2703 Webster Avenue
Bronx, NY 10458BBL 2-03278-0014Map
Owner of record: NYC Department Of Education
2703 Webster Avenue is a school building built in 1998 in Bronx, 10458. The owner of record is NYC Department Of Education. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 34
- ECB violations
- 48
- HPD complaints
- 3
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 34
- Low pressure boiler boiler required
Violation issued-failure to file 2024 external low pressure inspection
Nov 14, 2025
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2024 external low pressure inspection
Nov 14, 2025
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2024 external low pressure inspection
Nov 14, 2025
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 3, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 10, 2020
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 29, 2018
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 6, 2017
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2015 inspection/test
Dec 1, 2016
Dob violation - dismissed
Show 24 more ↓
- Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 1, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 3, 2015
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 13, 2014
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 2, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 9, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 10, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 20, 2008
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 21, 2006
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 6, 2005
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 1, 2004
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 19, 2003
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 19, 2003
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 19, 2003
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 26, 2002
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 26, 2002
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 26, 2002
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Feb 19, 2002
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Mar 10, 2000
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 7, 2000
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 7, 2000
Dob violation - dismissed
ECB violations · 48
- Class - 2
Reissue#35721010l failure to maintain building in code-compliant manner.noted:at exit 3 cafeteria water penetrations have caused water damage to the walls in several areas.rem:repair and/or replace.
Jun 18, 2026 · Penalty $3,125
Active - Class - 2
Reissue#35721008m failure to maintain building wall(s)or appurtenancesnoted:on roof there is several areas that have flashing in disrepair or missing all together.rem:maintain exterior wall.
Jun 18, 2026 · Penalty $6,250
Active - Class - 2
Reissue#35721007k exit door not self-closing.noted:on 1st flr-exteriorexit 4 does not self-close properly when tested.rem:repair/replace door.
Jun 18, 2026 · Penalty $1,562
Active - Class - 2
Reissue #35692294m. failure to maintain building wall(s) and appurtenances. noted: missing brick over exit 1. roof parapet misplace/loose flashing. remedy: maintain exterior wall.
Jul 24, 2025 · Penalty $6,250
Active - Class - 2
Failure to maintain building in code-compliant manner. noted: water penetration on interior walls in cafeteria at exit 3 on first floor. remedy: repair and/or replace.
Jul 24, 2025 · Penalty $1,250
Active - Class - 2
Reissue #35692295y. exit door not self-closing. noted: observed at 1stflr corridor by 111, m111, corridor by 112m corridor by 106, auditorium stage right doors are not closing correctly. 3rd flr, staircase(b) e
Jul 24, 2025 · Penalty $1,562
Active - Class - 2
Failure to maintain building in code-compliant manner. noted: classroom doors do not self-close and have to be forced to close in current locations. 4th flr(3-412), (402). 3rd flr(304). remedy: repair and/or re
Jul 24, 2025 · Penalty $1,250
Resolve - Class - 2
Failure to maintain building in code-compliant manner. no fire stopping per bc 712.3; 27-345. noted: there is no fire stopping in electricalroom at all. remedy: provide/maintain fire stopping.
Jul 24, 2025 · Penalty $1,250
Resolve - Class - 2
Reissue #35676238h. failure to maintain, building wall(s) and appurtenances. noted: observed at 195 street retaining wall columns with cracks and missing mortar running vertical and horizontal at bricks, at mai
Oct 8, 2024 · Penalty $3,125
Resolve - Class - 2
Failure to maintain building in code-complaint manner. noted: observedat 1 floor corridor by 111, m 111, corridor by 112, corridor by 106, auditorium stage right doorsare not closing correctly. remedy: repair a
Oct 8, 2024 · Penalty $625
Resolve
Show 38 more ↓
- Class - 2
Failure to maintain building in code-compliant manner. noted: retaining wall around the play area at webster ave and 195th st. side with missing mortar and brick columns with vertical cracks at various areas. r
Jul 20, 2023 · Penalty $1,250
Resolve - Class - 2
Reissue35561378j failure to maintain bldg in codecompliant manner noted:water damage to walls behind kitchen due to leak in wall repair &or replace
May 25, 2022 · Penalty $1,562
Resolve - Class - 2
Reissue35561379l failure to maintain bldg wall(s) or appurtenances.noted:@rear of bldg (exp3) water penetrates thru wall causing damage to interior walls maintain bldg exterior wall
May 25, 2022 · Penalty $3,125
Resolve - Class - 2
Automat feed water modulating valve defective, corroded and leaking, blrs 01, 02, and 03-smoke alarms defective and exposed electrical blrs, 01, 02 and 03-no guards at water level glasses-fuel oil stored in boi
Mar 21, 2022 · Penalty $625
Active - Class - 2
Reissue#35498376r failure to maintain in code compliant manner. note: water damage to walls behind kitchen due to leaks in walls. remedy: repair &/or replace.
Jul 22, 2021 · Penalty $1,562
Resolve - Class - 2
Failure to maintain bldg walls & appurtenance. note: at exp#3 rear of bldg water penetrates through walls causing damage to interior walls. remedy: maintain bldg exterior walls.
Jul 22, 2021 · Penalty $1,250
Resolve - Class - 2
Failure to maintain building wall(s) or appurtenances noet observed at gym yard across from exits 7&8 that water penetrates the pavement which is causing water damage to the rear hall of the cafeteria which is
Jun 3, 2020 · Penalty $1,250
Resolve - Class - 2
Failure to maintain building in code compliant manner note observed in ear hallway behind the kitchen and cafeteria water penetration from gym yard above are leaking water damage on walls and ceiling causing
Jun 3, 2020 · Penalty $625
Resolve - Class - 2
Reissue 35270942l exit door not self closing: note at auditorium right side of stage exit door not closing. rmdy: repair and/or replace door.
May 9, 2018
Resolve - Class - 2
Reissue #35216824n exit doors not self closing. at following locations: auditorium right of stage. exit 3 door. rmdy: repair/replace.
Jun 13, 2017
Resolve - Class - 2
Failure to maintain bldg in code compliant manner. noted: water penetrartion at vestibule ceiling in the exit(3)from cafeteria was observed. remedy: repair &/or replace.
Oct 28, 2016
Resolve - Class - 2
Exit door not self closing. noted: at 1st fl auditorium entrance,at right exit from stage,at kitchen exit,at exit(3)from cafeteria,at lobby door leading to cafeteria,doors do not close property. remedy: repair
Oct 28, 2016
Resolve - Class - 2
Failure to maintain building wall(s) or appurtenances. noted: water penetrating building envelope at cafeteria exit 3 1st story damage ceiling and walls of exit vestiblue and cafeteria ceiling. comply with noti
Mar 2, 2016
Resolve - Class - 2
Failure to maintain bldg in code compliant manner.@ 6pm lighting not working properly.dark.inoperable.rem comply w/ notice of vio
May 19, 2015
Resolve - Class - 2
Exit doors not self closing.@ 2b,4b,adjacent to room 205,wood exit doors are cracked & delaminating along hinge plate.rem:replace doors.
Jul 21, 2014
Resolve - Class - 2
The following doors not self closing: 1st fl:1-cafeteria exit double-door; 2-exit door #3;2nd flr:10staira,2-stairb,4th flr:1-stairb exit 2 5th flr: stairb exit.rmdy: repair/replace door.
Jul 24, 2013
Resolve - Class - 2
Broken door @ 2nd flr stwy a door is broken and delimaminated cannot hold door check,for fire proof self closing.rem:replace door
May 27, 2011
Resolve - Class - 2
Partial fire corridor obstruction @ corridor behind auditorium,with numerous boxes,stacks of tables,rolling carts and various classroom items.rem:remove all items,maintain corridor width clear
May 27, 2011
Resolve - Class - 2
14m07,52m07,60q03,77q03,81m07.(52m07)provide spin out for hoist cables.(77q03)install guard for light under car.
Feb 2, 2011
Resolve - Class - 2
Failure to post occupancy sign in the 1st flr auditorium at the time of inspection. remedy: provide/maintain occupancy sign at the auditorium.
May 28, 2010
Resolve - Non-hazardous
27-127 reissue:34592914j roof above cafeteria has become (porous) and allowing rain to enter the building causing interior damages below in cafeteria on the st floor level rem: water proof exterior roof
Apr 29, 2008
Resolve - Non-hazardous
27-127 reissue: 34592915l corridor block wall has a vertical crack approximately 7 ft long adjacent to proof #6 on basement lvl rem: repair block wall
Apr 29, 2008
Resolve - Non-hazardous
27-127 failure to provide fresh air in the gas meter room n basement level rem: provide fresh air to gas meter room
Apr 29, 2008
Resolve - Hazardous
Roof above the auditorium stage has become porous & allowing rain water into the bldg below on the 1st fl level causing interior damages.remedy:water proof roof
Apr 29, 2008
Resolve - Non-hazardous
Reissue #34519048l water penetration through vestibule ceiling (below exterior concrete stairs) & into cafeteria located @ 1st fl southwest section. remedy: stop water penetration & make all necessary repairs.
Aug 29, 2007
Resolve - Non-hazardous
Reissue #34519049n corridor block wall has a vertical stress crack approx. 8ft long located adjacent to room #6 on basement level. remedy: repair block wall.
Aug 29, 2007
Resolve - Non-hazardous
Brick facade @ south side above exterior exit has a vertical stress crack approx. 4ft. remedy: repair masonary
Aug 29, 2007
Resolve - Hazardous
Reissue 34466830p exterior concrete steps has become porous & allowingrain water to enter the bldg & causing damage to the interior finish located southwest vestibule on the 1st flr adjacent to the exit door
Apr 19, 2006
Resolve - Hazardous
Reissue 34466833k corridor concrete wall has a vertical crack appro 6 feet located adjacent to room 6 @ basement level.remedy:repair wall
Apr 19, 2006
Resolve - Hazardous
"re-issue" 34424148r. failure to maintain building. defect noted: 1st floor cafeteria, south west vestibule has waer penetration causing ceiling tile to sag & possibly collapse. used as an exit to play yard.
Feb 11, 2005
Resolve - Non-hazardous
Failure to maintain building. defect noted: fifth floor, stair a door at corridor is missing. remedy: maintain building. install door.
Feb 11, 2005
Resolve - Non-hazardous
Failure to maintain building. defect noted: 1st floor auditorium room 102, north side two exit doors not closing, hitting each other before closing. remedy: maintain building. replace doors.
Feb 11, 2005
Resolve - Non-hazardous
Failure to maintain building. defect noted: basement corridor block wall near room 06 has a vertical crack approx. 3ft long. remedy: maintain wall. make all necessary repairs.
Feb 11, 2005
Resolve - Hazardous
Failure to maintain defect noted continuos water penetration causing 1x 1 ceiling tile sag w/possible collapse onto children at entrance wayof cafetria location cafeteri sw entrance interior .remedy:make all
Jan 8, 2004
Resolve - Non-hazardous
Failure to maintain : defect are : roof leaking causing ceiling & wood floor damage to 2 areas location : (1) gymnasium (2) cafeteris remedy : make all necessary repairs maintain build
Jan 16, 2003
Resolve - Non-hazardous
Failure to maintain defect is roof leaks at gymnasium,water penetration on to hardwood floor.rem:repair roof.
Mar 12, 2001
Resolve - Hazardous
Failur eto provide protection at sides of excavation having excavated a depth of approx 10ft without providing any sheeting and showing with protection fence for adject md egress approx 100 long stop all work
Feb 4, 1997 · Penalty $750
Resolve - Non-hazardous
Work without a permit noted having escavated a depth approx 12x175 long by 50 wide stop all work remedy otbain approvals and permit or restore premises to prior legla condition
Feb 4, 1997
Resolve
Complaints
- Heat/hot water
Entire building
May 5, 2017 · Apt 206
Close - Heating
Heat related
May 22, 2006 · Apt 5G
Close - Heating
Heat related
Oct 25, 2005 · Apt 5G
Close
Sales history
No recorded sales in our data
Building details
- Building type
- School building (W1)
- Year built
- 1998
- Floors
- 5
- Residential units
- —
- Building area
- 98,000 ft²
- Lot area
- 40,000 ft²
- Zoning
- R7D
- Community board
- 207
- Council district
- 15
- Block / lot
- 3278 / 14
- Assessed value
- $16,785,450
- Landmark / historic district
- No
Questions about 2703 Webster Avenue
Who owns 2703 Webster Avenue?
The owner of record in NYC Department of City Planning PLUTO data is NYC Department Of Education.
Does 2703 Webster Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 2703 Webster Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 2703 Webster Avenue built?
City records list 1998 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.