West 137 Street
Manhattan, NY 10037BBL 1-01734-0002Map
Owner of record: NYC Health And Hospitals Corporation
West 137 Street is a hospital / health built in 2022 in Manhattan, 10037. The owner of record is NYC Health And Hospitals Corporation. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 2
- ECB violations
- 35
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 2
- Construction other optional
Vio24-50411
Sep 30, 2024
Dob violation - dismissed - Construction other optional
Vio23-50229
Apr 21, 2023
Dob violation - dismissed
ECB violations · 35
- Class - 2
Exp3 observed vert members of sws close to curb line not in complianceto bc3307.6.4.4 stipulates vert members shall not be placed closer than 18 inches (455 mm) from the face of the curbline.hazard created stre
May 24, 2025 · Penalty $1,250
Resolve - Class - 2
At time of inspection observed active jobsite 2 suspended platforms store raised. upon inspecting drawings notice discrepancies. distance of out board on drawings is 5'6" they have 6'3". safety lines does not h
Feb 20, 2025
Resolve - Class - 2
At time of inspection observed active jobsite 2 suspended scaffolds raised and ready to use. upon requesting pre installation letter to rigging foreman it was not provided. also manufacture specification were n
Feb 20, 2025 · Penalty $1,250
Resolve - Class - 2
Failure to maintain/display onsite documents required by bc chapter 3310 story nb active site.observed khnemu harris was attached to personal fall arrest systems in use in interior elevator shaft.yellow straps
Sep 30, 2024 · Penalty $1,250
Resolve - Class - 1
At time of inspection observed pieces of glass on 4th floor and sidewalk shed from glass window that fell from 10th floor creating a hazardous conditions to the public and adjacent properties., safeguard public
Sep 20, 2024 · Penalty $5,000
Resolve - Class - 1
Bc 3301.6.1: manufacture specifications: in response to incident it was reported that worker while using band saw to cut copper pipe while inside scissor lift he was holding band saw above his head when it sli
Aug 6, 2024
Resolve - Class - 1
At time of inspection of department records observed contractor failed to comply with local law 78 and file report via web form for incident 43345 within 3 business days which occurred on 6-7-24 complaint # 166
Jul 12, 2024 · Penalty $5,000
Resolve - Class - 1
Observed a welder on 5th floor was performing overhead welding and the fire watch person standing on the floor slab as the sparks were fall, he failed to retain a portable fire extinguisher contrary with fc 260
May 28, 2024 · Penalty $1,250
Resolve - Class - 1
Observed a welder on 5th floor was performing overhead welding under the six floor decking slab and he was jumping the scissor lift top guardrails, creating an immediate hazardous and contrary with code 3301.1.
May 28, 2024 · Penalty $1,250
Resolve - Class - 2
Responding to incident that a worker caught left hand during north/west section of curtain wall installation at 7th floor level that was hoist from 4th floor. inspection reveals that no safety measure in place
May 1, 2024 · Penalty $625
Resolve
Show 25 more ↓
- Class - 1
Work does not conform to approved construction documents or approved amendments.as noted at the time of inspection based on complaint number#1666402 construction operation appear unsafe and collapsing observed
Apr 26, 2024 · Penalty $625
Resolve - Class - 1
Bc 3308.5 vertical netting: at time of inspection i observed vertical netting and toe boards inadequately maintained with zero cable not properly secured creating a hazardous condition to workers and persons do
Apr 26, 2024 · Penalty $5,000
Resolve - Class - 2
Bc2104.6(2014) and 2104.5(2022). failure to provide masonry construction bracing during construction atendance with t.m.s. 602/ac1530/asce to section 3.36. as noted at time of my inspection on active job site 1
Feb 1, 2024
Resolve - Class - 2
A worker had laceration on his head when a bucket of bolts and nuts gave way on 8th floor when it's handle came out of position and the bolts hit the worker on his head while working on 7th floor he walked to
Aug 18, 2023 · Penalty $5,000
Resolve - Class - 1
Permitholder failed to institute safety measures for persons engaged in construction. one of workers "rebar delivery" injured on site due to lack of safety measures were creating an immediate hazardous and in c
Jun 7, 2023
Resolve - Class - 1
Permitholder failed to provide temporary lighting for construction site on 2nd floor level and up, creating poor visibility for people entering the floors and causing hazardous of tripping and injuries. provide
Jun 7, 2023 · Penalty $2,500
Resolve - Class - 1
At a proposed 10 story building with steel erected up to 7th fl approx. 95ft in height. i noticed that standpipe wasn't in state of readiness with gauge marking 0.code requires when topmost working deck reaches
Jun 6, 2023 · Penalty $625
Resolve - Class - 1
At time of my inspection of a proposed 10 story building with structure steel erected up to 7th floor approx. 95ft in height. i noticed that no elevator hoist was in state of readiness as per section( 3303.12-3
Jun 6, 2023 · Penalty $625
Resolve - Class - 1
Time of inspection observed workers on supported scaffolding at exposure 2, unsafe scaffolding, decks not fully planked, no guard rails, no mud sills, no toe boards. stop all use of supported scaffolding on the
Apr 21, 2023
Resolve - Class - 1
At time of inspection, observed job site open currently on excavation phase. inadequate guardrail system on edge of excavation. missing toe boards, top rails or vertical post. depth of excavation approx. 15-20
Feb 6, 2023 · Penalty $5,000
Resolve - Class - 2
Upon inspection, observed open site currently on excavation phase. observed rebar on entire site unprotected without caps. no guardrails or caz on a middle section of site with a lot of unprotected rebars. obse
Feb 6, 2023 · Penalty $5,000
Resolve - Class - 1
At time of inspection it revealed worker while walking his left leg went into pile hole causing him to fall forward breaking his leg. inspection also revealed that area of operations was not maintained free fro
Dec 2, 2022 · Penalty $5,000
Resolve - Class - 2
Failure to submit an acceptable required cycle 9a report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control#913063.rem:submit acceptable required t
Dec 2, 2022 · Penalty $1,250
Resolve - Class - 2
Note: when worker running pump machine to collecting water from hole to container without hose pipe connect on it, discharge line create muddy water slush to pedestrian on sidewalk through netting over fence. f
Nov 30, 2022 · Penalty $5,000
Resolve - Class - 2
Soe connection details are contrary to approved drawings.
Sep 20, 2022
Resolve - Class - 1
28-105.12.8 site safety plan does not conform to existing site condition.note:at time of inspection of a demolition jobsite i obserfved construction workers entrance and exit access with means of 2 turnstile at
Apr 23, 2022 · Penalty $2,500
Resolve - Class - 1
Work not according to plans(supported scaffold)noted:at time of inspection of active demolition jobsite observed at all four exposures supported scaffold 70 ft high drawings show only walk through frames 5 ft w
Feb 25, 2022
Resolve - Class - 1
No designated site safety manager at jobsite. at time of inspection atactive demo site i observed active work in progress. upon request to ssm competent person stated that do not have one. bldg is 136 feet tall
Nov 29, 2021 · Penalty $10,000
Resolve - Class - 1
Work does not conform to site safety plan. at time of inspection at active 9 sty demo site w/active work in progress,i observed elevator shaft being used as debris chute w/openings not properly sealed also at 1
Nov 29, 2021 · Penalty $2,500
Resolve - Class - 1
Site safety orientation. at time of inspection at active demo site,i observed active work in progress. upon request to see site safety orientation log. none was provided. failure to properly inform & train work
Nov 29, 2021 · Penalty $5,000
Resolve - Class - 1
Housekeeping. at time of inspection at active demo site,i observed large amounts of construction debris piled high & scattered throughout jobsite causing a potential trip & fall hazard to workers & persons acce
Nov 29, 2021 · Penalty $2,500
Resolve - Class - 1
Sec. bc3303.7.4.2 sprinklers during demolition. at time of inspection at active demo site,i observed on numerous floors sprinkler system missing(braches)creating a hazard to workers & persons accessing these
Nov 29, 2021 · Penalty $10,000
Resolve - Class - 1
Sec. bc3301.2 failure to maintain safety mesures. at time of inspection at active demo site,i observed missing cover panels at circuit breaker boxes exposing electrical wires. failure to maintain cover panels
Nov 29, 2021
Resolve - Class - 1
Electrical work w/o permit. at time of inspection at active 9 sty demosite,i observed active work in progress. i observed electrical power supplied through site(temporary outlets-lights)review of dept records
Nov 29, 2021
Resolve - Class - 2
Failure to file an architect/engineer report certifying exit/directional signs are connected to emergency power source/storage battery equipment.rem:file architect/engineer report
Jan 27, 2010
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Hospital / health (I9)
- Year built
- 2022
- Floors
- 10
- Residential units
- —
- Building area
- 158,522 ft²
- Lot area
- 34,562 ft²
- Zoning
- R7-2
- Community board
- 110
- Council district
- 9
- Block / lot
- 1734 / 2
- Assessed value
- $2,461,500
- Landmark / historic district
- No
Questions about West 137 Street
Who owns West 137 Street?
The owner of record in NYC Department of City Planning PLUTO data is NYC Health And Hospitals Corporation.
Does West 137 Street have violations?
NYC HPD has no housing violations on record for this property.
Is West 137 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was West 137 Street built?
City records list 2022 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.