roofy

1410 York Avenue

Manhattan, NY 10021BBL 1-01486-0049Map

Owner of record: Jacin Investors LLC

1410 York Avenue is an elevator apartment building built in 1960 in Manhattan, 10021. It has 53 residential units across 6 floors. The owner of record is Jacin Investors LLC. HPD has recorded 116 housing violations here, most recently on August 23, 2026. 22 of the 50 most recent violations are still open. City tax records listed 18 rent-stabilized apartments here in 2024.

HPD violations
116
DOB violations
59
ECB violations
40
HPD complaints
263

What to know

Concern
7 open Class C

Immediately hazardous issues among recent violations are still open.

Watch
Last violation Aug 23, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
18
About 34% of the building's 53 apartments

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 116

  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at all walls in the bathroom located at apt 5j, 5th story, 1st apartment from east at south

    Aug 23, 2026 · Apt 5J

    Open — Civ14 mailed
  • A

    Properly repair or replace the broken or defective bell buzzer intercom system from the building entrance door to the apartment wall panel at south wall in the foyer located at apt 3e, 3rd story, 1st apartment from south at west

    Aug 23, 2026 · Apt 3E

    Open — Nov sent out
  • B

    Properly repair with similar material the broken or defective hardwood floor in the kitchen located at apt 3e, 3rd story, 1st apartment from south at west

    Aug 23, 2026 · Apt 3E

    Open — Civ14 mailed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling, east and south walls in the bathroom located at apt 4b, 4th story, 3rd apartment from north at east

    Jun 2, 2026 · Apt 4B

    Closed — Violation dismissed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the bathroom located at apt 5b, 5th story, 3rd apartment from north at east

    Jun 2, 2026 · Apt 5B

    Closed — Violation dismissed
  • A

    Trace and repair the source and abate the visible mold condition... less than 10 sqft at ceiling in the bathroom located at apt 5b, 5th story, 3rd apartment from north at east

    Jun 2, 2026 · Apt 5B

    Closed — Violation closed
  • B

    Trace and repair the source and abate the visible mold condition... less than 10 sqft at ceiling in the bathroom located at apt 5b, 5th story, 3rd apartment from north at east original violation 18974316 issued 02-jun-26 has been upgraded to class b per administrative code 27-2017.3a(3)(a) or (b).

    Jun 2, 2026 · Apt 5B

    Open — Notice of issuance sent to tenant
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color at ceiling in the bathroom located at apt 5b, 5th story, 3rd apartment from west at north

    May 31, 2026 · Apt 5B

    Closed — Violation dismissed
  • C

    Replace or repair the self-closing doors that is missing or defective latch set in the entrance located at apt 5b, 5th story, 3rd apartment from west at north

    May 31, 2026 · Apt 5B

    Closed — Violation dismissed
  • B

    Properly repair or replace the broken or defective latch set at door in the entrance located at apt 5b, 5th story, 3rd apartment from west at north

    May 31, 2026 · Apt 5B

    Closed — Violation dismissed
Show 40 more ↓
  • B

    Repair the leaky and/or defective faucets at bathtub in the bathroom located at apt 5j, 5th story, 1st apartment from east at south

    Jul 8, 2025 · Apt 5J

    Closed — Violation dismissed
  • B

    Properly repair with similar material the broken or defective caulking around bathtub in the bathroom located at apt 5j, 5th story, 1st apartment from east at south

    Jul 8, 2025 · Apt 5J

    Closed — Violation dismissed
  • A

    Post sign on wall of entrance story bearing name, address including apartment number if any, and telephone number of superintendent, janitor or housekeeper. at public hall, 1st story

    Jul 8, 2025

    Closed — Violation dismissed
  • C

    Properly repair or replace the broken or defective inner glass pane at lower window sash at south wall in the kitchen located at apt 5j, 5th story, 1st apartment from east at south

    May 16, 2025 · Apt 5J

    Open — Nov certified late
  • B

    Properly repair or replace the broken or defective floor base cabinet at west wall in the kitchen located at apt 5j, 5th story, 1st apartment from east at south

    May 16, 2025 · Apt 5J

    Open — Nov sent out
  • B

    Properly repair or replace the broken or defective counter balance at lower window sash 1st window from north at east wall in the 2nd room from north located at apt 5j, 5th story, 1st apartment from east at south

    May 16, 2025 · Apt 5J

    Open — Nov sent out
  • B

    Properly repair or replace the broken or defective counter balance at lower window sash in 3rd window from north at east wall in the 2nd room from north located at apt 5j, 5th story, 1st apartment from east at south

    May 16, 2025 · Apt 5J

    Open — Nov sent out
  • C

    M/d law abate the nuisance consisting of hot water exceeding 130 degrees at all hot water fixtures in the entire apartment located at apt 3e, 3rd story, 1st apartment from south at west

    Feb 28, 2025 · Apt 3E

    Open — Nov sent out
  • B

    Properly repair or replace the broken or defective bell buzzer intercom system from the building entrance door to the panel at south wall in the foyer located at apt 3e, 3rd story, 1st apartment from south at west

    Feb 28, 2025 · Apt 3E

    Open — Nov sent out
  • B

    Repair or replace the carbon monoxide detecting device(s). defective in the entire apartment located at apt 3e, 3rd story, 1st apartment from south at west

    Feb 28, 2025 · Apt 3E

    Closed — Violation dismissed
  • C

    Replace or repair the self-closing doors that is missing or defective hinges in the entrance located at apt 3e, 3rd story, 1st apartment from south at west

    Feb 15, 2025 · Apt 3E

    Closed — Violation closed
  • B

    Repair or replace the carbon monoxide detecting device(s). missing in the entire apartment located at apt 3e, 3rd story, 1st apartment from south at west

    Feb 15, 2025 · Apt 3E

    Closed — Violation dismissed
  • B

    Replace with new the missing fuses box cover at west wall in the foyer located at apt 3e, 3rd story, 1st apartment from south at west

    Feb 15, 2025 · Apt 3E

    Open — Nov sent out
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color east wall in the bathroom located at apt 3e, 3rd story, 1st apartment from south at west

    Feb 15, 2025 · Apt 3E

    Closed — Violation dismissed
  • C

    Replace or repair the self-closing doors that is missing or defective latch set in the entrance located at apt 5g, 5th story, 2nd apartment from east at south

    Nov 14, 2024 · Apt 5G

    Closed — Violation closed
  • B

    Replace with new the missing glass pane lower window sash at east wall at public hall stairs, 3rd story

    Nov 14, 2024

    Closed — Violation dismissed
  • B

    Properly repair or replace the broken or defective intercom/buzzer system from building entrance to panel at south wall in the private hallway located at apt 5g, 5th story, 2nd apartment from east at south

    Nov 14, 2024 · Apt 5G

    Closed — Violation dismissed
  • C

    Replace or repair the self-closing doors that is missing or defective latchset at compactor closet door at public hall, 5th story

    Sep 1, 2024

    Open — Nov certified late
  • C

    Replace or repair the self-closing doors that is missing or defective hinges in the entrance located at apt 5j, 5th story, 1st apartment from east at south

    Aug 17, 2024 · Apt 5J

    Closed — Violation dismissed
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 5j, 5th story, 1st apartment from east at south

    Aug 17, 2024 · Apt 5J

    Open — Nov certified late
  • C

    Abate the infestation consisting of mice in the entire apartment located at apt 3h, 3rd story, 1st apartment from south at west

    Sep 20, 2023 · Apt 3H

    Open — Notice of issuance sent to tenant
  • C

    Replace or repair the self-closing doors that is missing or defective hinges in the entrance located at apt 3h, 3rd story, 1st apartment from south at west

    Sep 20, 2023 · Apt 3H

    Closed — Violation dismissed
  • A

    Paint metal in accordance with dept. regulation at radiator at north wall at 2nd story landing at public hall, 2nd story

    Sep 6, 2023

    Closed — Violation dismissed
  • A

    § 329, m/d law and dept. rules and regs. provide a completed certificate of inspection visits in a proper frame at or near mailboxes, bottom edge of frame between 48-62 inches above floor missing frame at public hall, 1st story

    Sep 6, 2023

    Open — Nov sent out
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color the ceiling in the bathroom located at apt 5e, 5th story, 1st apartment from south at west

    Aug 30, 2023 · Apt 5E

    Closed — Violation dismissed
  • C

    Properly repair with similar material the broken or defective fire retardant material south wall at bulkhead , 6th story

    Aug 28, 2023

    Closed — Violation dismissed
  • A

    Paint with light colored paint to the satisfaction of this department south wall at bulkhead , 6th story

    Aug 28, 2023

    Closed — Violation dismissed
  • C

    Replace or repair the self-closing doors that is missing or defective door at bulkhead at public hall stairs, 6th story

    Aug 5, 2023

    Closed — Violation closed
  • C

    Replace or repair the self-closing doors that is missing or defective latchset to door at compactor closet, 3rd story

    Aug 5, 2023

    Closed — Violation closed
  • C

    Replace or repair the self-closing doors that is missing or defective latchset to door at compactor closet, 2nd story

    Aug 5, 2023

    Closed — Violation closed
  • B

    Properly repair or replace the broken or defective i glass pane at palladian window at public hall stairs, 2nd story

    Aug 5, 2023

    Closed — Violation dismissed
  • B

    Properly repair or replace the broken or defective window lock at south wall in the 2nd room from east located at apt 1h, 1st story, 1st apartment from south at west

    May 14, 2023 · Apt 1H

    Open — Nov sent out
  • B

    Properly repair with similar material the broken or defective sagging wood floor in the 1st room from east located at apt 1h, 1st story, 1st apartment from south at west

    May 14, 2023 · Apt 1H

    Open — Nov sent out
  • B

    Provide dwelling with a janitor or responsible person or janitorial service.

    May 14, 2023

    Open — Nov sent out
  • A

    § 329, m/d law and dept. rules and regs. provide a completed certificate of inspection visits in a proper frame at or near mailboxes, bottom edge of frame between 48-62 inches above floor at public hall, 1st story

    Jun 4, 2022

    Closed — Violation dismissed
  • B

    Remove all obstructions and repair all defects in wastelines at wash basin and shower stall in the bathroom located at apt 2g, 2nd story, 2nd apartment from east at south

    Jun 4, 2022 · Apt 2G

    Open — Nov certified late
  • C

    Provide ready access to buildings heating system door leading to boiler room locked at boiler room, 1st story

    Jun 4, 2022

    Open — Nov sent out
  • C

    Provide hot water at all hot water fixtures in the entire apartment located at apt 2g, 2nd story, 2nd apartment from east at south

    Jun 4, 2022 · Apt 2G

    Open — Nov certified late
  • A

    Post sign on wall of entrance story bearing name, address including apartment number if any, and telephone number of superintendent, janitor or housekeeper. at public hall, 1st story

    Jun 4, 2022

    Closed — Violation dismissed
  • B

    Provide dwelling with a janitor or responsible person or janitorial service.

    Jun 4, 2022

    Open — Nov sent out

DOB building violations · 59

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 11, 2024

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 16, 2024

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 4, 2023

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 4, 2023

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 4, 2023

    Dob violation - active
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2022)

    Apr 22, 2023

    Dob violation - dismissed
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2021)

    Aug 21, 2022

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 5, 2022

    Dob violation - active
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2020)

    Jun 20, 2021

    Dob violation - dismissed
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2019)

    Jun 29, 2020

    Dob violation - dismissed
Show 40 more ↓
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 19, 2019

    Dob violation - resolved
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - active
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2018)

    Mar 18, 2019

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2016 inspection report

    Apr 6, 2018

    Dob violation - active
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2017)

    Mar 27, 2018

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 27, 2017

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 23, 2017

    Dob violation - resolved
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 in 2016

    Feb 16, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 2, 2016

    Dob violation - active
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Jun 2, 2016

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 18, 2015

    Dob violation - resolved
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 2, 2015

    Dob violation - active
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2015

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 16, 2014

    Dob violation - resolved
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 1, 2014

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 13, 2013

    Dob violation - resolved
  • No report and / or late filing (facade) facade required

    Failed to file fisp cycle 7a technical report by 02/21/2012

    Jan 31, 2013

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Oct 11, 2012

    Dob violation - resolved
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Jan 1, 2012

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 10, 2011

    Dob violation - resolved
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 13, 2011

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Dec 2, 2010

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Mar 24, 2010

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 10, 2009

    Dob violation - resolved
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Feb 27, 2009

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 14, 2008

    Dob violation - resolved
  • Facade facade optional

    Ll1198-local law 11/98 - facade facade optional

    Nov 30, 2007

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 20, 2007

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 16, 2005

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 6, 2004

    Dob violation - resolved
  • Elevator elevatorrequired

    1p20623

    Jul 22, 2002

    Dob violation - resolved
  • Elevator elevatorrequired

    1p20623

    Aug 11, 2000

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 7, 2000

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Construction other optional

    C-construction other optional

    Feb 9, 1998

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed

ECB violations · 40

  • Class - 2

    2/x/10 out side comm inoperative repair,100/l/10 camera in side elevator is not working defective repair.

    Apr 1, 2026 · Penalty $310

    Active
  • Class - 2

    Vf. hoist machine brake maintenance tag expired provide, car door misalignment , adjust. hoist way door misalignment adjust.

    Aug 16, 2024 · Penalty $625

    Resolve
  • Class - 1

    Cease use items: door lock monitoring not installed as mandated by 3.10.12 of appendix k3 of the nycbc. this safety device ensures passenger safety. door zone restrictor not working properly. this safety device

    Nov 28, 2023 · Penalty $1,250

    Active
  • Class - 1

    Class 1: door restrictor missing provide restrictor. door lock monitoring missing from this controller. install as mandated by 3.10.12 of appendix k3 of the 2014 of nycbc. this is a reoccuring condition which p

    Aug 18, 2023 · Penalty $3,125

    Active
  • Class - 1

    8:v:1; car saddle to hall saddle not level needs to be adjusted. 58:y:10; machine gearbox leaking oil, needs to be repaired. 100:m:7; door lock monitoring missing, needs to installed. 100:m:7; door zone restric

    Jun 13, 2023 · Penalty $6,250

    Active
  • Class - 1

    6/m/7 car door restrictor missing provide,8/v/1 car floor to landing sill not level adjust, no door lock monitoring installed in this controller as mandated by 3.10.12 of appendix k3 of the 2014 nycbc. this is

    May 3, 2023 · Penalty $3,125

    Resolve
  • Class - 1

    No door lock monitoring installed in this controller as mandated by 3.10.12 of appendix k3 of the 2014 nycbc. this is a controller feature which ensures passenger safety. remedy; file application, install dlm a

    Jun 30, 2022 · Penalty $3,125

    Resolve
  • Class - 1

    No door lock monitoring installed in this controller as mandated by 3.10.12 of appendix k3 of the 2014 nycbc. this is a controller feature which ensures passenger safety. remedy; file application, install dlm a

    Mar 29, 2022 · Penalty $3,125

    Resolve
  • Class - 1

    No door lock monitoring installed in this controller as per 3.10.12 of appendix k3 of the 2014 nycbc. remedy; install dlm and perform and file test with nycdob.

    Sep 28, 2021 · Penalty $6,250

    Active
  • Class - 2

    2x10,1l10,8v1. 2x10-outside comm inoperative repair; 1l10-emergency stop switch bell does not ring when activaed; 8v1-car floor to landingsill not level adjust.

    Mar 15, 2018 · Penalty $625

    Resolve
Show 30 more ↓
  • Class - 2

    11b07,39o02,29d06,10d06,61b07,70z09,98b07. 11b-comply with section 8.1 basement floor; 29d-door operator cover; 61b-unable to open provide 98b-provide info on tag.

    Jul 26, 2017 · Penalty $500

    Resolve
  • Class - 2

    40m07,100p07,39o02.40m01 provide machine room keys.100p07 provide access to basement.39o02 clean car top

    Jul 21, 2017 · Penalty $500

    Resolve
  • Class - 1

    05x10, 70o02 5)car door inoperative not closing 10)repair the only elevator in building out of service.the device is found to be inoperative creating a hazardous condition per rcny11 02)restore to service

    May 19, 2017 · Penalty $1,000

    Resolve
  • Class - 2

    32h1;75k10;70o02:(32)car shoes(h)worn(1)adjust(75)buffer-car(k)rusted(10)repair(70)pit(o)dirty(02)clean

    Apr 7, 2017 · Penalty $2,500

    Resolve
  • Class - 2

    98b15,75l10. 5 year test tag date cannot be read, car buffer in pit has been dislodged from its base.

    Feb 22, 2017 · Penalty $1,250

    Resolve
  • Class - 2

    8v1,5j1,10h11,16j1,29j1,56y2,56y13,70z9. 8v1-car floor to landing sill not level adjust; 5j1-car door misaligned adjust; 10h11,car door gibs worn replace; 16j1-hoistway door misaligned adjust; 29j1-door operat

    Jan 27, 2017

    Resolve
  • Class - 2

    8v10,70z4. (8v)car floor to st landing not leveling repair. ins off floor. (70z)water leak pit patch, 1-car in bldg.

    Jan 11, 2017

    Resolve
  • Class - 2

    40i10,21b07,39o02,29q03,39q03,08v01,75d06. 40-skylight window broken; 21-34,35 jumped need to know where lock wieres have been relocated or repair according to print; 39o-clean car top; 29-door operates unguard

    Oct 4, 2016 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to maintain bldg. noted: @ front of bldg above main entrance. found masonry sections removed/ missing section approx 21ft x 14ft. rem: repair defects & maintain bldg.

    Sep 21, 2016 · Penalty $500

    Resolve
  • Class - 2

    Work w/out a permit. noted: @ front of bldg near main entrance found new connections of electrical bx cables for wall sconces installed w/out a permit. @ approx 3:25pm, 9/21/16 bis shows no active electrical pe

    Sep 21, 2016 · Penalty $800

    Active
  • Class - 2

    02m07,08v01,10h11,17h11,40p16. alarm system missing provide, car floorto landing sill not level adjust,car door gibs worn replace,landing door gibs worn replace,machine room no means of access provide means o

    Jun 14, 2016

    Resolve
  • Class - 2

    59u15,68b07,35m11,29q03 no tag stating date of brake maintenance, no entry of date of brake maintennace in log, electrical box covers are missing on top of car, door operator cover is missing.

    Apr 6, 2016 · Penalty $500

    Resolve
  • Class - 2

    05-i-10,05-m-07,39-m-07,56-y-13,40-i-10,98-b-07,68-b-07,30-i-10,77-b-10,21-b-07,18-m-07:05-i-10-car door sight glass damaged repair.05-m-07-car door zone lock missing provide.39-m-07-car door operator cover mis

    Dec 21, 2015 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to file an acceptable cycle 7 technical report in compliance with code provisions: periodic inspection of exterior walls & appurtenances as required by article 28-302 & the dept of bldgs rules & regulat

    Apr 28, 2014

    Resolve
  • Class - 1

    Fail to comply w.comm order. respondent failed to correct conditions cited in 34870696h fail to maintain ac window units not properly installed. unit on 3rd fl on york ave & e 75 st. supported by wood blocking

    Oct 7, 2010 · Penalty $2,400

    Resolve
  • Class - 1

    Failure to maintain exterior bldg wall(s) or appurtenances. noted: ac window units at 3rd fflr on york ave side and on east 75 st are being supported by wood blocks. remedy: make area safe! remove wood blocks!

    Aug 23, 2010 · Penalty $1,000

    Resolve
  • Class - 1

    Failure to maintain exterior of bldg or appurtenances.window ac unit on 4th fl on east 75 st & on york ave are supported by wood blocking causing a hazardous cond.rem:make area safe install ac units w/metal bra

    Apr 24, 2010 · Penalty $1,000

    Resolve
  • Class - 2

    B254.28a.50.50 removed cap on chimney

    Oct 27, 2009 · Penalty $500

    Resolve
  • Class - 2

    10h11,23m07,40o02,08v10,59m11.10h11-car door gibs are worn,replace gibbs.23m11-replace missing 4fl hall button.40o02-clean machine room.08v10-replace floor stops.59m11-replace cover for machine brake.

    Mar 20, 2009

    Resolve
  • Class - 2

    Failure to submit an acceptable sixth round technical report in compliance w/ code provisions periodic insp of exterior walls and appurtenances as required by article 28.302 & the dob rules and regulations rem:

    Dec 19, 2008

    Resolve
  • Class - 2

    08y10,15i11,23q03,59b10,98bb05,56y10. 08v10-car floor to landing sill not level,repair.15i11-certificate frame in elevator damaged,replace.23o03-4fl hall station plate unguarded installed guard.59b10-machine

    Dec 10, 2008

    Resolve
  • Class - 1

    Failure to maintain exterior of building 24" metal chimney roof extension attached to (506 e 75 st) is missing previous metal chimney has rusted away. remedy: replace metal chimney.

    Sep 5, 2008

    Resolve
  • Hazardous

    B4b,16,51,51a,50a,b,c,d,e.51-chimney on roof ia apart.51a-soot on boiler needs boiler cleaning.50-missing blow down piping in safety valve.50a-cold water relief is pluged off/no good.50b-water lines not support

    Mar 27, 2008 · Penalty $400

    Active
  • Non-hazardous

    Failure to maintain bldg. defect noted: the 24" dir metal chimney extension attached to the adjacent bldg wall 506 e 75 st. from 7th fl. level to the roof level. (approx 40') is deteriorated, rusted & hanging

    Mar 27, 2008 · Penalty $800

    Resolve
  • Non-hazardous

    Failure to maintain bldg-defect:metal chimney corroded at base of top stack in need of repair.remedy:repair and or replace top stack of metal chimney foundation.

    Mar 29, 2005 · Penalty $180

    Resolve
  • Non-hazardous

    40h10-46h10-08v01

    Mar 12, 2001

    Resolve
  • Non-hazardous

    Occupancy contrary to that allowed by building department record. side yard illegally being use as parking for 2 or more cars. remedy: discontinue illegal use forthwith.

    Feb 27, 1998

    Resolve
  • Non-hazardous

    30o55m56m57o50y40e36w 30-clean hoistway 55, provide pit light 56 provide pit steps 57-clean pit, governor is noisy, 36-provide test on machine room door.

    Dec 19, 1997

    Resolve
  • Non-hazardous

    02i,02l,37l,08v.

    Nov 8, 1996 · Penalty $100

    Resolve
  • Non-hazardous

    75t.

    Sep 22, 1994

    Resolve

Complaints

  • Water leak

    Heavy flow

    Aug 4, 2026 · Apt 5J

    Close
  • Unsanitary condition

    Pests

    Jul 19, 2026 · Apt 3E

    Close
  • Flooring/stairs

    Floor

    Jul 19, 2026 · Apt 3E

    Close
  • Paint/plaster

    Ceiling

    Jul 19, 2026 · Apt 3E

    Close
  • Unsanitary condition

    Pests

    Jul 14, 2026 · Apt 3E

    Close
  • Unsanitary condition

    Pests

    Jul 14, 2026 · Apt 3E

    Close
  • Unsanitary condition

    Mold

    May 31, 2026 · Apt 4B

    Close
  • Paint/plaster

    Ceiling

    May 31, 2026 · Apt 5B

    Close
  • Water leak

    Damp spot

    May 31, 2026 · Apt 5B

    Close
  • Paint/plaster

    Ceiling

    May 28, 2026 · Apt 5B

    Close
Show 40 more ↓
  • Unsanitary condition

    Mold

    May 28, 2026 · Apt 5B

    Close
  • Paint/plaster

    Ceiling

    May 28, 2026 · Apt 4B

    Close
  • Unsanitary condition

    Mold

    May 28, 2026 · Apt 4B

    Close
  • Water leak

    Slow leak

    May 23, 2026 · Apt 4B

    Close
  • Appliance

    Electric/gas range

    Apr 15, 2026 · Apt 2H

    Close
  • Unsanitary condition

    Pests

    Apr 15, 2026 · Apt 2H

    Close
  • Unsanitary condition

    Pests

    Apr 15, 2026 · Apt 2H

    Close
  • Door/window

    Window frame

    Apr 15, 2026 · Apt 2H

    Close
  • Safety

    Carbon monoxide detector

    Apr 15, 2026 · Apt 2H

    Close
  • Heat/hot water

    Entire building

    Feb 3, 2026 · Apt BLDG

    Close
  • Unsanitary condition

    Pests

    Jan 14, 2026 · Apt 3E

    Close
  • Plumbing

    Radiator

    Jan 14, 2026 · Apt 5J

    Close
  • Unsanitary condition

    Pests

    Jan 14, 2026 · Apt 5J

    Close
  • General

    Cabinet

    Jan 14, 2026 · Apt 5J

    Close
  • Water leak

    Damp spot

    Dec 29, 2025 · Apt 5J

    Close
  • Unsanitary condition

    Mold

    Dec 29, 2025 · Apt 5J

    Close
  • Unsanitary condition

    Pests

    Dec 29, 2025 · Apt 5J

    Close
  • General

    Cabinet

    Dec 29, 2025 · Apt 5J

    Close
  • Elevator

    Maintenance

    Sep 28, 2025 · Apt BLDG

    Close
  • Plumbing

    Bathtub/shower

    Sep 2, 2025 · Apt 5J

    Close
  • Paint/plaster

    Ceiling

    Jun 27, 2025 · Apt 2J

    Close
  • Water leak

    Damp spot

    Jun 27, 2025 · Apt 2J

    Close
  • Unsanitary condition

    Mold

    Jun 27, 2025 · Apt 2J

    Close
  • General

    Janitor/super

    Jun 12, 2025 · Apt 5J

    Close
  • Door/window

    Window pane

    May 23, 2025 · Apt 5J

    Close
  • Door/window

    Window frame

    May 14, 2025 · Apt 5J

    Close
  • Safety

    Fire escape

    May 14, 2025 · Apt 5J

    Close
  • Door/window

    Window frame

    May 14, 2025 · Apt 5J

    Close
  • Door/window

    Window pane

    May 14, 2025 · Apt 5J

    Close
  • Heat/hot water

    Apartment only

    May 14, 2025 · Apt 5J

    Close
  • Heat/hot water

    Entire building

    Mar 10, 2025 · Apt BLDG

    Close
  • Paint/plaster

    Wall

    Feb 27, 2025 · Apt 3E

    Close
  • Unsanitary condition

    Pests

    Feb 27, 2025 · Apt 3E

    Close
  • Flooring/stairs

    Floor

    Feb 27, 2025 · Apt 3E

    Close
  • Door/window

    Window frame

    Feb 27, 2025 · Apt 3E

    Close
  • General

    Bell/buzzer/intercom

    Feb 27, 2025 · Apt 3E

    Close
  • Plumbing

    Water supply

    Feb 27, 2025 · Apt 3E

    Close
  • Unsanitary condition

    Mold

    Feb 27, 2025 · Apt 3E

    Close
  • General

    Bell/buzzer/intercom

    Feb 6, 2025 · Apt 5G

    Close
  • Flooring/stairs

    Floor

    Feb 2, 2025 · Apt 3E

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D1)
Year built
1960
Floors
6
Residential units
53
Building area
45,148 ft²
Lot area
10,012 ft²
Zoning
R10
Community board
108
Council district
5
Block / lot
1486 / 49
Assessed value
$2,897,550
Landmark / historic district
No

HPD registration #102186, last renewed Oct 20, 2025.

Questions about 1410 York Avenue

Who owns 1410 York Avenue?

The owner of record in NYC Department of City Planning PLUTO data is Jacin Investors LLC.

Does 1410 York Avenue have violations?

Yes. NYC HPD has recorded 116 housing violations at this property.

Is 1410 York Avenue rent stabilized?

NYC Department of Finance tax bills listed 18 rent-stabilized units here in 2024 (about 34% of its 53 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 1410 York Avenue built?

City records list 1960 as the year it was built.

How many apartments are in 1410 York Avenue?

It has 53 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.