101 Macombs Place
Manhattan, NY 10039BBL 1-02040-0023Map
Owner of record: 101 Macombs Place LLC
101 Macombs Place is an elevator apartment building built in 2021 in Manhattan, 10039. It has 30 residential units across 7 floors. The owner of record is 101 Macombs Place LLC. HPD has recorded 1 housing violation here, most recently on May 11, 2026. City tax records listed 16 rent-stabilized apartments here in 2024.
- HPD violations
- 1
- DOB violations
- 16
- ECB violations
- 47
- HPD complaints
- 9
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.
Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 1
- ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
May 11, 2026
Closed — Violation dismissed
DOB building violations · 16
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 9, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Nov 28, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 31, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 5, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 25, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 13, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Apr 4, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Feb 21, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 27, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 27, 2017
Dob violation - dismissed
Show 6 more ↓
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Nov 29, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Nov 29, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 12, 2017
Dob violation - dismissed - Construction other optional
Fm bldg.port of cellar ceiling,comprised of wood framing&wire lathe & plaster&suspended from ceiling above,collapsed on 1/26/17,likely due to water intrusion.other areas are in danger of collapse.remedy:owner to remove entire area of suspended ceiling&to retain eng'r or arch(nys lic)to assess adequacy of ceiling to remain
Mar 27, 2017
Dob violation - dismissed - Construction other optional
(28-502.4) unreg
Dec 7, 2013
Dob violation - dismissed - Construction other optional
C-construction other optional
Jun 13, 1990
Dob violation - dismissed
ECB violations · 47
- Class - 2
Standpipe(sd) not painted red-3303.8i observed active jobsite of nb with 75f and 7 floors listed height with workers on several floors. upon walking up the stair a and b, i discovered that the sd in readiness
Apr 13, 2022
Resolve - Class - 2
Expired dot permitsi observed active crane operations at exp1, delivery of gypsum boards. upon request from competent person(cp) to view the dot permits for the legal occupation of the roadway, i was provided
Apr 13, 2022
Resolve - Class - 2
Bc3301.7 failure to provide aproved p.e. details/eor.as noted:at time of inspection for an active construction site up to bulkhead level.observed at 1st fl(1) chipping for new opening or/enlarge existing openin
Dec 28, 2021
Resolve - Class - 1
Work does not conform to construction documents &/or amendments. at time of inspection observed supported scaffold in place. at exp#1 observed u-jacks installed to support the load of the supported pipe scaffol
Dec 27, 2021 · Penalty $312
Resolve - Class - 2
Sec. bc3314.3.4 load improsed-inadequate load imposed letter. at time of inspection observed a supported scaffold sitting on a sidewalk shedin place @ exp#2&4. upon request of the loads imposed letter sign,seal
Dec 27, 2021
Resolve - Class - 1
Unlawfully continued work while on notice of a stop work order.at the time of inspection of a new bldg currently on 7fl level w/designated competetent person by name on joel landau person on site.i noted a 7sw
Sep 3, 2021 · Penalty $5,000
Resolve - Class - 2
Failure to comply w/ manufacturer specifications. at time of inspection at 7 story building,i observed jersey barriers not properly assembled as per manufacturer specifications. this creates a hazard to public&
Jul 16, 2021
Resolve - Class - 2
Bc3309.2 license to enter adjoining property.at time of inspection of 7 story new building at 5 story framing/pour active jobsite observed overhead protection in place on the roof of adjoining building at exp3
Jun 3, 2021
Resolve - Class - 1
Illegally engaging in any business or occupation w/out a required license.at time of inspection on a proposed 7-story new bldg currently pouring 4th fl observed concrete pouring operations in progress w/a total
Jun 3, 2021
Resolve - Class - 1
Bc3301.2 failure to maintain/institute safety measures;fall protectionat time of inspection on a proposed 7-story bldg currently pouring the4th fl deck observed inadequate vertical netting at the perimeter edge
Jun 3, 2021
Resolve
Show 37 more ↓
- Class - 1
Failure to communicate site specific hazards during pre-shift safety meeting.at time of inspection on a proposed 7-story new bldg currentlypouring 4th fl concrete deck observed various construction operations
Jun 3, 2021
Resolve - Class - 2
Pedestrian protection does not meet code specification.at time of inspection on a proposed 7 story new bldg currently pouring the 4th fl deck observed hazards at exp.#1 in the pedestrian walkway & roadway due
Jun 3, 2021
Resolve - Class - 2
Bc3309.10 roof protection-exp.#2 at time of inspection on a proposed 7-story new bldg currently pouring 4th fl level observed at exp.#2 a sidewalk bridge on top of 1 story bldg roof leve w/no roof protection in
Jun 3, 2021
Resolve - Class - 2
Bc3305.3.6.1.2 reshores in proximity to unenclosed perimeters at time of inspection on a proposed 7-story new bldg currently pouring 4th fl deck observed at exp.#4 2nd fl level reshores approx.1-2 ft at perimet
Jun 3, 2021
Resolve - Class - 2
Construction superintendent failed to do duties per code.at time of inspection on a proposed 7-story new bldg currently pouring 4th fl levelobserved multiple safety hazards in which the site was issued a full
Jun 3, 2021 · Penalty $2,500
Resolve - Class - 1
Bc3309.1 failure to provide property protection & persons at risk.at time of inspection on a proposed 7-story new bldg currently pouring the 4th fl deck observed no property or pedestrian protection in place
Jun 3, 2021
Resolve - Class - 2
Matters not provided for;inspection for concrete embedded safety straps.at time of inspection on a proposed 7-story new bldg currently pouring the 4th fl deck observed worker at 2nd fl level tied off to concret
Jun 3, 2021
Resolve - Class - 2
Failure to renew a temporary construction permit prior to installation /use of temporary construction equipment.at time of inspection of 7 story new building at 5 story framing/pour active jobsite observed cons
Jun 3, 2021
Resolve - Class - 1
Bc 3301.6.1 sws design drawings.at time of inspection of 7 story new building at 5 story framing/pour active jobsite observed overheard pedestrian protection-sidewalk shed at exp #1 and 2.upon request of regist
Jun 3, 2021
Resolve - Class - 2
Work does not conform to approved/accepted documents-ssp.at time of inspection of 7 story new building at 5th story framing/pour active jobsite observed construction fence missing at exp #4 and pipe scaffold/ov
Jun 3, 2021
Resolve - Class - 1
Permit holder failed to ensure workers receive site safety orientationor refresher.at time of inspection on a proposed 7-story new bldg currently pouring the 4th fl slab observed approx. 25 workers engaging in
Jun 3, 2021
Resolve - Class - 2
28-105.12 condition of new building permit.noted:at time of inspection for active construction site at 3rd floor (slub) level observed building constructed as concrete corst in place (cip).not conform to new bu
May 19, 2021
Resolve - Class - 1
Work does not conform to approved construction documents and or approved amendments:as noted:at time of my inspection at an active const site observed at exposure#1 solider pile w/ lagging in place but no rebar
Jan 26, 2021 · Penalty $2,500
Resolve - Class - 2
Bc 28-105.5 forms filed w/ dob do not have required signatures:as noted at time of my inspection observed at exposure#1 rebar and formwork been build,for new building on reviewing trs for special inspection fil
Jan 26, 2021 · Penalty $625
Resolve - Class - 2
Bc3308.7=inadequat econstruction guardrails (exposure 4) at the time of inspection i observed that teh guardrial at exposure 4 above the adjoining property was poorly constucted and was missing adequate boards
Mar 4, 2020
Resolve - Class - 2
Job site fence not const or maintained pursuant to subsection. @the time of inspection @ a alt/demo site, i observed the const fence inadequate to (edge). noted 4 viewinf panels and plywood was not tighten or
Aug 28, 2019
Resolve - Class - 2
Failure to comply with the commissioner's order contained in summons/ violation #35361721l issue don 10/16/18 and to file a certificate of correction pursuant to 28-201.1 and 1rcny102-01. rmdy: comply with
Mar 30, 2019 · Penalty $1,250
Resolve - Class - 2
Failure to comply with the commissioners order contained in summons/ violation # 35361721l issued on10/16/18 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01.remedy:comply with
Dec 13, 2018 · Penalty $1,250
Resolve - Class - 1
Failure to maintain buildings in code-compliant manner.noted: @ time of inspection observed @ front facade bricks are falling and observed cracks and missing mortar.stucco and stones visibly rotten.also block w
Oct 16, 2018 · Penalty $3,125
Resolve - Class - 1
Failure to maintain building in code-compliant manner. noted: at front facade bricks are falling and observed cracks & missing mortar. stucco and stones visibly rotten. also block wall is bulging and in disrep
Sep 5, 2018 · Penalty $3,125
Resolve - Class - 1
Failure to maintain bldg in code compliant manner. @ time of insp, front facade is falling apart bricks & mortar joints cracked,missing & deteriorating. loose & dangerous railing & metal awning frame are a dang
Jul 28, 2018 · Penalty $1,250
Resolve - Class - 1
Failure to maintain bldg in code compliant manner. noted: at exp#1 facade is in disrepair stucco cracked & missing. mortar joints missing stucco above entrance door loose & door frame wood is rotten due to it
Jun 12, 2018 · Penalty $1,250
Resolve - Class - 1
Failure to maintain bldg in code-compliant manner.noted:@exp#1,bldg front facade in a state of disrepair observed,cracks, missing mortar, (stuco), stones,visible rotten wood from from entrance door in danger of
May 4, 2018 · Penalty $1,563
Resolve - Class - 1
Failure to maintain building in code-compliant manner. noted: at the time of inspection i observed the facade at exp1 the facade is crackedin multiple areas with missing bricks/mortar.a damaged awning is conn
Mar 13, 2018 · Penalty $1,250
Resolve - Class - 1
Failure to maintain bldg in code compliant manner at itme of inspection i observed throughout bldg facade cracked missing bricks/mortar,masonry,damaged missing awning broken, damaged missing metal fence.rmdy: r
Jan 10, 2018
Resolve - Class - 1
Failure to maintain building in code compliant manner.note:this building is in need of desperate repair.the awning frame is about to fall off.the brick steps and sidewalks are cracked and deteriorating and ve
Dec 2, 2017 · Penalty $5,000
Resolve - Class - 1
Re-issue violation #35287423k issued 8/18/17.failure to maintain bldg in code-compliant manne.note:this bldg is in need of desperate repair.the awning frame is about to fall off. the brick steps and sidewalks
Oct 4, 2017 · Penalty $2,500
Resolve - Class - 1
Re-issue viol#35287422z isued 8/18/17.failure to maintain bldg wall(s)or appurtenances.note:at the front exp#1 wall facing macombs place several areas are falling apart,masonry in bldg wall cracking and deterio
Oct 4, 2017 · Penalty $2,500
Resolve - Class - 1
Failure to maintain bldg in code compliant manner. this bldg is in need of desperate repair. the awning frame is about to fall off. the brick steps & sidewalks are cracked & deteriorating & very uneven cousing
Aug 18, 2017 · Penalty $2,500
Resolve - Class - 2
Failure to comply with the commissioner's order contained in summons/vio # 35244350z issued on 04/19/17 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. drains clogged & severe accumulation of water bldg
Aug 18, 2017 · Penalty $2,000
Resolve - Class - 1
Failure to maintain bldg wall(s) or appurtenances @ front wall,facing macombs place,several areas are falling apart. masonry is bldg cracking & deteriorating from water & erosion. remedy: maintain exterior bldg
Aug 18, 2017 · Penalty $2,500
Resolve - Class - 2
Failure to comply with the commissioners order contained in summons/violation #35244350z issued on 04/19/17 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01.for failure to maintain
Jun 24, 2017 · Penalty $2,000
Resolve - Class - 1
Failure to maintain building in code compliant manner.defect noted:at roof level,drains clogged,severe accumulation of water approx 1 1/2 ft water leaking thru roof to 1st floor ceiling and floor the leaking
Apr 19, 2017 · Penalty $1,000
Resolve - Non-hazardous
Failure to have approved pa plans available for inspection remedy:provide approved pa plans at time of inspection
May 19, 1991 · Penalty $115
Resolve - Hazardous
Failure to have approved pa plans availbale for inspection. remedy:provide aproved pa plans at time of inspection
May 19, 1991
Resolve - Unknown
Failure to have approved pa plans available for inspection remedy provide approved pa plans
Dec 27, 1988
Resolve - Hazardous
Failure to have approved pa plans available for inspection remedy provide approved pa plans
Dec 27, 1988
Resolve
Complaints
- Unsanitary condition
Pests
Mar 27, 2026 · Apt 7B
Close - Unsanitary condition
Pests
Mar 10, 2026 · Apt 7B
Close - Door/window
Door
Mar 8, 2026 · Apt BLDG
Close - Unsanitary condition
Garbage/recycling storage
Mar 8, 2026 · Apt BLDG
Close - Elevator
Maintenance
Jan 28, 2026 · Apt 7D
Close - Unsanitary condition
Garbage/recycling storage
Jan 28, 2026 · Apt 7D
Close - Elevator
Maintenance
Jan 28, 2026 · Apt BLDG
Close - Heat/hot water
Entire building
Feb 15, 2025 · Apt BLDG
Close - Heat/hot water
Entire building
Nov 9, 2023 · Apt BLDG
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Elevator apartment building (D1)
- Year built
- 2021
- Floors
- 7
- Residential units
- 30
- Building area
- 25,664 ft²
- Lot area
- 5,473 ft²
- Zoning
- R7-2
- Community board
- 110
- Council district
- 9
- Block / lot
- 2040 / 23
- Assessed value
- $2,938,050
- Landmark / historic district
- No
HPD registration #145189, last renewed Jun 30, 2026.
Questions about 101 Macombs Place
Who owns 101 Macombs Place?
The owner of record in NYC Department of City Planning PLUTO data is 101 Macombs Place LLC.
Does 101 Macombs Place have violations?
Yes. NYC HPD has recorded 1 housing violations at this property.
Is 101 Macombs Place rent stabilized?
NYC Department of Finance tax bills listed 16 rent-stabilized units here in 2024 (about 53% of its 30 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.
When was 101 Macombs Place built?
City records list 2021 as the year it was built.
How many apartments are in 101 Macombs Place?
It has 30 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.