roofy

West 137 Street

Manhattan, NY 10037BBL 1-01734-0002Map

Owner of record: NYC Health And Hospitals Corporation

West 137 Street is a hospital / health built in 2022 in Manhattan, 10037. The owner of record is NYC Health And Hospitals Corporation. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
2
ECB violations
35
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 2

  • Construction other optional

    Vio24-50411

    Sep 30, 2024

    Dob violation - dismissed
  • Construction other optional

    Vio23-50229

    Apr 21, 2023

    Dob violation - dismissed

ECB violations · 35

  • Class - 2

    Exp3 observed vert members of sws close to curb line not in complianceto bc3307.6.4.4 stipulates vert members shall not be placed closer than 18 inches (455 mm) from the face of the curbline.hazard created stre

    May 24, 2025 · Penalty $1,250

    Resolve
  • Class - 2

    At time of inspection observed active jobsite 2 suspended platforms store raised. upon inspecting drawings notice discrepancies. distance of out board on drawings is 5'6" they have 6'3". safety lines does not h

    Feb 20, 2025

    Resolve
  • Class - 2

    At time of inspection observed active jobsite 2 suspended scaffolds raised and ready to use. upon requesting pre installation letter to rigging foreman it was not provided. also manufacture specification were n

    Feb 20, 2025 · Penalty $1,250

    Resolve
  • Class - 2

    Failure to maintain/display onsite documents required by bc chapter 3310 story nb active site.observed khnemu harris was attached to personal fall arrest systems in use in interior elevator shaft.yellow straps

    Sep 30, 2024 · Penalty $1,250

    Resolve
  • Class - 1

    At time of inspection observed pieces of glass on 4th floor and sidewalk shed from glass window that fell from 10th floor creating a hazardous conditions to the public and adjacent properties., safeguard public

    Sep 20, 2024 · Penalty $5,000

    Resolve
  • Class - 1

    Bc 3301.6.1: manufacture specifications: in response to incident it was reported that worker while using band saw to cut copper pipe while inside scissor lift he was holding band saw above his head when it sli

    Aug 6, 2024

    Resolve
  • Class - 1

    At time of inspection of department records observed contractor failed to comply with local law 78 and file report via web form for incident 43345 within 3 business days which occurred on 6-7-24 complaint # 166

    Jul 12, 2024 · Penalty $5,000

    Resolve
  • Class - 1

    Observed a welder on 5th floor was performing overhead welding and the fire watch person standing on the floor slab as the sparks were fall, he failed to retain a portable fire extinguisher contrary with fc 260

    May 28, 2024 · Penalty $1,250

    Resolve
  • Class - 1

    Observed a welder on 5th floor was performing overhead welding under the six floor decking slab and he was jumping the scissor lift top guardrails, creating an immediate hazardous and contrary with code 3301.1.

    May 28, 2024 · Penalty $1,250

    Resolve
  • Class - 2

    Responding to incident that a worker caught left hand during north/west section of curtain wall installation at 7th floor level that was hoist from 4th floor. inspection reveals that no safety measure in place

    May 1, 2024 · Penalty $625

    Resolve
Show 25 more ↓
  • Class - 1

    Work does not conform to approved construction documents or approved amendments.as noted at the time of inspection based on complaint number#1666402 construction operation appear unsafe and collapsing observed

    Apr 26, 2024 · Penalty $625

    Resolve
  • Class - 1

    Bc 3308.5 vertical netting: at time of inspection i observed vertical netting and toe boards inadequately maintained with zero cable not properly secured creating a hazardous condition to workers and persons do

    Apr 26, 2024 · Penalty $5,000

    Resolve
  • Class - 2

    Bc2104.6(2014) and 2104.5(2022). failure to provide masonry construction bracing during construction atendance with t.m.s. 602/ac1530/asce to section 3.36. as noted at time of my inspection on active job site 1

    Feb 1, 2024

    Resolve
  • Class - 2

    A worker had laceration on his head when a bucket of bolts and nuts gave way on 8th floor when it's handle came out of position and the bolts hit the worker on his head while working on 7th floor he walked to

    Aug 18, 2023 · Penalty $5,000

    Resolve
  • Class - 1

    Permitholder failed to institute safety measures for persons engaged in construction. one of workers "rebar delivery" injured on site due to lack of safety measures were creating an immediate hazardous and in c

    Jun 7, 2023

    Resolve
  • Class - 1

    Permitholder failed to provide temporary lighting for construction site on 2nd floor level and up, creating poor visibility for people entering the floors and causing hazardous of tripping and injuries. provide

    Jun 7, 2023 · Penalty $2,500

    Resolve
  • Class - 1

    At a proposed 10 story building with steel erected up to 7th fl approx. 95ft in height. i noticed that standpipe wasn't in state of readiness with gauge marking 0.code requires when topmost working deck reaches

    Jun 6, 2023 · Penalty $625

    Resolve
  • Class - 1

    At time of my inspection of a proposed 10 story building with structure steel erected up to 7th floor approx. 95ft in height. i noticed that no elevator hoist was in state of readiness as per section( 3303.12-3

    Jun 6, 2023 · Penalty $625

    Resolve
  • Class - 1

    Time of inspection observed workers on supported scaffolding at exposure 2, unsafe scaffolding, decks not fully planked, no guard rails, no mud sills, no toe boards. stop all use of supported scaffolding on the

    Apr 21, 2023

    Resolve
  • Class - 1

    At time of inspection, observed job site open currently on excavation phase. inadequate guardrail system on edge of excavation. missing toe boards, top rails or vertical post. depth of excavation approx. 15-20

    Feb 6, 2023 · Penalty $5,000

    Resolve
  • Class - 2

    Upon inspection, observed open site currently on excavation phase. observed rebar on entire site unprotected without caps. no guardrails or caz on a middle section of site with a lot of unprotected rebars. obse

    Feb 6, 2023 · Penalty $5,000

    Resolve
  • Class - 1

    At time of inspection it revealed worker while walking his left leg went into pile hole causing him to fall forward breaking his leg. inspection also revealed that area of operations was not maintained free fro

    Dec 2, 2022 · Penalty $5,000

    Resolve
  • Class - 2

    Failure to submit an acceptable required cycle 9a report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control#913063.rem:submit acceptable required t

    Dec 2, 2022 · Penalty $1,250

    Resolve
  • Class - 2

    Note: when worker running pump machine to collecting water from hole to container without hose pipe connect on it, discharge line create muddy water slush to pedestrian on sidewalk through netting over fence. f

    Nov 30, 2022 · Penalty $5,000

    Resolve
  • Class - 2

    Soe connection details are contrary to approved drawings.

    Sep 20, 2022

    Resolve
  • Class - 1

    28-105.12.8 site safety plan does not conform to existing site condition.note:at time of inspection of a demolition jobsite i obserfved construction workers entrance and exit access with means of 2 turnstile at

    Apr 23, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Work not according to plans(supported scaffold)noted:at time of inspection of active demolition jobsite observed at all four exposures supported scaffold 70 ft high drawings show only walk through frames 5 ft w

    Feb 25, 2022

    Resolve
  • Class - 1

    No designated site safety manager at jobsite. at time of inspection atactive demo site i observed active work in progress. upon request to ssm competent person stated that do not have one. bldg is 136 feet tall

    Nov 29, 2021 · Penalty $10,000

    Resolve
  • Class - 1

    Work does not conform to site safety plan. at time of inspection at active 9 sty demo site w/active work in progress,i observed elevator shaft being used as debris chute w/openings not properly sealed also at 1

    Nov 29, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    Site safety orientation. at time of inspection at active demo site,i observed active work in progress. upon request to see site safety orientation log. none was provided. failure to properly inform & train work

    Nov 29, 2021 · Penalty $5,000

    Resolve
  • Class - 1

    Housekeeping. at time of inspection at active demo site,i observed large amounts of construction debris piled high & scattered throughout jobsite causing a potential trip & fall hazard to workers & persons acce

    Nov 29, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    Sec. bc3303.7.4.2 sprinklers during demolition. at time of inspection at active demo site,i observed on numerous floors sprinkler system missing(braches)creating a hazard to workers & persons accessing these

    Nov 29, 2021 · Penalty $10,000

    Resolve
  • Class - 1

    Sec. bc3301.2 failure to maintain safety mesures. at time of inspection at active demo site,i observed missing cover panels at circuit breaker boxes exposing electrical wires. failure to maintain cover panels

    Nov 29, 2021

    Resolve
  • Class - 1

    Electrical work w/o permit. at time of inspection at active 9 sty demosite,i observed active work in progress. i observed electrical power supplied through site(temporary outlets-lights)review of dept records

    Nov 29, 2021

    Resolve
  • Class - 2

    Failure to file an architect/engineer report certifying exit/directional signs are connected to emergency power source/storage battery equipment.rem:file architect/engineer report

    Jan 27, 2010

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Hospital / health (I9)
Year built
2022
Floors
10
Residential units
—
Building area
158,522 ft²
Lot area
34,562 ft²
Zoning
R7-2
Community board
110
Council district
9
Block / lot
1734 / 2
Assessed value
$2,461,500
Landmark / historic district
No

Questions about West 137 Street

Who owns West 137 Street?

The owner of record in NYC Department of City Planning PLUTO data is NYC Health And Hospitals Corporation.

Does West 137 Street have violations?

NYC HPD has no housing violations on record for this property.

Is West 137 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was West 137 Street built?

City records list 2022 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.