roofy

440 West 41st Street

Manhattan, NY 10036BBL 1-01050-7501Map

Owner of record: 440 W 41 Owner LLC

440 West 41st Street is a condominium built in 1988 in Manhattan, 10036. It has 9 residential units across 14 floors. The owner of record is 440 W 41 Owner LLC. HPD has recorded 11 housing violations here, most recently on April 29, 2026. City tax records listed 9 rent-stabilized apartments here in 2024.

HPD violations
11
DOB violations
1
ECB violations
37
HPD complaints
34

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Apr 29, 2026

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

Rent-stabilized units in 2024
9
About 100% of the building's 9 apartments

Counts come from owners' rent-stabilization filings shown on NYC Department of Finance tax bills, as extracted by JustFix. They tell you a building has stabilized apartments, not which ones.

Stabilized units by tax-bill year

Think your apartment is stabilized? Request its rent history from HCR (free), then check your renewal with the renewal calculator.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 11

  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 29, 2026

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 17, 2025

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 15, 2023

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Mar 15, 2023

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Nov 3, 2022

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Feb 16, 2022

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Feb 16, 2022

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 1, 2021

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 2, 2015

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Feb 3, 2015

    Closed — Violation dismissed
Show 1 more ↓
  • B

    Provide an adequate supply of water for the wet sprinkler and/or standpipe system at sprinkler system all stories throughout at public hall

    Nov 21, 2013

    Closed — Violation closed

DOB building violations · 1

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 5, 2025

    Dob violation - dismissed

ECB violations · 37

  • Class - 1

    Failure to install grounding electrode conductor in accordance with section. observed in the main electrical room no installation of electrode ground rod present. this is second means of grounding must provide.

    Apr 7, 2026 · Penalty $4,800

    Active
  • Class - 1

    Unapproved/unsafe/unsuitable electrical equipment, apparatus, materials, devices, appliances or wiring in use. observed in the sub cellar in the janitors closet one electric hot water heater has no means of dis

    Apr 7, 2026 · Penalty $1,600

    Active
  • Class - 2

    At time of inspection, work completed under permit m08021119-i1-el expiring on 10/29/2025 however failure to submit certificate of correction for violation # 39131574m issued on 11/27/2024 for electrical work w

    Oct 14, 2025 · Penalty $6,250

    Active
  • Class - 1

    I observed in dob records the failure to submit an electrical permit for the work completed for ecbs # 39088336x,& 39088338j issued on 06/12/2023. all electrical work shall be permitted prior to beginning work.

    Nov 27, 2024 · Penalty $1,630

    Active
  • Class - 1

    Unlawful acts: failure to comply with commissioner's order as stated in ecb 39088338j issued on 06/12/2023 and submit a c of c., comply with commissioner's order; file a c of c for correction of violating condi

    Nov 27, 2024 · Penalty $6,250

    Resolve
  • Class - 1

    I observed in dob records the submission of c of c #0249597 on 08/03/2023 for ecb# 39088336x with no permit included. the commissioner's order state that all required permits shall be obtained., comply with com

    Nov 27, 2024 · Penalty $6,250

    Resolve
  • Class - 2

    I observed in the corridors at the stairway entrances the emergency lights installed under permit# m00915799 installed with canopy base missing and the junction box and wires exposed., perform proper installati

    Nov 27, 2024 · Penalty $280

    Active
  • Class - 2

    Observed on floors 2-7 sprinkler main not painted red. as per bc 3303.7.7.2 the sprinkler main is not in a state of readiness when it's not painted red., repair and/or replace

    Jun 12, 2023 · Penalty $1,562

    Resolve
  • Class - 2

    I observed in the elevator motor room the improper support of the emt conduits. electrical systems may support other electrical systems as long as the main system is properly supported the conduits can't suppor

    Jun 12, 2023

    Resolve
  • Class - 2

    I observed on floors 8 thru 13 the installation of emergency lights, bx cabling and lighting in the halls and compactor rooms. permits on file in dob records do not cover this scope of work, obtain permit; obta

    Jun 12, 2023

    Resolve
Show 27 more ↓
  • Class - 2

    I observed in the second floor laundry room the failure to install gfci receptacle outlets behind the washing machines which are within 6' (feet) of a sink. photos taken., install gfc1 protection; provide gfci

    Jun 12, 2023 · Penalty $5,000

    Resolve
  • Class - 1

    I observed on the 10 floor i n the meter room the installation of data wiring equipment as per the ec the electrical closet shall be dedicated to electrical distribution electrical equipment only. photos taken.

    Jun 12, 2023 · Penalty $3,000

    Resolve
  • Class - 1

    Failure to maintain building in code compliant manner. service elevator equipment as per bc3001.2 & 27-987. upon inspection, the device is found to be out of service, creating a hazardous condition per 1rcny 11

    Jun 12, 2023 · Penalty $3,125

    Resolve
  • Class - 2

    Observed in the sub-cellar jim caps installed on the cast iron fittings. as per 102.3 of the pc maintenance. installations, both existing and new, and parts thereof shall be maintained in proper operating condi

    Jun 12, 2023 · Penalty $1,562

    Resolve
  • Class - 2

    Emergency exit doors are not installed/hindged to allow occupants to escape roof properly, (emergency exit doors open into the stair corridor) located at roof level., provide legal hardware; repair and/or repla

    Jun 12, 2023 · Penalty $1,562

    Resolve
  • Class - 2

    -hole penetration are filled with unpermitted foam material located throughout all mechanical rooms located at sub-cellar level., provide/maintain fire stopping; repair and/or replace

    Jun 12, 2023 · Penalty $3,125

    Resolve
  • Class - 1

    I observed on all floors in the common hallways the convenience outlets not of the tamper resistant type nor made tamper resistant as required by ll 39. all receptacles accessible to children below the height o

    Jun 12, 2023 · Penalty $4,000

    Resolve
  • Class - 2

    I observed on floors 8 thru 13 the installation of emergency lights at least 6 inches below the opening of the stairway door. all electrical equipment shall be install to avoid physical damage. also noted no eq

    Jun 12, 2023 · Penalty $4,000

    Active
  • Class - 1

    Class1restore to service for proper inspection by d/o/b

    Feb 15, 2022 · Penalty $500

    Resolve
  • Class - 1

    Found elevator out of service. restore to service.

    Dec 10, 2021 · Penalty $500

    Resolve
  • Class - 2

    Failure to comply w/the comm's order contained in summons/vio#35508071m issued on 07/03/21 & to file a cert of correction pursuant to 28-201.1 & 1rcny 102-01. remedy: comply w/comm's order &/or file a cert of c

    Aug 3, 2021

    Resolve
  • Class - 1

    Failure to safeguard all persons and property affected by constructionoperations.at 1st floor site not properly sealed off from public causing accumulation of dust.also on floors 3 thru 12 accumulation of dust

    Jul 3, 2021

    Resolve
  • Class - 1

    No door lock monitoring installed in this controller as mandated by 3.10.12 of appendix k3 of the 2014 nycbc. this is a controller feature which ensures passenger safety. remedy : file application, install dlm

    Mar 8, 2021 · Penalty $1,250

    Resolve
  • Class - 1

    No door lock monitoring installed in controller as mandated in 3.10.12 of appendix k of 2014 building codes. remedy: install dlm, file and perform test with nyc dob

    Aug 21, 2020 · Penalty $1,250

    Resolve
  • Class - 1

    No door lock monitoring installed in controller as mandated in 3.10.12 of appendix k of 2014 building codes. remedy: install dlm, file and perform test with nyc dob

    Aug 21, 2020 · Penalty $1,250

    Resolve
  • Class - 1

    Permanent dwelling used/converted from other than permanentn residential purposes. co/o #113993 indicates building to be legally approved asa class "a" m.d. now apt #9r used/converted to transient use noted: ha

    May 30, 2019 · Penalty $3,125

    Resolve
  • Class - 1

    Bc907.2.8 failure to provide fire alarm system for transient use found in apt 9b. previous violation 55418040k. rmdy: discontinue illegal occupancy.

    May 30, 2019 · Penalty $3,125

    Resolve
  • Class - 1

    Failure to maintain building in code compliant manner. lack of a system of automatic sprinklers where required per bc 703.2 - 27954 for transient use found in apt 9b. previous violation 35418039n. rmdy:disconti

    May 30, 2019 · Penalty $781

    Resolve
  • Class - 1

    Permanent dwelling used/converted for othern than permanent residential purposeds. cofo #113993 indicates premises to be legally approved asa class "a" multiple dwelling. now apartments #10f and 12a have been

    May 24, 2019 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to maintain building in code compliant manner. lack of a system of automatic sprinkler where required as per bc 903.2 and 27-954 fortransient use of apt #10f and apt #12a. rmdy: discontinue illegal use.

    May 24, 2019 · Penalty $312

    Resolve
  • Class - 1

    Bc 907.2.8 failure to provide fire alarm system for transient use at apt 10e and 12a. rmdy: discontinue illegal use.

    May 24, 2019 · Penalty $2,500

    Resolve
  • Class - 2

    Temporary construction equipment on site expired permit.noted:at time of inspection there is a shed on exp#1 of the building under permit#140290833.permit expired on 12/15/15.remedy:renew permit

    Apr 6, 2016 · Penalty $4,000

    Resolve
  • Class - 1

    Filed a application form containing a material false statement. job #122000486 pw1 section 26 indicates a'no'for owners certification regarding occupied status(remain occupied)& also"no"regaeding rent control/

    Aug 6, 2015 · Penalty $24,000

    Resolve
  • Class - 2

    Failure to file an acceptable amended cycle 7 report to this department indicating correction of unsafe conditions described in initial local law fisp report.rem:file an amended report following remedial repair

    May 29, 2015 · Penalty $4,000

    Resolve
  • Class - 2

    19m07;97o02;100x10;10h10;98m15;42d06; (19-m-07)provide zone lock restrictor (97-o-02)clean entire device,machine,governor,top of car a pit.(100-x-10)repair lobby indicators. (10-h-10)car door gibs. (98-m-15) no

    May 14, 2015 · Penalty $2,500

    Resolve
  • Class - 1

    19m07;100x10;97o62;59o02;10h10;45o02;98m15;60b07;42d06; (19-m-07)zone lock restrictor missing/provide. (100-x-10)lobby indicates repair. (97-o-02)clean machine of metal chips & entire device clean. (59-o-02)

    May 14, 2015 · Penalty $5,000

    Resolve
  • Class - 1

    Permanent dwelling used/converted for other than permanent - residential purposes. noted: c/o & i-cards indicate 13 sty bldg to be legally approved as class 'a' apt bldg. apts on 9th flr #9h;9l;9a.now converted

    Sep 26, 2013 · Penalty $3,200

    Resolve

Complaints

  • Water leak

    Heavy flow

    May 21, 2026 · Apt 5KAPTI

    Close
  • Plumbing

    Bathtub/shower

    Nov 21, 2024 · Apt 5K

    Close
  • Heat/hot water

    Entire building

    Feb 20, 2023 · Apt 5E

    Close
  • Unsanitary condition

    Garbage/recycling storage

    Jul 8, 2022 · Apt 6K

    Close
  • Unsanitary condition

    Mold

    Jul 8, 2022 · Apt 6K

    Close
  • Unsanitary condition

    Pests

    Jul 8, 2022 · Apt 6K

    Close
  • Elevator

    Maintenance

    Jul 8, 2022 · Apt 6K

    Close
  • Unsanitary condition

    Garbage/recycling storage

    Mar 4, 2022 · Apt BLDG

    Close
  • Heat/hot water

    Apartment only

    Jan 6, 2022 · Apt 10B

    Close
  • Electric

    Power outage

    Jan 6, 2022 · Apt 10B

    Close
Show 24 more ↓
  • Electric

    No lighting

    Dec 16, 2021 · Apt BLDG

    Close
  • Unsanitary condition

    Pests

    Apr 14, 2021 · Apt 4G

    Close
  • Door/window

    Door

    May 21, 2019 · Apt 6K

    Close
  • Unsanitary condition

    Garbage/recycling storage

    Aug 7, 2014 · Apt BLDG

    Close
  • Plumbing

    Sprinkler

    Nov 19, 2013 · Apt BLDG

    Close
  • General

    Mailbox

    Apr 16, 2011 · Apt BLDG

    Close
  • General

    Mailbox

    Mar 29, 2011 · Apt 4B

    Close
  • General

    Windows

    Feb 19, 2009 · Apt 9K

    Close
  • General

    Windows

    Feb 12, 2009 · Apt 9K

    Close
  • Nonconst

    Rubbish

    Dec 16, 2008 · Apt ALL

    Close
  • Appliance

    Refrigerator

    Dec 16, 2008 · Apt ALL

    Close
  • General

    Windows

    Dec 9, 2008 · Apt 9K

    Close
  • General

    Windows

    Dec 9, 2008 · Apt 9K

    Close
  • Heating

    Heat related

    Dec 9, 2008 · Apt 9K

    Close
  • General

    Windows

    Nov 20, 2008 · Apt 5J

    Close
  • Nonconst

    Vermin

    Jul 31, 2008 · Apt 5D

    Close
  • Heating

    Heat related

    Feb 29, 2008 · Apt 13

    Close
  • Heating

    Heat related

    Feb 11, 2008 · Apt 13

    Close
  • General

    Stairs

    Jan 7, 2008 · Apt BLDG

    Close
  • General

    Ceramic-tile

    Jul 6, 2007 · Apt BLDG

    Close
  • General

    Ceramic-tile

    Jul 6, 2007 · Apt BLDG

    Close
  • Plumbing

    Water-leaks

    Sep 30, 2004 · Apt 9H

    Close
  • Plumbing

    Water-leaks

    Sep 30, 2004 · Apt 9H

    Close
  • Appliance

    Sprinker cert

    Jul 26, 2004

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Condominium (RM)
Year built
1988
Floors
14
Residential units
9
Building area
53,177 ft²
Lot area
9,875 ft²
Zoning
C6-3
Community board
104
Council district
3
Block / lot
1050 / 7501
Assessed value
$8,261,551
Landmark / historic district
No

HPD registration #141446, last renewed Nov 17, 2025.

Questions about 440 West 41st Street

Who owns 440 West 41st Street?

The owner of record in NYC Department of City Planning PLUTO data is 440 W 41 Owner LLC.

Does 440 West 41st Street have violations?

Yes. NYC HPD has recorded 11 housing violations at this property.

Is 440 West 41st Street rent stabilized?

NYC Department of Finance tax bills listed 9 rent-stabilized units here in 2024 (about 100% of its 9 apartments). To confirm a specific apartment, request its rent history from NYS Homes and Community Renewal.

When was 440 West 41st Street built?

City records list 1988 as the year it was built.

How many apartments are in 440 West 41st Street?

It has 9 residential units and 11 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.