roofy

3254 Parkside Place

Bronx, NY 10467BBL 2-03355-0061Map

Owner of record: 3254 Parkside Realty LLC

3254 Parkside Place is an elevator apartment building built in 2020 in Bronx, 10467. It has 98 residential units across 7 floors. The owner of record is 3254 Parkside Realty LLC. HPD has recorded 14 housing violations here, most recently on September 10, 2024. City tax records listed 98 rent-stabilized apartments here in 2024.

HPD violations
14
DOB violations
3
ECB violations
23
HPD complaints
4

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Sep 10, 2024

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
98
About 100% of the building's 98 apartments

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 14

  • A

    Properly repair the source and abate the evidence of a water leak at south wall in the 1st room from north located at apt 1a, 1st story, 1st apartment from east at south

    Sep 10, 2024 · Apt 1A

    Closed — Violation dismissed
  • A

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the kitchenette located at apt 1a, 1st story, 1st apartment from east at south

    Sep 10, 2024 · Apt 1A

    Closed — Violation dismissed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at west wall behind the wall cabinets in the kitchenette located at apt 1a, 1st story, 1st apartment from east at south

    Sep 10, 2024 · Apt 1A

    Closed — Violation dismissed
  • A

    Trace and repair the source and abate the visible mold condition... less than 10 sq ft at ceiling inside the closet in the private hallway located at apt 1a, 1st story, 1st apartment from east at south

    Sep 10, 2024 · Apt 1A

    Closed — Violation dismissed
  • A

    Trace and repair the source and abate the visible mold condition... less than 10 sq ft at ceiling in the bathroom located at apt 1a, 1st story, 1st apartment from east at south

    Sep 10, 2024 · Apt 1A

    Closed — Violation dismissed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at south wall in the bathroom located at apt 1a, 1st story, 1st apartment from east at south

    Sep 10, 2024 · Apt 1A

    Closed — Violation dismissed
  • A

    Properly repair the source and abate the evidence of a water leak at ceiling in the 2nd room from north at east located at apt 1a, 1st story, 1st apartment from east at south

    Sep 10, 2024 · Apt 1A

    Closed — Violation dismissed
  • A

    Properly repair with similar material the broken or defective wood door frame in the 2nd room from north at east located at apt 1a, 1st story, 1st apartment from east at south

    Sep 10, 2024 · Apt 1A

    Closed — Violation dismissed
  • A

    Properly repair the source and abate the evidence of a water leak at south wall in the 1st room from north located at apt 1a, 1st story, 1st apartment from east at south

    Sep 10, 2024 · Apt 1A

    Closed — Violation dismissed
  • A

    Properly repair the source and abate the evidence of a water leak at north wall in the 1st room from north located at apt 1a, 1st story, 1st apartment from east at south

    Sep 10, 2024 · Apt 1A

    Closed — Violation dismissed
Show 4 more ↓
  • A

    Refit cabinet doors at west wall in the kitchenette located at apt 1a, 1st story, 1st apartment from east at south

    Sep 10, 2024 · Apt 1A

    Closed — Violation dismissed
  • A

    Properly repair the source and abate the evidence of a water leak at ceiling in the private hallway located at apt 1a, 1st story, 1st apartment from east at south

    Sep 10, 2024 · Apt 1A

    Closed — Violation dismissed
  • C

    Abate the infestation consisting of roaches in the entire apartment located at apt 1a, 1st story, 1st apartment from east at south

    Sep 10, 2024 · Apt 1A

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 3, 2023

    Closed — Violation dismissed

DOB building violations · 3

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 22, 2021

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Jun 2, 2021

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 9, 2020

    Dob violation - dismissed

ECB violations · 23

  • Class - 1

    I observed the main electrical room with excessive storage, office furniture and equipment being used as a base of operations for the building staff. the electrical room shall be used for electrical distributio

    Sep 5, 2024 · Penalty $1,200

    Resolve
  • Class - 2

    7 story nb active site. i observed jobsite fence not maintained at exp#1,4 at exp#4 fence was not plumb/upright leaning on to active bus lanes. at exp#1 large holes rotten wood sections not painted hunter green

    Oct 25, 2022

    Resolve
  • Class - 2

    A 7 story nb active site.i observed large piles of combustible materials wood garbage sheetrock and other construction materials on roof and setbacks/other locations through out jobsite also causing tripping ha

    Oct 25, 2022

    Resolve
  • Class - 2

    At the time of inspection observed 7sty nb at roof level under construction. observed leaning, broken, missing construction fence ply wood at exp1 creating unsafe construction site.maintain construction fence a

    Sep 2, 2022

    Resolve
  • Class - 2

    Note: at the time of inspection observed 7sty nb at roof level under construction. observed construction dirt on street at exp1 creating inadequate housekeeping condition, could blowout dust through neighborhoo

    Sep 2, 2022

    Resolve
  • Class - 1

    Observed arc welding operation by an aws certified worker at basement level with out fire guards presence, creating fire hazard condition.stop all hot operation, call cse, provide fire guard at the time of hot

    Jun 15, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Note:worker tripped on a egress area have broken dragon board, holes at 7th floor stair landing, twisted his ankle, when he removing garbage by a pull cart. observed inadequate pre shift safety meeting have no

    Jun 15, 2022 · Penalty $10,000

    Resolve
  • Class - 1

    Failure to notify dept of accident/incident that resulted in fatality o injury.note:worker was injured when aframe cart of cement boards tipped forward onto worker.he suffered back injury&was transported to hos

    Aug 11, 2021 · Penalty $1,250

    Resolve
  • Class - 1

    Partial stop work all cement/dragon board operations 5 fl failure to institute safety measures.note:at time of inspection observed a-frame cart on floor along with safety belt attached to plate where christian

    Jul 27, 2021

    Resolve
  • Class - 1

    Bc3301.8.1-use and tampering prohibited note at the time of incident/accident type complaint inspection observed an actiev jobsite as per construction superinetendent worker james martinez fell while relocating

    Sep 2, 2020 · Penalty $2,500

    Resolve
Show 13 more ↓
  • Class - 1

    Bc3301.2-institute and maintain safety measure, note:at the time of incident/accident type complaint inspection observed an actev jobsite as per construction superintendnet worker james martinez fell while relo

    Sep 2, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to notify the dept prior to the commencement of earthwork. noted: at time of my inspection of a new 7 sty bldg,i observed a large foundation wall approx 150ft long & 16ft high upon researching the job

    Mar 23, 2020

    Resolve
  • Class - 2

    Construction fence(job site)not constructed pursuant to subsection. noted: at time of inspection of a 7 sty new bldg. i observed a jobsite construction fence. at return at exp#2 fence at return is not 8 feet

    Mar 23, 2020 · Penalty $500

    Resolve
  • Class - 2

    Bc330916-failure to provide monitoring plan as per code.at time of inspectoin on an active 7 story nb construction site,when request was made for vibration and optical,monitoring pan and report that approve soe

    Feb 5, 2020

    Resolve
  • Class - 1

    Bc33044-failure to provide protection at side of excavation.at time ofinspection on an active 7 story nb construction site notice an open side of excavation that in some places were more than 6' and in other lo

    Feb 5, 2020 · Penalty $5,000

    Resolve
  • Class - 2

    Work not conforming to approve construction documents or amendments-site safety plan.at time of inspection on an active 7 story nb construction site,notice that the site safety plan called for barriers at expos

    Feb 5, 2020

    Resolve
  • Class - 1

    Bc330444-failure to provide guard rail system or solid enclosure at open and accessible side of excavation.at time of inspection on an active 7 story nb construction site,notice an open and accessible side of e

    Feb 5, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to designate and or have construction superintendent present at site as required.note:at the time of inspection observed a inactive jobsite,competent person and a worker was on site.also observed in the

    Oct 16, 2019 · Penalty $625

    Resolve
  • Class - 1

    Failure to notify the department prior to the commencement of earthwork.note:at the time of inspection observed a inactive jobsite,competentperson and a worker was on site.also observed in the dob bis system th

    Oct 16, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Work does not conform to approved plan.note:at the time of inspection observed a inactive job site.competent person and a worker was presenton site.also observed they cut or removed rock at exposure one not as

    Oct 16, 2019 · Penalty $2,500

    Resolve
  • Class - 2

    Construction equipment-fence permit expired.note:at the time of inspection observed a inactive job site.competent person and a worker was present on site.also observed whole site fully fenced with expired permi

    Oct 16, 2019 · Penalty $625

    Resolve
  • Class - 1

    Work without permit.note:at the time of inspection observed a inactivejob site.competent person and worker on site.also observed in the dob bis system they have only earth work permit, no new building permit i

    Oct 16, 2019 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to maintain/display on site documents.note:at time of inspection observed a inactive job site.competent person and a worker was on site.observed they done excavation or cut adjoining rock wall(about 20

    Oct 16, 2019 · Penalty $625

    Resolve

Complaints

  • Water leak

    Heavy flow

    Jun 22, 2025 · Apt 1I

    Close
  • Paint/plaster

    Ceiling

    Jun 22, 2025 · Apt 1I

    Close
  • Water leak

    Heavy flow

    Aug 18, 2024 · Apt 1A

    Close
  • Heat/hot water

    Apartment only

    Dec 23, 2023 · Apt 4A

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D3)
Year built
2020
Floors
7
Residential units
98
Building area
98,158 ft²
Lot area
22,376 ft²
Zoning
R7B
Community board
207
Council district
11
Block / lot
3355 / 61
Assessed value
$6,603,300
Landmark / historic district
No

HPD registration #228598, last renewed Aug 23, 2025.

Questions about 3254 Parkside Place

Who owns 3254 Parkside Place?

The owner of record in NYC Department of City Planning PLUTO data is 3254 Parkside Realty LLC.

Does 3254 Parkside Place have violations?

Yes. NYC HPD has recorded 14 housing violations at this property.

Is 3254 Parkside Place rent stabilized?

NYC Department of Finance tax bills listed 98 rent-stabilized units here in 2024 (about 100% of its 98 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 3254 Parkside Place built?

City records list 2020 as the year it was built.

How many apartments are in 3254 Parkside Place?

It has 98 residential units and 99 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.