411 East 114 Street
Manhattan, NY 10029BBL 1-01708-0007Map
Owner of record: 411 East 114 LLC
411 East 114 Street is a walk-up apartment building built in 1910 in Manhattan, 10029. It has 20 residential units across 5 floors. The owner of record is 411 East 114 LLC. HPD has recorded 573 housing violations here, most recently on October 5, 2026. 50 of the 50 most recent violations are still open. City tax records listed 14 rent-stabilized apartments here in 2024.
- HPD violations
- 573
- DOB violations
- 11
- ECB violations
- 7
- HPD complaints
- 596
What to know
Immediately hazardous issues among recent violations are still open.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.
Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 573
- BHazardous
Repair the broken or defective connection waste line at the sink in the kitchen located at apt 3, 1st story, 1st apartment from north at east
Oct 5, 2026 · Apt 3
Open — Nov sent out - CImmediately hazardous
M/d law abate the nuisance consisting of gas powered motorcycle being stored at boiler room
Oct 5, 2026
Open — Nov sent out - BHazardous
Properly repair with similar material the broken or defective fire retardant material at the west wall of the intermediate landing at public hall stairs, 5th story
Oct 5, 2026
Open — Nov sent out - ANon-hazardous
Repair the broken or defective gutter at east side of roof
Oct 5, 2026
Open — Nov sent out - BHazardous
Properly repair or replace the broken or defective latch set at bulkhead door
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective latch set at bulkhead
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
Properly repair with similar material the broken or defective vinyl floor tiles at intermediate landing at public hall stairs, 5th story
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
Properly repair with similar material the broken or defective fire retardant material at the east wall at public hall stairs, 5th story
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
Repair the roof so that it will not leak over the ceiling at public hall stairs, 5th story
Oct 5, 2026
Open — Nov sent out - ANon-hazardous
Paint with light colored paint to the satisfaction of this department the ceiling, west wall and east wall at public hall, 5th story
Oct 5, 2026
Open — Nov sent out
Show 40 more ↓
- CImmediately hazardous
Properly repair with similar material the broken or defective fire retardant material at the ceiling, west wall and east wall at public hall, 5th story
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
Repair the roof so that it will not leak over the ceiling at public hall, 5th story
Oct 5, 2026
Open — Nov sent out - ANon-hazardous
Paint with light colored paint to the satisfaction of this department the west wall at public hall, 4th story
Oct 5, 2026
Open — Nov sent out - BHazardous
Properly repair with similar material the broken or defective fire retardant material at west wall at public hall, 4th story
Oct 5, 2026
Open — Nov sent out - ANon-hazardous
Paint with light colored paint to the satisfaction of this department the ceiling and west wall at public hall, 2nd story
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
Properly repair with similar material the broken or defective fire retardant material at the ceiling, and west wall at public hall, 2nd story
Oct 5, 2026
Open — Nov sent out - BHazardous
Properly repair the source and abate the evidence of a water leak at the ceiling at public hall, 2nd story
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
Properly repair with similar material the broken or defective concrete subfloor at intermediate landing (sloping) at public hall stairs, 5th story
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
Properly repair with similar material the broken or defective concrete subfloor at intermediate landing (sloping) at public hall stairs, 4th story
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
Properly repair with similar material the broken or defective concrete subfloor at intermediate landing (sloping) at public hall stairs, 3rd story
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
Properly repair with similar material the broken or defective concrete subfloor at intermediate landing (sloping) at public hall stairs, 2nd story
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
Properly repair with similar material the broken or defective concrete subfloor at intermediate landing (sloping) at public hall stairs, 1st story
Oct 5, 2026
Open — Nov sent out - BHazardous
Refit door to basement (scraping) at public hall, 1st story
Oct 5, 2026
Open — Nov sent out - BHazardous
Properly repair or replace the broken or defective latch set at vestibule door at public hall, 1st story
Oct 5, 2026
Open — Nov sent out - ANon-hazardous
Paint with light colored paint to the satisfaction of this department the west wall of the intermediate landing at public hall stairs, 5th story
Oct 5, 2026
Open — Nov sent out - BHazardous
Properly repair with similar material the broken or defective stucco at the newel post of building front stairs
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
Properly repair with similar material the broken or defective stucco at the facade, building front
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective hinges at fire exit door to street from the cellar
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
M/d law abate the nuisance consisting of gas powered motorcycles and gas powered equipment throughout the cellar
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
M/d law abate the nuisance consisting of propane tanks being stored in the cellar
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
M/d law abate the nuisance consisting of gas powered motorcycles and bicycles being stored in the fuel (oil) tank room
Oct 5, 2026
Open — Nov sent out - CImmediately hazardous
Replace with new the missing hand rail at stairs to cellar from the 1st story public hall
Oct 5, 2026
Open — Nov sent out - BHazardous
Properly repair with similar material the broken or defective porcelain glaze at the bathtub in the bathroom located at apt 3, 1st story, 1st apartment from north at east
Oct 5, 2026 · Apt 3
Open — Nov sent out - BHazardous
Properly repair or replace the broken or defective electrical outlet at the south wall in the bathroom located at apt 3, 1st story, 1st apartment from north at east
Oct 5, 2026 · Apt 3
Open — Nov sent out - BHazardous
Replace the broken or defective wash basin in the bathroom located at apt 3, 1st story, 1st apartment from north at east
Oct 5, 2026 · Apt 3
Open — Nov sent out - BHazardous
Properly repair or replace the broken or defective light fixture at the south wall in the bathroom located at apt 3, 1st story, 1st apartment from north at east
Oct 5, 2026 · Apt 3
Open — Nov sent out - BHazardous
Properly repair the source and abate the evidence of a water leak at the ceiling in the bathroom located at apt 3, 1st story, 1st apartment from north at east
Oct 5, 2026 · Apt 3
Open — Nov sent out - BHazardous
Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling in the bathroom located at apt 3, 1st story, 1st apartment from north at east
Oct 5, 2026 · Apt 3
Open — Nov sent out - CImmediately hazardous
M/d law abate the nuisance consisting of washing machine with door intact at public hall, 5th story
Oct 5, 2026
Open — Nov sent out - BHazardous
Repair, replace or provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations defective (improper placement) in the entire apartment located at apt 20, 5th story
Oct 5, 2026 · Apt 20
Open — Nov sent out - BHazardous
Properly repair or replace the broken or defective inoperative bell and buzzer return system from building front to west wall box in the foyer located at apt 18, 5th story, 2nd apartment from north at east
Oct 5, 2026 · Apt 18
Open — Nov sent out - BHazardous
Repair the flushing apparatus and maintain same so as to flush effectively the water closet in the bathroom located at apt 18, 5th story, 2nd apartment from north at east
Oct 5, 2026 · Apt 18
Open — Nov sent out - BHazardous
Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling, west wall and east wall in the 2nd room from north located at apt 18, 5th story, 2nd apartment from north at east
Oct 5, 2026 · Apt 18
Open — Nov sent out - BHazardous
Repair, replace or provide an approved and operational carbon monoxide detecting device, installed in accordance with applicable law and rules defective (improper placement) in the entire apartment located at apt 20, 5th story
Oct 5, 2026 · Apt 20
Open — Nov sent out - CImmediately hazardous
Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling and west wall in the kitchen located at apt 18, 5th story, 2nd apartment from north at east
Oct 5, 2026 · Apt 18
Open — Nov sent out - CImmediately hazardous
Repair the roof so that it will not leak over the ceiling in the kitchen located at apt 18, 5th story, 2nd apartment from north at east
Oct 5, 2026 · Apt 18
Open — Nov sent out - CImmediately hazardous
Replace or repair the self-closing doors that is missing or defective door in the entrance located at apt 18, 5th story, 2nd apartment from north at east
Oct 5, 2026 · Apt 18
Open — Nov sent out - ANon-hazardous
§ 300 m/d law file plans and application and legalize the following alteration or restore to the legal condition existing prior to the making of said alteration consisting of walls erected with a frame and door enclosing the room in the 3rd room from north located at apt 19, 5th story, 1st apartment from north at east
Oct 5, 2026 · Apt 19
Open — Nov sent out - ANon-hazardous
Paint with light colored paint to the satisfaction of this department the wall and ceilings throughout in the entire apartment located at apt 18, 5th story, 2nd apartment from north at east
Oct 5, 2026 · Apt 18
Open — Nov sent out - BHazardous
Repair the leaky and/or defective faucets at the sink in the kitchen located at apt 19, 5th story, 1st apartment from north at east
Oct 5, 2026 · Apt 19
Open — Nov sent out
DOB building violations · 11
- Construction other optional
Requesting a structural stability report due to all stories, from the 1st-story intermediate landing throughout the public hallway leading to the bulkhead, all intermediate landings are sloping and sagging.
Oct 7, 2026
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Nov 8, 2019
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 24, 2018
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 29, 2015
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 29, 2015
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 29, 2015
Dob violation - active - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 10, 1997
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 18, 1994
Dob violation - dismissed
Show 1 more ↓
- Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 18, 1993
Dob violation - dismissed
ECB violations · 7
- Class - 1
Failure to maintain interior of building. observed at all stories, from the 1st-story intermediate landing throughout the public hallway leading to the bulkhead, all intermediate landings are sloping and saggin
Oct 7, 2026 · Penalty $2,500
Active - Class - 1
Work w/o a permit-work noted: at exterior cellar level removed existing window & created a new entrydoor. where the orignal door was closed opening w/cmu blocks. on the interior of premises installed sheetrock
Oct 18, 2017 · Penalty $1,600
Active - Class - 2
Failure to secure support raceways cable assemblies boxes cabinets fittings.electrical metalic tubing feeding electrical fixture in lobby not supported.rem:secure support per ec
Oct 18, 2017 · Penalty $800
Resolve - Class - 1
Failure to comply w/the commissioner's order contained in notice of violation #35127461z issued on 4/27/15. for work w/o a permit,at cellar level installed plumbing lines for 2pc bathroom & kitchen sink for 2
Jun 24, 2015 · Penalty $12,000
Active - Class - 1
Work w/o a permit noted: at cellar level 2 sro's with a shared 2pc bath and a shared kitchen w/hot plates,beds,computing refrigerators,and personal belongings have been created with seetrock walls w/o a permit
Apr 27, 2015 · Penalty $8,000
Active - Class - 1
Occupancy contrary to that allowed by the certificate of occupancy noted: as per dept records premises has no legal occupancy for the cellarexcept storage and utilities when there was 2 sros with a 2pc bath and
Apr 27, 2015 · Penalty $12,000
Active - Class - 1
Failure to maintain bldg in a code compliant manner,failure to providenumber of required means of egress for every floor per bc1018.1 and 27.366 noted: @ cellar level 2 sro's present w/o a proper means of egres
Apr 27, 2015 · Penalty $6,000
Active
Complaints
- Heat/hot water
Entire building
Oct 23, 2026 · Apt BLDG
Open - Plumbing
Basin/sink
Oct 20, 2026 · Apt 18
Open - Safety
Smoke detector
Jun 22, 2026 · Apt 19
Close - General
Cabinet
Jun 22, 2026 · Apt 18
Close - Unsanitary condition
Pests
Jun 22, 2026 · Apt 3
Close - Unsanitary condition
Pests
Jun 22, 2026 · Apt 3
Close - Safety
Smoke detector
Jun 22, 2026 · Apt 3
Close - Safety
Carbon monoxide detector
Jun 22, 2026 · Apt 3
Close - Plumbing
Basin/sink
Jun 22, 2026 · Apt 3
Close - Plumbing
Basin/sink
Jun 22, 2026 · Apt 3
Close
Show 40 more ↓
- Unsanitary condition
Mold
Jun 22, 2026 · Apt 3
Close - Unsanitary condition
Mold
Jun 22, 2026 · Apt 16
Close - Unsanitary condition
Mold
Jun 22, 2026 · Apt 16
Close - Unsanitary condition
Pests
Jun 22, 2026 · Apt 18
Close - Unsanitary condition
Pests
Jun 22, 2026 · Apt 18
Close - Safety
Fire escape
Jun 22, 2026 · Apt BLDG
Close - Door/window
Door
Jun 22, 2026 · Apt BLDG
Close - General
Bell/buzzer/intercom
Jun 22, 2026 · Apt BLDG
Close - General
Mailbox
Jun 22, 2026 · Apt BLDG
Close - Paint/plaster
Ceiling
Jun 22, 2026 · Apt BLDG
Close - Paint/plaster
Wall
Jun 22, 2026 · Apt BLDG
Close - Unsanitary condition
Garbage/recycling storage
Jun 22, 2026 · Apt BLDG
Close - Safety
Carbon monoxide detector
Jun 22, 2026 · Apt 19
Close - Door/window
Door
Jun 22, 2026 · Apt 18
Close - Unsanitary condition
Pests
Jun 22, 2026 · Apt 19
Close - Unsanitary condition
Pests
Jun 22, 2026 · Apt 19
Close - Door/window
Door
Jun 22, 2026 · Apt 19
Close - Paint/plaster
Ceiling
Jun 22, 2026 · Apt 18
Close - Paint/plaster
Wall
Jun 22, 2026 · Apt 18
Close - Unsanitary condition
Mold
Jun 22, 2026 · Apt 18
Close - Unsanitary condition
Pests
Jun 22, 2026 · Apt 16
Close - Heat/hot water
Entire building
Apr 18, 2026 · Apt BLDG
Close - Heat/hot water
Entire building
Mar 29, 2026 · Apt BLDG
Close - Heat/hot water
Entire building
Mar 27, 2026 · Apt APT16
Close - Heat/hot water
Entire building
Mar 25, 2026 · Apt BLDG
Close - Heat/hot water
Entire building
Mar 25, 2026 · Apt 18
Close - Electric
Wiring
Feb 1, 2026 · Apt 10
Close - Unsanitary condition
Mold
Feb 1, 2026 · Apt 10
Close - General
Ventilation system
Feb 1, 2026 · Apt 10
Close - General
Cabinet
Feb 1, 2026 · Apt 10
Close - Heat/hot water
Entire building
Jan 31, 2026 · Apt 16
Close - Heat/hot water
Entire building
Jan 31, 2026 · Apt BLDG
Close - Heat/hot water
Entire building
Jan 31, 2026 · Apt 16
Close - Electric
Wiring
Jan 21, 2026 · Apt 10
Close - Plumbing
Radiator
Jan 21, 2026 · Apt 10
Close - General
Ventilation system
Jan 21, 2026 · Apt 10
Close - Door/window
Window frame
Jan 21, 2026 · Apt 10
Close - Plumbing
Radiator
Jan 5, 2026 · Apt 10
Close - Unsanitary condition
Pests
Jan 5, 2026 · Apt 10
Close - Door/window
Window frame
Jan 5, 2026 · Apt 10
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Walk-up apartment building (C1)
- Year built
- 1910
- Floors
- 5
- Residential units
- 20
- Building area
- 12,770 ft²
- Lot area
- 3,313 ft²
- Zoning
- R7B
- Community board
- 111
- Council district
- 8
- Block / lot
- 1708 / 7
- Assessed value
- $751,950
- Landmark / historic district
- No
HPD registration #122314, last renewed Sep 9, 2025.
Questions about 411 East 114 Street
Who owns 411 East 114 Street?
The owner of record in NYC Department of City Planning PLUTO data is 411 East 114 LLC.
Does 411 East 114 Street have violations?
Yes. NYC HPD has recorded 573 housing violations at this property.
Is 411 East 114 Street rent stabilized?
NYC Department of Finance tax bills listed 14 rent-stabilized units here in 2024 (about 70% of its 20 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.
When was 411 East 114 Street built?
City records list 1910 as the year it was built.
How many apartments are in 411 East 114 Street?
It has 20 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.