235 East 45 Street
Manhattan, NY 10017BBL 1-01319-0016Map
Owner of record: Hearst Communications
235 East 45 Street is an office building built in 1929 in Manhattan, 10017. The owner of record is Hearst Communications. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 77
- ECB violations
- 16
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 77
- Construction other optional
Emergency work order due to leaning steel fency at exposure #1 (south elev.) remedy: immediately take & provide safety measures to secure/ protect the public & install public protection at exp #1 (south elev.) make immediate repairs under supervision of licensed professional also remove/secure the loose fence
Nov 18, 2024
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 10, 2024
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Feb 21, 2024
Dob violation - active - Construction other optional
Emergency work order(3 levels(cellar l-1 @l-2 and above gl l-3) spalling concrete/expose rebar, crack beam ans slab @every flr@several loc.causing immed haz to vehicular&pedestrian traffic,req.immed safety measures.remedy:retain a nys reg.design prof.to direct&superv.immed install safety measures reports to [email protected]
Dec 19, 2023
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 6, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 6, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 6, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 4, 2020
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 4, 2020
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 4, 2020
Dob violation - resolved
Show 40 more ↓
- Elevator elevatorrequired
E-elevator elevatorrequired
May 4, 2020
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 4, 2020
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 4, 2020
Dob violation - resolved - Sprinkler none
Failed to file final sprinkler report by july 1, 2019
Sep 3, 2019
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 1, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 1, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 1, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 1, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 1, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 1, 2019
Dob violation - resolved - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Feb 16, 2019
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Jun 2, 2016
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 18, 2015
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 17, 2014
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 17, 2014
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 16, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 16, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 16, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 16, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 16, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 16, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 28, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 28, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 28, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 28, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 28, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 28, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 14, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 14, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 14, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 14, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 14, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 17, 2010
Dob violation - resolved
ECB violations · 16
- Class - 2
At time of inspection observed a supported scaffold at corner of exp. 3 and 4. supported scaffold no maintain in code complying manner. unsecured debris and materials store on scaffold. planks are not tie down
May 8, 2025 · Penalty $2,500
Resolve - Class - 1
Failure to maintain exterior building facade and appurtenances.note:attime of inspection observed at exposure#1(south elevation)leaning steel fence.rem:maintain exterior building facade and appurtenances provid
Nov 18, 2024 · Penalty $2,500
Resolve - Class - 1
Unlawful acts.failure to comply with commissioner's order.note:at the time of inspection observed respondent failure to comply with previousviolation#35675590m,35675591y dated 12/19/2023 and dob violation#12192
Mar 14, 2024 · Penalty $2,500
Active - Class - 1
28-323.1 failure to maintain parking structure in safe condition: note:-observed on an occupied parking structure consisting of 3 level(cellar below gl-l-1, at grade l-2, and above gl-3), spalling concrete/expo
Dec 19, 2023 · Penalty $2,500
Active - Class - 1
28-323.8 and rcvny-103-13(5) failure to secure public saftety and/or make the buildings structure and appurtenances conform to the previous of the admin code after unsafe notification filled-u.n.p.s.-m0002639 d
Dec 19, 2023 · Penalty $2,500
Active - Class - 2
27-929.1 failure to complete the installation of a full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional in an office building 100 feet or more in he
Mar 30, 2021 · Penalty $3,125
Resolve - Class - 2
A.c. 27.929.1 failure to complete teh installation of a full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional by july 1,2019,in an office building 10
Jul 13, 2020 · Penalty $1,562
Resolve - Class - 2
Ac279291-failure to complete the installation of a full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional by july 1,2019,in an office building 100 fee
Nov 15, 2019 · Penalty $1,250
Resolve - Class - 2
Failure to file annual certification that cooling tower 1000001651 hasbeen inspected,tested,and disinfected,and that a maintenance plan has been developed and implemented,by november,1,2016.rem:file annual cert
Jun 20, 2017 · Penalty $1,000
Resolve - Class - 2
Failure to file annual certification that cooling tower 1000001635 hasbeen inspected,tested,and disinfected,and that a maintenance plan has been developed and implemented,by november,1,2016.rem:file annual cert
Jun 20, 2017 · Penalty $2,030
Resolve
Show 6 more ↓
- Class - 2
Failure to file annual certification that cooling tower 1000001650 hasbeen inspected,tested,and disinfected,and that a maintenance plan has been developed and implemented,by november,1,2016.rem:file annual cert
Jun 20, 2017 · Penalty $1,000
Resolve - Class - 3
Sec. 27-132. failure to provide required tenant protection plan in a bldg under construction while being occupied. at time of inspection notenant protection plan @ site. remedy: comply w/notice. provide tenant
Apr 10, 2012
Resolve - Class - 1
Failure to file affidavits and/or comply with other requirements sete forth for photoluminescent exit path marking.remedy:compy with requirements of reference standards (rs)6-1
Sep 25, 2008
Resolve - Non-hazardous
Failure to file an amended sixth round report acceptable to this department indicating correction of unsafe conditions described in initial local law 11/98 report. remedy: file an amended report following remed
Apr 18, 2008 · Penalty $700
Resolve - Hazardous
'ocal law report filed as"unsafe",unsafe condition exists & no measures taken to secure safety of public as per 27-129(d) & 1 rcny 32-03(b)(5)(i).remedy:provide safety measures as per bldg code,file report "as
Jan 16, 2008
Resolve - Non-hazardous
66d10 66-repair hardware on pit door door mist be kept lock
Feb 10, 2004 · Penalty $180
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Office building (O3)
- Year built
- 1929
- Floors
- 16
- Residential units
- —
- Building area
- 200,311 ft²
- Lot area
- 15,062 ft²
- Zoning
- C6-4
- Community board
- 106
- Council district
- 4
- Block / lot
- 1319 / 16
- Assessed value
- $33,460,200
- Landmark / historic district
- No
Questions about 235 East 45 Street
Who owns 235 East 45 Street?
The owner of record in NYC Department of City Planning PLUTO data is Hearst Communications.
Does 235 East 45 Street have violations?
NYC HPD has no housing violations on record for this property.
Is 235 East 45 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 235 East 45 Street built?
City records list 1929 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.