roofy

2017 Morris Avenue

Bronx, NY 10453BBL 2-02829-0062Map

Owner of record: 2017 Morris Avenue Housing Development F Und Co INC

2017 Morris Avenue is an elevator apartment building built in 2008 in Bronx, 10453. It has 39 residential units across 9 floors. The owner of record is 2017 Morris Avenue Housing Development F Und Co INC. HPD has recorded 109 housing violations here, most recently on October 7, 2026. 28 of the 50 most recent violations are still open. City tax records listed 39 rent-stabilized apartments here in 2024.

HPD violations
109
DOB violations
18
ECB violations
24
HPD complaints
293

What to know

Concern
10 open Class C

Immediately hazardous issues among recent violations are still open.

Watch
Last violation Oct 7, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
39
About 100% of the building's 39 apartments

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 109

  • C

    Abate the infestation consisting of roaches in the entire apartment located at apt 6a, 6th story, 1st apartment from north at east , section at north

    Oct 7, 2026 · Apt 6A

    Open — Notice of issuance sent to tenant
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at east wall in the 3rd room from north located at apt 6a, 6th story, 1st apartment from north at east , section at north

    Oct 7, 2026 · Apt 6A

    Open — Nov sent out
  • B

    Properly repair the source and abate the evidence of a water leak at east wall in the 3rd room from north located at apt 6a, 6th story, 1st apartment from north at east , section at north

    Oct 7, 2026 · Apt 6A

    Open — Nov sent out
  • B

    Properly repair the source and abate the evidence of a water leak at ceiling in the bathroom located at apt 6a, 6th story, 1st apartment from north at east , section at north

    Oct 7, 2026 · Apt 6A

    Open — Nov sent out
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the bathroom located at apt 6a, 6th story, 1st apartment from north at east , section at north

    Oct 7, 2026 · Apt 6A

    Open — Nov sent out
  • B

    Properly repair with similar material the broken or defective porcelain enamel finish by method of reglazing at bathtub in the bathroom located at apt 6a, 6th story, 1st apartment from north at east , section at north

    Oct 7, 2026 · Apt 6A

    Open — Nov sent out
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the private hallway located at apt 6a, 6th story, 1st apartment from north at east , section at north

    Oct 7, 2026 · Apt 6A

    Open — Nov sent out
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at 1st window casing from north at east in the 3rd room from north located at apt 6a, 6th story, 1st apartment from north at east , section at north

    Oct 7, 2026 · Apt 6A

    Open — Nov sent out
  • B

    Properly repair the source and abate the evidence of a water leak at ceiling in the private hallway located at apt 6a, 6th story, 1st apartment from north at east , section at north

    Oct 7, 2026 · Apt 6A

    Open — Nov sent out
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 6a, 6th story, 1st apartment from north at east , section at north

    Oct 7, 2026 · Apt 6A

    Open — Notice of issuance sent to tenant
Show 40 more ↓
  • B

    Properly repair the source and abate the evidence of a water leak at 1st window casing from north at east in the 3rd room from north located at apt 6a, 6th story, 1st apartment from north at east , section at north

    Oct 7, 2026 · Apt 6A

    Open — Nov sent out
  • A

    Post and maintain a proper sign on wall of entrance story showing the registration number assigned by the department and the address of the building. at public hall, 1st story

    Sep 3, 2026

    Open — Nov sent out
  • A

    Post a proper notice of smoke detector requirements, in a form approved by the commissioner, at or near the mailbox signage missing at public hall, 1st story

    Sep 3, 2026

    Open — Nov sent out
  • A

    Post a proper notice of carbon monoxide detecting device requirements, in a form approved by commissioner, in a common area of a class a multiple dwelling near inspection certificate or provide notice to tenants in private dwellings signage missing

    Sep 3, 2026

    Open — Nov sent out
  • C

    Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system signage missing at public hall, 1st story

    Sep 3, 2026

    Open — Nov sent out
  • A

    Paint with light colored paint to the satisfaction of this department at ceiling at public hall, 8th story

    Aug 12, 2026

    Open — Nov sent out
  • A

    Properly repair with similar material the broken or defective fire retardent material at ceiling at public hall, 8th story

    Aug 12, 2026

    Open — Nov sent out
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color north wall in the 1st room from north located at apt 9d, 9th story, 2nd apartment from north at east

    Mar 11, 2026 · Apt 9D

    Closed — Violation dismissed
  • A

    Trace and repair the source and abate the visible mold condition... at north wall approximately 4 squate feet in the 1st room from north located at apt 9d, 9th story, 2nd apartment from north at east

    Mar 11, 2026 · Apt 9D

    Closed — Violation closed
  • B

    Trace and repair the source and abate the visible mold condition... at north wall approximately 4 squate feet in the 1st room from north located at apt 9d, 9th story, 2nd apartment from north at east original violation 18716360 issued 11-mar-26 has been upgraded to class b per administrative code 27-2017.3a(3)(a) or (b).

    Mar 11, 2026 · Apt 9D

    Open — Notice of issuance sent to tenant
  • A

    Repair the broken or defective plastered surfaces and paint in a uniform color ceiling and all walls in the 3rd room from north at east located at apt 9d, 9th story, 2nd apartment from north at east

    Mar 11, 2026 · Apt 9D

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective ceramic tiles at south wall in the bathroom located at apt 6b, 6th story, 2nd apartment from south at west

    Oct 28, 2025 · Apt 6B

    Closed — Violation dismissed
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 6b, 6th story, 2nd apartment from south at west

    Oct 28, 2025 · Apt 6B

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective ceramic wall tiles at south wall in the bathroom located at apt 6b, 6th story, 2nd apartment from south at west

    Oct 25, 2025 · Apt 6B

    Closed — Violation dismissed
  • C

    Abate the infestation consisting of roaches in the entire apartment located at apt 6b, 6th story, 2nd apartment from south at west

    Oct 25, 2025 · Apt 6B

    Closed — Violation dismissed
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 6b, 6th story, 2nd apartment from south at west

    Oct 25, 2025 · Apt 6B

    Closed — Violation dismissed
  • B

    Properly repair or replace the broken or defective electrical outlet at south wall in the kitchen located at apt 6b, 6th story, 2nd apartment from south at west

    Oct 25, 2025 · Apt 6B

    Closed — Violation dismissed
  • B

    Repair, replace or provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations deffective in the entire apartment located at apt 8d, 8th story, 2nd apartment from north at east

    Sep 10, 2025 · Apt 8D

    Closed — Violation closed
  • B

    Repair, replace or provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules deffective in the entire apartment located at apt 8d, 8th story, 2nd apartment from north at east

    Sep 10, 2025 · Apt 8D

    Closed — Violation closed
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 8d, 8th story, 2nd apartment from north at east

    Sep 10, 2025 · Apt 8D

    Open — Not complied with
  • C

    Replace or repair the self-closing doors that is missing or defective hinge at hopper door at south wall at public hall, 8th story

    Aug 17, 2025

    Open — Not complied with
  • C

    Replace or repair the self-closing doors that is missing or defective hinges at hopper door at trash chute at south wall at public hall, 1st story

    Aug 3, 2025

    Closed — Violation closed
  • C

    Replace or repair the self-closing doors that is missing or defective hinges at hopper door at trash chute at south wall at public hall, 6th story

    Aug 3, 2025

    Closed — Violation closed
  • C

    Replace or repair the self-closing doors that is missing or defective latchset at door leading to stair b at public hall, 6th story

    Aug 3, 2025

    Closed — Violation closed
  • C

    Abate the infestation consisting of roaches in the entire apartment located at apt 8a, 8th story, 1st apartment from north at east

    Aug 2, 2025 · Apt 8A

    Closed — Violation closed
  • B

    Trace and repair the source and abate the visible mold condition... less than 10 sq ft at ceiling in the bathroom located at apt 5c, 5th story, 1st apartment from south at west original violation 18103669 issued 21-jul-25 has been upgraded to class b per administrative code 27-2017.3a(3)(a) or (b).

    Jul 21, 2025 · Apt 5C

    Open — Notice of issuance sent to tenant
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 5c, 5th story, 1st apartment from south at west

    Jul 21, 2025 · Apt 5C

    Open — Notice of issuance sent to tenant
  • A

    Trace and repair the source and abate the visible mold condition... less than 10 sq ft at ceiling in the bathroom located at apt 5c, 5th story, 1st apartment from south at west

    Jul 21, 2025 · Apt 5C

    Closed — Violation closed
  • C

    Replace or repair the self-closing doors that is missing or defective hinges at stair b - door at public hall, 10th story

    Nov 24, 2024

    Closed — Violation closed
  • C

    M/d law abate the nuisance consisting of hot water exceeding the limit of 130 degrees at faucets in the entire apartment located at apt 10d, 10th story, 2nd apartment from north at east

    Nov 24, 2024 · Apt 10D

    Closed — Violation closed
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 10d, 10th story, 2nd apartment from north at east

    Nov 24, 2024 · Apt 10D

    Open — Defect letter issued
  • C

    Abate the infestation consisting of roaches in the entire apartment located at apt 10d, 10th story, 2nd apartment from north at east

    Nov 24, 2024 · Apt 10D

    Open — Defect letter issued
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the 2nd room from east located at apt 9a, 9th story, 1st apartment from north at east

    Apr 15, 2024 · Apt 9A

    Open — Not complied with
  • B

    Properly repair the source and abate the evidence of a water leak at ceiling in the 2nd room from east located at apt 9a, 9th story, 1st apartment from north at east

    Apr 15, 2024 · Apt 9A

    Open — Not complied with
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the bathroom located at apt 9a, 9th story, 1st apartment from north at east

    Apr 15, 2024 · Apt 9A

    Closed — Violation closed
  • C

    Abate the infestation consisting of roaches in the entire apartment located at apt 9a, 9th story, 1st apartment from north at east

    Jan 25, 2024 · Apt 9A

    Open — False certification
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 9a, 9th story, 1st apartment from north at east

    Jan 25, 2024 · Apt 9A

    Open — False certification
  • B

    Repair or replace the smoke detector defective in the entire apartment located at apt 9a, 9th story, 1st apartment from north at east

    Jan 25, 2024 · Apt 9A

    Closed — Violation dismissed
  • B

    Repair or replace the carbon monoxide detecting device(s). defective in the entire apartment located at apt 9a, 9th story, 1st apartment from north at east

    Jan 25, 2024 · Apt 9A

    Closed — Violation dismissed
  • C

    Replace or repair the self-closing doors that is missing or defective hinges in the entrance located at apt 6d, 6th story, 2nd apartment from north at east

    Nov 29, 2023 · Apt 6D

    Closed — Violation dismissed

DOB building violations · 18

  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 27, 2019

    Dob violation - resolved
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 19, 2018

    Dob violation - dismissed
  • No report and / or late filing (facade) facade required

    Failed to file fisp cycle 8a technical report by 02/21/2017

    May 31, 2018

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    May 30, 2018

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 13, 2017

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 12, 2016

    Dob violation - resolved
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2013 inspection report

    Mar 3, 2015

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2013 inspection report

    Mar 3, 2015

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2013 inspection report

    Mar 3, 2015

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst

    May 30, 2014

    Dob violation - dismissed
Show 8 more ↓
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 9, 2013

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 9, 2013

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 2, 2012

    Dob violation - resolved
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2010 inspection/test

    Dec 13, 2011

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Mar 3, 2011

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 16, 2010

    Dob violation - resolved
  • Emergency none

    Egncy-emergency none

    Nov 18, 1997

    Dob violation - dismissed
  • Unsafe buildings none

    Ub-unsafe buildings none

    Jun 12, 1997

    Dob violation - dismissed

ECB violations · 24

  • Class - 1

    Door restrictor not working properly, repair, phone not working, repair

    Jan 11, 2024 · Penalty $1,250

    Resolve
  • Class - 3

    Failure to post bldg exterior wall condition certification as requiredunder 1rcny 103-04. note: at time of inspection it is observed that exterior wall condition certificate was not posted. remedy: post bldg ex

    Aug 26, 2020

    Resolve
  • Class - 1

    Cu05a10 upon inspection of elevator the car zone restrictor was tampered with rendered it inoperative. rmdy: repair and contact nycdob for return to service.

    Jun 22, 2018 · Penalty $1,250

    Resolve
  • Class - 2

    Failure to submit acceptable 8th round report of critical examination documenting condition of exterior walls and appurtenances required by 28-302.4 for control#814724. remedy: submit required technical report

    May 18, 2018 · Penalty $625

    Resolve
  • Class - 1

    Cu-05a10; 70o02. 05a10- only elevator in bldg. car door zone restrictor altered. rendered it disabled and inoperatie. rmdy: repair and contact nycdob to restore to service. upon a reinspection of device.

    Mar 4, 2018 · Penalty $1,000

    Resolve
  • Class - 2

    18d06,32e10,61t07,68b07,70o02,71l10. 18-basement kicker spring unsecured; 32-counterweight guide shoes rubbing/making noise; 61-company label on mainline missing; 68b-provide detailed entries in maint log.

    Dec 29, 2015

    Resolve
  • Class - 2

    67x10; 67-repair emergency phone in elev. car.

    May 19, 2015 · Penalty $500

    Resolve
  • Class - 2

    52d06. 52d06 hoist pables jumped off the traction sheave make all neccessary repairs. call dob for a full inspection 212 566-5544

    Jul 13, 2009

    Resolve
  • Class - 1

    Site safety manager/coordinator not on site noted: apprx 60 workers interior and exterior work no site safety manager at site. remedy: stop all work provide site safety manager.

    Jun 24, 2009 · Penalty $2,400

    Resolve
  • Class - 2

    Section 3314.3.2. when plans are required by this section they shall include a plan view, an elevation view details of anchorage, scaffold designation in accordance with section 3314.3.3. & for supported scaffo

    Apr 9, 2009

    Resolve
Show 14 more ↓
  • Class - 2

    Failure to provide approved/accepted plans at job site at time of inspno plans for supported scaffold. remedy: provide plans.

    Mar 27, 2009

    Resolve
  • Class - 2

    Failure to maintain adequate housekeeping per section requirements. soil/rock covering footing for pipe scaffold. remedy: maintain adequate housekeeping.

    Mar 27, 2009 · Penalty $400

    Resolve
  • Class - 2

    Licensed rigger failed to ensure scaffold worker met minimum req. no cert of fitness. remedy: comply with code.

    Mar 27, 2009 · Penalty $400

    Resolve
  • Class - 1

    Inadequate safety measures operation of hoisting equipment in unsafe manner. lifelines all tied back to same cable. remedy: discontinue use

    Mar 27, 2009 · Penalty $4,800

    Resolve
  • Class - 1

    Sec 3307.8 guardrail requirement noted at top of staircase roof lvl noguardrail provided guardrail missing at whole perimeter of roof none guardrail missing at scaffolding at front of bldg and top of roof rem:

    Mar 17, 2009 · Penalty $400

    Resolve
  • Class - 1

    Toe board requirement noted no toe board provide at whole perimeter area of roof no toe boards at roof lvl staircase none of the toe boards at elevator shaft is 5 1/2" toe boards missing on scaffolding erected

    Mar 17, 2009 · Penalty $400

    Resolve
  • Class - 1

    Sec 3301.7 design requirement noted no design drawing provided to showhigh bridge for sidewalk shed at front of bldg rem: provide design drawing

    Mar 17, 2009 · Penalty $400

    Resolve
  • Class - 1

    Site safety manager coordinator not on site noted site safety manage has not been on site since 3/31/09 rem: stop all work provide safety manager coordinator call best squad for reinsp

    Mar 17, 2009 · Penalty $1,200

    Resolve
  • Class - 1

    Site safety plan and site safety program required no site safety plans provided bldg at roof lvl 10fl no horizontal netting in place rem: stop all work provide site safety plan & program call best squad for rei

    Mar 17, 2009 · Penalty $400

    Resolve
  • Class - 1

    Failure to safeguard all persons and property affected by constructionoperations noted at front of bldg 6 section of supported scaffolding has been erected no overhead protection has been provided for workers g

    Mar 17, 2009 · Penalty $1,200

    Resolve
  • Class - 1

    Failure to safeguard all persons and property affected by constructionoperations noted at roof level no guardrails vertical netting toe boards caution tape ropes provides for temporary protection of workers app

    Mar 17, 2009 · Penalty $2,400

    Resolve
  • Class - 1

    Sec 3314.3.1 design requirement noted at roof level 1 section of scaffold erected over staircase installing blocks no guardrail no protection from worker falling down 20ft no design or permit provided rem: stop

    Mar 17, 2009 · Penalty $400

    Resolve
  • Class - 1

    Failure to safeguard all persons and property affected by constructionoperations noted at front of construction site sidewalk is broken cracked danger of someone tripping and hurting themselves rem: repair side

    Mar 17, 2009 · Penalty $1,200

    Resolve
  • Class - 1

    Failure to safeguard all persons and property affected by constructionoperations noted at staircase to roof their is no handrail rem: provide handrails

    Mar 17, 2009 · Penalty $1,200

    Resolve

Complaints

  • Water leak

    Heavy flow

    Sep 27, 2026 · Apt 6A

    Close
  • Paint/plaster

    Ceiling

    Aug 20, 2026 · Apt 6A

    Close
  • Unsanitary condition

    Pests

    Aug 20, 2026 · Apt 6A

    Close
  • Water leak

    Damp spot

    Aug 20, 2026 · Apt 6A

    Close
  • Unsanitary condition

    Pests

    Aug 20, 2026 · Apt 6A

    Close
  • Door/window

    Door

    Mar 15, 2026 · Apt BLDG

    Close
  • Water leak

    Heavy flow

    Feb 26, 2026 · Apt 9D

    Close
  • Heat/hot water

    Entire building

    Feb 1, 2026 · Apt 3A

    Close
  • Heat/hot water

    Entire building

    Jan 27, 2026 · Apt BLDG

    Close
  • Heat/hot water

    Apartment only

    Jan 25, 2026 · Apt 3B

    Close
Show 40 more ↓
  • Water leak

    Heavy flow

    Jan 9, 2026 · Apt 7C

    Close
  • Water leak

    Heavy flow

    Jan 5, 2026 · Apt 9D

    Close
  • Paint/plaster

    Ceiling

    Jan 5, 2026 · Apt 9D

    Close
  • Paint/plaster

    Wall

    Jan 5, 2026 · Apt 9D

    Close
  • Door/window

    Door

    Jan 5, 2026 · Apt 9D

    Close
  • Heat/hot water

    Apartment only

    Dec 27, 2025 · Apt 3D

    Close
  • Heat/hot water

    Apartment only

    Dec 16, 2025 · Apt 3B

    Close
  • Paint/plaster

    Ceiling

    Dec 16, 2025 · Apt 9D

    Close
  • Heat/hot water

    Entire building

    Dec 16, 2025 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Dec 15, 2025 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Dec 13, 2025 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Dec 5, 2025 · Apt BLDG

    Close
  • Unsanitary condition

    Pests

    Dec 3, 2025 · Apt 6B

    Close
  • Heat/hot water

    Apartment only

    Dec 3, 2025 · Apt 6B

    Close
  • Water leak

    Slow leak

    Dec 3, 2025 · Apt 5C

    Close
  • Unsanitary condition

    Mold

    Nov 10, 2025 · Apt 5C

    Close
  • Heat/hot water

    Apartment only

    Oct 27, 2025 · Apt 6B

    Close
  • Unsanitary condition

    Pests

    Oct 27, 2025 · Apt 6B

    Close
  • Unsanitary condition

    Pests

    Oct 27, 2025 · Apt 6B

    Close
  • Unsanitary condition

    Pests

    Oct 24, 2025 · Apt 6B

    Close
  • Electric

    Outlet/switch

    Oct 24, 2025 · Apt 6B

    Close
  • Paint/plaster

    Wall

    Oct 24, 2025 · Apt 6B

    Close
  • Paint/plaster

    Wall

    Oct 24, 2025 · Apt 6B

    Close
  • Paint/plaster

    Wall

    Oct 24, 2025 · Apt 6B

    Close
  • Unsanitary condition

    Pests

    Oct 24, 2025 · Apt 6B

    Close
  • Paint/plaster

    Ceiling

    Oct 24, 2025 · Apt 6B

    Close
  • Heat/hot water

    Apartment only

    Oct 24, 2025 · Apt 6B

    Close
  • Unsanitary condition

    Mold

    Oct 24, 2025 · Apt 6B

    Close
  • Water leak

    Heavy flow

    Oct 24, 2025 · Apt 5C

    Close
  • Paint/plaster

    Wall

    Aug 24, 2025 · Apt 5C

    Close
  • General

    Ventilation system

    Aug 23, 2025 · Apt 8D

    Close
  • Unsanitary condition

    Pests

    Aug 22, 2025 · Apt 8D

    Close
  • Plumbing

    Radiator

    Aug 22, 2025 · Apt 8D

    Close
  • General

    Ventilation system

    Aug 22, 2025 · Apt 8D

    Close
  • General

    Ventilation system

    Aug 12, 2025 · Apt 8D

    Close
  • Electric

    No lighting

    Aug 12, 2025 · Apt 8D

    Close
  • Unsanitary condition

    Pests

    Jul 31, 2025 · Apt 6B

    Close
  • Unsanitary condition

    Mold

    Jul 31, 2025 · Apt 6B

    Close
  • Flooring/stairs

    Floor

    Jul 31, 2025 · Apt 6B

    Close
  • Paint/plaster

    Ceiling

    Jul 31, 2025 · Apt 6B

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D1)
Year built
2008
Floors
9
Residential units
39
Building area
40,633 ft²
Lot area
7,188 ft²
Zoning
R8
Community board
205
Council district
14
Block / lot
2829 / 62
Assessed value
$1,173,600
Landmark / historic district
No

HPD registration #226604, last renewed Jul 31, 2025.

Questions about 2017 Morris Avenue

Who owns 2017 Morris Avenue?

The owner of record in NYC Department of City Planning PLUTO data is 2017 Morris Avenue Housing Development F Und Co INC.

Does 2017 Morris Avenue have violations?

Yes. NYC HPD has recorded 109 housing violations at this property.

Is 2017 Morris Avenue rent stabilized?

NYC Department of Finance tax bills listed 39 rent-stabilized units here in 2024 (about 100% of its 39 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 2017 Morris Avenue built?

City records list 2008 as the year it was built.

How many apartments are in 2017 Morris Avenue?

It has 39 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.