roofy

3633 Kingsbridge Avenue

Bronx, NY 10463BBL 2-05766-0882Map

Owner of record: Egerton LLC

3633 Kingsbridge Avenue is a walk-up apartment building built in 2022 in Bronx, 10463. It has 9 residential units across 3 floors. The owner of record is Egerton LLC. HPD has no housing violations on record for this property. City tax records listed 9 rent-stabilized apartments here in 2024.

HPD violations
0
DOB violations
0
ECB violations
18
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
9
About 100% of the building's 9 apartments

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 0

No DOB violations on record

ECB violations · 18

  • Class - 1

    At a 3 story new building active jobsite with approx. 6 workers. i noticed that from basement level up to roof level at all staircases no temporary handrail are installed. this creates a unsafe situation for wo

    Aug 11, 2023 · Penalty $2,500

    Resolve
  • Class - 1

    At time of my inspection of a 3 story building with a pipe scaffold at exposure#3 approx. 30 ft in height.i noticed 3 worker on pipe scaffold is missing guardrail system 3314.8.1 at all location where its neede

    Aug 11, 2023 · Penalty $2,500

    Resolve
  • Class - 2

    At a 3 story building active construction site approx. 6 worker. i noticed at 1 floor level inadequate housekeeping, i noticed at rear yard large amount of pieces of bricks, styrofoam and debri. this creates

    Aug 11, 2023 · Penalty $1,250

    Resolve
  • Class - 2

    At a active 3 story building with approx.6 workers. upon requesting for competent person or superintendent of jobsite none was available. i noticed inadequate log books and no super visits to ensure jobsite in

    Aug 11, 2023 · Penalty $2,500

    Resolve
  • Class - 1

    At time of my inspection i requested from workers on pipe scaffold for with their training certifications on pipe scaffold usage. none was made available and they informed me they didn't have any.this creates a

    Aug 11, 2023 · Penalty $5,000

    Resolve
  • Class - 1

    At a 3 story building with pipe scaffold approx. 30 feet in height.i noticed 3 worker on pipe scaffold with missing planking where stair towers are located,missing planking at working deck and unsecured as per

    Aug 11, 2023 · Penalty $1,250

    Resolve
  • Class - 1

    Observed supported pipe scaffolding at exposures 2,3&4 approx. 30 ft at jobsite. upon inspection it was observed that scaffold was not built in code compliance with missing toe boards,missing guard rails,planks

    May 3, 2023 · Penalty $2,500

    Resolve
  • Class - 1

    Observed inadequate guard rail system at exposure 1 setback. the guard rail system consist on cable system missing zero cables as per bc3308.5.3.1 zero cables shall be secured to the deck and be maintained in c

    May 3, 2023 · Penalty $2,500

    Resolve
  • Class - 2

    Observed multiple inadequate fire extinguishers on active jobsite. the said fire extinguishers have pulled pins, discharged, missing fdny inspection tags and are not elevated of graound as per fdny code.comply

    May 3, 2023 · Penalty $620

    Resolve
  • Class - 1

    Observed multiple violating conditions on nb jobsite 220711264 consisting of pipe scaffolding not in code compliance,inadequate fire extinguishers, inadequate guard rails and missing documents onsite. upon revi

    May 3, 2023 · Penalty $10,000

    Resolve
Show 8 more ↓
  • Class - 2

    Observed sidewalk shed at exposure 1 of jobsite approx. 10ft in height. upon request for approve drawings and letter of completion, none were provided at time of inspectionmaintain/display sidewalk shed drawing

    May 3, 2023 · Penalty $625

    Resolve
  • Class - 1

    It was observed a beta material hoist installed on top of supported pipe scaffold at exposure 4.requested for manufacture specs and designed drawings none were provided. the contractor or other entity causing t

    May 3, 2023 · Penalty $625

    Resolve
  • Class - 2

    At time of inspection on a non-active jobsite currently in superstructure phase, i observed a project information panel for demolition of a building installed on the construction fence, however the job is alrea

    Oct 15, 2022 · Penalty $1,250

    Resolve
  • Class - 2

    At the time of my inspection on a non-active jobsite, i observed a construction fence in place at exposure #1 with a viewing panel that was not blocked/protected with plexiglass or an equivalent nonfrangible ma

    Oct 15, 2022 · Penalty $1,000

    Resolve
  • Class - 1

    At time of my inspection i observe building under construction at 3rd floor roof level. upon review of information in bis and photos from previous inspection on june 3 2022, it was discovered that construction

    Sep 27, 2022 · Penalty $5,000

    Resolve
  • Class - 1

    Failure to designate and/or have construction superintendnet present at site as required.at time of inspection of active constructino jobsite observed construction activities being done requiring construction s

    Apr 18, 2022

    Resolve
  • Class - 1

    Bc3301.13.12 no const super or competent person present onsite.atoi ofactive jobsite,i observed workers onsite performing const ops.upon request of const super or competent person.workers (illegible) that none

    Dec 13, 2021 · Penalty $2,500

    Resolve
  • Class - 2

    Jobsite fence not constructed or maintained pursuant to subsection-missing viewing panels,grafitti on fence.noted at time of inspection of ademolition site,i observed construction fence in place at exp1.upon fu

    Sep 16, 2021 · Penalty $1,030

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Walk-up apartment building (C7)
Year built
2022
Floors
3
Residential units
9
Building area
11,171 ft²
Lot area
7,500 ft²
Zoning
R4
Community board
208
Council district
11
Block / lot
5766 / 882
Assessed value
$552,600
Landmark / historic district
No

HPD registration #229009, last renewed Aug 29, 2025.

Questions about 3633 Kingsbridge Avenue

Who owns 3633 Kingsbridge Avenue?

The owner of record in NYC Department of City Planning PLUTO data is Egerton LLC.

Does 3633 Kingsbridge Avenue have violations?

NYC HPD has no housing violations on record for this property.

Is 3633 Kingsbridge Avenue rent stabilized?

NYC Department of Finance tax bills listed 9 rent-stabilized units here in 2024 (about 100% of its 9 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 3633 Kingsbridge Avenue built?

City records list 2022 as the year it was built.

How many apartments are in 3633 Kingsbridge Avenue?

It has 9 residential units and 10 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.