020 · Penalty $2,500
Resolve - Class - 1
Failure to immediately notify the dept of an accident. @time of inspection of a 9 sty nb currently @2nd floor in response to incident reported by fdny during concrete pour section of 2nd sloor wet salb collapse
May 22, 2020 · Penalty $5,000
Resolve - Class - 1
Construction super failed to perform duties as per code. @time of inspection of a 9 sty nb currently @2nd floor in response to incident reported by fdny during concrete pour section of 2nd floor wet slab
May 22, 2020 · Penalty $10,000
Resolve - Class - 1
Bc3301.2 failure to institute/maintain adequate safety measures-rebar caps @time of inspection of a 8 sty nb partially @roof lvl i observed misssing reabr caps @multiple locations that pose impalement hazard to
May 22, 2020
Resolve - Class - 1
Failure to safeguard public & property. @time of inspection of a 9 stynb currently @2nd floor i observed no overhaed protection or any othersafety measures in place provided to safegaurd public @sidewalk corner
May 22, 2020
Resolve - Class - 1
Bc 3307.4 inadequate work/storage zone @time of inspection of a 9 sty nb currently @2nd floor i observed, work & storage zone @roadway exp#1 & inadequate barrriers provided to enclose & contain operations as
May 22, 2020
Resolve - Class - 1
Sec. 3309.14 failure to provide protection of windows. at time of inspection of a 8 sty bldg partially at roof level i observed no window protection in place for adjoining property at exp#3 as required by code
May 22, 2020
Resolve - Class - 1
Bc 3309.14 failure to provide protection of windows. @time of inspection of a 9 sty nb currently @2nd floor i observed no window protection in place for adjoining property @from damage @all times. stop all work
May 22, 2020
Resolve - Class - 1
Failure to safeguard public & property. at time of inspection of a 7 sty nb currently at foundation stage active concrete operations at roadway exp#1&2,i observed concrete trucks being washed at roadway exp#2
Apr 7, 2020 · Penalty $10,000
Resolve - Class - 1
Failure to file evidence of compliance w/disability benefits law. at time of inspection of a 7 sty nb currently at foundation stage concreteoperations in progress upon review of dept records,i observed disabili
Apr 7, 2020 · Penalty $5,000
Resolve - Class - 1
Work w/o a permit. at time of inspection of a 7 sty nb currently at foundation stage active concrete operations in progress concrete slab & formwork for subcellars being erected upon review of dept records no
Apr 7, 2020
Resolve - Class - 1
Work without a permit.at the time of my inspection i observed a 7 story building on premises upon research in bis and requesting the superintendent owner and competent person to provide a nb permit for the alre
Nov 21, 2019
Resolve - Class - 1
Bc3304.4.5/placement of excavation equipment/excavated material at time of inspection it was observed heavy equipment excavator in operationon piled of soil approx 12ft above foundation while another excavator
Nov 21, 2019
Resolve - Class - 1
Failure to maintain safety operations at the time of inspection i observed an excavator on top of excavated soil approx 12 ft high warning above another excavator at the bottom of the soil pile no seperation or
Nov 21, 2019
Resolve - Class - 2
28-105.5/form filed with dept or buildings do not have required signatures or no filed and without scan code as noted:at time of site visit inspection concrete cast-in-place part-b building was completed to flr
Nov 21, 2019 · Penalty $625
Resolve - Class - 1
Bc3304.7/acess,ingress,egress at excavation level;at the time of my inspection i observed work performed at excavation level approx 30ft below grade a make shift ladder provided for access to ingress/egress fro
Nov 21, 2019 · Penalty $2,500
Resolve - Class - 2
Bc3307.2.1/failure to comply with dot regulations;at the time of my inspection i observed materials placed in the traffic lanes adjacent to explosure 1 and 2 upon request dot permits provided.permits stipulated
Nov 21, 2019
Resolve - Class - 2
Conditions of fence;at the time of my inspection;i observed the construction fence at exposures 1 and 2 leaning,not plumb with bills posted all overs also some panels placed uneven and in need of repair.rem:pro
Nov 21, 2019
Resolve - Class - 1
Bc3308.6/horizontal safety netting;at the time of my inspection i observed a 7 story building on premises with form stripping operation on going at 6th and 7th floors without horizontal netting provided as requ
Nov 21, 2019 · Penalty $2,500
Resolve - Class - 1
Work contrary to construction documents.at the time of my inspection iobserved an excavated area where piles and lagging have been placed upon request for the plans to show site conditions as is none was provid
Nov 21, 2019
Resolve - Class - 2
Bc3301.7/failure to provide p.e. design drawing-shore/reshore schedule.as noted:at time of inspection observed reshores were removed at center of structure at floors 5,6 and 7 a reshore schedule was not provide
Nov 21, 2019
Resolve - Class - 2
Work doest not conform to approved construction documents at time of my inspection,i observed a excavation/foundation phase of a project on going. i noted at exp#3(fronting"little nassau street"the lower level
Oct 29, 2019
Resolve - Class - 2
Sec. 3304.4.5 failure to adhere to bldg code in requards to placing foundation work equipment. at time of my inspection i observed a construction ramp/staging area at sidewalk grade exp#1. at this location i no
Oct 29, 2019
Resolve - Class - 2
Bc3303.4.6/3313.1/improper storage of compressed gas cannisters at time of my inspection i observed a excavation site with a stockpile at exposure #1 within this stockpile i observed a "welding cart" with two c
Oct 29, 2019
Resolve - Class - 2
Bc3301.2/failure to provide guardrail at excavation site at time of inspection i observed a stockpile point at grade elevation directly adjacent to this is a camp and sal germ with a steep slope.guardrail prote
Oct 29, 2019
Resolve - Class - 2
Construction superintendent failure to perform duties as per code.at time of my inspection i observed a inadaquately filled log book with signtures missing for 10/29,10/28 and 10/27 i have also observed the fol
Oct 29, 2019 · Penalty $2,500
Resolve - Class - 1
Work w/o a permit. as noted: based on my review of the special inspection report dated 9-9-19,respodent was constructing concrete columns toadd the 1st sty & support the 2nd fl w/o a validly issued permit. this
Oct 24, 2019
Resolve
Complaints
- Door/window
Door
Oct 18, 2025 · Apt 2A
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Elevator apartment building (D1)
- Year built
- 2018
- Floors
- 8
- Residential units
- 122
- Building area
- 111,166 ft²
- Lot area
- 25,109 ft²
- Zoning
- R7A
- Community board
- 303
- Council district
- 33
- Block / lot
- 1884 / 48
- Assessed value
- $11,165,400
- Landmark / historic district
- No
HPD registration #390028, last renewed Aug 27, 2025.
Questions about 378 Flushing Avenue
Who owns 378 Flushing Avenue?
The owner of record in NYC Department of City Planning PLUTO data is Flushing & Little Nassau LLC.
Does 378 Flushing Avenue have violations?
Yes. NYC HPD has recorded 4 housing violations at this property.
Is 378 Flushing Avenue rent stabilized?
NYC Department of Finance tax bills listed 2 rent-stabilized units here in 2022 (about 2% of its 122 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.
When was 378 Flushing Avenue built?
City records list 2018 as the year it was built.
How many apartments are in 378 Flushing Avenue?
It has 122 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.