roofy

103 Schenectady Avenue

Brooklyn, NY 11213BBL 3-01348-0006Map

Owner of record: 103 Brooklyn LLC

103 Schenectady Avenue is a walk-up apartment building built in 2021 in Brooklyn, 11213. It has 7 residential units across 4 floors. The owner of record is 103 Brooklyn LLC. HPD has no housing violations on record for this property. City tax records listed 3 rent-stabilized apartments here in 2024.

HPD violations
0
DOB violations
1
ECB violations
18
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
3
About 43% of the building's 7 apartments
Down from 7 in 2023

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 1

  • Construction other optional

    C-construction other optional

    Jan 27, 2003

    Dob violation - dismissed

ECB violations · 18

  • Class - 2

    Construction superintendent failed to perform duties per code.as noted:at time of inspection at active jobsite observed work being done in cellar requset of person in charge competent person or constr super non

    Apr 28, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    28-407.1 failure to provide welder's license for welding at job site. as noted at time of my inspection observed work in rear yard,of install stairs & rails an inquirery for the welder & license none was provid

    Feb 16, 2022 · Penalty $625

    Resolve
  • Class - 1

    Manufactures specifications(c-joist)at time of inspeciton of an active4 sty nb with approx 10 workers on site.i requested for manufactors specifications for cold form steel in place(c-joist)none was provided.gc

    Nov 17, 2021 · Penalty $625

    Resolve
  • Class - 1

    Work contrary to plans(structual c-joist)at tim eof inspeciton of an active 4 sty nb with approx 10 workers on site,i requested for structual plans for cold form steel (c-joist) provided byt inadequate plans st

    Nov 17, 2021 · Penalty $625

    Resolve
  • Class - 1

    Pre-task/inadequate(construct provided)at time of inspection of an 4 sty nb@roof level with approx 10 workers on-site.i requested for pre task provied but inadequate.pre-task had no indication of who provided t

    Nov 17, 2021 · Penalty $625

    Resolve
  • Class - 2

    Required signs(parapet)at time of inspection of an active 4 sty nb with approx 10 workers on site i observed sidewalk shed in place exp1 without requires information panel.i requested for plans fr sws plans pro

    Nov 17, 2021

    Resolve
  • Class - 2

    Competent person(failure to desymate)at the of inspect of an active 4 sty nb with approx 10 workers on site,i observed in construction superintendent log book,no mention of any ones to be designated to take cou

    Nov 17, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    Fialure to institute safety measures(guardrails)at time of inspection of an active 4 sty nb@roof level i observed inadequate guardrails in place for balconies,window openings & leading perimeter edge at exp1&3,

    Nov 17, 2021 · Penalty $625

    Resolve
  • Class - 1

    Documents to be kept on site(sws plans)at time of inspection of an active 4 sty nb with apprx 10 workers on site i requested for sidewalk shed plans for sws located exp1 plans was provided for another job locat

    Nov 17, 2021 · Penalty $625

    Resolve
  • Class - 2

    Failure to safeguard all person and property affected by construction.note:at the time of my inspection of an 7 story building with construction work in progress at 4 floor level.i observed two work at leading

    Nov 1, 2021

    Resolve
Show 8 more ↓
  • Class - 1

    Failure to communicate required information to worker during pre-shiftsafety meeting.note:at the time of my inspection oof 7 story building with activity work in progress.upon review document of pre-shift meeti

    Nov 1, 2021

    Resolve
  • Class - 2

    Bc 3307.2.1 failure to comply w/dot regulations note:at the time of myinspection of a 4 story building at 4 floor level with active work in progress i observed at exposure one a book truck delivery with sand an

    Nov 1, 2021

    Resolve
  • Class - 1

    Bc 3307.4.7 work and storage note:at the time of my inspection of an 4story building with construction work in progress.i observed at exposure one a boom truck are loan construction metiale to 4 floor level.i a

    Nov 1, 2021 · Penalty $625

    Resolve
  • Class - 1

    Bc2104.6 failure to provide masonry cmu block wall construction bracing accordance with tms 602/aci 530.1/asce 6 section 3.3r.as noted:at time of inspection at active construction site observed cmu block masonr

    Sep 10, 2021 · Penalty $625

    Resolve
  • Class - 2

    Work does not conform to approved pe construction documents.as noted: at time of inspection at active construction site observed #5 vertical bars in all shear walls.upon request of cmu details for shear walls o

    Sep 10, 2021

    Resolve
  • Class - 1

    Bc3301.13.12=failure to have copetent person at the site note at the time of my isnepction on active no superintendent present on site i ask d if there was a competent person on site the workers responsed no t

    Jul 20, 2021 · Penalty $625

    Resolve
  • Class - 2

    Bc28-105.5-forms filed with dept of buildings do not have required signature as noted at time of my inspection observed at exposure #2&3 concrete of new foundation wall tr1 , tr2 and tr3 all

    Jul 20, 2021

    Resolve
  • Class - 2

    Sidewalk shed lighting. note: at time of my inspection of a demolitionsite no work in progress. i observed at 5:30am that the sidewalk shed lighting was not illuminated & walking beneath was dark sunrise for to

    Mar 4, 2021

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Walk-up apartment building (C1)
Year built
2021
Floors
4
Residential units
7
Building area
5,866 ft²
Lot area
2,300 ft²
Zoning
R6
Community board
308
Council district
36
Block / lot
1348 / 6
Assessed value
$540,000
Landmark / historic district
No

HPD registration #390754, last renewed Aug 23, 2025.

Questions about 103 Schenectady Avenue

Who owns 103 Schenectady Avenue?

The owner of record in NYC Department of City Planning PLUTO data is 103 Brooklyn LLC.

Does 103 Schenectady Avenue have violations?

NYC HPD has no housing violations on record for this property.

Is 103 Schenectady Avenue rent stabilized?

NYC Department of Finance tax bills listed 3 rent-stabilized units here in 2024 (about 43% of its 7 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 103 Schenectady Avenue built?

City records list 2021 as the year it was built.

How many apartments are in 103 Schenectady Avenue?

It has 7 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.