127 Concord Street
Brooklyn, NY 11201BBL 3-00107-0048Map
Owner of record: 127 Concord Realty LLC
127 Concord Street is an elevator apartment building built in 2023 in Brooklyn, 11201. It has 73 residential units across 13 floors. The owner of record is 127 Concord Realty LLC. HPD has recorded 37 housing violations here, most recently on September 26, 2026. 21 of the 37 most recent violations are still open. City tax records listed 49 rent-stabilized apartments here in 2024.
- HPD violations
- 37
- DOB violations
- 0
- ECB violations
- 23
- HPD complaints
- 30
What to know
Immediately hazardous issues among recent violations are still open.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.
Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 37
- BHazardous
Properly repair with similar material the broken or defective wood floor tile in the kitchen located at apt 3d, 3rd story, 1st apartment from south at west , section at north
Sep 26, 2026 · Apt 3D
Open — Nov sent out - BHazardous
Properly repair with similar material the broken or defective caulking around bathtub in the bathroom located at apt 3d, 3rd story, 1st apartment from south at west , section at north
Sep 26, 2026 · Apt 3D
Open — Nov sent out - BHazardous
Properly repair the source and abate the evidence of a water leak at ceiling in the bathroom located at apt 3d, 3rd story, 1st apartment from south at west , section at north
Sep 26, 2026 · Apt 3D
Open — Nov sent out - BHazardous
Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling in the bathroom located at apt 3d, 3rd story, 1st apartment from south at west , section at north
Sep 26, 2026 · Apt 3D
Open — Nov sent out - BHazardous
Repair, replace or provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations defective in the entire apartment located at apt 3d, 3rd story, 1st apartment from south at west , section at north
Sep 26, 2026 · Apt 3D
Open — Nov sent out - BHazardous
Repair, replace or provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules defective in the entire apartment located at apt 3d, 3rd story, 1st apartment from south at west , section at north
Sep 26, 2026 · Apt 3D
Open — Nov sent out - CImmediately hazardous
Abate the infestation consisting of roaches in the entire apartment located at apt 3d, 3rd story, 1st apartment from south at west , section at north
Sep 26, 2026 · Apt 3D
Open — Notice of issuance sent to tenant - ANon-hazardous
Properly repair with similar material the broken or defective caulking around bathtub in the bathroom located at apt 3d, 3rd story, 1st apartment from south at west
Sep 19, 2026 · Apt 3D
Open — Nov sent out - CImmediately hazardous
Properly repair with similar material the broken or defective wood floor in the kitchen located at apt 3d, 3rd story, 1st apartment from south at west
Sep 19, 2026 · Apt 3D
Open — Nov sent out - BHazardous
Repair, replace or provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations defective in the entire apartment located at apt 3d, 3rd story, 1st apartment from south at west
Sep 19, 2026 · Apt 3D
Open — Nov sent out
Show 27 more ↓
- BHazardous
Repair, replace or provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules defective in the entire apartment located at apt 3d, 3rd story, 1st apartment from south at west
Sep 19, 2026 · Apt 3D
Open — Nov sent out - CImmediately hazardous
Abate the infestation consisting of roaches in the entire apartment located at apt 3d, 3rd story, 1st apartment from south at west
Sep 19, 2026 · Apt 3D
Open — Notice of issuance sent to tenant - BHazardous
Repair, replace or provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations defective in the entire apartment located at apt 3d, 3rd story, 1st apartment from west at north
Sep 4, 2026 · Apt 3D
Open — Nov sent out - BHazardous
Repair, replace or provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules defective in the entire apartment located at apt 3d, 3rd story, 1st apartment from west at north
Sep 4, 2026 · Apt 3D
Open — Nov sent out - CImmediately hazardous
Properly repair with similar material the broken or defective wood floor in the kitchen located at apt 3d, 3rd story, 1st apartment from west at north
Aug 13, 2026 · Apt 3D
Open — Civ14 mailed - BHazardous
Properly repair with similar material the broken or defective metal door frame at door in the 3rd room from east located at apt 3d, 3rd story, 1st apartment from west at north
Aug 13, 2026 · Apt 3D
Open — Civ14 mailed - ANon-hazardous
Paint with light colored paint to the satisfaction of this department all walls and ceiling in the entire apartment located at apt 3d, 3rd story, 1st apartment from west at north
Aug 13, 2026 · Apt 3D
Open — Nov sent out - ANon-hazardous
Properly repair with similar material the broken or defective caulking around bathtub in the bathroom located at apt 3d, 3rd story, 1st apartment from west at north
Aug 13, 2026 · Apt 3D
Open — Civ14 mailed - BHazardous
Properly repair or replace the broken or defective door knob at the entrance in the 4th room from east located at apt 3d, 3rd story, 1st apartment from west at north
Aug 13, 2026 · Apt 3D
Open — Civ14 mailed - CImmediately hazardous
Abate the infestation consisting of roaches in the entire apartment located at apt 3d, 3rd story, 1st apartment from west at north
Aug 13, 2026 · Apt 3D
Open — Not complied with - ANon-hazardous
§ 329, m/d law and dept. rules and regs. provide a completed certificate of inspection visits in a proper frame at or near mailboxes, bottom edge of frame between 48-62 inches above floor missing at public hall
Aug 12, 2026
Open — Nov sent out - ANon-hazardous
§ 329, m/d law and dept. rules and regs. provide a completed certificate of inspection visits in a proper frame at or near mailboxes, bottom edge of frame between 48-62 inches above floor [ missing frame ] at public hall, 1st story
Apr 29, 2026
Closed — Violation dismissed - ANon-hazardous
Post a proper notice of smoke detector requirements, in a form approved by the commissioner, at or near the mailbox [ missing notice ] at public hall, 1st story
Apr 29, 2026
Closed — Violation dismissed - ANon-hazardous
Post a proper notice of carbon monoxide detecting device requirements, in a form approved by commissioner, in a common area of a class a multiple dwelling near inspection certificate or provide notice to tenants in private dwellings [ missing notice ]
Apr 29, 2026
Closed — Violation dismissed - ANon-hazardous
Post, in a form approved by the commissioner, and maintain a notice in a common area of the building regarding the procedures that should be followed when a gas leak is suspected
Apr 29, 2026
Closed — Violation dismissed - ANon-hazardous
Post and maintain a proper notice on wall of the entrance story in english and spanish on the availability of the agencys housing information guide. a sample notice can be found at www.nyc.gov/hpd.
Apr 29, 2026
Closed — Violation dismissed - ANon-hazardous
Post and maintain a proper sign on wall of entrance story showing the registration number assigned by the department and the address of the building. at public hall, 1st story
Apr 29, 2026
Closed — Violation dismissed - CImmediately hazardous
Abate the infestation consisting of roaches in the entire apartment located at apt 4d, 4th story, 1st apartment from south at west
Apr 29, 2026 · Apt 4D
Closed — Violation dismissed - ANon-hazardous
§ 329, m/d law and dept. rules and regs. provide a completed certificate of inspection visits in a proper frame at or near mailboxes, bottom edge of frame between 48-62 inches above floor missing at public hall
Apr 24, 2026
Closed — Violation dismissed - ANon-hazardous
Post and maintain a proper sign on wall of entrance story showing the registration number assigned by the department and the address of the building. at public hall
Apr 24, 2026
Closed — Violation dismissed - ANon-hazardous
Post and maintain a proper notice on wall of the entrance story in english and spanish on the availability of the agencys housing information guide. a sample notice can be found at www.nyc.gov/hpd. at public hall
Apr 24, 2026
Closed — Violation dismissed - ANon-hazardous
Post a proper notice of smoke detector requirements, in a form approved by the commissioner, at or near the mailbox missing at public hall
Apr 24, 2026
Closed — Violation dismissed - ANon-hazardous
Post a proper notice of carbon monoxide detecting device requirements, in a form approved by commissioner, in a common area of a class a multiple dwelling near inspection certificate or provide notice to tenants in private dwellings missing
Apr 24, 2026
Closed — Violation dismissed - ANon-hazardous
Post sign on wall of entrance story bearing name, address including apartment number if any, and telephone number of superintendent, janitor or housekeeper. at public hall
Apr 24, 2026
Closed — Violation dismissed - ANon-hazardous
Post, in a form approved by the commissioner, and maintain a notice in a common area of the building regarding the procedures that should be followed when a gas leak is suspected at public hall
Apr 24, 2026
Closed — Violation dismissed - CImmediately hazardous
Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system missing at public hall
Apr 24, 2026
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 18, 2024
Closed — Violation dismissed
DOB building violations · 0
No DOB violations on record
ECB violations · 23
- Class - 2
After hours work without a variance. at time of inspection work was being performed throughout entire premises with after hours variance., obtain after hours variance
Sep 9, 2023 · Penalty $1,250
Resolve - Class - 2
At the time of inspection 13 stories nb observed needle beams @ exp#4 taking load of support scaffold above ~75 ft high was not conform to approved design drawing space between 5th-6th beam more than 16 feet, m
Jun 13, 2023 · Penalty $620
Resolve - Class - 2
Responding a complaint observed: sidewalk shed with valid permit# b00736772-i1-sh installed at expo# 2-3 contrary to approved drawings and color code. sidewalk shed in white color and missing steel angle bracin
May 12, 2023
Resolve - Class - 1
13 story concrete nb, i observed active site at 11fl working level, with scaffold alternative to horizontal netting at exp1, 3&4. scaffold does not reach the working level as required by code, but it ends 2 flo
May 10, 2023 · Penalty $625
Resolve - Class - 2
13 story nb, i observed active site, with sidewalk shed(sws) at exp3 not having 8f min height,(3307.6.4.7) has 1 leg partially on roadway, no high visibility marking, sws at exp1 has storage of materials, upon
May 10, 2023 · Penalty $2,400
Resolve - Class - 2
13 story concrete nb, i observed active site with 1 worker installing formwork column at the 10fl working floor above guardrail height. upon closer inspection, it was revealed that worker was tied off to a form
May 10, 2023
Resolve - Class - 1
13 story concrete nb, i observed active site currently forming 11fl working deck. standpipe riser ends on 7floor and is air pressurized. upon request to the ssc to view the hydrostatic test at 75f, ssc told me
May 10, 2023 · Penalty $312
Resolve - Class - 2
13 story concrete nb, i observed active site with work at 11fl working deck. no window protection at exp2 adjoining property, which is in a distance less than 20f perpendicular from heavy construction activitie
May 10, 2023
Resolve - Class - 2
At time of inspection at an active job site, i observed the new building was erecting the 6th floor which is 1 floor above the adjacent property roof at exposure #4 without installing roof protection as per sit
Apr 19, 2023
Resolve - Class - 2
At the time of my inspection of a 13 story new building construction in progress at the 5 floor level, i observed sidewalk shed in place at exposure #1 and 4 painted in white and not hunter green, this creates
Apr 17, 2023 · Penalty $625
Resolve
Show 13 more ↓
- Class - 1
At the time of my inspection of a 13 story new building construction in progress at the 5 floor level, i observed fire escape at exposure 1 and 4 entrance was blocked off by construction fence. this creates a h
Apr 17, 2023 · Penalty $500
Resolve - Class - 1
At the time of my inspection of a 13 story new building construction in progress at the 5 floor level, i observed overhead protection/sidewalk shed at exposure #3& 4 were not according to approved documents, no
Apr 17, 2023 · Penalty $625
Resolve - Class - 2
No en drawing and com/check approved from dob provided on the job site at the time of inspection., provide approved /accepted construction documents; please go to https://www1.nyc.gov/site/buildings/codes/energ
Apr 13, 2023
Resolve - Class - 1
At the time of my inspection of a13 story new building at foundation/excavation phase, i observed at exposure #2 a 12" waler on piles and no raker attach to it as was shown on approved soe plans this creates a
Mar 7, 2023 · Penalty $625
Resolve - Class - 1
At the time of my inspection of a13 story new building at foundation/excavation phase,i observed on street one concrete pump truck and 2 concrete cement truck on street at exposure #1 blocking the entire street
Mar 3, 2023 · Penalty $6,250
Resolve - Class - 1
At the time of my inspection of a13 story new building at foundation/excavation phase, i observed on street at exposure #1 concrete washout box. upon request for dot permit none was provided or at job site. thi
Mar 3, 2023 · Penalty $625
Resolve - Class - 1
At the time of my inspection of a13 story new building at foundation/excavation phase, i observed yodock system on street at exposure #1 and they were not filled or attached together according to manufacture sp
Mar 3, 2023 · Penalty $1,250
Resolve - Class - 1
At the time of my inspection of a 13 story new building at foundation/excavation phase, upon request and review of site safety orientation records and refresher they were missing the contents, date, job locatio
Mar 3, 2023 · Penalty $12,500
Resolve - Class - 1
Work does not conform to approved construction documents.at the time of my inspection of a proposed 13 story new building,i observed a berm in place at exp2 203 jay street foundation wall.this berm runs along t
Jan 20, 2023 · Penalty $625
Resolve - Class - 2
Observed active demolition site at ground level with first floor walls demo in progress and observed 8ft construction fence missing at exp 2 and 4 as required, which creates a hazard for public and adjoining pr
Nov 16, 2022
Resolve - Class - 2
At time of inspection of class 1 violation #39501805x issued on 05/31/22 work does not conform to approved construction documents or approved amendment. site is closed unable to verify condition. upon checking
Nov 2, 2022 · Penalty $625
Resolve - Class - 2
Violation 39501805x was issued on 05.31.2022 for non-conforming demo work without providing overhead protection at all exposures. at the time of inspection, job site was inactive and could not observed installe
Oct 13, 2022 · Penalty $625
Resolve - Class - 1
Work does not conform to approved construction documents and/or approved amendments.observed demolition operation taken plase with no overhead protection at expo#2-3-4 .building roof was remove .stop all demoli
May 31, 2022 · Penalty $2,500
Resolve
Complaints
- Door/window
Door
Oct 2, 2026 · Apt BLDG
Open - Unsanitary condition
Pests
Sep 29, 2026 · Apt 3D
Close - Paint/plaster
Wall
Sep 29, 2026 · Apt 3D
Close - Door/window
Door
Sep 29, 2026 · Apt 3D
Close - Unsanitary condition
Mold
Sep 29, 2026 · Apt 3D
Close - Flooring/stairs
Floor
Sep 29, 2026 · Apt 3D
Close - Unsanitary condition
Mold
Sep 15, 2026 · Apt 3D
Close - Unsanitary condition
Pests
Sep 15, 2026 · Apt 3D
Close - Flooring/stairs
Floor
Sep 15, 2026 · Apt 3D
Close - Unsanitary condition
Pests
Aug 25, 2026 · Apt 4D
Close
Show 20 more ↓
- Unsanitary condition
Pests
Aug 5, 2026 · Apt 3D
Close - Unsanitary condition
Mold
Aug 5, 2026 · Apt 3D
Close - Door/window
Door
Aug 5, 2026 · Apt 3D
Close - Paint/plaster
Wall
Aug 5, 2026 · Apt 3D
Close - Paint/plaster
Wall
Aug 5, 2026 · Apt 3D
Close - Flooring/stairs
Floor
Aug 5, 2026 · Apt 3D
Close - Unsanitary condition
Pests
Jul 28, 2026 · Apt 4D
Close - Unsanitary condition
Pests
Apr 24, 2026 · Apt 4D
Close - Unsanitary condition
Pests
Apr 15, 2026 · Apt 4D
Close - Electric
Outlet/switch
Jan 6, 2026 · Apt 3D
Close - Flooring/stairs
Floor
Jan 6, 2026 · Apt 3D
Close - Unsanitary condition
Mold
Jan 6, 2026 · Apt 3D
Close - Paint/plaster
Wall
Jan 6, 2026 · Apt 3D
Close - Paint/plaster
Ceiling
Jan 6, 2026 · Apt 3D
Close - Flooring/stairs
Floor
Jan 4, 2026 · Apt 7D
Close - Water leak
Slow leak
Jan 4, 2026 · Apt 7D
Close - Electric
Lighting
Jan 4, 2026 · Apt 7D
Close - Plumbing
Toilet
Jan 4, 2026 · Apt 7D
Close - Water leak
Slow leak
Nov 21, 2025 · Apt 3D
Close - Flooring/stairs
Floor
Nov 21, 2025 · Apt 3D
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Elevator apartment building (D6)
- Year built
- 2023
- Floors
- 13
- Residential units
- 73
- Building area
- 64,987 ft²
- Lot area
- 6,900 ft²
- Zoning
- C6-2
- Community board
- 302
- Council district
- 33
- Block / lot
- 107 / 48
- Assessed value
- $10,509,750
- Landmark / historic district
- No
HPD registration #391058, last renewed Aug 24, 2025.
Questions about 127 Concord Street
Who owns 127 Concord Street?
The owner of record in NYC Department of City Planning PLUTO data is 127 Concord Realty LLC.
Does 127 Concord Street have violations?
Yes. NYC HPD has recorded 37 housing violations at this property.
Is 127 Concord Street rent stabilized?
NYC Department of Finance tax bills listed 49 rent-stabilized units here in 2024 (about 67% of its 73 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.
When was 127 Concord Street built?
City records list 2023 as the year it was built.
How many apartments are in 127 Concord Street?
It has 73 residential units and 74 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.