roofy

1817 Topping Avenue

Bronx, NY 10457BBL 2-02800-0046Map

Owner of record: 1817 Topping Holdings LLC

1817 Topping Avenue is a walk-up apartment building built in 2022 in Bronx, 10457. It has 13 residential units across 4 floors. The owner of record is 1817 Topping Holdings LLC. HPD has recorded 3 housing violations here, most recently on April 15, 2026. 1 of the 3 most recent violations are still open. City tax records listed 13 rent-stabilized apartments here in 2024.

HPD violations
3
DOB violations
3
ECB violations
21
HPD complaints
10

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Apr 15, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
13
About 100% of the building's 13 apartments

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 3

  • B

    Properly repair or replace the broken or defective intercom system from entrance of buiding to apt 1c west 1, 1st floor at south wall panel in the entrance located at apt 1c, 1st story, 1st apartment from south at west

    Apr 15, 2026 · Apt 1C

    Open — Nov sent out
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 17, 2025

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Jun 16, 2025

    Closed — Violation dismissed

DOB building violations · 3

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    May 11, 2022

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    May 11, 2022

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    May 11, 2022

    Dob violation - dismissed

ECB violations · 21

  • Class - 2

    Installed overhead protection at exp2. upon request, no design drawing for the overhead protection was provided. g.c failed to display or maintain code required documents on site. provide design drawing overhea

    Nov 28, 2022

    Resolve
  • Class - 2

    Installed manual suspended scaffold was observed at exp2 without dob notification. g.c failed to notify dob prior to its installation. no exterior work and use of manual suspended scaffold is allowed. notify d

    Nov 28, 2022 · Penalty $2,500

    Resolve
  • Class - 2

    Approved plan a-310.00 shows 4" concrete floor over metal decking but installed flooring does not conform to the approved plan. g.c failed to conform to approved construction documents. conform to plan or amend

    Nov 28, 2022 · Penalty $1,250

    Resolve
  • Class - 2

    At the time of inspection, observed accumulated water at cellar level. g.c failed to maintain adequate housekeeping as per code. remove pooling water at cellar level

    Nov 28, 2022

    Resolve
  • Class - 1

    Unlawfully continued work while on notice of stop work order.at time of inspection of inactive nb site observed exterior wall of exp #1 made of cmu review of bis & dob now observed full stop work order exists o

    May 5, 2022 · Penalty $5,000

    Resolve
  • Class - 1

    Unlawfully continued work while on notice of a stop work order.at the time of inspection i observed,construction site was active & performing work against stop work order(com#2331568)which was posted on(2/14/22

    Apr 19, 2022 · Penalty $5,000

    Resolve
  • Class - 2

    Failure to safeguard all person & property affected by construction operations.at the time of inspection i observed performing work on superstructure on 3rd fl.working on cmv all around bldg perimeter.there was

    Apr 19, 2022

    Resolve
  • Class - 1

    Bc3301.2 failulre to provide overhead protection at exp.#2.at the timeof inspection i observed performing super structure framing work & working on cmv block at exp.#2(rear yard)of the adjacent property.there

    Apr 19, 2022

    Resolve
  • Class - 1

    Construction superintendent failed to perform duties as per code.at the time of inspection i observed multiple violating condition on activeconstruction site incl. no safety measures,unstable scaffold,no roof

    Apr 19, 2022 · Penalty $10,000

    Resolve
  • Class - 1

    Bc3309.14 failure to provide protection for the windows.at the time ofinspection i observed performing cmv work at 3rd fl exp.#4.there was windows by the adjacent property(exp.#4)which was not protected,which

    Apr 19, 2022 · Penalty $1,250

    Resolve
Show 11 more ↓
  • Class - 1

    Work does not conform to approved construction documents.at the time of inspection i observed.foundation wall at exp.#3 rear yard,which wasunder grade level,which was contrary to approved construction document

    Apr 19, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Bc1704.1 failure to file tr1 prior to the commencement of work.at the time of inspection i obsered performing work on super sturcture framing w/cold form steel & cmv blocks.there was no special inspection repor

    Apr 19, 2022 · Penalty $1,250

    Resolve
  • Class - 1

    Bc3314.1 failure to maintain supported scaffold.at the time of inspection,construction site was active & performing cmv work on supported scaffold.i observed scaffold was missing guardrail system.no toe-boards,

    Apr 19, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Bc3301.2 failure to provide/maintain safety measures.at the time of inspection i observed,performing cmu work at open perimeter at exp.#1 & #4 on 3rd fl.there was no guardrails in place & there was no control a

    Apr 19, 2022 · Penalty $1,250

    Resolve
  • Class - 1

    Bc3309.10 failure to provide roof protection for adjacent property.at the time of inspection,i observed performing cmv work on 3rd fl at exp#2.permit holder unable to provide roof protection for adjacent bldg.

    Apr 19, 2022

    Resolve
  • Class - 1

    Housekeeping inadequate.ato my insp of proposed 4styb@1fl level work in progress.i noticed following violated condition creating a hazard condition for workers(1)garbage stored@staircase(2)large open area aprx1

    Feb 14, 2022 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to provide temp handrails on structure ato my insp of proposed4styb@1fl level work in progress.i noticed stairwell from 1fl-cellar that had no handrail system in place while workers were using it.this c

    Feb 14, 2022 · Penalty $1,250

    Resolve
  • Class - 2

    Jobsite fence not const as per code ato my insp of proposed 4styb@1fl level.i noticed const fence missing as per code require full enclosed const w/fence.this creates situation w/unauthorized entering jobsite.c

    Feb 14, 2022 · Penalty $1,000

    Resolve
  • Class - 1

    Bc3301.2 failure to provide safety measures ato my insp of proposed 4styb@1fl level work in progress.i noticed makeshift ramp@exp3 ramp was made from plywood&2x4 underneath.used to access part of rearyd due to

    Feb 4, 2022 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to notify department prior to cmmencement of earthwork.at time of inspection observed excavation work commenced in rear of premises was adjacent to adjacent to adjacent to adjoining property's foundatio

    Dec 7, 2021 · Penalty $2,500

    Resolve
  • Class - 2

    Fence not maintained pursuant to subsection.at time of inspection observed aprox 12 foot section of construction fence underminded by excavation work had falled over at exp #2 condition posed major hazard for a

    Dec 7, 2021

    Resolve

Complaints

  • Unsanitary condition

    Pests

    Jan 26, 2026 · Apt 1C

    Close
  • General

    Bell/buzzer/intercom

    Jan 26, 2026 · Apt 1C

    Close
  • General

    Ventilation system

    Jan 26, 2026 · Apt 1C

    Close
  • Electric

    Outlet/switch

    Jan 26, 2026 · Apt 1C

    Close
  • Paint/plaster

    Ceiling

    Jan 26, 2026 · Apt 1C

    Close
  • Paint/plaster

    Ceiling

    Jan 13, 2026 · Apt 1C

    Close
  • General

    Ventilation system

    Jan 13, 2026 · Apt 1C

    Close
  • Electric

    Outlet/switch

    Jan 13, 2026 · Apt 1C

    Close
  • Unsanitary condition

    Pests

    Aug 13, 2025 · Apt 1C

    Close
  • Plumbing

    Water supply

    Jun 24, 2025 · Apt 4C

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Walk-up apartment building (C1)
Year built
2022
Floors
4
Residential units
13
Building area
6,747 ft²
Lot area
2,620 ft²
Zoning
R7-1
Community board
205
Council district
14
Block / lot
2800 / 46
Assessed value
$589,950
Landmark / historic district
No

HPD registration #229168, last renewed Feb 11, 2026.

Questions about 1817 Topping Avenue

Who owns 1817 Topping Avenue?

The owner of record in NYC Department of City Planning PLUTO data is 1817 Topping Holdings LLC.

Does 1817 Topping Avenue have violations?

Yes. NYC HPD has recorded 3 housing violations at this property.

Is 1817 Topping Avenue rent stabilized?

NYC Department of Finance tax bills listed 13 rent-stabilized units here in 2024 (about 100% of its 13 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 1817 Topping Avenue built?

City records list 2022 as the year it was built.

How many apartments are in 1817 Topping Avenue?

It has 13 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.