roofy

411 West 55 Street

Manhattan, NY 10019BBL 1-01065-0025Map

Owner of record: 411 West 55 LLC

411 West 55 Street is a garage / gas station built in 1911 in Manhattan, 10019. The owner of record is 411 West 55 LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
20
ECB violations
25
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 20

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Feb 21, 2024

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 24, 2024

    Dob violation - dismissed
  • Construction other optional

    Emergency work order.note:observ.fr.1st flr to 6th flr deteriorating concrete slab&beam with expose rebar&spalling concrete.causing immed haz.to traffic.remedy:owner to retain a nys reg.design professional to direct&superv.immed.install.of adeq.safety measures such as stabilzing members or prov.sheding&barricades rdp to prov.daily prog report/also

    Nov 24, 2023

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 11, 2016

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 6, 2014

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 8, 2013

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 5, 2012

    Dob violation - resolved
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Feb 22, 2012

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Feb 22, 2012

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 6, 2011

    Dob violation - resolved
Show 10 more ↓
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 11, 2010

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 22, 2009

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Mar 27, 2007

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 19, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 27, 2005

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 26, 2003

    Dob violation - resolved
  • Elevator elevatorrequired

    1f3644

    Nov 5, 2002

    Dob violation - resolved
  • Elevator elevatorrequired

    1f3644

    Oct 23, 2001

    Dob violation - resolved
  • Elevator elevatorrequired

    1f3644

    Jun 20, 2000

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 1, 1989

    Dob violation - resolved

ECB violations · 25

  • Class - 1

    28-323.8 and rcny 103-13(5). failure to secure public safety and/or male the bldg's structure and appurtenances conform to the provisions ofthe adminstrative code after unsafe report filed by qpsi. "cr-m0000126

    Mar 21, 2025

    Resolve
  • Class - 1

    28-323.8, rcny 103-13(5) failure to secure public safety and/or make the building's structure and appurtenances conform to the provisions ofthe admin code after unsafe notification filed by qpsi dated 10/25/202

    Nov 24, 2023 · Penalty $2,500

    Active
  • Class - 1

    28-323.1 failure to maintain parking structure in safe condition. note:-observed on an occupied parking structure from 1 st floor to 6th floor spalling on concrete and spalling from beam and slabs, deteriorati

    Nov 24, 2023 · Penalty $2,500

    Active
  • Class - 2

    Exit doors not self closing. noted: at garage,exit doors not self closing at 6 floor front & rear,5fl front,4fl front 2nd fl front & cellar front stairway missing fire proof self closing door. remedy: repair &

    Nov 22, 2013

    Resolve
  • Class - 2

    Work w/o permit. noted: installed 2 double face wall mounted business illuminated signs w/copy "rapid park" one w/flashing arrows. remedy: obtain permit.

    Nov 22, 2013 · Penalty $400

    Resolve
  • Class - 1

    Fail to provide unobstructed exit passageway. note @ 6th flr of above premises exit stair @ rear blocked by cars, 5th flr exit @ front & rear blocked by cars. 4th flr front exit stair partially blocked by car.

    Nov 18, 2011 · Penalty $1,200

    Resolve
  • Class - 1

    Fail to maintain bldg in code compliant manner note @ cellar level of above premises section of steel q decking is rusted, @ ceiling also section of concrete has fallen from ceiling joist. 1st flr cracks in con

    Nov 18, 2011 · Penalty $1,000

    Resolve
  • Class - 2

    Failure to maintain bldg in code complaint manner.noted:the concrete is spalling leaving the rebars exposed on the ceiling on floor 1,2,3 & 4th.remedy:repair and/or replace concrete.

    Oct 3, 2009 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to maintain bldg in code-compliant manner. defects noted: at 5th flr thru roof level staircase wall has vertical step cracks at exp #3 approx 1/2". remedy: repair and/or replace. provide engineering

    Apr 3, 2009 · Penalty $500

    Resolve
  • Hazardous

    Failure to post sign with occupant loads noted : failure to post certificate of occupancy. remedy : post certificate of occupancy

    Aug 29, 2006

    Resolve
Show 15 more ↓
  • Hazardous

    Failure to comply with the commissioners order to file a certificate of correction with the d.o.b. for vi. # 34497877y. noted : violation remains unremedied & no certificate of correction was filed. remedy: fil

    Aug 29, 2006

    Resolve
  • Hazardous

    Failure to post certificate of occupancy. remedy: post c. of o.

    Oct 21, 2005 · Penalty $250

    Resolve
  • Hazardous

    Exit passageway or corridor total obstruction. noted: second through sixth floor, front and rear exits are blocked. front exits by parked vehicles and rear exit second and third exits by parked vehicles. rear

    Oct 21, 2005 · Penalty $480

    Resolve
  • Hazardous

    Work without a permit. work noted: auto hydraulic lifts bolted to floor: sixth floor 6 lifts, fifth floor 7 lifts and fourth floor 7 lifts. remedy: obtain permit or restore to prior legal conditions.

    Oct 21, 2005 · Penalty $500

    Resolve
  • Hazardous

    Exit door total obstruction. noted: third and sixth floor rear secondary exit doors do not open. also noted: first floor front stairwell exit doors blocked by padlocked roll-down gate in closed position. during

    Oct 21, 2005 · Penalty $480

    Resolve
  • Hazardous

    Exit lighting defective/ fails to meet building code standards. noted:second and fourth floor rear exit light out (red bulbs). also noted: second and third floor stairwell lighting is not working. remedy:repair

    Oct 21, 2005 · Penalty $180

    Resolve
  • Hazardous

    Exit sign defective/ fails to meet building code standards. noted: cellar floor rear has no exit sign. cellar front sign is not working. remedy: repair/replace sign.

    Oct 21, 2005 · Penalty $130

    Resolve
  • Non-hazardous

    Failure to maintain building. defects noted: cellar concrete ceiling spalling with exposed rebar. throughout. bottom of structural steel beams missing fire proofing at several locations. at flange. also noted:

    Oct 21, 2005 · Penalty $350

    Resolve
  • Non-hazardous

    Failure to maintain exterior building wall. noted: front facade above sixth floor windows has two spalling limestone rectangular decorative inserts. remedy: maintain exterior building wall. make all necessary

    Oct 21, 2005 · Penalty $350

    Resolve
  • Hazardous

    Failure to maintain building concrete spalling on underside on first fl. concrete ceiling slab. re-bars have been exposed. in basement fire proofing has fallen off structural steel members. remedy: make area

    Jul 23, 2004 · Penalty $2,000

    Resolve
  • Hazardous

    Failure to maintain: note : (1) spalling loose concrete in danger of falling w/ exopsed steel i beams & exposed rebar at 1st fl & basement ceiling ( concrete slabs ) (2) at basement exposed wood floor joists w/

    Mar 2, 2004 · Penalty $800

    Resolve
  • Hazardous

    Required means of egress obstructed : note : (1) exit doors to rear fire escape do not open & are obstructed with hydraloic car jacks & locks on doors. all floors. (2) exit door to rear at first floor sealed ob

    Mar 2, 2004

    Resolve
  • Non-hazardous

    Failure to maintain noted in cellar broken and defective and has collapsed fire proof concrete around steel member exposing steel also steel columns exposed at front. remedy: make all repairs in a safe and law

    Oct 29, 2001 · Penalty $180

    Resolve
  • Non-hazardous

    18m7,37g12,54g7,75u5,57o2,40o2,36w7. 18-provide covers for hoistway interlocks. 37-provide proper fuses. 54-provide proper fuses. 75-perform 5yr full load safety test & file. 57-remove debris from pit

    Feb 26, 1999 · Penalty $180

    Resolve
  • Hazardous

    Defective & missing exit signs at front & rear exits, exit door at st level (front) obstructed by metal gates, roll-down shutters and padlocks, exit doors to rear fire escape obstructed by 2x4 lumber and plywoo

    May 22, 1990 · Penalty $1,150

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

DatePriceTypeUnits
Nov 25, 2025$2,750,000Commercial garages1

Building details

Building type
Garage / gas station (G1)
Year built
1911
Floors
6
Residential units
—
Building area
30,432 ft²
Lot area
5,325 ft²
Zoning
C6-2
Community board
104
Council district
6
Block / lot
1065 / 25
Assessed value
$3,544,650
Landmark / historic district
No

Questions about 411 West 55 Street

Who owns 411 West 55 Street?

The owner of record in NYC Department of City Planning PLUTO data is 411 West 55 LLC.

Does 411 West 55 Street have violations?

NYC HPD has no housing violations on record for this property.

Is 411 West 55 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 411 West 55 Street built?

City records list 1911 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.