1800 Grand Concourse
Bronx, NY 10457BBL 2-02826-0087Map
Owner of record: Pilgrim United Church
1800 Grand Concourse is a religious facility built in 1920 in Bronx, 10457. The owner of record is Pilgrim United Church. HPD has recorded 7 housing violations here, most recently on March 15, 2017. 3 of the 7 most recent violations are still open.
- HPD violations
- 7
- DOB violations
- 76
- ECB violations
- 52
- HPD complaints
- 1
What to know
Immediately hazardous issues among recent violations are still open.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 7
- CImmediately hazardous
Abate the nuisance consisting of missing bolt caps at side walk shed
Mar 15, 2017
Open — Nov sent out - CImmediately hazardous
M/d law abate the nuisance consisting of missing bolt caps (21) at sidewalk shed
Dec 14, 2016
Open — Nov sent out - CImmediately hazardous
Abate the nuisance consisting of no lights through out at sidewalk shed
Dec 13, 2013
Open — Nov sent out - CImmediately hazardous
Abate the nuisance consisting of unsecured bolt-caps through out at sidewalk shed
Dec 13, 2013
Closed — Violation closed - CImmediately hazardous
M/d law abate the nuisance consisting of missing apron at southwest of sidewalkshed
Jun 13, 2013
Closed — Violation closed - CImmediately hazardous
M/d law abate the nuisance consisting of of loose inner mudsills and uprights at south of sidewalk shed
Jun 13, 2013
Closed — Violation closed - CImmediately hazardous
M/d law abate the nuisance consisting of no bolt caps and or duct tape on bolt ends at sidewalk shed at bldg front
Sep 2, 2012
Closed — Violation closed
DOB building violations · 76
- Construction other optional
Failure to maintain building in a code compliant manner as per section 28.301.1 of the nyc admin code.as noted at time of inspection,premises appears to be vacant with signs of deterioration of facade,brick mason ry damaged,countless broken glass windows.remedy:repair and/or replace
Jul 7, 2026
Dob violation - active - Unsafe buildings none
Ub-unsafe buildings none
Jan 9, 2026
V%-dob violation - Immediate emergency anythingoptional
Repair temporary fencing and sidewalk shed as needed (apprx. 300 sf) remove debris from the sidewalk and premises
Jan 9, 2026
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2024 external low pressure inspection
Nov 14, 2025
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2024 external low pressure inspection
Nov 14, 2025
Dob violation - active - Construction other optional
Failure to maintain construction fence. observed at east 174th street exposure, section of construction fence missing approximately 12 linear feet of fence.
Jan 24, 2025
Dob violation - active - Construction other optional
Owner to hire nyspe to submit report [email protected] with 5 days, addressing all conditions w/plans, photos, recommending time frame and repairs to be completed.
Jan 24, 2025
Dob violation - active - Construction other optional
Structure rendered non-compliant due to abandoned church open to the elements, structural stability in question.
Jan 24, 2025
Dob violation - active - Immediate emergency anythingoptional
Repair the consturction fence @ expo#3 and any other indentify opening s to secure the property, prevent unauthorized entry, and ensure publi c safety
Jan 24, 2025
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2023 external low pressure inspection
Sep 23, 2024
Dob violation - active
Show 40 more ↓
- Low pressure boiler boiler required
Violation issued-failure to file 2023 external low pressure inspection
Sep 23, 2024
Dob violation - active - Construction other optional
Structure rendered non compliant due to vehicle striking sidewalk shed. displacing approximately 30 linear feet of shed. panels and bracing damaged.
Nov 18, 2023
Dob violation - active - Immediate emergency anythingoptional
Replace approximately 40 linear feet of sidewalk at expo #1 (grand concourse) and 4(eastburn ave) & approximately 24 linear feet of repairs to the sidewalk shed at expo#3 (east 175 st), in addition to approx- 30 linear feet of construction fence at expo#4 (eastburn ave) to safeguard the public
Nov 18, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - active - Immediate emergency anythingoptional
Immediate repair/replace approximately 24 lf of construction fence at exp#3 ( east 175 street)
Jun 17, 2022
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Apr 13, 2022
Dob violation - active - Immediate emergency anythingoptional
Replace all missing parapet panels, loose decking and deteriorated lumber
Jan 25, 2022
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 26, 2021
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Nov 8, 2019
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Nov 8, 2019
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Aug 22, 2018
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 11, 2018
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 30, 2018
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2016 inspection report
Apr 6, 2018
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2016 inspection report
Apr 6, 2018
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 31, 2017
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2015 inspection report
Feb 24, 2017
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2015 inspection report
Feb 24, 2017
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Aug 24, 2016
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 13, 2016
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 1, 2016
Dob violation - active - Emergency none
Egncy-emergency none
Apr 19, 2016
Dob violation - active - Emergency none
This supercedes ied #9303
Apr 19, 2016
Dob violation - dismissed - Immediate emergency anythingoptional
Imegncy-immediate emergency anythingoptional
Mar 8, 2016
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2011 inspection report
Mar 1, 2013
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2011 inspection report
Mar 1, 2013
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 2, 2013
Dob violation - active - Immediate emergency anythingoptional
Also associated with violtions# 35000124j & 35006526j
Dec 10, 2012
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2010 inspection report
Dec 13, 2011
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2010 inspection report
Dec 13, 2011
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Nov 16, 2011
Dob violation - active
ECB violations · 52
- Class - 2
Temporary construction equipment 1 fence on site has expired permit. as noted at time of inspection observed erected construction at 1800 grand concourse had no valid permit posted. also place of occurrence had
Jul 7, 2026 · Penalty $1,280
Active - Class - 2
In respond to complaint, i observed existing jobsite construction fence with expired permit in places at exposure 1&4. upon search in bis system & dob now for renewed compliance purposes none found.. fence perm
Nov 5, 2025 · Penalty $6,250
Active - Class - 2
In respond to complaint, i observed existing sw shed in places at sidewalk exposure 1&4 not maintained and with expired permit. upon search in bis system & dob now for renewed compliance purposes, none was foun
Nov 5, 2025 · Penalty $6,250
Active - Class - 1
Interrupted or abandoned operation 3303.13- owner of site failed to ensure & safeguard the public & property for not in compliance- sws &. fence with loose plywood, obstructing & exposing public to site, protr
Nov 5, 2025 · Penalty $10,000
Active - Class - 2
At time of inspection of a 2-story vacated church building, i observed sidewalk shed erected exposure#1-4.upon reviewing dob now and bis system show permit expired since 08/15/2024 and has not renew as per code
Apr 22, 2025 · Penalty $6,250
Active - Class - 2
At time of inspection of a 2-story church building, i observed construction fence erected exp#1-4. upon reviewing department of building records show fence permit expired since 07/12/2023 ,and has not renew as
Apr 22, 2025 · Penalty $6,250
Active - Class - 2
At time of inspection of 2-story vacated building, i observed sidewalk shed not maintained as per code 1-broken and rotten mudsill various location 2-no caps for sharp edges 3-cross bracing not connected 4-para
Apr 22, 2025 · Penalty $10,000
Active - Class - 2
Failure to comply with commissioners order to file a cert of correction with the dept of buildings. noted violation #35543987x issued at agg 1 level 02/26/2021 for construction fence installed at perimeter of s
Jun 16, 2022 · Penalty $10,000
Active - Class - 2
Failure to maintain bldg in code compliant manner. observed bldg is severly deteriorating conditions at all exposures. damage steeples,cornice broken window pane & damage frames. remedy: repair &/or replace.
Mar 21, 2022 · Penalty $3,125
Active - Class - 2
Sidewalk shed does not meet code specification.note observed at exp1 and 3 sidewalk shed missing section of parapet approx 4x8 long.remedy:conform shed to code specifications.
Jan 18, 2022 · Penalty $10,000
Active
Show 40 more ↓
- Class - 2
Work without a permit.note observed sidewalk shed erected at exp1,3,and 4 with no valid permit posted on site.also observed a construction fence erected at exp1,3,and 4 with no valid permits posted on site.no v
Jan 18, 2022 · Penalty $6,250
Active - Class - 1
Failure to maintain building in code compliant manner.observed at exp1,2,3,and 4 severely deteriorating chruch steeple missing/broken windowpanes,deteriorating cornice and loose flashing.remedy:repair and loose
Jan 18, 2022 · Penalty $6,250
Active - Class - 2
Permit expired for temporary construction equipment(sidewalk shed) on site note:at the time of inspection observed a heavy duty sidewalk shed at expo.#1,3 & 4 on a 2 sty church bldg.also observed in dob system
Feb 26, 2021 · Penalty $10,000
Active - Class - 1
Housekeeping note:at the time of inspection observed a bldg(church) surrounded by construction fence 2 sidewalk shed at expo#1,3 & 4.also observed piles of debris like discarded furnitures,woods,household items
Feb 26, 2021 · Penalty $12,500
Active - Class - 2
Pedestrian protection does not meet code specification bc3307.6.4.8., bc3307.6.4.6 & bc3307.6.5 note:at the time of inspection observed a church bldg,surrounded by construction fence & sidewalk shed.also observ
Feb 26, 2021 · Penalty $10,000
Active - Class - 2
Missing parapet information panel note:at the time of inspection observed church bldg,surrounded by construction fence & sidewalk shed.also observed missing parapet information panel on this sidewalk shed at ex
Feb 26, 2021 · Penalty $6,250
Active - Class - 2
Work w/out permit note:at the time of inspection observed a church bldg surrounded by construction fence at exposure #1,3 & 4.also observed in dob system no permit for this construction equipment(fence)mean wor
Feb 26, 2021 · Penalty $10,000
Active - Class - 2
Temporary construction equipment on site expired permit:sidewalk shed.at the time of inspection observed 175' linear ft of sidewalk shed installed at premises w/ an expired sws permit. sidewalk shed permit#2205
Apr 10, 2019 · Penalty $6,250
Active - Class - 2
Pedestrian protection does not meet code specifications:sidewalk shed.at the time of inspection,observed premises sidewalk shed w/ missing panels of the parapet wall of approx 4'x5'ft at exposure#1 and #4 of th
Apr 10, 2019 · Penalty $10,000
Active - Class - 2
Failure to comply w/commissioner's order contained in summons/violation #35334277k issued on 05/27/18 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01. for failure to maintain con
Jul 7, 2018 · Penalty $3,125
Resolve - Class - 2
Failure to comply w/the comm's order contained in summons/vio#35329184p issued on 04-18-18 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. for: failure to maintain front fence(open construction fence).
Jul 7, 2018 · Penalty $3,125
Resolve - Class - 1
Failure to provide a building in code-compliant manner. observed: front side fence. missing 4 x 8 feet panel horizontally and upper section. providing access to site (open construction fence). rem: replace or r
May 27, 2018 · Penalty $6,250
Active - Class - 1
Failure to maintain building in code compliant manner.at the time of inspection 4x8 panel(horizontally)an upper section to misisng,provide access to site (open construction fence)rem:replace and/or repair.
Apr 18, 2018 · Penalty $12,500
Active - Class - 1
Failure to maintain building in code compliant manner.@ time of inspection the violating conditions are as follows.1)missing construction fence panels providing access to site.2)open construction fence down.3)e
Feb 28, 2018 · Penalty $5,000
Active - Class - 3
Work w/o permit.at time of inspection the violating conditions are as follows:job site fence erected at exp 1,2 and 4.w/o permit on record.job #220511033-01-eq-sh expd w/shed alsso.rem:obtain permit or restore
Feb 28, 2018 · Penalty $500
Active - Class - 2
Temporary construction equipment on site-expired permit.noted:at time of inspection permit for the sidewalk shed expired on 5/19/17.rem:renew shed permit.
Jun 9, 2017 · Penalty $4,000
Active - Class - 2
Bc3307.6.5.3/failure to maintain sidewalk shed in order.noted:at time of inspection parapet wall panel for the sidewalk shed is detached/missing.a few underside lights are missing.rem:maintain sidewalk shed in
Jun 9, 2017 · Penalty $4,000
Active - Class - 2
As per class 2 (b265) 28-303.7 failure to file a complete boiler insp as per dob records submit a current bo-9 report.
Jun 6, 2017 · Penalty $2,500
Active - Class - 2
As per class 2 (b265) 28-303.7 failure to file a complete boiler insp as per dob records. submit a current bo-9 report.
Jun 6, 2017 · Penalty $2,500
Active - Class - 2
Failure to maintain bldg walls or appurtenances. noted: at exp#1,facial board above 2nd fl windows at north side at bldg has detached & hangs loose in danger of dislodging gutter. remedy: comply w/code/maintain
Apr 29, 2017 · Penalty $5,000
Active - Class - 1
Failure to maintain bldg walls or appurtenances. at exp#1 facial boardabove 2nd fk windows at north side at bldg has detached & hangs loose an danger of dislonging gutter. remedy: maintain exterior bldg wall.
Mar 5, 2017 · Penalty $5,000
Active - Class - 1
Failure to maintain bldg walls or appurtenances.@ south elevation,roof(eve) gutters & cornice dislodged & fell to grade w/in lot line.@ n/w section wooden decorative cornice is loose & in danger of dislodging,
May 23, 2016 · Penalty $5,000
Active - Class - 1
Failure to maintain building wall(s) or appurtenance.maintain exteriorbldg wall, noted: at exp#1 wood fascia board above 2nd flr windows at north side at bldg has detached and hangs loose an dis in danger of fi
Apr 14, 2016 · Penalty $5,000
Active - Class - 1
Failure to maintain bldg walls a appurtenances. noted: at exp#1 wood fascia board above 2nd fl windows at north side at bldg has detached & hangs loose & is in danger of filling,also noted at main entrance,wood
Mar 7, 2016 · Penalty $5,000
Active - Class - 2
Failure to maintain bldg in code complaint manner. noted: in main hallof church,done ceiling has large section of plaster finish missing,also noted extensive water damage from roof has penetrated done & has
Mar 7, 2016 · Penalty $2,500
Active - Class - 2
Sec. 3307.6.5.3 maintenance & use. failed to maintain sidewalk shed. noted: at time of inspection several mud sills for sidewalk shed at exp#1 & #2 broken/rotten. remedy: comply w/code/maintain shed in wood ord
Mar 4, 2015 · Penalty $4,000
Active - Class - 2
Temporary construciton equipment on site-expired permit. noted: at time of inspection permit for sidewalk shed at exp#1 & #2 expired on 1/24/09 recurring condition. previous vio #35031903k issued on 12/23/13.
Mar 4, 2015 · Penalty $4,000
Active - Class - 2
Failure to maintain exterior.defect is:rotted wood at various locations of exterior & roof.rem:obtain permits,repair defects.
Mar 13, 2014 · Penalty $2,500
Active - Class - 2
Failure to comply with commissioner's order to file certificate of corrections for all open violations.rem:file certificates of correction.
Mar 13, 2014 · Penalty $4,000
Active - Class - 2
Sidewalk shed does not meet code specifications. note:underside sidewalk shed lights are not lit. rem:conform shed to code specifications.
Dec 23, 2013 · Penalty $10,000
Active - Class - 2
Temp construction equipment on site - expired permit. noted: at time of inspection sidewalk shed permit is exp on 1.24.09.
Dec 23, 2013 · Penalty $4,000
Active - Class - 2
Sidewalk shed does not meet code specifications. noted: sidewalk shed is in disrepair in front of premises: corner of grand concourse, e 175st, and east burns ave steel pipe column is out of place, bent railing
Dec 3, 2012
Resolve - Class - 2
Work w/o a permit. expired permit noted: sidewalk shed permit #210047144-01-eq-sh issued 4.25.08 expired: 1.24.09 not renewed. remedy: renewpermit.
Dec 3, 2012
Resolve - Class - 2
Failure to provide/post sign(s) at job site pursuant to subsection. noted: at installed sidewalks shed, no contractors name, address, contact telephone & job # posted on sidewalk/shed permit.210047144-01-eq-sh
Dec 3, 2012
Resolve - Class - 1
Failure to maintain bldg walls or appurtenances. defects noted:wood eaves & wood ornmenation at roof & portico is splitting & missing sections with pieces hanging loosely in danger of falling at an facade expos
Aug 31, 2012 · Penalty $5,000
Active - Class - 2
Failed to obtain a temporary construction permit prior to installationuse of sidewalk shed. note:heavy duty sidewalk shed erected at 18 floor(exterior)perimeter of bldg vin application #210047144 has expired
Aug 31, 2012 · Penalty $2,500
Active - Class - 2
Work without permit. work noted:81foot high plywood construction fenceerected at 18th flr exterior perimeter or bldg made of plywood sheathing & wood frames. rem:obtain permit.
Aug 31, 2012 · Penalty $4,000
Active - Class - 1
Failure to maintain bldg in code-compliantt manner. noted: at front ofbldg exp 1, grand concourse broken decorative column, at roof, corniceis in disrepair, wood rotten & falling apart. sidewalk shed installed
Aug 18, 2011 · Penalty $5,000
Active - Class - 1
Failure to comply w/ an order of the commissioner.note:@ time of inspection no cert of correction file for ecb34611276p issued 3/29/08 failure to maintain exterior bldg wall hazardous,conditions still exist.rem
Jun 30, 2011 · Penalty $12,000
Resolve - Class - 2
Work w/o a permit. expired permit. noted: sidewalk shed installed under permit 210047144-01-eq-sh alt 3 issued 4.25.08 and expired 1.24.09 no permit renewed & sidewalk shed still erected and present at exps
Jun 30, 2011 · Penalty $4,000
Active
Complaints
- Electric
No lighting
Oct 27, 2023 · Apt 5J
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Religious facility (M1)
- Year built
- 1920
- Floors
- 2
- Residential units
- —
- Building area
- 9,000 ft²
- Lot area
- 5,169 ft²
- Zoning
- R8
- Community board
- 205
- Council district
- 14
- Block / lot
- 2826 / 87
- Assessed value
- $264,600
- Landmark / historic district
- No
Questions about 1800 Grand Concourse
Who owns 1800 Grand Concourse?
The owner of record in NYC Department of City Planning PLUTO data is Pilgrim United Church.
Does 1800 Grand Concourse have violations?
Yes. NYC HPD has recorded 7 housing violations at this property.
Is 1800 Grand Concourse rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 1800 Grand Concourse built?
City records list 1920 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.