roofy

3056 Decatur Avenue

Bronx, NY 10467BBL 2-03331-0019Map

Owner of record: Z & M 3056 LLC

3056 Decatur Avenue is a walk-up apartment building built in 2022 in Bronx, 10467. It has 9 residential units across 4 floors. The owner of record is Z & M 3056 LLC. HPD has recorded 1 housing violation here, most recently on June 16, 2025. City tax records listed 9 rent-stabilized apartments here in 2024.

HPD violations
1
DOB violations
2
ECB violations
30
HPD complaints
2

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Jun 16, 2025

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
9
About 100% of the building's 9 apartments

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 1

  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Jun 16, 2025

    Closed — Violation dismissed

DOB building violations · 2

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 20, 2021

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 2, 2020

    Dob violation - dismissed

ECB violations · 30

  • Class - 1

    At time of inspection o a 4 story nb active site. i observed at 3 fl exp4 cmu wall in place covering adjoining property window with out any protection of window. as per bc 3309.14 this condition causes an immed

    Aug 24, 2022

    Resolve
  • Class - 2

    At time of inspection of a 4 story nb active site. i observed a sidewalk shed in place with construction fence underneath at exp#1. upon further inspection it was observed the gap was 5 ft and was missing prote

    Aug 24, 2022

    Resolve
  • Class - 2

    At time of inspection of a 4 story nb active site. i observed a sidewalk shed in place approximately 16 ft in height at exp#1. upon request for required logs for daily inspection of temporary construction equip

    Aug 24, 2022

    Resolve
  • Class - 1

    At time of inspection of a 4 story nb active site. i observed inadequate housekeeping onsite at multiple locations/entire site. worker's subjected to multiple tripping hazards. masonry blocks/wooden skids/debri

    Aug 24, 2022 · Penalty $625

    Resolve
  • Class - 1

    Inspection of a 4 story nb active site. i observed no missing/inadequate guardrails onsite at multiple locations 2 & 3 floors at exp#1,4. also missing guardrails/protection at stairwells on 2 & 3rd floor. worke

    Aug 24, 2022 · Penalty $5,000

    Resolve
  • Class - 2

    At time of inspection of a 4 story nb active site. i observed sections of construction fence missing at rear of building at exp 4. also at exp1 door was not painted hunter green as per code. public can enter jo

    Aug 24, 2022

    Resolve
  • Class - 2

    4 story nb active site. i observed multiple hazardous conditions onsite.1) masonry wall in place at 3 fl exp4 covering unprotected window of adjoining property.2) observed missing guardrails 2,3 fl exp1,3/ also

    Aug 24, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Work without permit at time of inspection,observed construction operations in progress installation of structural cold form steel.upon further review in the building information system(bis)and in dob now,job ap

    Jun 3, 2022 · Penalty $625

    Resolve
  • Class - 1

    Bc 1704.1 special inspections at time of inspection observed construction operations in progress installation of cold form steel joist.upon further review in the building information system and dob new,no speci

    Jun 3, 2022 · Penalty $625

    Resolve
  • Class - 2

    Bc3301.2 no rebar caps.at time of inspection observed active job sit of proposed 4 story nb at foundation stage concrete work in progress noted contractor pouring concrete for footing & bar were pointing up cre

    Mar 15, 2022 · Penalty $625

    Resolve
Show 20 more ↓
  • Class - 2

    Construction superintendent failed to perform duties per code.at time of inspection noted construction superintendent failed to perform duties per code no guard rails inadequate housekeeping no concrete washout

    Mar 15, 2022 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to maintain adequate housekeeping per section requirements.at time of inspection observed active jobsite of proposed 4 story nb at foundation stage noted main egress to rear side obstructed by construct

    Mar 15, 2022 · Penalty $625

    Resolve
  • Class - 2

    No concrete wash out.at time of inspection observed active jobsite of proposed 4 story nb at foundation stage concrete work in progress noted contractor pouring concrete for footing no concrete washout as requi

    Mar 15, 2022 · Penalty $625

    Resolve
  • Class - 1

    No guard rails.at time of inspection observed active job site of proposed 4 story nb at foundation stage noted no guard rails at exp #1 #2 of bldg foundation as required by code.contractor pouring footing aprox

    Mar 11, 2022

    Resolve
  • Class - 2

    No orientation logs.at time of inspection observed active job site 4 story nb at excavation stage requested orientation logs were not on site as required by code.remedy:maintain orientation logs on site.

    Nov 17, 2021 · Penalty $655

    Resolve
  • Class - 2

    No pre-construction survey.at time of inspection observed active job sit 4 story nb at foundation stage requested pre-construction survey not on site as required by code.remedy:provide pre-construction survey

    Nov 17, 2021

    Resolve
  • Class - 1

    Bc1803.1 failure to provide weather proofing.at time of inspection observed active job site 4 story nb at excavation stage.observed exposed existing foundation wall at exp #2 and #4 w/o weather proofing as requ

    Nov 17, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    Inadequate protection at sides of excavation.at time of inspection observed active jobsite 4 story nb at excavation stage.observed support of excavation at exp #2 not fully lagged as required.remedy:provide tim

    Nov 17, 2021 · Penalty $5,000

    Resolve
  • Class - 1

    Work does not conform to approved construction documents.at time of inspection observed at active jobsite 4 story nb at excavation stage shear cut of aprox 12 feet deep not conforming to approve plans requiring

    Nov 17, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    Bc3304.7 inadequate egress.at time of inspection observed active job site of 4 story nb at excavation stage.contractor using ramp as egress w/o guard rails as required it is block by excavator.remedy:provide ad

    Nov 17, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    Construction superintendent failed to perform duties as per code.at time of inspection observed active job site 4 story nb at excavation stage construction superintendent or logs were not not site plus work con

    Nov 17, 2021 · Penalty $10,000

    Resolve
  • Class - 2

    No site safety plans at job site.at time of inspectoin observed active job site 4 story nb at foundation stage request for site safety not on site as required by code.remedy:provide site safety plans.request cs

    Nov 17, 2021

    Resolve
  • Class - 2

    No monitoring.at time of inspection observed active job site 4 story nb at excavation stage requested monitoring reports not on site are required by code.remedy:provide monitoring reports.

    Nov 17, 2021

    Resolve
  • Class - 2

    Fence not constructed/maintained pursuant to subsection. at the time of my inspection,i observed that the construction fence at exposure#1:(1)warping plywood panels;(2)a broken,protruding 2x4;and (3)improperly

    Oct 1, 2021

    Resolve
  • Class - 2

    Temp const equipment onsite (fence)-expired permit.note:atoi observed fully fenced vacant land.observed they built temp const equipment fence using plywood,wood@exp1,2,3,4;&fence have [email protected] observed

    Jun 25, 2021 · Penalty $1,250

    Resolve
  • Class - 2

    Failure to safeguard all persons & property. at time time of my inspection of a full demolition active jobsite. i observed no pedestrians protection while dump truck was parked blocking the sidewalk being loade

    Oct 28, 2020 · Penalty $5,000

    Resolve
  • Class - 1

    Demolition. at time of my inspection,i observed 100 percent demolitioncompleted. upon doing my research i noticed no notication of the dept as per sec 3306.3.1 ddept & adjoining bldg owners prior to commencemen

    Oct 28, 2020 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to comply w/ the commissioner's order contained in summons/vio#39019540y issued on 3/12/2020 and to file a certificate of correctionpursuant to 28-201.1 and 1rcny 102-01. failure to maintain building wa

    Oct 2, 2020 · Penalty $1,250

    Resolve
  • Class - 2

    Temporary construction equipment on site fence permit expired. at the time of my inspection active job site demo-monitoring i observed fencepermit expired on 8/18/2020. renew fence permit-issued. remedy:comply

    Sep 4, 2020 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to maintain building. defect is: rotted wood roof with large section missing, leaving building open to the elements. rotted wood siding at all four exposures., maintain exterior building wall; immediate

    Mar 12, 2020 · Penalty $6,250

    Resolve

Complaints

  • Heat/hot water

    Apartment only

    Jul 28, 2023 · Apt 2C

    Close
  • Heat/hot water

    Entire building

    Sep 8, 2019 · Apt 1E

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Walk-up apartment building (C1)
Year built
2022
Floors
4
Residential units
9
Building area
5,812 ft²
Lot area
3,000 ft²
Zoning
R6B
Community board
207
Council district
11
Block / lot
3331 / 19
Assessed value
$619,650
Landmark / historic district
No

HPD registration #229102, last renewed Aug 27, 2025.

Questions about 3056 Decatur Avenue

Who owns 3056 Decatur Avenue?

The owner of record in NYC Department of City Planning PLUTO data is Z & M 3056 LLC.

Does 3056 Decatur Avenue have violations?

Yes. NYC HPD has recorded 1 housing violations at this property.

Is 3056 Decatur Avenue rent stabilized?

NYC Department of Finance tax bills listed 9 rent-stabilized units here in 2024 (about 100% of its 9 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 3056 Decatur Avenue built?

City records list 2022 as the year it was built.

How many apartments are in 3056 Decatur Avenue?

It has 9 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.